Coronary Artery DiseaseSPIRIT 48NCT04282148
Abbott Next Generation Drug Eluting Stent 48mm Study
A study testing ABT NG DES 48 EECSS in people with Coronary Artery Disease, run by Abbott Medical Devices at 25 sites in 3 countries.
Trial summary
The purpose of this SPIRIT 48 study is to evaluate the safety and effectiveness of the ABT NG DES 48 in improving coronary artery luminal diameter in subjects with coronary artery disease (CAD) due to de novo native coronary artery long lesions. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Coronary Artery Disease
- What is being tested?
- ABT NG DES 48 EECSS
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 107 participants
- Where
- 25 sitesin 3 countries
- Study dates
- 17 Jun 2020to 17 Sep 2023
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
General Inclusion Criteria:
- Subject must be at least 18 years of age.
- Subject or a legally authorized representative must provide written informed consent prior to any study related procedure, per site requirements.
- Subject must have evidence of myocardial ischemia (e.g., unstable angina, post-infarct angina, stable angina or silent ischemia) suitable for non-emergent PCI. Subject with stable angina or silent ischemia must have objective sign of ischemia as suggested by one of the following,
- Abnormal stress or imaging stress test
- Abnormal computed tomography-fractional flow reserve (CT-FFR)
- Stenosis by visual estimation ≥ 70%
- Abnormal pressure-derived indexes (FFR, instantaneous wave-free ratio [iFR], or relative flow reserve [RFR])
- Subject must be an acceptable candidate for coronary artery bypass graft (CABG) surgery.
- Subject must agree not to participate in any other clinical study for a period of one year following the index procedure.
Angiographic Inclusion Criteria:
- Only one de novo target lesion in native coronary artery is allowed to be treated with the investigational stent.
- One additional non-target lesion can be treated if it is located in a different epicardial coronary vessel and NOT in left main coronary artery. The non-target lesion must be treated first and must be deemed an angiographic success.
- The target lesion must be located in a native coronary artery with:
- Visually estimated reference vessel diameter (RVD) of ≥ 2.5 mm and ≤ 4.25 mm.
- Visually estimated lesion length of > 32 mm and ≤ 44 mm, and able to be covered by a single ABT NG DES 48.
- Multiple focal de novo lesions in an epicardial coronary vessel are allowed if the lesions can be covered by one stent. Multiple focal de novo lesions will be counted as a single lesion.
- Visually estimated diameter stenosis of > 50% and < 100% with a Thrombolysis in Myocardial Infarction (TIMI) flow of ≥ 1
- Stable angina or silent ischemia subjects must have stenosis ≥ 70%, or abnormal pressure-derived physiological indices (FFR, iFR, or RFR), unless abnormal stress or imaging stress test is evidenced.
General Exclusion Criteria:
- Subject has known hypersensitivity or contraindication to device material and its degradants (everolimus, cobalt, chromium, nickel, tungsten, acrylic and fluoropolymers, etc.), or has known contrast sensitivity.
- Subject has known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, P2Y12 inhibitors (clopidogrel /prasugrel /ticagrelor), and therefore cannot be adequately pre-medicated.
- Subject has a planned surgery or procedure necessitating discontinuation of aspirin or P2Y12 inhibitor within 12 months following index procedure.
- Subject is receiving or will require chronic anticoagulation therapy (e.g., coumadin, dabigatran, apixaban, rivaroxaban or any other agent for any reason).
- Pregnant or nursing subjects and those who plan pregnancy in the period up to 1 year following index procedure. Female subjects of child-bearing potential must have a negative pregnancy test done within 7 days prior to the index procedure per site standard test.
- Subject had an acute myocardial infarction (AMI) within 48 hours of the index procedure with either of the situations below:
- The subject is currently experiencing clinical symptoms consistent with new onset AMI, such as nitrate-unresponsive prolonged chest pain with ischemic electrocardiogram (ECG) changes
- Elevated cardiac biomarker values have not returned to within normal limits at the time of index procedure.
- Subject has a left ventricular ejection fraction (LVEF) < 30% within 3 months prior to the index procedure, that was documented by any method.
- Subject is expected to require percutaneous mechanical cardiac support at the index procedure.
