MyopiaNCT04426175
Z8 OCT-controlled 2D vs 3D LASIK
A study testing 2D and 3D cutting method using a low energy Femtosecond laser LDV Z8 for LASIK flap cutting in people with Myopia and Astigmatism, run by Zentrumsehstarke Hamburg at 1 site in Germany.
Trial summary
The aim of this study was to test the hypothesis that OCT-guided 110 µm targeted flaps will result in accurate, predictable, and precise thickness flaps, with low complication rates when performed and compared using both 2D and 3D flap geometry applications and how it correlated to visual experience and quality of… Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Myopia, Astigmatism
- What is being tested?
- 2D and 3D cutting method using a low energy Femtosecond laser LDV Z8 for LASIK flap cutting
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 13 participants
- Where
- 1 siteGermany
- Study dates
- 5 Dec 2019to 23 Apr 2020
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Key inclusion criteria as described by the German Commission for Refractive Surgery (KRC) are:
- The recommended range of application for the correction of myopia is up to -8.00 D and for the correction of astigmatism up to 5.00 D.
- The limited for LASIK correction of myopia is up to -10.00 D and correction of astigmatism up to 6.00 D. If myopic astigmatism is to be corrected, the values for myopia and astigmatism must be added together.
- The recommended range for correction of hyperopia is up to 3.00 D. Up to 4.00 D is the range of limited application for hyperopia.
- Age ≥18 years with stable eyesight for over 12 months.
Who cannot join
- Key exclusion criteria as described by the German Commission for Refractive Surgery (KRC):
- preoperative corneal thickness less than 480 μm
- predicted stromal thickness under the flap after ablation of less than 250 μm
- chronic progressive corneal disease and forme fruste keratoconus
- surgery before the age of 18 years
- symptomatic cataract
Show all 11Show fewer
- Glaucoma with a marked loss of visual field
- Exudative macular degeneration.
- Concurrent participation in another ophthalmological clinical study
- Undergone former eye surgery
- Contact lens wear within the two weeks prior to commencement of preoperative measurements
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Precision of 2D vs 3D Low Energy Femto-LASIK: Intraoperative and Postoperative OCT-based Study
The aim of this study was to test the hypothesis that OCT-guided 110 µm targeted flaps will result in accurate, predictable, and precise thickness flaps, with low complication rates when performed and compared using both 2D and 3D flap geometry applications and how it correlated to visual experience and quality of life responses during the early postoperative period.
Read the detailed description
It has been postulated that it is possible with the Ziemer Femtosecond LDV laser system to create reproducible flaps in terms of thickness and predictability. The aim of this study was to test the hypothesis that OCT-guided 110 µm targeted flaps will result in accurate, predictable, and precise thickness flaps, with low complication rates when performed and compared using both 2D and 3D flap geometry applications. Patient-reported outcomes are increasingly incorporated into clinical trials as they provide access to valuable information on the physical experience of the patient during and after the treatment. A questionnaire will therefore also be introduced in this study to evaluate how well self-reported pain, visual experience, and quality of life responses are correlated with flap geometries in both groups during the early postoperative period. The study holds direct medical benefit to the patient in this that they received an immediate improvement in his/her unaided vision. Moreover, the patient's participation contributes to the medical knowledge about the use of femtosecond lasers for refractive surgery, in particular in view of the use of intraoperative OCT visualization tools. The patients will gain access to the newest technology available for refractive surgery namely a low pulse energy high-frequency femtosecond laser.
