Diagnostic Technics, NeurologicalNCT04608292
Measuring Fluid Flow in the Brain Using Alcohol and MRI in Healthy Participants
A study testing Single-voxel MRS, Multi-voxel MRSI and Magnetization Transfer Imaging in people with Diagnostic Technics, Neurological, run by Sunnybrook Health Sciences Centre at 1 site in Canada.
Trial summary
Intracranial interstitial fluid (ISF) flow is crucial for adequate clearance of extracellular waste products from the brain parenchyma. Recent demonstrations have shown that a deficiency in flow leads to the accumulation of such waste products in neurodegenerative disorders. Read more about this study
- Who is it for?
- Ages 20 to 75 years, men onlyHealthy volunteers can take part
- Conditions the study is for
- Diagnostic Technics, Neurological
- What is being tested?
- Single-voxel MRS, Multi-voxel MRSI and Magnetization Transfer Imaging
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 10 participants
- Where
- 1 siteCanada
- Study dates
- Jan 2026to Jan 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 20 to 75 years
- Men only
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Ability to consent, effectively communicate with the investigator, and comply with study protocols
- Low consumer of ethanol (less than 6 drinks per week where a drink is 1 oz of distilled spirits, 6 oz wine, 12 oz beer)
Who cannot join
- Contraindications to MRI
- History of alcohol or substance abuse
- History of liver pathology
- Currently taking medication such as metronidazole which could induce a disulfiram reaction with ethanol
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Canada1 site
Sunnybrook Research Institute
Toronto, Ontario, M4N 3M5
Wilfred W Lam, DPhil, 416-480-6100 ext. 63390, lamw@sri.utoronto.ca
Jesse M Klostranec, MD
About this study
Official title: Quantitative Measurement of Intracranial Interstitial Fluid Flow Using Magnetic Resonance Spectroscopy
Intracranial interstitial fluid (ISF) flow is crucial for adequate clearance of extracellular waste products from the brain parenchyma. Recent demonstrations have shown that a deficiency in flow leads to the accumulation of such waste products in neurodegenerative disorders. Unfortunately, no clinical investigation that gives a quantitative measure of ISF flow exists. Such a test could prove very useful in the clinical setting for multiple neurologic disorders by providing a measure of potential diagnostic importance, as well as yielding a means to monitor response to treatment.
The investigators hypothesize that such an investigation can be developed using magnetic resonance spectroscopy to give a quantitative measure of ISF flow, using spectroscopy of ethanol as a dynamic marker of interstitial fluid. Beneficially, the approach is non-invasive. This pilot project aims to develop this technique with proof of concept in healthy volunteers (males in the age range of 20-75).
This pilot project aims to develop the technique, demonstrating its ability to detect ISF flow and potential differences in rates among healthy volunteers. Success at this stage will give rise to this technique being extended to studies involving individuals with various forms of intracranial pathology for comparison with values seen in healthy individuals, with the ultimate goal of it providing a measure of diagnostic significance in multiple clinical scenarios.
Read the detailed description
Study hypothesis:
Intracranial interstitial fluid (ISF) flow is crucial for adequate clearance of extracellular waste products from the brain parenchyma. Recent demonstrations have shown that its deficiency leads to their accumulation in neurodegenerative disorders. The hypothesis of this project is MRS and/or MTI can be used to give a quantitative measure of intracranial interstitial fluid flow.
Goals:
The primary goal is to provide a quantitative measure of ISF flow rate through the brain parenchyma. This will be performed by making multiple measurements of the characteristic ethanol peak at different time points with MRS or ethanol-related decreases in water saturation signal in MTI, following its ingestion. This will allow the transit of ethanol, which is equal to the transit of ISF, to be obtained and reported using common transport parameters such as time-to-peak (TTP) and mean transit time (MTT).
Secondary objectives include determining a range of values that may be considered normal ranges for ISF flow rates in healthy individuals. This will be helpful in future experiments when such values will be compared with rates measuring for individuals with various different types of intracranial pathology.
INVESTIGATION STUDY DESIGN:
This pilot project will be experimental with the aim of determining the best quantitative criteria from ethanol MRS or MTI labeling of intracranial ISF flow data to give a reliable clearance metric. To achieve this, the initial proof of concept study will involve 10 healthy male volunteers between the ages of 20-75 undergoing the ethanol-MRS or MTI protocol. This work will be quantitative in nature, since discrete MR signals will be measured and analyzed.
Data Collection Study participants will be required to have fasted a minimum of 6 hours prior to initiating the experiment and refrained from alcohol ingestion for 12 hours. A quick screen will be performed by a research team member of the participant's medications, alcohol consumption, and any neurological conditions prior to moving forward with the examination to verify all volunteers meet all inclusion criteria for the study.