- Prior PCI within the target vessel during the last 12 months prior to consent.
- Prior PCI within the non-target vessel or any peripheral intervention during the last 30 days prior to consent.
- At the index procedure, subject is identified to require planned stenting procedure (including staged procedures) or CABG after the index procedure.
- Subject has received a solid organ transplant which is functioning or is active on a waiting list for any solid organ transplants with expected transplantation within 24 months.
- Subject has a malignancy that is not in remission.
- Subject is receiving immunosuppressant therapy or has known life-threatening immunosuppressive or severe autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus, etc.). Note: corticosteroids are not included as immunosuppressant therapy, diabetes mellitus is not regarded as autoimmune disease
- Subject has previously received or is scheduled to receive radiotherapy to a coronary artery (vascular brachytherapy), or the chest/mediastinum.
- Subject has a platelet count < 100,000 cells/mm^3 or > 700,000 cells/mm^3.
- Subject has renal insufficiency as defined as an estimated glomerular filtration rate (GFR) < 30 ml/min/1.73m^2 or dialysis at the time of consent.
- Subject is high risk of bleeding for any reason; has a history of bleeding diathesis or coagulopathy; has had a significant gastro-intestinal or significant urinary bleed within the past six months.
- Subject has had a cerebrovascular accident or transient ischemic neurological attack (TIA) within the past 6 months, or any prior intracranial bleed, or any permanent neurologic defect, or any known intracranial pathology (e.g. aneurysm, arteriovenous malformation, etc.).
- Subject has extensive peripheral vascular disease that precludes safe 6 French sheath insertion. Note: femoral arterial disease does not exclude the subject if radial access may be used.
- Subject has life expectancy < 2 years.
- Subject is, in the opinion of the Investigator or designee, unable to comply with the requirements of the study protocol or is unsuitable for the study for any reason. This includes completion of Subject Reported Outcome instruments.
- Subject is currently participating in another clinical investigation (except for non-invasive observational studies) that has not yet completed its primary endpoint.
- Subject intends to participate in another investigational drug or device clinical investigation (except for non-invasive observational studies) within 12 months after the index procedure.
- Subject has other medical illness (e.g., cancer or congestive heart failure) or known history of substance abuse (alcohol, cocaine, heroin etc.) that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy less than 2 years.
- Presence of other anatomic or comorbid conditions, or other medical, social, or psychological conditions that, in the investigator's opinion, could limit the subject's ability to participate in the clinical investigation or to comply with follow-up requirements, or impact the scientific soundness of the clinical investigation results.
- Subject has active symptoms and/or a positive test result of COVID-19 or other rapidly spreading novel infectious agent within the prior 2 months.
Angiographic Exclusion Criteria:
- Target lesion/vessel meets any of the following criteria:
- Prevents complete angioplasty balloon (plain old balloon angioplasty [POBA], scoring balloon, or cutting balloon) inflation, such as:
- Heavy calcified lesion
- Requires additional device for lesion preparation (e.g. rotablator or laser).
- Anatomy proximal to or within the lesion that prevents proper placement of delivery system:
- Extreme angulation (≥ 90°) proximal to or within the target lesion.
- Excessive tortuosity (≥ two 45° angles) proximal to or within the target lesion.
- Involves a bifurcation of which the side branch will be jailed by the struts and requiring side branch pre-dilatation by Kissing Balloon Technique, and/or stenting
- Is located:
- In left main or there is a ≥30% diameter stenosis in the left main (unless the left main lesion is a protected left main (i.e. a patent bypass graft to the left anterior descending coronary artery [LAD] and/or left circumflex coronary artery [LCX] arteries is present), and there is no intention to treat the protected left main lesion.
- Within 3 mm of the origin of the LAD or LCX.
- Within 3 mm of aorto-ostial right coronary artery (RCA).
- In a bypass graft or distal to anastomotic site of bypass graft.
- With total occlusion (TIMI flow 0), prior to crossing with the wire.
- Contains thrombus
- The subject has been previously treated with a stent within 1-year prior to the index procedure such that the ABT NG DES 48 would need to cross the stent to reach the target lesion.