- Conditions
- Myopia, Astigmatism
- Being tested
- 2D and 3D cutting method using a low energy Femtosecond laser LDV Z8 for LASIK flap cutting
- Keywords
- Femtosecond Laser Assisted Laser in Situ Keratomileusis, LASIK, FEMTO LDV Z8
- Medical subject headings
- Myopia, Astigmatism
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
2D and 3D cutting method using a low energy Femtosecond laser LDV Z8 for LASIK flap cuttingDevice
2D and 3D cutting methods were randomly used in same subjects
| Study group | Role | What they receive |
|---|---|---|
| 2D LASIK | Experimental | With the 2D method, the flap resection is created in a planar mode (xy-plane), without vertical cut, at the requested depth. Receives: Device: 2D and 3D cutting method using a low energy Femtosecond laser LDV Z8 for LASIK flap cutting |
| 3D LASIK | Experimental | With the 3D method, the flap resection is done in a three-dimensional mode, at the requested depth, with the requested diameter and the desired border (side cut) angle Receives: Device: 2D and 3D cutting method using a low energy Femtosecond laser LDV Z8 for LASIK flap cutting |
What is being measured
The primary outcome is the main question the study is designed to answer.
Predictability of central flap thickness in OCT-controlled 110 µm LASIK
Analyze central flap thickness in OCT-controlled 110 µm LASIK and to report on intended versus achieved flap thickness of one group with a 2D flap geometry in one eye and another group with a 3D flap geometry in the contralateral eye. All OCT measurements will be done in micron metres (µm).
Measured: 1 month postoperatively
Secondary outcomes (7)
Comparison of intraoperative flap thickness with pre- and postoperative results
Measurement of corneal thickness pre flap creation (Corneal Pachymetry measurements expressed in µm indicate the thickness of the cornea before flap was created. This measurement will serve as the baseline measurement. Pachymetry measured again after the flap was created and lifted by means of optical and ultrasonic pachymetry(µm) for both groups and to be compare with postoperative AS-OCT measurements also measured in µm.This will indicate how accurate the intraoperative flap thickness compare to the 1 week and 1 month thickness measurements as swelling and inflammatory processes could influence postoperative measurements.
Measured: 1 week, 1 month
Postoperative planarity
Assessment of several measurements taken along the corneal cut on superior, nasal, inferior and temporal points in order to compare the uniformity of the cut between 2D vs 3D geometries. Measurments will be done by means of AS-OCT,measured in µm units.Measurements at two different follow up periods will be analyzed and compared in order to rule out the role that inflammation could possibly play.
Measured: 1 week, 1 month
Intraoperative flap morphology
Observations that are defined by different scales in order to report on important features pertaining to 2D and 3D intraoperative flap geometries eg. the presence and extent of opaque bubble layer (OBL), ease of flap lifting and stromal bed quality in both groups . Intraoperative flap morphology assessment to be done as soon as the flap was created in terms of presence of an opaque bubble layer (no OBL, 30-40% of flap surface, >40% of flap surface). Once the flap was lifted to report on ease of flap lifting (easy/sticky/can not lift) and to describe the stromal bed quality (smooth,tissue bridges, rastered, lines).
Measured: During surgery
Postoperative flap properties
Evaluate flap properties by means of slit lamp biomicroscopy examination. The flap's visual appearance seen with the slit lamp to be described and documented as per the suggested scales during 2 specified follow up visits in terms of edge quality and visibility ('yes/no' If yes= extreme fine line, distinct line or irregular edge), border shape (round, irregular) and interface quality (smooth, lines, cobblestones, grids, microstriae) and be compared between flap geometries (2D and 3D flaps).
Measured: 1 week, 1 month
Visual outcomes
Compare pre- and postoperative visual acuity (UDVA, CDVA) measurements by means of a Snellen Visual Acuity chart and be expressed in decimal that will be converted to logMar units for the purpose of statistical analysis.
Measured: 1 day, 1 week, 1 month
Patient reported Outcomes: early recovery period
Conduct a non validated Patient Reported Outcome (PRO) questionnaire adopted and based on the 'Brief Pain Inventory' questionnaire [Porela-Tiihonen] to assess patient's early visual perceptions and pain experience related to their own functional status and wellbeing and to compare between the two eyes since each undergone different cutting geometry (2D vs 3D) methods.