Data will be acquired using either magnetic resonance spectroscopy (MRS), magnetic resonance spectroscopic imaging (MRSI), or magnetization transfer imaging (MTI). A relatively short acquisition (5-7 minutes) will be repeated to acquire a time course for ethanol transit through the brain.
Each study participant will undergo pre-ethanol ingestion MR acquisition. The volunteer will then be given an ethanol-containing beverage. The ethanol content will be approximately 0.5 g/kg, mixed in 355 mL of a non-caffeinated, sugar-free carbonated drink as done previously in other human ethanol MRS experiments (7). The drink must be consumed within 5 minutes and may be provided through clear plastic tubing so the subject does not have to be removed from the scanner. Blood alcohol concentration (BAC) levels for this work are not expected to exceed 0.05%, considered a low level, at the end of the experiment.
After consuming the ethanol-containing beverage, scout images will be acquired again to re-localize the voxels for each subsequent spectral image if study participants need to be placed back in the MR scanner (i.e., did not ingest ethanol through tubing). MRS, MRSI, or MTI will be performed at ~5-7 minutes/spectrum or image, repeating the process continuously for 60-90 minutes. During the scanning, the patient may be asked to breathe through the ClearMate (CM), a specially designed, MR-compatible non-rebreathing circuit that provides oxygen and carbon dioxide that quickly decreases a person's blood alcohol level.
After the final acquisition, the patient will be taken to a supervised area where he/she will remain until blood ethanol levels are registered below 0.05% via a standard breathalyzer test. Once the participant has met this requirement and state that they feel safe to leave the premises, they will be free to go within the recommendations of the study and their participation considered to be complete. Breath sampling will be performed at 30-minute intervals if it is still high.
Finally, since the most accurate way to assess the blood alcohol kinetics is by making comparisons of arterial and venous blood levels, peripheral arterial lines will be inserted (by a Sunnybrook staff anesthesiologist) in a few select study participants. Periodic arterial blood samples from these individuals will be measured for the blood alcohol content and compared with the values for blood samples drawn concurrently from the peripheral intravenous line.
- Conditions
- Diagnostic Technics, Neurological
- Being tested
- Single-voxel MRS, Multi-voxel MRSI, Magnetization Transfer Imaging, Alcohol ingestion, ClearMate
- Medical subject headings
- Neurologic Manifestations
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Single-voxel MRSDiagnostic test
Diagnostic test is a single voxel MRS scan
Multi-voxel MRSIDiagnostic test
Diagnostic test is a multi-voxel MRS imaging scan
Magnetization Transfer ImagingDiagnostic test
Diagnostic test is a set of magnetic transfer weighted images
Alcohol ingestionOther
Participants will ingest an ethanol-containing beverage of approximately 0.5g/kg of ethanol mixed in 355 mL of a non-caffeinated, sugar-free carbonated drink which must be consumed in 5 minutes
ClearMateDevice
Participants will breathe through the ClearMate, an MR-compatible non-rebreathing circuit which provides oxygen and carbon dioxide that quickly decreases a person's blood alcohol level.
Blood samplingDiagnostic test
Participants will have a peripheral arterial and peripheral venous line inserted and periodic arterial and venous blood samples will be measured for blood alcohol content.
| Study group | Role | What they receive |
|---|---|---|
| Single-voxel MRS | Active comparator | MRS Receives: Diagnostic Test: Single-voxel MRS; Other: Alcohol ingestion |
| Multi-voxel MRSI | Active comparator | MRSI Receives: Diagnostic Test: Multi-voxel MRSI; Other: Alcohol ingestion |
| Magnetization Transfer Imaging | Active comparator | MTI Receives: Diagnostic Test: Magnetization Transfer Imaging; Other: Alcohol ingestion |
| Single-voxel MRS + ClearMate | Active comparator | MRS+CM Receives: Diagnostic Test: Single-voxel MRS; Other: Alcohol ingestion; Device: ClearMate |
| Multi-voxel MRSI + ClearMate | Active comparator | MRSI+CM Receives: Diagnostic Test: Multi-voxel MRSI; Other: Alcohol ingestion; Device: ClearMate |
| Magnetization Transfer Imaging + ClearMate | Active comparator | MTI+CM Receives: Diagnostic Test: Magnetization Transfer Imaging; Other: Alcohol ingestion; Device: ClearMate |
| Single-voxel MRS + ClearMate + Blood Sampling | Active comparator | MRS+CM+B Receives: Diagnostic Test: Single-voxel MRS; Other: Alcohol ingestion; Device: ClearMate; Diagnostic Test: Blood sampling |
| Multi-voxel MRSI + ClearMate + Blood Sampling | Active comparator | MRSI+CM+B Receives: Diagnostic Test: Multi-voxel MRSI; Other: Alcohol ingestion; Device: ClearMate; Diagnostic Test: Blood sampling |
| Magnetization Transfer Imaging + ClearMate + Blood Sampling | Active comparator | MTI+CM+B Receives: Diagnostic Test: Magnetization Transfer Imaging; Other: Alcohol ingestion; Device: ClearMate; Diagnostic Test: Blood sampling |
What is being measured
The primary outcome is the main question the study is designed to answer.
