AzTrials
AzTrials

Supraglottic Airway EfficiencyNCT04196582

LMA® Gastro Airway Versus Gastro-Laryngeal Tube in Endoscopic Retrograde Cholangiopancreatography

A study testing Comparison of LMA Gastro Airway® and Gastro-Laryngeal Tube in patients who will undergo biliopancreatic procedures. in people with Supraglottic Airway Efficiency and Airway Complication of Anesthesia, run by Bezmialem Vakif University at 1 site in Turkey (Türkiye).

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Comparison of second generation supraglottic airway devices about anesthesiologist, endoscopist and patient, which used for gastrointestinal procedures. The investigators believe that the endoscope will be easier to reach by the part of GLT extending to the esophagus, but the structural stiffness of this part may… Read more about this study

Who is it for?
Ages 18 to 70 years
What is being tested?
Comparison of LMA Gastro Airway® and Gastro-Laryngeal Tube in patients who will undergo biliopancreatic procedures.
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
100 participants
Where
1 siteTurkey (Türkiye)
Study dates
20 Nov 2019to 10 Jul 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 70 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • ASA Physical Status 1-2
  • Elective Procedures
  • Weight 50-100 Kg

Who cannot join

  • Laryngeal mask airway contraindications.
  • Anesthesic drug allergies
  • Height <155 cm
  • Body Mass index > 35 kg/m2
  • Alcohol or narcotic drug usage
  • Restrictive or obstructive pulmonary diseases
Show all 14Show fewer
  • Hepatic cardiac or renal failure
  • Psychotic problems
  • Neurologic or cognitive deficiencies.
  • Pregnancy
  • Difficult airway or facial deformities
  • Previous cervical surgery or cervical radiotherapy
  • Previous esophagus surgery
  • High risk of pulmonary aspiration

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Bezmialem Vakif University

    Istanbul

Other trials in Turkey (Türkiye)

About this study

Official title: Comparison of LMA® Gastro Airway and Gastro-Laryngeal Tube in Endoscopic Retrograde Cholangiopancreatography: a Prospective Randomized Observational Trial

Comparison of second generation supraglottic airway devices about anesthesiologist, endoscopist and patient, which used for gastrointestinal procedures. The investigators believe that the endoscope will be easier to reach by the part of GLT extending to the esophagus, but the structural stiffness of this part may damage the esophageal mucosa. On the other hand, since the endoscopic canal of the LMA® Gastro ends at the upper end of the esophagus, it may be more difficult to orient the endoscope to the esophagus, but it may be superior in terms of ventilation efficiency. Therefore these two device worth for comparing.

Read the detailed description

Supraglottic airway (SGA) devices are produced for avoiding endotracheal intubation for anesthesic interventions. Second generation SGA's like GLT and LMA® Gastro airway are using for endoscopic biliopancreatic procedures. Both of them have an airway canal and endoscopic canal. Although they can use for same reason, their designs are different. So, their airway securities, endoscopic manipulations and complications, would be different.

This study planned as single blind. American Society of Anesthesiologists (ASA) Physical status 1-2 100 patients which will be take endoscopic retrograde cholangiopancreatography (ERCP) included. The study starts after randomization and ends after discharge from the recovery room. All patients will be monitorised for hemodynamic parameters. Depth of anesthesia will be provided by bispectral index (BIS) monitoring. After anesthesia induction SGA will placed by an experienced anesthesiologist. Bilateral chest movements and auscultation, capnogram graphy and oropharyngeal leak pressure test will be used for confirmation of placement. After procedure endoscopist will take pictures of esophagus and hypopharynx. After extubation and sufficient consciousness and breathing of patient, patients will be transferred to post-anaesthesia care unit (PACU). Vital parameters will continue to monitoring in PACU. Patients will be discharge as usual with an Aldrete score ≥ 9.

Data will be collected during the procedure and in recovery room. Data will be stored in electronic database without mention to patient's name.

Being tested
Comparison of LMA Gastro Airway® and Gastro-Laryngeal Tube in patients who will undergo biliopancreatic procedures.
Keywords
LMA gastro airway, Gastro-laryngeal tube, ERCP, airway complications

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Comparison of LMA Gastro Airway® and Gastro-Laryngeal Tube in patients who will undergo biliopancreatic procedures.Device

    comparing efficiency and complications of second generation airway devices which can use for gastrointestinally procedures

Study groups in NCT04196582
Study groupRoleWhat they receive
Gastro-laryngeal tube Group (Group G)Active comparatorPatients wear Gastro-laryngeal tube after receiving general anesthesia for biliopancreatic procedures
Receives: Device: Comparison of LMA Gastro Airway® and Gastro-Laryngeal Tube in patients who will undergo biliopancreatic procedures.
LMA Gastro Airway Group (Group L)Active comparatorPatients wear LMA Gastro Airway® after receiving general anesthesia for biliopancreatic procedures
Receives: Device: Comparison of LMA Gastro Airway® and Gastro-Laryngeal Tube in patients who will undergo biliopancreatic procedures.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Oropharyngeal leak pressure

    Oropharyngeal leak pressure is the airway pressure at which the circuit pressure stabilizes by closing the expiratory valve of the circle system at a constant gas flow of 3 L / min.

    Measured: Intra-operative; after device insertion

  2. Endoscopist satisfaction analysis: score

    Endoscopist will score from 0 (worst) to 10 (best)

    Measured: Immediately after the procedure

  3. Leakage rate percentages

    The leakage rate percentage is the calculation of the difference between the adjusted tidal volume and the exhaled tidal volume and then proportioning to the adjusted tidal volume.

    Measured: Intra-operative; after device insertion at first minute

Secondary outcomes (3)
  1. Hypopharyngeal/Esophageal Mucosal status

    Number of patients with hyperemia, laceration (while extubating patient, endoscopist will take pictures of esophagus for if there is any mucosal damage). Esophageal and hypopharyngeal mucosal damage was determined in 5 grades by a visual mucosal damage scoring system [grade 1- normal mucosa, grade 2- mild hyperemia, grade 3-severe hyperemia, grade 4-bloody gross hyperemia, grade 5- laceration].

    Measured: Within the first minute after the procedure is completed, while the duodenoscope is being removed while it passes through the esophagus and hypopharynx

  2. Blood staining on the device

    Whether there is blood on the supraglottic airway device or not

    Measured: Immediately after removing the supraglottic airway device

  3. Presence of sore throat

    Sore throat if present, was classified as mild, moderate or severe.

    Measured: One hour after extubation

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Dec 2019
  2. Study start20 Nov 2019
  3. Primary completion20 Jun 2020
  4. Study completion10 Jul 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
100 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04196582
Sponsor's protocol ID
Bezmialem Vakif University
Status last verified
Nov 2020
First submitted
25 Nov 2019
Last updated
3 Nov 2020
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Comparison of LMA Gastro Airway® and Gastro-Laryngeal Tube in patients who will undergo biliopancreatic procedures. in people with Supraglottic Airway Efficiency and Airway Complication of Anesthesia, run by Bezmialem Vakif University at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 14 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 3 Nov 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Oropharyngeal leak pressure (time frame: Intra-operative; after device insertion). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Nov 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in