Measured: 1 day, 2Day, 1 week follow up
Complications
Report and document any intra- and postoperative complications that may occur during the time of the procedure or at the 1 month follow up visit.
Measured: Intra- and postoperatively up to 1 month follow up
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted11 Jun 2020
- Study start5 Dec 2019
- Primary completion23 Apr 2020
- Study completion23 Apr 2020
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (7)Papers the sponsor has linked to this study.
- Other trials for MyopiaStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 13 participants (actual)
Sponsor and investigators
- Lead sponsor
- Zentrumsehstarke Hamburg
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Stephan Linke, MD, Principal investigator, Zentrumsehstarke Hamburg
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04426175
- Sponsor's protocol ID
- CPFEM-0007-DE
- Status last verified
- Jun 2020
- First submitted
- 3 Jun 2020
- Last updated
- 11 Jun 2020
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: It is not clear yet to what extend IPD will be implemented. Patient privacy and confidentiality are the most important factors to consider. We consider sharing limited information upon request.
Publications
Huhtala A, Pietila J, Makinen P, Uusitalo H. Femtosecond lasers for laser in situ keratomileusis: a systematic review and meta-analysis. Clin Ophthalmol. 2016 Mar 7;10:393-404. doi: 10.2147/OPTH.S99394. eCollection 2016.
PubMed 27022236Eldaly ZH, Abdelsalam MA, Hussein MS, Nassr MA. Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study. Korean J Ophthalmol. 2019 Apr;33(2):113-121. doi: 10.3341/kjo.2018.0035.
PubMed 30977320Pajic B, Vastardis I, Pajic-Eggspuehler B, Gatzioufas Z, Hafezi F. Femtosecond laser versus mechanical microkeratome-assisted flap creation for LASIK: a prospective, randomized, paired-eye study. Clin Ophthalmol. 2014 Sep 22;8:1883-9. doi: 10.2147/OPTH.S68124. eCollection 2014.
PubMed 25284975Tomita M, Chiba A, Matsuda J, Nawa Y. Evaluation of LASIK treatment with the Femto LDV in patients with corneal opacity. J Refract Surg. 2012 Jan;28(1):25-30. doi: 10.3928/1081597X-20111213-01. Epub 2011 Dec 19.
PubMed 22185466Pietila J, Huhtala A, Makinen P, Uusitalo H. Flap characteristics, predictability, and safety of the Ziemer FEMTO LDV femtosecond laser with the disposable suction ring for LASIK. Eye (Lond). 2014 Jan;28(1):66-71. doi: 10.1038/eye.2013.244. Epub 2013 Nov 15.
PubMed 24232315Pietila J, Huhtala A, Makinen P, Salmenhaara K, Uusitalo H. Laser-assisted in situ keratomileusis flap creation with the three-dimensional, transportable Ziemer FEMTO LDV model Z6 I femtosecond laser. Acta Ophthalmol. 2014 Nov;92(7):650-5. doi: 10.1111/aos.12333. Epub 2013 Dec 26.
PubMed 24373615Porela-Tiihonen S, Kaarniranta K, Kokki M, Purhonen S, Kokki H. A prospective study on postoperative pain after cataract surgery. Clin Ophthalmol. 2013;7:1429-35. doi: 10.2147/OPTH.S47576. Epub 2013 Jul 15.
PubMed 23885165
Study at a glance
From the registry record, last updated by the sponsor on 11 Jun 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Precision of 2D vs 3D Low Energy Femto-LASIK: Intraoperative and Postoperative OCT-based Study
- ClinicalTrials.gov ID
- NCT04426175
- Acronym / sponsor ID
- CPFEM-0007-DE
- Conditions
- Myopia, Astigmatism
- Keywords
- Femtosecond Laser Assisted Laser in Situ Keratomileusis, LASIK, FEMTO LDV Z8
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 13 participants (actual)
- Lead sponsor
- Zentrumsehstarke HamburgIndustry (pharma, biotech, devices)
- Study start
- 5 Dec 2019 (actual)
- Primary completion
- 23 Apr 2020 (actual)
- Study completion
- 23 Apr 2020 (actual)
- First posted
- 11 Jun 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The aim of this study was to test the hypothesis that OCT-guided 110 µm targeted flaps will result in accurate, predictable, and precise thickness flaps, with low complication rates when performed and compared using both 2D and 3D flap geometry applications and how it correlated to visual experience and quality of life responses during the early postoperative period.