- Unsuccessful target lesion pre-dilatation, defined as the presence of one or more of the following:
- Failed for a full inflation of the pre-dilatation balloon.
- TIMI flow grade <3 (per visual estimation).
- Any angiographic complication (e.g. distal embolization, no-reflow)
- Any dissection National Heart, Lung, and Blood Institute (NHLBI) grade D-F.
- Any chest pain lasting > 5 minutes.
- Any ST-segment depression or elevation lasting > 5 minutes.
- Side branch requires additional dilatation/stenting caused by plaque shift, carina shift or may require additional dilatation/stenting after stent implantation, per the operator's assessment.
- Non-target lesion meets any of the following criteria:
- Is located in the target vessel
- Is located in the left main location
- Is restenotic from a previous stent implantation
- Is located within a saphenous vein graft or an arterial graft
- Is with a TIMI flow 0 (total occlusion) prior to guide wire crossing
- Involves a complex bifurcation that needs two-stent strategy.
- Treatment of non-target lesion is not deemed successful.
Note: A successful treatment is defined as a treatment resulted in a mean lesion diameter stenosis < 30% in 2 near-orthogonal projections with TIMI 3 flow, as visually assessed by the physician, without the occurrence of prolonged chest pain or ECG changes consistent with MI.
Trial locations and contacts
25 sites in 3 countries.
25 sites in 3 countries
United States18 sites
Massachusetts General Hospital
Boston, Massachusetts, 02114
The Lindner Center
Cincinnati, Ohio, 45219
Baylor Scott & White Heart & Vascular Hospital
Dallas, Texas, 75226
The Cardiac & Vascular Institute Research Foundation, LLC
Gainesville, Florida, 32605
Shands at the University of Florida
Gainesville, Florida, 32610
Greenville Health System
Greenville, South Carolina, 29605
Pinnacle Health System
Harrisburg, Pennsylvania, 17105
Scripps Memorial Hospital - La Jolla
La Jolla, California, 92037
Minneapolis Heart Institute
Minneapolis, Minnesota, 55407
St. Patrick Hospital
Missoula, Montana, 59802
Mount Sinai Hospital
New York, New York, 10019
The Heart Hospital Baylor Plano
Plano, Texas, 75093
UCLA Medical Center Santa Monica
Santa Monica, California, 90404
HonorHealth
Scottsdale, Arizona, 85258
St. Vincent Mercy Medical Center
Toledo, Ohio, 43608
North Mississippi Medical Center
Tupelo, Mississippi, 38801
Via Christi Regional Medical Center - St. Francis Campus
Wichita, Kansas, 67214
Cardiovascular Research Institute of Kansas
Wichita, Kansas, 67226
Taiwan4 sites
Kaohsiung Chang Gung Memorial Hospital
Kaohsiung City, South Taiwan, 83301
Chang Gung Memorial Hospital
Linkou District, North Taiwan, 333
National Taiwan University Hospital
Taipei, North Taiwan, 10002
Cheng Hsin General Hospital
Taipei, North Taiwan, 112
Australia3 sites
The Prince Charles Hospital
Chermside, Queensland, 4032
Liverpool Hospital
Liverpool, New South Wales, 2170
Royal North Shore Hospital
St Leonards, 2065
About this study
Official title: A Clinical Investigation to Assess the Abbott Next Generation Drug Eluting Stent 48mm Everolimus Eluting Coronary Stent System (EECSS) in Treatment of de Novo Native Coronary Artery Disease
The purpose of this SPIRIT 48 study is to evaluate the safety and effectiveness of the ABT NG DES 48 in improving coronary artery luminal diameter in subjects with coronary artery disease (CAD) due to de novo native coronary artery long lesions.
Read the detailed description
The SPIRIT 48 mm study is a prospective, single arm, open-label, multi-center global (US and outside of US) clinical investigation to evaluate the safety and effectiveness of the ABT Next Generation Drug Eluting Stent 48 mm everolimus-eluting coronary stent system (EECSS) (called "ABT NG DES 48") in up to 107 subjects at up to 33 sites globally. The clinical outcomes from the SPIRIT 48 study will be compared to a performance goal (PG) established using historical control data from the SPIRIT Prime Long Lesion Registry. This clinical investigation will be conducted under an investigational device exemption (IDE) and is intended to support market approval of the ABT NG DES 48 in the United States.
