Failed Back Surgery SyndromeNCT04216992
Value of Three-dimensional Rotational Epidurography on Percutaneous Epidural Adhesiolysis
An observational study of Failed Back Surgery Syndrome and Spinal Stenosis, run by Tri-Service General Hospital (TSGH) at 1 site in Taiwan.
Trial summary
Conventional epidurography (CE) is thought to have insufficient usefulness on percutaneous epidural adhesiolysis (PEA). The investigators aimed to evaluate the association between the outcome of PEA and three dimensional-rotational epidurography (3D-RE). Read more about this study
- Who is it for?
- Ages Up to 20 years
- Conditions the study is for
- Failed Back Surgery Syndrome, Spinal Stenosis
- What is being tested?
- Cone beam computed tomography
- Type of treatment
- Medical device
- How many people
- 30 participants
- Where
- 1 siteTaiwan
- Study dates
- 4 Jan 2018to 6 Dec 2019
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Up to 20 years
- All sexes
- Child, Adult
Study population: Patients who had FBSS or SS with unilateral radiculopathy underwent PEA.
Who may be able to join
- FBSS or SS with unilateral radiculopathy.
- History of discogenic or radicular symptoms refractory to conservative treatments and epidural steroid injection for a minimum of 6 weeks.
- The PEA was standardized to all patients receiving the procedure.
- Each patient received an epidural injection, and if the symptoms persisted or the relief was insufficient, the patient received PEA >6-week interval between the epidural steroid injection.
- Positive provocative test during PEA was used to confirm the affected spinal level.
- All patients underwent CE before and after PEA; and 3D-RE after PEA.
Who cannot join
- History of spinal surgery and those with cauda equina syndrome
- Bleeding diathesis
- Associated somatic or psychiatric disease
- Vertebral fractures
- Pregnancy
- Tumors
Show all 9Show fewer
- Other underlying systemic diseases that could significantly influence the procedural outcomes were excluded.
- Bilateral symptoms
- Did not react to the provocation during PEA
Trial locations and contacts
1 site in 1 country.
Taiwan1 site
No. 325, Sec. 2, Cheng-kung Rd., Neihu 114
Taipei, Taiwan, R.o.c., 886
About this study
Official title: Institutional Review Board of Tri-Service General Hospital, National Defense Medical Center
Conventional epidurography (CE) is thought to have insufficient usefulness on percutaneous epidural adhesiolysis (PEA). The investigators aimed to evaluate the association between the outcome of PEA and three dimensional-rotational epidurography (3D-RE). The investigators performed 30 PEA in 26 patients, and evaluated their post-PEA image findings. Two independent clinicians categorized and recorded the occurrence of contrast at intra-canal ventral and extra-foraminal regions on CE; and contrast at dorsal canal (DC), ventral canal (VC), dorsal foramen (DF), and ventral foramen (VF) on 3D-RE. Reproducibility was assessed using intra-class correlation coefficients (ICCs). The symptom relief after one month for the patients receiving PEA and the contrast distribution patterns of CE and 3D-RE and were determined.
Read the detailed description
Patient Selection. This prospective study protocol was approved by the ethics committee, and informed consent was obtained from all subjects. The investigators analyzed the medical and radiographic records included patients who underwent lumbar PEA procedures at a single university hospital. The inclusion criterion was FBSS and SS with unilateral radiculopathy. All patients reported a history of discogenic or radicular symptoms refractory to conservative treatments and epidural steroid injection for a minimum of 6 weeks. Diagnoses were established using magnetic resonance imaging (MRI) and/or computed tomography (CT) performed before PEA. The PEA was standardized to all patients receiving the procedure. Each patient received an epidural injection, and if the symptoms persisted or the relief was insufficient, the patient received PEA >6-week interval between the epidural steroid injection. Positive provocative test during PEA was used to confirm the affected spinal level [11]. All patients underwent CE before and after PEA; and 3D-RE after PEA. Patients with a history of spinal surgery and those with cauda equina syndrome, bleeding diathesis, associated somatic or psychiatric disease, vertebral fractures, pregnancy, and tumors or other underlying systemic diseases that could significantly affect the procedural outcomes were excluded. The patients had bilateral symptoms and did not react to the provocation during PEA were also excluded. All procedures were performed by one of the authors (YCH) using the same procedural protocol.