Detailed description
It has been postulated that it is possible with the Ziemer Femtosecond LDV laser system to create reproducible flaps in terms of thickness and predictability. The aim of this study was to test the hypothesis that OCT-guided 110 µm targeted flaps will result in accurate, predictable, and precise thickness flaps, with low complication rates when performed and compared using both 2D and 3D flap geometry applications. Patient-reported outcomes are increasingly incorporated into clinical trials as they provide access to valuable information on the physical experience of the patient during and after the treatment. A questionnaire will therefore also be introduced in this study to evaluate how well self-reported pain, visual experience, and quality of life responses are correlated with flap geometries in both groups during the early postoperative period. The study holds direct medical benefit to the patient in this that they received an immediate improvement in his/her unaided vision. Moreover, the patient's participation contributes to the medical knowledge about the use of femtosecond lasers for refractive surgery, in particular in view of the use of intraoperative OCT visualization tools. The patients will gain access to the newest technology available for refractive surgery namely a low pulse energy high-frequency femtosecond laser.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| 2D LASIK | Experimental | Device: 2D and 3D cutting method using a low energy Femtosecond laser LDV Z8 for LASIK flap cuttingWith the 2D method, the flap resection is created in a planar mode (xy-plane), without vertical cut, at the requested depth. |
| 3D LASIK | Experimental | Device: 2D and 3D cutting method using a low energy Femtosecond laser LDV Z8 for LASIK flap cuttingWith the 3D method, the flap resection is done in a three-dimensional mode, at the requested depth, with the requested diameter and the desired border (side cut) angle |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Key inclusion criteria as described by the German Commission for Refractive Surgery (KRC) are:
- The recommended range of application for the correction of myopia is up to -8.00 D and for the correction of astigmatism up to 5.00 D.
- The limited for LASIK correction of myopia is up to -10.00 D and correction of astigmatism up to 6.00 D. If myopic astigmatism is to be corrected, the values for myopia and astigmatism must be added together.
- The recommended range for correction of hyperopia is up to 3.00 D. Up to 4.00 D is the range of limited application for hyperopia.
- Age ≥18 years with stable eyesight for over 12 months.
Key exclusion criteria (11 listed)
- Key exclusion criteria as described by the German Commission for Refractive Surgery (KRC):
- preoperative corneal thickness less than 480 μm
- predicted stromal thickness under the flap after ablation of less than 250 μm
- chronic progressive corneal disease and forme fruste keratoconus
- surgery before the age of 18 years
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| 2D and 3D cutting method using a low energy Femtosecond laser LDV Z8 for LASIK flap cutting2D and 3D cutting methods were randomly used in same subjects | Device | 2D LASIK, 3D LASIK |
Primary outcome
Predictability of central flap thickness in OCT-controlled 110 µm LASIK
Time frame: 1 month postoperatively
Analyze central flap thickness in OCT-controlled 110 µm LASIK and to report on intended versus achieved flap thickness of one group with a 2D flap geometry in one eye and another group with a 3D flap geometry in the contralateral eye. All OCT measurements will be done in micron metres (µm).
7 secondary outcomes
Comparison of intraoperative flap thickness with pre- and postoperative results
Time frame: 1 week, 1 month
Postoperative planarity
Time frame: 1 week, 1 month
Intraoperative flap morphology
Time frame: During surgery
Postoperative flap properties
Time frame: 1 week, 1 month
Visual outcomes
Time frame: 1 day, 1 week, 1 month
Patient reported Outcomes: early recovery period
Time frame: 1 day, 2Day, 1 week follow up
Complications
Time frame: Intra- and postoperatively up to 1 month follow up
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 11 Jun 2020.