Intracranial Interstitial Fluid Flow Rate
The calculated flow rate of intracranial interstitial fluid and its standard deviation
Measured: Within 1 week of actual measurement
Secondary outcomes (1)
Blood alcohol levels
Level of alcohol in venous and arterial blood during the examination
Measured: Within 1 week of blood samples
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted29 Oct 2020
- Study startJan 2026 (estimated)
- Primary completionJan 2027 (estimated)
- Study completionJan 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Diagnostic Technics, NeurologicalStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Non-randomised
- Intervention model
- Sequential
- Model description
- The study will begin with the simplest imaging measurements, and only proceed to longer or more complicated measurements if necessary. Re-breathing apparatus will be used only once the imaging measurement has been decided upon, and blood sampling will be used only on a few subjects to confirm the results. Thus, while there are 9 arms to this trial, it is possible that as few as 3 arms will actually be used.
- Masking
- None (open label)
- Enrolment
- 10 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Sunnybrook Health Sciences Centre
- Sponsor type
- University, hospital or other
- Collaborators
- University Health Network, Toronto
- Responsible party
- Sponsor
- Investigators
- Greg J Stanisz, PhD, Principal investigator, Sunnybrook Research InstituteDavid Mikulis, MD, Principal investigator, Krembil Research Institute
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04608292
- Sponsor's protocol ID
- 023-2020
- Status last verified
- May 2024
- First submitted
- 23 Oct 2020
- Last updated
- 17 May 2024
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 17 May 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Quantitative Measurement of Intracranial Interstitial Fluid Flow Using Magnetic Resonance Spectroscopy
- ClinicalTrials.gov ID
- NCT04608292
- Acronym / sponsor ID
- 023-2020
- Conditions
- Diagnostic Technics, Neurological
- Study type
- Interventional
- Recruitment status
- Not yet recruiting
- Enrolment
- 10 participants (estimated)
- Lead sponsor
- Sunnybrook Health Sciences CentreUniversity, hospital or other
- Collaborators
- University Health Network, Toronto
- Study start
- Jan 2026 (estimated)
- Primary completion
- Jan 2027 (estimated)
- Study completion
- Jan 2028 (estimated)
- First posted
- 29 Oct 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Intracranial interstitial fluid (ISF) flow is crucial for adequate clearance of extracellular waste products from the brain parenchyma. Recent demonstrations have shown that a deficiency in flow leads to the accumulation of such waste products in neurodegenerative disorders. Unfortunately, no clinical investigation that gives a quantitative measure of ISF flow exists. Such a test could prove very useful in the clinical setting for multiple neurologic disorders by providing a measure of potential diagnostic importance, as well as yielding a means to monitor response to treatment.
The investigators hypothesize that such an investigation can be developed using magnetic resonance spectroscopy to give a quantitative measure of ISF flow, using spectroscopy of ethanol as a dynamic marker of interstitial fluid. Beneficially, the approach is non-invasive. This pilot project aims to develop this technique with proof of concept in healthy volunteers (males in the age range of 20-75).
This pilot project aims to develop the technique, demonstrating its ability to detect ISF flow and potential differences in rates among healthy volunteers. Success at this stage will give rise to this technique being extended to studies involving individuals with various forms of intracranial pathology for comparison with values seen in healthy individuals, with the ultimate goal of it providing a measure of diagnostic significance in multiple clinical scenarios.
Detailed description
Study hypothesis:
Intracranial interstitial fluid (ISF) flow is crucial for adequate clearance of extracellular waste products from the brain parenchyma. Recent demonstrations have shown that its deficiency leads to their accumulation in neurodegenerative disorders. The hypothesis of this project is MRS and/or MTI can be used to give a quantitative measure of intracranial interstitial fluid flow.