PEA Procedure. A standard PEA procedure was used to lyse adhesions and achieve nerve blockades in all patients, as previously described [1,2]. A 1-day standardized protocol was followed. The patient was placed on a radiolucent table in the prone position, and the procedure was performed under fluoroscopic guidance. The coccygeal and sacral regions were disinfected with 10% Betadine, and the surgical site was draped in the usual aseptic manner. The sacral hiatus was anesthetized with 1% xylocaine. Then, a 13.6-G Coaxial needle was introduced into the epidural space below the level of S3 with a combined use of US-guidance and fluoroscopy insurance. The US was provided using a scanner (Xario 100; Toshiba, Tokyo, Japan) with a 7~18 MHz linear transducer (PLU-1204BT). A total of 0.5 mL of the contrast agent (Omnipaque, GE Healthcare, Ireland) was instilled to confirm the epidural space. Both anteroposterior, right-oblique, left-oblique, and lateral fluoroscopic views were obtained. The investigators also assessed the development of any adverse reactions. On confirmation of the target for PEA, an angiographic catheter (Cobra 4-Fr; Cordis, USA) and/or coaxial supporting catheter (Chiba 6-Fr; Cook, USA) was gently inserted toward the target site. Once it reached the target site, a second CE was obtained by injecting 3 mL of the contrast agent for the identification of filling defects or cutoff signs surrounding the target area. The investigators choose the target nerve roots for PEA by clinical dermatome involvement and provocation tests during PEA. The catheter tip was positioned at the ventral epidural space of the target site, and in the case of foraminal diseases, was placed at the opening of the foramen [12]. When the tip of the catheter touched the target site or the contrast agent exerted pressure on the lesion, patients were asked to report provoked symptoms [4]. According to the surgical records, they frequently reported pain similar to what they had been suffering. Both mechanical and fluid adhesiolysis were performed. The former was achieved through pushing, pulling, and rotating movements of the catheter, while the latter was achieved by the injection of 0.9% normal saline (10 mL). Following PEA, a third CE and 3D-RE was obtained using 3 mL of the contrast agent. All CE and 3D-RE images were saved in the Digital Imaging and Communications in Medicine format for future analysis, and the CE and 3D-RE after PEA was used for analysis in our study. Finally, a 40 mg triamcinolone acetonide (YungShin, Taichung, Republic of China) was slowly injected.
3D-RE technique. After performing PEA, 3D-RE are obtained on a commercial digital bi-plane angiography system (Allura Xper, Philips). A 240-degree rotation forward and backward of the tube-camera unit around the patient's longitudinal axis within 4 seconds is performed by using an acquisition matrix of 1024 x 1024 pixels. The forth and back rotation results in 120 radiographs. Raw data were automatically sent to a dedicated workstation (Philips Xtra vision workstation), where the rotational projection images are prepared for computed 3D reconstruction. 2D radiographs are used to determine the volume of interest. After correction of gain and distortion, a 3D data set is calculated, resulting in 512 transverse CT-equivalent sections. Depending on the initially chosen volume of interest, the voxel size varies from 0.1 to 0.6 mm. The investigators used a resolution of 0.14-mm voxel size, which resulted in a 3D cuboid of 25 x 19 x 25 cm.
Reconstruction time was 30 seconds. Detailed information regarding technical performance and reconstruction procedure has been reported [13]. Postprocessing techniques provided by the software included real-time 3D volume rendering and multiplanar reformatting. Real-time 3D volume rendering creates a 3D model of the examined object. The software allows emphasizing bony structures or soft tissue by changing intensity, brightness, and opacity of different X-ray structures. Additionally, rotation of the 3D object in all directions is possible, as is a virtual stereoscopic view provided by the software in combination with special glasses. The multiplanar reformatting modus generates virtual sections according to the three main axes and free defined axes. The section planes can be freely chosen, and curved sectioning is also possible.
Conventional epidurography and 3D-RE Contrast Distributions. Post-PEA CE contrast patterns were defined and classified into 2 types according to the system proposed by Park et al. and Gupta et al.[4,6]: Limited intracanal ventral spread (ICV) and extended extraforaminal spread (EF) (Figure 1). The investigators defined the contrast distributions into 4 areas by post-PEA 3D-RE : Dorsal Canal (DC), contrast spread to the dorsal zone of the ipsilateral epidural space not extending to the neural foramen; Ventral Canal (VC), contrast spread to the ventral zone of the ipsilateral epidural space not extending to the neural foramen; Dorsal Foramen (DF), contrast spread to the dorsal zone of the ipsilateral epidural space extending to the neural foramen; Ventral Foramen (VF), contrast spread to the ventral zone of the ipsilateral epidural space extending to the neural foramen (Figure 2). The CE and 3D-RE images were analyzed and recorded by a musculoskeletal radiologist (Y.C.H.) and a surgeon (C.T.T.) who blinded to the results of the clinical data. The investigators made a consensus if there was discrepancy between the analyses of these images.