- Background: PubMed 27022236Huhtala A, Pietila J, Makinen P, Uusitalo H. Femtosecond lasers for laser in situ keratomileusis: a systematic review and meta-analysis. Clin Ophthalmol. 2016 Mar 7;10:393-404. doi: 10.2147/OPTH.S99394. eCollection 2016.
- Background: PubMed 30977320Eldaly ZH, Abdelsalam MA, Hussein MS, Nassr MA. Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study. Korean J Ophthalmol. 2019 Apr;33(2):113-121. doi: 10.3341/kjo.2018.0035.
- Background: PubMed 25284975Pajic B, Vastardis I, Pajic-Eggspuehler B, Gatzioufas Z, Hafezi F. Femtosecond laser versus mechanical microkeratome-assisted flap creation for LASIK: a prospective, randomized, paired-eye study. Clin Ophthalmol. 2014 Sep 22;8:1883-9. doi: 10.2147/OPTH.S68124. eCollection 2014.
- Background: PubMed 22185466Tomita M, Chiba A, Matsuda J, Nawa Y. Evaluation of LASIK treatment with the Femto LDV in patients with corneal opacity. J Refract Surg. 2012 Jan;28(1):25-30. doi: 10.3928/1081597X-20111213-01. Epub 2011 Dec 19.
- Background: PubMed 24232315Pietila J, Huhtala A, Makinen P, Uusitalo H. Flap characteristics, predictability, and safety of the Ziemer FEMTO LDV femtosecond laser with the disposable suction ring for LASIK. Eye (Lond). 2014 Jan;28(1):66-71. doi: 10.1038/eye.2013.244. Epub 2013 Nov 15.
- Background: PubMed 24373615Pietila J, Huhtala A, Makinen P, Salmenhaara K, Uusitalo H. Laser-assisted in situ keratomileusis flap creation with the three-dimensional, transportable Ziemer FEMTO LDV model Z6 I femtosecond laser. Acta Ophthalmol. 2014 Nov;92(7):650-5. doi: 10.1111/aos.12333. Epub 2013 Dec 26.
- Background: PubMed 23885165Porela-Tiihonen S, Kaarniranta K, Kokki M, Purhonen S, Kokki H. A prospective study on postoperative pain after cataract surgery. Clin Ophthalmol. 2013;7:1429-35. doi: 10.2147/OPTH.S47576. Epub 2013 Jul 15.
- Individual participant dataSharing planned: No. It is not clear yet to what extend IPD will be implemented. Patient privacy and confidentiality are the most important factors to consider. We consider sharing limited information upon request.
Related trials for Myopia
RecruitingPhase 3
A RCT of Spectacles With Aspherical Lenslets or 0.05% Atropine for Myopia Control
Myopia
Active, not recruitingPhase 4
Odyssey Evaluation in Post LASIK Patients
Cataract
Recruiting
Evaluation of Orthokeratology Lenses With a 5MM Optic Zone Diameter
Myopia, Astigmatism
Recruiting
Wavelength Intervention for Nearsighted Kids
Myopia
Not yet recruiting
SmoothCore Orthokeratology Plus M.O.V.E. Lenses vs. M.O.V.E. Lenses Alone for Myopia Control in Children With High Myopia
High Myopia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Stephan Linke, MD principal investigator
Zentrumsehstarke Hamburg
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing 2D and 3D cutting method using a low energy Femtosecond laser LDV Z8 for LASIK flap cutting in people with Myopia and Astigmatism, run by Zentrumsehstarke Hamburg at 1 site in Germany.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 11 Jun 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Predictability of central flap thickness in OCT-controlled 110 µm LASIK (time frame: 1 month postoperatively). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04426175, which also lists 7 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Jun 2020.