Smart Watch iECG for the Detection of Cardiac Arrhythmias
An observational study of Arrhythmias, Cardiac and Atrial Fibrillation, run by Helios Health Institute GmbH at 1 site in Germany.
Trial summary
This study aims to assess the feasibility and reliability of smart watch iECG provided by the Apple Watch/Apple iPhone for the detection of different cardiac arrhythmias. In this study, results from a 12-lead ECG will be set as the gold standard for the arrhythmia diagnosis, and results from the smart watch iECG… Read more about this study
- Who is it for?
- Ages 22 years and older
- Conditions the study is for
- Arrhythmias, Cardiac, Atrial Fibrillation
- What is being tested?
- iECG recording
- Type of treatment
- Medical device
- How many people
- 500 participants
- Where
- 1 siteGermany
- Study dates
- 30 Sep 2019to 30 Jul 2021
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 22 years and older
- All sexes
- Adult, Older adult
Study population: All individuals who had been admitted to the Department of Electrophysiology, Leipzig Heart Center
Who may be able to join
- Patients aged≥22 years at the time of eligibility screening will be included.
- Patients with known cardiac arrhythmias; i.e. AF before and after cardioversion, hemodynamically stable Bradycardias, SVT and VT during EP procedures and implants can also be included
Who cannot join
- Pregnancy
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Feasibility and Reliability of Smart Watch iECG for the Detection of Cardiac Arrhythmias (The Leipzig Apple Heart Rhythm Study)
This study aims to assess the feasibility and reliability of smart watch iECG provided by the Apple Watch/Apple iPhone for the detection of different cardiac arrhythmias. In this study, results from a 12-lead ECG will be set as the gold standard for the arrhythmia diagnosis, and results from the smart watch iECG (Apple watch/Apple iPhone application and Cardiologist's interpretations) as the index tests. The iECG tracings will be recorded simultaneously, starting and ending at the same time as the standard 12-lead ECG, using the built-in sensors of a smart watch (Apple Watch Series 4) with the ECG application.
Read the detailed description
This diagnostic accuracy study is an investigator-initiated trial to evaluate the value of a smart watch-based iECG for detection of cardiac arrhythmias.
iECG tracings will be recorded simultaneously, starting and ending at the same time as the standard 12-lead ECG, using the built-in sensors of a smart watch (Apple Watch Series 4) with the market version of the ECG application (Apple Inc., California). Participants will be advised to lie down in a supine position and breathe spontaneously. All recording will be done by trained study personnel.
All iECG and 12-lead ECG recordings will be presented in PDF format as our references. Saved formats will be transferred to our Telemonitoring Center for further analysis and processing.
Results from a 12-lead ECG will be considered as the gold standard for the measurement of heart rhythms and the arrhythmia diagnosis. All 12-lead ECGs recordings will be analyzed by 2 blinded cardiologists and will be categorized as "Sinus rhythm", "High or low heart rate", "Atrial fibrillation", or "Inconclusive". Besides, cardiologists will report ECG wave's characteristics as well as any other possible diagnosis including "Superior ventricular tachycardia", "Ventricular tachycardia", "Atrial flutter", and "other types: other possible arrhythmias". In the case of uncertainties, a third cardiologist will be consulted, blinded for initial diagnoses.
The iECG recordings (test index) will be interpreted and reported in two different ways:
- By using HealthKit Framework (Apple Watch and Apple iPhone applications): After a successful iECG recording with the Apple watch, iECGs will be transmitted by the ECG application to the iPhone. The Health App (Apple Inc., California) will receive, process and store the iECGs on the iPhone and will present one of the following results on the iPhone screen automatically: "Sinus rhythm", "High or low heart rate", "Atrial fibrillation", or "Inconclusive". Besides, the mean heart rate will be recorded, which will be automatically calculated by the Health App.
- By cardiologist: All iECGs will be analyzed by 2 blinded cardiologists. They will report their findings in the following categorize: "Sinus rhythm", "High or low heart rate", "Atrial fibrillation", or "Inconclusive". Besides, they will report ECG wave's characteristics as well as any other possible diagnosis including "Superior ventricular tachycardia", "Ventricular tachycardia", "Atrial flutter", and "other types: other possible arrhythmias". In the case of uncertainties, a third cardiologist will be consulted, blinded for initial diagnoses.
ECG wave's characteristics: The following variables will be measured as the iECG and 12-lead ECG waves' characteristics. Three randomly chosen heartbeats will be considered to measure each wave or interval, and the mean of these 3 measurements will be used for statistical analysis.
- Conditions
- Arrhythmias, Cardiac, Atrial Fibrillation
- Being tested
- iECG recording
- Keywords
- Arrhythmias, Cardiac, Cardiovascular App, Rhythm monitoring
- Medical subject headings
- Arrhythmias, Cardiac, Atrial Fibrillation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
iECG recordingDevice
iECG tracings will be recorded simultaneously, starting and ending at the same time as the standard 12-lead ECG, using the built-in sensors of a smart watch (Apple Watch Series 4) with the ECG application
| Study group | Role | What they receive |
|---|---|---|
| Patients suspected with Cardiac Arrhythmia | iECG + 12-lead ECG recording in patients suspected with any type of cardiac arrhythmias at the time of recruitment Receives: Device: iECG recording |
What is being measured
The primary outcome is the main question the study is designed to answer.