Data collection. All patients were clinically evaluated before and 1 month after PEA by a nurse specialized in pain management and blinded to the treatment details. The intensity of leg and back pain prior to PEA was assessed using a subjective visual analog scale (VAS) calibrated from 0 to 10 (0 = no pain and 10 = the worst pain imaginable). The patients' symptoms relief was rated using a Likert scale: 5 = greatly relief; 4 = some residual symptoms and symptoms relief > 50%; 3 = some residual symptoms and symptoms relief = 50%; 2 = residual symptoms and symptoms relief < 50%; 1 = no symptoms relief. For the comparison of clinical outcomes according to the symptoms relief, patients with grade 3, grade 4, and grade 5 were assigned to a group exhibiting >= 50% symptoms relief, while patients with grade 1 and grade 2 were assigned to a group exhibiting < 50% symptoms relief. Regarding the radiation exposure of PEA, simulations were performed with patient-specific input parameters (weight and length) and the actual 3D-RE system settings for each frame, including the automatic modulation of beam energy and dose level, and collimation. Effective dose (ED), which has been generally accepted single number index reflecting patient radiation risk, was subsequently calculated using the latest ICRP 103 weighing factors, published in 2007 [14].
StatisticalAnalysis. Age, the duration of discomfort prior to PEA, and VAS scores are expressed as means ±standard deviations. Demographic data within the two groups of greater symptoms relief and less were compared by using the chi-square test or the Fisher's exact test or unpaired t-test. Inter-reader agreement was evaluated using the intra-class correlation coefficients (ICCs), calculated according to Landis and Koch[15], for the contrast distribution of CE and 3D-RE. Simple linear regression analysis was used to determine the prediction of the outcome of PEA by the contrast distribution of CE and 3D-RE. All statistical analyses were performed using the Statistical Package for the Social Sciences software (SPSS Inc., Chicago, Illinois, USA). A P value of <0.05 was considered statistically significant.
- Conditions
- Failed Back Surgery Syndrome, Spinal Stenosis
- Being tested
- Cone beam computed tomography
- Keywords
- Cone beam, Computed tomography, Epidurography, Percutaneous epidural adhesiolysis
- Medical subject headings
- Failed Back Surgery Syndrome, Spinal Stenosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Cone beam computed tomographyDevice
The contrast agent (Omnipaque, GE Healthcare, Ireland) was instilled to confirm the epidural space. With use of a calibrated angiographic C-arm system and a postprocessing workstation, we acquired volume data sets from two dimensional digital projection images obtained to reconstruct the 3D-RE during a C-arm rotation around the patient axis.
| Study group | Role | What they receive |
|---|---|---|
| Three dimensional-rotational epidurography (3D-RE) | 3D-RE is obtained on a commercial digital bi-plane angiography system. Reconstruction time was 30 seconds. Detailed information regarding technical performance and reconstruction procedure has been reported. Postprocessing techniques provided by the software included real-time 3D volume rendering and multiplanar reformatting. Real-time 3D volume rendering creates a 3D model of the examined object. The software allows emphasizing bony structures or soft tissue by changing intensity, brightness, and opacity of different X-ray structures. Additionally, rotation of the 3D object in all directions is possible, as is a virtual stereoscopic view provided by the software in combination with special glasses. The multiplanar reformatting modus generates virtual sections according to the three main axes and free defined axes. The section planes can be freely chosen, and curved sectioning is also possible. Receives: Device: Cone beam computed tomography |
What is being measured
The primary outcome is the main question the study is designed to answer.
Symptoms change after PEA
For the comparison of clinical outcomes according to the symptoms change, the participants' symptoms change was rated using a Likert scale to defined two groups by exhibiting >= 50% symptoms change and < 50% symptoms change.
Measured: 1 month
Reproducibility of CE and 3D-RE
Inter-reader agreement was evaluated using the intra-class correlation coefficients (ICCs), calculated according to Landis and Koch, for the contrast distribution of CE and 3D-RE.
Measured: 1 month
Usefulness of 3D-RE for predicting the outcome of PEA
Simple linear regression analysis was used to determine the prediction of the outcome of PEA by the contrast distribution of CE and 3D-RE.
Measured: 3 months
Secondary outcomes (1)
Radiation exposure of PEA
Regarding the radiation exposure of PEA, simulations were performed with patient-specific input parameters (weight and length) and the actual 3D-RE system settings for each frame, including the automatic modulation of beam energy and dose level, and collimation. Effective dose (ED), which has been generally accepted single number index reflecting patient radiation risk, was subsequently calculated using the latest ICRP 103 weighing factors, published in 2007.
Measured: 1 month
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted3 Jan 2020
- Study start4 Jan 2018
- Primary completion24 Oct 2019
- Study completion6 Dec 2019
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (14)Papers the sponsor has linked to this study.