- Conditions
- Coronary Artery Disease
- Being tested
- ABT NG DES 48 EECSS
- Keywords
- De novo native coronary artery long lesions, ABT NG DES 48 EECSS, ABT-CIP-10321, Coronary artery luminal diameter, SPIRIT 48
- Medical subject headings
- Coronary Artery Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
ABT NG DES 48 EECSSDevice
Each participant will receive ABT NG DES 48 EECSS with appropriate diameter
| Study group | Role | What they receive |
|---|---|---|
| ABT NG DES 48 EECSS | Experimental | Participants will receive ABT NG DES 48 EECSS device Receives: Device: ABT NG DES 48 EECSS |
What is being measured
The primary outcome is the main question the study is designed to answer.
Kaplan-Meier Estimate of 1-Year Target Lesion Failure (TLF)
Target Lesion Failure (TLF) is defined as the composite rate of cardiac death (CD), target vessel myocardial infarction [TV-MI] (per SCAI MI definition), and clinically indicated target lesion revascularization [CI-TLR])
Measured: 1 year
Secondary outcomes (5)
Number of Participants With Target Lesion Failure (TLF)
Target Lesion Failure (TLF) is defined as the composite rate of cardiac death (CD), target vessel myocardial infarction [TV-MI] (per SCAI MI definition), and clinically indicated target lesion revascularization [CI-TLR])
Measured: In-hospital 6 to 12 hours post procedure
Number of Participants With Target Lesion Failure (TLF)
Target Lesion Failure (TLF) is defined as the composite rate of cardiac death (CD), target vessel myocardial infarction [TV-MI] (per SCAI MI definition), and clinically indicated target lesion revascularization [CI-TLR])
Measured: 30 days
Number of Participants With Target Lesion Failure (TLF)
Target Lesion Failure (TLF) is defined as the composite rate of cardiac death (CD), target vessel myocardial infarction [TV-MI] (per SCAI MI definition), and clinically indicated target lesion revascularization [CI-TLR])
Measured: 180 days
Number of Participants With Target Lesion Failure (TLF)
Target Lesion Failure (TLF) is defined as the composite rate of cardiac death (CD), target vessel myocardial infarction [TV-MI] (per SCAI MI definition), and clinically indicated target lesion revascularization [CI-TLR])
Measured: 1 year
Number of Participants With Target Lesion Failure (TLF)
Target Lesion Failure (TLF) is defined as the composite rate of cardiac death (CD), target vessel myocardial infarction [TV-MI] (per SCAI MI definition), and clinically indicated target lesion revascularization [CI-TLR]).
Measured: 2 year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted24 Feb 2020
- Study start17 Jun 2020
- Primary completion5 Oct 2022
- Study completion17 Sep 2023
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- More trials run by Abbott Medical DevicesThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Prospective, multi-center, global (US and OUS)
- Masking
- None (open label)
- Enrolment
- 107 participants (actual)
Sponsor and investigators
- Lead sponsor
- Abbott Medical Devices
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Chi-Jen Chang, MD, Principal investigator, Chang Gung Memorial HospitalKi E Park, MD, Principal investigator, University of Florida/Malcom Randall VAMC
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04282148
- Sponsor's protocol ID
- ABT-CIP-10321
- Acronym
- SPIRIT 48
- Status last verified
- Jan 2025
- First submitted
- 18 Feb 2020
- Last updated
- 8 Jan 2025
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 8 Jan 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Clinical Investigation to Assess the Abbott Next Generation Drug Eluting Stent 48mm Everolimus Eluting Coronary Stent System (EECSS) in Treatment of de Novo Native Coronary Artery Disease
- ClinicalTrials.gov ID
- NCT04282148
- Acronym / sponsor ID
- SPIRIT 48 / ABT-CIP-10321
- Conditions
- Coronary Artery Disease
- Keywords
- De novo native coronary artery long lesions, ABT NG DES 48 EECSS, ABT-CIP-10321, Coronary artery luminal diameter, SPIRIT 48
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 107 participants (actual)
- Lead sponsor
- Abbott Medical DevicesIndustry (pharma, biotech, devices)
- Study start
- 17 Jun 2020 (actual)
- Primary completion
- 5 Oct 2022 (actual)
- Study completion
- 17 Sep 2023 (actual)
- First posted
- 24 Feb 2020 (actual)
- Results
- Posted 12 Feb 2024
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this SPIRIT 48 study is to evaluate the safety and effectiveness of the ABT NG DES 48 in improving coronary artery luminal diameter in subjects with coronary artery disease (CAD) due to de novo native coronary artery long lesions.