Goals:
The primary goal is to provide a quantitative measure of ISF flow rate through the brain parenchyma. This will be performed by making multiple measurements of the characteristic ethanol peak at different time points with MRS or ethanol-related decreases in water saturation signal in MTI, following its ingestion. This will allow the transit of ethanol, which is equal to the transit of ISF, to be obtained and reported using common transport parameters such as time-to-peak (TTP) and mean transit time (MTT).
Secondary objectives include determining a range of values that may be considered normal ranges for ISF flow rates in healthy individuals. This will be helpful in future experiments when such values will be compared with rates measuring for individuals with various different types of intracranial pathology.
INVESTIGATION STUDY DESIGN:
This pilot project will be experimental with the aim of determining the best quantitative criteria from ethanol MRS or MTI labeling of intracranial ISF flow data to give a reliable clearance metric. To achieve this, the initial proof of concept study will involve 10 healthy male volunteers between the ages of 20-75 undergoing the ethanol-MRS or MTI protocol. This work will be quantitative in nature, since discrete MR signals will be measured and analyzed.
Data Collection Study participants will be required to have fasted a minimum of 6 hours prior to initiating the experiment and refrained from alcohol ingestion for 12 hours. A quick screen will be performed by a research team member of the participant's medications, alcohol consumption, and any neurological conditions prior to moving forward with the examination to verify all volunteers meet all inclusion criteria for the study.
Data will be acquired using either magnetic resonance spectroscopy (MRS), magnetic resonance spectroscopic imaging (MRSI), or magnetization transfer imaging (MTI). A relatively short acquisition (5-7 minutes) will be repeated to acquire a time course for ethanol transit through the brain.
Each study participant will undergo pre-ethanol ingestion MR acquisition. The volunteer will then be given an ethanol-containing beverage. The ethanol content will be approximately 0.5 g/kg, mixed in 355 mL of a non-caffeinated, sugar-free carbonated drink as done previously in other human ethanol MRS experiments (7). The drink must be consumed within 5 minutes and may be provided through clear plastic tubing so the subject does not have to be removed from the scanner. Blood alcohol concentration (BAC) levels for this work are not expected to exceed 0.05%, considered a low level, at the end of the experiment.
After consuming the ethanol-containing beverage, scout images will be acquired again to re-localize the voxels for each subsequent spectral image if study participants need to be placed back in the MR scanner (i.e., did not ingest ethanol through tubing). MRS, MRSI, or MTI will be performed at ~5-7 minutes/spectrum or image, repeating the process continuously for 60-90 minutes. During the scanning, the patient may be asked to breathe through the ClearMate (CM), a specially designed, MR-compatible non-rebreathing circuit that provides oxygen and carbon dioxide that quickly decreases a person's blood alcohol level.
After the final acquisition, the patient will be taken to a supervised area where he/she will remain until blood ethanol levels are registered below 0.05% via a standard breathalyzer test. Once the participant has met this requirement and state that they feel safe to leave the premises, they will be free to go within the recommendations of the study and their participation considered to be complete. Breath sampling will be performed at 30-minute intervals if it is still high.
Finally, since the most accurate way to assess the blood alcohol kinetics is by making comparisons of arterial and venous blood levels, peripheral arterial lines will be inserted (by a Sunnybrook staff anesthesiologist) in a few select study participants. Periodic arterial blood samples from these individuals will be measured for the blood alcohol content and compared with the values for blood samples drawn concurrently from the peripheral intravenous line.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Non-randomised
- Intervention model
- Sequential
- Masking
- None (open label)
- Number of arms
- 9
- Model description
- The study will begin with the simplest imaging measurements, and only proceed to longer or more complicated measurements if necessary. Re-breathing apparatus will be used only once the imaging measurement has been decided upon, and blood sampling will be used only on a few subjects to confirm the results. Thus, while there are 9 arms to this trial, it is possible that as few as 3 arms will actually be used.