- Other trials for Failed Back Surgery SyndromeStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 30 participants (actual)
Sponsor and investigators
- Lead sponsor
- Tri-Service General Hospital (TSGH)
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, yi-chih HSU, Tri-Service General Hospital (TSGH)
- Investigators
- Yi-Chih Hsu, M.D., Study director, Department of Radiology Tri-Service General Hospital National Defense Medical Center
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04216992
- Sponsor's protocol ID
- 1-105-05-141
- Status last verified
- Jan 2020
- First submitted
- 28 Dec 2019
- Last updated
- 6 Jan 2020
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Undecided
Publications
Manchikanti L, Helm Ii S, Pampati V, Racz GB. Percutaneous adhesiolysis procedures in the medicare population: analysis of utilization and growth patterns from 2000 to 2011. Pain Physician. 2014 Mar-Apr;17(2):E129-39.
PubMed 24658484Gerdesmeyer L, Wagenpfeil S, Birkenmaier C, Veihelmann A, Hauschild M, Wagner K, Muderis MA, Gollwitzer H, Diehl P, Toepfer A. Percutaneous epidural lysis of adhesions in chronic lumbar radicular pain: a randomized, double-blind, placebo-controlled trial. Pain Physician. 2013 May-Jun;16(3):185-96.
PubMed 23703406Racz GB, Heavner JE, Trescot A. Percutaneous lysis of epidural adhesions--evidence for safety and efficacy. Pain Pract. 2008 Jul-Aug;8(4):277-86. doi: 10.1111/j.1533-2500.2008.00203.x. Epub 2008 May 23.
PubMed 18503627Park SH, Ji GY, Cho PG, Shin DA, Yoon YS, Kim KN, Oh CH. Clinical Significance of Epidurography Contrast Patterns after Adhesiolysis during Lumbar Percutaneous Epidural Neuroplasty. Pain Res Manag. 2018 Apr 1;2018:6268045. doi: 10.1155/2018/6268045. eCollection 2018.
PubMed 29808106Kim JH, Jung HJ, Nahm FS, Lee PB. Does improvement in epidurography following percutaneous epidural neuroplasty correspond to patient outcome? Pain Pract. 2015 Jun;15(5):407-13. doi: 10.1111/papr.12197. Epub 2014 Apr 21.
PubMed 24750546Gupta R, Singh S, Kaur S, Singh K, Aujla K. Correlation between Epidurographic Contrast Flow Patterns and Clinical Effectiveness in Chronic Lumbar Discogenic Radicular Pain Treated with Epidural Steroid Injections Via Different Approaches. Korean J Pain. 2014 Oct;27(4):353-9. doi: 10.3344/kjp.2014.27.4.353. Epub 2014 Oct 1.
PubMed 25317285Hong Park C, Ho Lee S. Epidurographic Findings Following Percutaneous Epidural Adhesiolysis Failed to Correlate with Level of Pain Reduction in Patients with Lumbar Spinal Stenosis. Pain Med. 2017 May 1;18(5):842-845. doi: 10.1093/pm/pnw244.
PubMed 27651508Shin JW. Is epidurogram a reliable tool for the diagnosis of epidural adhesion? Korean J Pain. 2012 Apr;25(2):133-4. doi: 10.3344/kjp.2012.25.2.133. Epub 2012 Apr 4. No abstract available.
PubMed 22514786Kufeld M, Claus B, Campi A, Lanksch WR, Benndorf G. Three-dimensional rotational myelography. AJNR Am J Neuroradiol. 2003 Aug;24(7):1290-3.
PubMed 12917114El-Sheik M, Heverhagen JT, Alfke H, Froelich JJ, Hornegger J, Brunner T, Klose KJ, Wagner HJ. Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: initial results. Radiology. 2001 Dec;221(3):843-9. doi: 10.1148/radiol.2213010606.
PubMed 11719688Manchikanti L, Boswell MV, Rivera JJ, Pampati VS, Damron KS, McManus CD, Brandon DE, Wilson SR. [ISRCTN 16558617] A randomized, controlled trial of spinal endoscopic adhesiolysis in chronic refractory low back and lower extremity pain. BMC Anesthesiol. 2005 Jul 6;5:10. doi: 10.1186/1471-2253-5-10.
PubMed 16000173Moon SH, Lee JI, Cho HS, Shin JW, Koh WU. Factors for Predicting Favorable Outcome of Percutaneous Epidural Adhesiolysis for Lumbar Disc Herniation. Pain Res Manag. 2017;2017:1494538. doi: 10.1155/2017/1494538. Epub 2017 Jan 26.