Detailed description
The SPIRIT 48 mm study is a prospective, single arm, open-label, multi-center global (US and outside of US) clinical investigation to evaluate the safety and effectiveness of the ABT Next Generation Drug Eluting Stent 48 mm everolimus-eluting coronary stent system (EECSS) (called "ABT NG DES 48") in up to 107 subjects at up to 33 sites globally. The clinical outcomes from the SPIRIT 48 study will be compared to a performance goal (PG) established using historical control data from the SPIRIT Prime Long Lesion Registry. This clinical investigation will be conducted under an investigational device exemption (IDE) and is intended to support market approval of the ABT NG DES 48 in the United States.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Prospective, multi-center, global (US and OUS)
| Arm | Type | Receives |
|---|---|---|
| ABT NG DES 48 EECSS | Experimental | Device: ABT NG DES 48 EECSSParticipants will receive ABT NG DES 48 EECSS device |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| ABT NG DES 48 EECSSEach participant will receive ABT NG DES 48 EECSS with appropriate diameter | Device | ABT NG DES 48 EECSS |
Primary outcome
Kaplan-Meier Estimate of 1-Year Target Lesion Failure (TLF)
Time frame: 1 year
Target Lesion Failure (TLF) is defined as the composite rate of cardiac death (CD), target vessel myocardial infarction [TV-MI] (per SCAI MI definition), and clinically indicated target lesion revascularization [CI-TLR])
5 secondary outcomes
Number of Participants With Target Lesion Failure (TLF)
Time frame: In-hospital 6 to 12 hours post procedure
Number of Participants With Target Lesion Failure (TLF)
Time frame: 30 days
Number of Participants With Target Lesion Failure (TLF)
Time frame: 180 days
Number of Participants With Target Lesion Failure (TLF)
Time frame: 1 year
Number of Participants With Target Lesion Failure (TLF)
Time frame: 2 year
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 8 Jan 2025.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: No
Related trials for Coronary Artery Disease
Not yet recruitingPhase 1/2
EDIT-401 in Adults Who Require Additional Lowering of Low-Density Lipoprotein Cholesterol (LDL-C)
Heterozygous Familial Hypercholesterolemia (HeFH)
Active, not recruitingPhase 3
Coronary Computed Tomography Study to Assess the Effect of Inclisiran in Addition to Maximally Tolerated Statin Therapy on Atherosclerotic Plaque Progression in Participants With a Diagnosis of Non-obstructive Coronary Artery Disease Without Previous Cardiovascular Events
Coronary Artery Disease
RecruitingObservational study
Characterization of Patients With Uncommon Presentations and/or Uncommon Diseases Associated With the Cardiovascular System
Metabolic Disease, Obesity
Active, not recruiting
Troponin in Acute Chest Pain to Risk Stratify and Guide EffecTive Use of Computed Tomography Coronary Angiography
Coronary Artery Disease
Recruiting
A Prospective, Multicenter, Randomized Controlled Trial to Investigate the Value of Coronary CT Angiography in the Understanding and Management of Coronary Calcium (The Optimal Trial)
Cardiovascular Diseases, Myocardial Ischemia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Chi-Jen Chang, MD principal investigator
Chang Gung Memorial Hospital
Ki E Park, MD principal investigator
University of Florida/Malcom Randall VAMC
25 sites in 3 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing ABT NG DES 48 EECSS in people with Coronary Artery Disease, run by Abbott Medical Devices at 25 sites in 3 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 8 Jan 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 25 sites in United States, Taiwan, Australia. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 12 Feb 2024). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Kaplan-Meier Estimate of 1-Year Target Lesion Failure (TLF) (time frame: 1 year). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Jan 2025.