| Arm | Type | Receives |
|---|---|---|
| Single-voxel MRS | Active comparator | Diagnostic Test: Single-voxel MRS, Other: Alcohol ingestionMRS |
| Multi-voxel MRSI | Active comparator | Diagnostic Test: Multi-voxel MRSI, Other: Alcohol ingestionMRSI |
| Magnetization Transfer Imaging | Active comparator | Diagnostic Test: Magnetization Transfer Imaging, Other: Alcohol ingestionMTI |
| Single-voxel MRS + ClearMate | Active comparator | Diagnostic Test: Single-voxel MRS, Other: Alcohol ingestion, Device: ClearMateMRS+CM |
| Multi-voxel MRSI + ClearMate | Active comparator | Diagnostic Test: Multi-voxel MRSI, Other: Alcohol ingestion, Device: ClearMateMRSI+CM |
| Magnetization Transfer Imaging + ClearMate | Active comparator | Diagnostic Test: Magnetization Transfer Imaging, Other: Alcohol ingestion, Device: ClearMateMTI+CM |
| Single-voxel MRS + ClearMate + Blood Sampling | Active comparator | Diagnostic Test: Single-voxel MRS, Other: Alcohol ingestion, Device: ClearMate, Diagnostic Test: Blood samplingMRS+CM+B |
| Multi-voxel MRSI + ClearMate + Blood Sampling | Active comparator | Diagnostic Test: Multi-voxel MRSI, Other: Alcohol ingestion, Device: ClearMate, Diagnostic Test: Blood samplingMRSI+CM+B |
| Magnetization Transfer Imaging + ClearMate + Blood Sampling | Active comparator | Diagnostic Test: Magnetization Transfer Imaging, Other: Alcohol ingestion, Device: ClearMate, Diagnostic Test: Blood samplingMTI+CM+B |
Who may qualify
- Ages
- 20 to 75 years
- Sex
- Male only
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- Ability to consent, effectively communicate with the investigator, and comply with study protocols
- Low consumer of ethanol (less than 6 drinks per week where a drink is 1 oz of distilled spirits, 6 oz wine, 12 oz beer)
Key exclusion criteria (4 listed)
- Contraindications to MRI
- History of alcohol or substance abuse
- History of liver pathology
- Currently taking medication such as metronidazole which could induce a disulfiram reaction with ethanol
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Single-voxel MRSDiagnostic test is a single voxel MRS scan | Diagnostic test | Single-voxel MRS, Single-voxel MRS + ClearMate, Single-voxel MRS + ClearMate + Blood Sampling |
| Multi-voxel MRSIDiagnostic test is a multi-voxel MRS imaging scan | Diagnostic test | Multi-voxel MRSI, Multi-voxel MRSI + ClearMate, Multi-voxel MRSI + ClearMate + Blood Sampling |
| Magnetization Transfer ImagingDiagnostic test is a set of magnetic transfer weighted images | Diagnostic test | Magnetization Transfer Imaging, Magnetization Transfer Imaging + ClearMate, Magnetization Transfer Imaging + ClearMate + Blood Sampling |
| Alcohol ingestionParticipants will ingest an ethanol-containing beverage of approximately 0.5g/kg of ethanol mixed in 355 mL of a non-caffeinated, sugar-free carbonated drink which must be consumed in 5 minutes | Other | Magnetization Transfer Imaging, Magnetization Transfer Imaging + ClearMate, Magnetization Transfer Imaging + ClearMate + Blood Sampling, Multi-voxel MRSI, Multi-voxel MRSI + ClearMate, Multi-voxel MRSI + ClearMate + Blood Sampling, Single-voxel MRS, Single-voxel MRS + ClearMate, Single-voxel MRS + ClearMate + Blood Sampling |
| ClearMateParticipants will breathe through the ClearMate, an MR-compatible non-rebreathing circuit which provides oxygen and carbon dioxide that quickly decreases a person's blood alcohol level. | Device | Magnetization Transfer Imaging + ClearMate, Magnetization Transfer Imaging + ClearMate + Blood Sampling, Multi-voxel MRSI + ClearMate, Multi-voxel MRSI + ClearMate + Blood Sampling, Single-voxel MRS + ClearMate, Single-voxel MRS + ClearMate + Blood Sampling |
| Blood samplingParticipants will have a peripheral arterial and peripheral venous line inserted and periodic arterial and venous blood samples will be measured for blood alcohol content. | Diagnostic test | Magnetization Transfer Imaging + ClearMate + Blood Sampling, Multi-voxel MRSI + ClearMate + Blood Sampling, Single-voxel MRS + ClearMate + Blood Sampling |
Primary outcome
Intracranial Interstitial Fluid Flow Rate
Time frame: Within 1 week of actual measurement
The calculated flow rate of intracranial interstitial fluid and its standard deviation
1 secondary outcome
Blood alcohol levels
Time frame: Within 1 week of blood samples
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 May 2024.
- Individual participant dataSharing planned: No
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Greg J Stanisz, PhD principal investigator
Sunnybrook Research Institute
David Mikulis, MD principal investigator
Krembil Research Institute
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Single-voxel MRS, Multi-voxel MRSI and Magnetization Transfer Imaging in people with Diagnostic Technics, Neurological, run by Sunnybrook Health Sciences Centre at 1 site in Canada.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 17 May 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Each site lists its own contact: choose the nearest one under Trial locations. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Intracranial Interstitial Fluid Flow Rate (time frame: Within 1 week of actual measurement). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 May 2024.