PubMed 28246488Wiesent K, Barth K, Navab N, Durlak P, Brunner T, Schuetz O, Seissler W. Enhanced 3-D-reconstruction algorithm for C-arm systems suitable for interventional procedures. IEEE Trans Med Imaging. 2000 May;19(5):391-403. doi: 10.1109/42.870250.
PubMed 11021683The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007;37(2-4):1-332. doi: 10.1016/j.icrp.2007.10.003.
PubMed 18082557
Study at a glance
From the registry record, last updated by the sponsor on 6 Jan 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Institutional Review Board of Tri-Service General Hospital, National Defense Medical Center
- ClinicalTrials.gov ID
- NCT04216992
- Acronym / sponsor ID
- 1-105-05-141
- Conditions
- Failed Back Surgery Syndrome, Spinal Stenosis
- Keywords
- Cone beam, Computed tomography, Epidurography, Percutaneous epidural adhesiolysis
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 30 participants (actual)
- Lead sponsor
- Tri-Service General Hospital (TSGH)University, hospital or other
- Study start
- 4 Jan 2018 (actual)
- Primary completion
- 24 Oct 2019 (actual)
- Study completion
- 6 Dec 2019 (actual)
- First posted
- 3 Jan 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Conventional epidurography (CE) is thought to have insufficient usefulness on percutaneous epidural adhesiolysis (PEA). The investigators aimed to evaluate the association between the outcome of PEA and three dimensional-rotational epidurography (3D-RE). The investigators performed 30 PEA in 26 patients, and evaluated their post-PEA image findings. Two independent clinicians categorized and recorded the occurrence of contrast at intra-canal ventral and extra-foraminal regions on CE; and contrast at dorsal canal (DC), ventral canal (VC), dorsal foramen (DF), and ventral foramen (VF) on 3D-RE. Reproducibility was assessed using intra-class correlation coefficients (ICCs). The symptom relief after one month for the patients receiving PEA and the contrast distribution patterns of CE and 3D-RE and were determined.
Detailed description
Patient Selection. This prospective study protocol was approved by the ethics committee, and informed consent was obtained from all subjects. The investigators analyzed the medical and radiographic records included patients who underwent lumbar PEA procedures at a single university hospital. The inclusion criterion was FBSS and SS with unilateral radiculopathy. All patients reported a history of discogenic or radicular symptoms refractory to conservative treatments and epidural steroid injection for a minimum of 6 weeks. Diagnoses were established using magnetic resonance imaging (MRI) and/or computed tomography (CT) performed before PEA. The PEA was standardized to all patients receiving the procedure. Each patient received an epidural injection, and if the symptoms persisted or the relief was insufficient, the patient received PEA >6-week interval between the epidural steroid injection. Positive provocative test during PEA was used to confirm the affected spinal level [11]. All patients underwent CE before and after PEA; and 3D-RE after PEA. Patients with a history of spinal surgery and those with cauda equina syndrome, bleeding diathesis, associated somatic or psychiatric disease, vertebral fractures, pregnancy, and tumors or other underlying systemic diseases that could significantly affect the procedural outcomes were excluded. The patients had bilateral symptoms and did not react to the provocation during PEA were also excluded. All procedures were performed by one of the authors (YCH) using the same procedural protocol.
PEA Procedure. A standard PEA procedure was used to lyse adhesions and achieve nerve blockades in all patients, as previously described [1,2]. A 1-day standardized protocol was followed. The patient was placed on a radiolucent table in the prone position, and the procedure was performed under fluoroscopic guidance. The coccygeal and sacral regions were disinfected with 10% Betadine, and the surgical site was draped in the usual aseptic manner. The sacral hiatus was anesthetized with 1% xylocaine. Then, a 13.6-G Coaxial needle was introduced into the epidural space below the level of S3 with a combined use of US-guidance and fluoroscopy insurance. The US was provided using a scanner (Xario 100; Toshiba, Tokyo, Japan) with a 7~18 MHz linear transducer (PLU-1204BT). A total of 0.5 mL of the contrast agent (Omnipaque, GE Healthcare, Ireland) was instilled to confirm the epidural space. Both anteroposterior, right-oblique, left-oblique, and lateral fluoroscopic views were obtained. The investigators also assessed the development of any adverse reactions. On confirmation of the target for PEA, an angiographic catheter (Cobra 4-Fr; Cordis, USA) and/or coaxial supporting catheter (Chiba 6-Fr; Cook, USA) was gently inserted toward the target site. Once it reached the target site, a second CE was obtained by injecting 3 mL of the contrast agent for the identification of filling defects or cutoff signs surrounding the target area. The investigators choose the target nerve roots for PEA by clinical dermatome involvement and provocation tests during PEA. The catheter tip was positioned at the ventral epidural space of the target site, and in the case of foraminal diseases, was placed at the opening of the foramen [12]. When the tip of the catheter touched the target site or the contrast agent exerted pressure on the lesion, patients were asked to report provoked symptoms [4]. According to the surgical records, they frequently reported pain similar to what they had been suffering. Both mechanical and fluid adhesiolysis were performed. The former was achieved through pushing, pulling, and rotating movements of the catheter, while the latter was achieved by the injection of 0.9% normal saline (10 mL). Following PEA, a third CE and 3D-RE was obtained using 3 mL of the contrast agent. All CE and 3D-RE images were saved in the Digital Imaging and Communications in Medicine format for future analysis, and the CE and 3D-RE after PEA was used for analysis in our study. Finally, a 40 mg triamcinolone acetonide (YungShin, Taichung, Republic of China) was slowly injected.
3D-RE technique. After performing PEA, 3D-RE are obtained on a commercial digital bi-plane angiography system (Allura Xper, Philips). A 240-degree rotation forward and backward of the tube-camera unit around the patient's longitudinal axis within 4 seconds is performed by using an acquisition matrix of 1024 x 1024 pixels. The forth and back rotation results in 120 radiographs. Raw data were automatically sent to a dedicated workstation (Philips Xtra vision workstation), where the rotational projection images are prepared for computed 3D reconstruction. 2D radiographs are used to determine the volume of interest. After correction of gain and distortion, a 3D data set is calculated, resulting in 512 transverse CT-equivalent sections. Depending on the initially chosen volume of interest, the voxel size varies from 0.1 to 0.6 mm. The investigators used a resolution of 0.14-mm voxel size, which resulted in a 3D cuboid of 25 x 19 x 25 cm.
Reconstruction time was 30 seconds. Detailed information regarding technical performance and reconstruction procedure has been reported [13]. Postprocessing techniques provided by the software included real-time 3D volume rendering and multiplanar reformatting. Real-time 3D volume rendering creates a 3D model of the examined object. The software allows emphasizing bony structures or soft tissue by changing intensity, brightness, and opacity of different X-ray structures. Additionally, rotation of the 3D object in all directions is possible, as is a virtual stereoscopic view provided by the software in combination with special glasses. The multiplanar reformatting modus generates virtual sections according to the three main axes and free defined axes. The section planes can be freely chosen, and curved sectioning is also possible.
Conventional epidurography and 3D-RE Contrast Distributions. Post-PEA CE contrast patterns were defined and classified into 2 types according to the system proposed by Park et al. and Gupta et al.[4,6]: Limited intracanal ventral spread (ICV) and extended extraforaminal spread (EF) (Figure 1). The investigators defined the contrast distributions into 4 areas by post-PEA 3D-RE : Dorsal Canal (DC), contrast spread to the dorsal zone of the ipsilateral epidural space not extending to the neural foramen; Ventral Canal (VC), contrast spread to the ventral zone of the ipsilateral epidural space not extending to the neural foramen; Dorsal Foramen (DF), contrast spread to the dorsal zone of the ipsilateral epidural space extending to the neural foramen; Ventral Foramen (VF), contrast spread to the ventral zone of the ipsilateral epidural space extending to the neural foramen (Figure 2). The CE and 3D-RE images were analyzed and recorded by a musculoskeletal radiologist (Y.C.H.) and a surgeon (C.T.T.) who blinded to the results of the clinical data. The investigators made a consensus if there was discrepancy between the analyses of these images.
Data collection. All patients were clinically evaluated before and 1 month after PEA by a nurse specialized in pain management and blinded to the treatment details. The intensity of leg and back pain prior to PEA was assessed using a subjective visual analog scale (VAS) calibrated from 0 to 10 (0 = no pain and 10 = the worst pain imaginable). The patients' symptoms relief was rated using a Likert scale: 5 = greatly relief; 4 = some residual symptoms and symptoms relief > 50%; 3 = some residual symptoms and symptoms relief = 50%; 2 = residual symptoms and symptoms relief < 50%; 1 = no symptoms relief. For the comparison of clinical outcomes according to the symptoms relief, patients with grade 3, grade 4, and grade 5 were assigned to a group exhibiting >= 50% symptoms relief, while patients with grade 1 and grade 2 were assigned to a group exhibiting < 50% symptoms relief. Regarding the radiation exposure of PEA, simulations were performed with patient-specific input parameters (weight and length) and the actual 3D-RE system settings for each frame, including the automatic modulation of beam energy and dose level, and collimation. Effective dose (ED), which has been generally accepted single number index reflecting patient radiation risk, was subsequently calculated using the latest ICRP 103 weighing factors, published in 2007 [14].
StatisticalAnalysis. Age, the duration of discomfort prior to PEA, and VAS scores are expressed as means ±standard deviations. Demographic data within the two groups of greater symptoms relief and less were compared by using the chi-square test or the Fisher's exact test or unpaired t-test. Inter-reader agreement was evaluated using the intra-class correlation coefficients (ICCs), calculated according to Landis and Koch[15], for the contrast distribution of CE and 3D-RE. Simple linear regression analysis was used to determine the prediction of the outcome of PEA by the contrast distribution of CE and 3D-RE. All statistical analyses were performed using the Statistical Package for the Social Sciences software (SPSS Inc., Chicago, Illinois, USA). A P value of <0.05 was considered statistically significant.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Three dimensional-rotational epidurography (3D-RE) | – | Device: Cone beam computed tomography3D-RE is obtained on a commercial digital bi-plane angiography system. Reconstruction time was 30 seconds. Detailed information regarding technical performance and reconstruction procedure has been reported. Postprocessing techniques provided by the software included real-time 3D volume rendering and multiplanar reformatting. Real-time 3D volume rendering creates a 3D model of the examined object. The software allows emphasizing bony structures or soft tissue by changing intensity, brightness, and opacity of different X-ray structures. Additionally, rotation of the 3D object in all directions is possible, as is a virtual stereoscopic view provided by the software in combination with special glasses. The multiplanar reformatting modus generates virtual sections according to the three main axes and free defined axes. The section planes can be freely chosen, and curved sectioning is also possible. |
Who may qualify
- Ages
- Up to 20 years
- Sex
- All
- Age groups
- Child, Adult
- Study population
- Patients who had FBSS or SS with unilateral radiculopathy underwent PEA.
Key inclusion criteria (6 listed)
- FBSS or SS with unilateral radiculopathy.
- History of discogenic or radicular symptoms refractory to conservative treatments and epidural steroid injection for a minimum of 6 weeks.
- The PEA was standardized to all patients receiving the procedure.
- Each patient received an epidural injection, and if the symptoms persisted or the relief was insufficient, the patient received PEA >6-week interval between the epidural steroid injection.
- Positive provocative test during PEA was used to confirm the affected spinal level.
Key exclusion criteria (9 listed)
- History of spinal surgery and those with cauda equina syndrome
- Bleeding diathesis
- Associated somatic or psychiatric disease
- Vertebral fractures
- Pregnancy
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Cone beam computed tomographyThe contrast agent (Omnipaque, GE Healthcare, Ireland) was instilled to confirm the epidural space. With use of a calibrated angiographic C-arm system and a postprocessing workstation, we acquired volume data sets from two dimensional digital projection images obtained to reconstruct the 3D-RE during a C-arm rotation around the patient axis. | Device | Three dimensional-rotational epidurography (3D-RE) |
Primary outcome
Symptoms change after PEA
Time frame: 1 month
For the comparison of clinical outcomes according to the symptoms change, the participants' symptoms change was rated using a Likert scale to defined two groups by exhibiting >= 50% symptoms change and < 50% symptoms change.
Reproducibility of CE and 3D-RE
Time frame: 1 month
Inter-reader agreement was evaluated using the intra-class correlation coefficients (ICCs), calculated according to Landis and Koch, for the contrast distribution of CE and 3D-RE.
Usefulness of 3D-RE for predicting the outcome of PEA
Time frame: 3 months
Simple linear regression analysis was used to determine the prediction of the outcome of PEA by the contrast distribution of CE and 3D-RE.
1 secondary outcome
Radiation exposure of PEA
Time frame: 1 month
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Jan 2020.
- Background: PubMed 24658484Manchikanti L, Helm Ii S, Pampati V, Racz GB. Percutaneous adhesiolysis procedures in the medicare population: analysis of utilization and growth patterns from 2000 to 2011. Pain Physician. 2014 Mar-Apr;17(2):E129-39.
- Background: PubMed 23703406Gerdesmeyer L, Wagenpfeil S, Birkenmaier C, Veihelmann A, Hauschild M, Wagner K, Muderis MA, Gollwitzer H, Diehl P, Toepfer A. Percutaneous epidural lysis of adhesions in chronic lumbar radicular pain: a randomized, double-blind, placebo-controlled trial. Pain Physician. 2013 May-Jun;16(3):185-96.
- Background: PubMed 18503627Racz GB, Heavner JE, Trescot A. Percutaneous lysis of epidural adhesions--evidence for safety and efficacy. Pain Pract. 2008 Jul-Aug;8(4):277-86. doi: 10.1111/j.1533-2500.2008.00203.x. Epub 2008 May 23.
- Background: PubMed 29808106Park SH, Ji GY, Cho PG, Shin DA, Yoon YS, Kim KN, Oh CH. Clinical Significance of Epidurography Contrast Patterns after Adhesiolysis during Lumbar Percutaneous Epidural Neuroplasty. Pain Res Manag. 2018 Apr 1;2018:6268045. doi: 10.1155/2018/6268045. eCollection 2018.
- Background: PubMed 24750546Kim JH, Jung HJ, Nahm FS, Lee PB. Does improvement in epidurography following percutaneous epidural neuroplasty correspond to patient outcome? Pain Pract. 2015 Jun;15(5):407-13. doi: 10.1111/papr.12197. Epub 2014 Apr 21.
- Background: PubMed 25317285Gupta R, Singh S, Kaur S, Singh K, Aujla K. Correlation between Epidurographic Contrast Flow Patterns and Clinical Effectiveness in Chronic Lumbar Discogenic Radicular Pain Treated with Epidural Steroid Injections Via Different Approaches. Korean J Pain. 2014 Oct;27(4):353-9. doi: 10.3344/kjp.2014.27.4.353. Epub 2014 Oct 1.
- Background: PubMed 27651508Hong Park C, Ho Lee S. Epidurographic Findings Following Percutaneous Epidural Adhesiolysis Failed to Correlate with Level of Pain Reduction in Patients with Lumbar Spinal Stenosis. Pain Med. 2017 May 1;18(5):842-845. doi: 10.1093/pm/pnw244.
- Background: PubMed 22514786Shin JW. Is epidurogram a reliable tool for the diagnosis of epidural adhesion? Korean J Pain. 2012 Apr;25(2):133-4. doi: 10.3344/kjp.2012.25.2.133. Epub 2012 Apr 4. No abstract available.
- Background: PubMed 12917114Kufeld M, Claus B, Campi A, Lanksch WR, Benndorf G. Three-dimensional rotational myelography. AJNR Am J Neuroradiol. 2003 Aug;24(7):1290-3.
- Background: PubMed 11719688El-Sheik M, Heverhagen JT, Alfke H, Froelich JJ, Hornegger J, Brunner T, Klose KJ, Wagner HJ. Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: initial results. Radiology. 2001 Dec;221(3):843-9. doi: 10.1148/radiol.2213010606.
- Background: PubMed 16000173Manchikanti L, Boswell MV, Rivera JJ, Pampati VS, Damron KS, McManus CD, Brandon DE, Wilson SR. [ISRCTN 16558617] A randomized, controlled trial of spinal endoscopic adhesiolysis in chronic refractory low back and lower extremity pain. BMC Anesthesiol. 2005 Jul 6;5:10. doi: 10.1186/1471-2253-5-10.
- Background: PubMed 28246488Moon SH, Lee JI, Cho HS, Shin JW, Koh WU. Factors for Predicting Favorable Outcome of Percutaneous Epidural Adhesiolysis for Lumbar Disc Herniation. Pain Res Manag. 2017;2017:1494538. doi: 10.1155/2017/1494538. Epub 2017 Jan 26.
- Individual participant dataSharing planned: Undecided
Related trials for Failed Back Surgery Syndrome
RecruitingObservational study
Open and Closed Loop DTM SCS in Patients With PSPS Type 2: ENDLESS Study
Persistent Spinal Pain Syndrome Type 2, Failed Back Surgery Syndrome
RecruitingPhase 4
Success Rates and Safety of Steroid Injections in Managing Spinal and Sacro-Iliac Pain (CORTisone Injection Spine Study)
Back Pain Lower Back, Neck Pain
Not yet recruitingObservational study
SPINE-RISK VE: Multimodal Predictive Model for Failed Back Surgery Syndrome in Venezuelan Surgical Patients
Persistent Spinal Pain Syndrome Type 2 (PSPS-T) Lower Spine, Chronic Low Back Pain
Active, not recruiting
Restoring Segmental Lumbar Lordosis After Failed Previous Fusion at the Same Level
Failed Back Surgery Syndrome, Degeneration Lumbar Spine
Recruiting
Improvement of Gait by Spinal Stimulation in Patients With Postoperative Chronic Lumbosciatalgia: Pilot Study (GaitStim)
Failed Back Surgery Syndrome
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Yi-Chih Hsu, M.D. study director
Department of Radiology Tri-Service General Hospital National Defense Medical Center
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Failed Back Surgery Syndrome and Spinal Stenosis, run by Tri-Service General Hospital (TSGH) at 1 site in Taiwan.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 6 Jan 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Taiwan. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Symptoms change after PEA (time frame: 1 month). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04216992, which also lists 14 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Jan 2020.