Level of agreement between the cardiologist's interpretations of the 12-lead ECG and the ECG App interpretation results
Measured: Baseline
Level of agreement between the cardiologist's interpretations of the 12-lead ECG and iECG
Measured: Baseline
Level of agreement between the cardiologist's interpretations of the iECG and the ECG App interpretation results
Measured: Baseline
Secondary outcomes (4)
Proportion of participants that remain in arrhythmia diagnosis, from the positive diagnosis from the iECG to the performed 12-lead ECG
Measured: Baseline
Proportion of interpretable and non-interpretable iECGs
Measured: Baseline
Sensitivity and specificity of screening tests for cardiac arrhythmias identification using: cardiologists interpretation of iECG (index test) and 12-lead ECGs (reference test)
Measured: Baseline
Sensitivity and specificity of screening tests for cardiac arrhythmias identification using: ECG App interpretation results (index test) and 12-lead ECGs (reference test)
Measured: Baseline
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted17 Sep 2019
- Study start30 Sep 2019
- Primary completion30 Jul 2021
- Study completion30 Jul 2021
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Arrhythmias, CardiacStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 500 participants (actual)
Sponsor and investigators
- Lead sponsor
- Helios Health Institute GmbH
- Sponsor type
- University, hospital or other
- Collaborators
- Heart Center Leipzig - University Hospital
- Responsible party
- Sponsor
- Investigators
- Andreas Bollmann, MD, PhD, Study chair, Heart Center Leipzig at University of Leipzig, Leipzig Heart Institute, Germany
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04092985
- Sponsor's protocol ID
- 2019-0157
- Status last verified
- Oct 2024
- First submitted
- 16 Sep 2019
- Last updated
- 8 Oct 2024
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Publications
Behzadi A, Sepehri Shamloo A, Mouratis K, Hindricks G, Arya A, Bollmann A. Feasibility and Reliability of SmartWatch to Obtain 3-Lead Electrocardiogram Recordings. Sensors (Basel). 2020 Sep 7;20(18):5074. doi: 10.3390/s20185074.
PubMed 32906661
Study at a glance
From the registry record, last updated by the sponsor on 8 Oct 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Feasibility and Reliability of Smart Watch iECG for the Detection of Cardiac Arrhythmias (The Leipzig Apple Heart Rhythm Study)
- ClinicalTrials.gov ID
- NCT04092985
- Acronym / sponsor ID
- 2019-0157
- Conditions
- Arrhythmias, Cardiac, Atrial Fibrillation
- Keywords
- Arrhythmias, Cardiac, Cardiovascular App, Rhythm monitoring
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 500 participants (actual)
- Lead sponsor
- Helios Health Institute GmbHUniversity, hospital or other
- Collaborators
- Heart Center Leipzig - University Hospital
- Study start
- 30 Sep 2019 (actual)
- Primary completion
- 30 Jul 2021 (actual)
- Study completion
- 30 Jul 2021 (actual)
- First posted
- 17 Sep 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study aims to assess the feasibility and reliability of smart watch iECG provided by the Apple Watch/Apple iPhone for the detection of different cardiac arrhythmias. In this study, results from a 12-lead ECG will be set as the gold standard for the arrhythmia diagnosis, and results from the smart watch iECG (Apple watch/Apple iPhone application and Cardiologist's interpretations) as the index tests. The iECG tracings will be recorded simultaneously, starting and ending at the same time as the standard 12-lead ECG, using the built-in sensors of a smart watch (Apple Watch Series 4) with the ECG application.
Detailed description
This diagnostic accuracy study is an investigator-initiated trial to evaluate the value of a smart watch-based iECG for detection of cardiac arrhythmias.
iECG tracings will be recorded simultaneously, starting and ending at the same time as the standard 12-lead ECG, using the built-in sensors of a smart watch (Apple Watch Series 4) with the market version of the ECG application (Apple Inc., California). Participants will be advised to lie down in a supine position and breathe spontaneously. All recording will be done by trained study personnel.
All iECG and 12-lead ECG recordings will be presented in PDF format as our references. Saved formats will be transferred to our Telemonitoring Center for further analysis and processing.
Results from a 12-lead ECG will be considered as the gold standard for the measurement of heart rhythms and the arrhythmia diagnosis. All 12-lead ECGs recordings will be analyzed by 2 blinded cardiologists and will be categorized as "Sinus rhythm", "High or low heart rate", "Atrial fibrillation", or "Inconclusive". Besides, cardiologists will report ECG wave's characteristics as well as any other possible diagnosis including "Superior ventricular tachycardia", "Ventricular tachycardia", "Atrial flutter", and "other types: other possible arrhythmias". In the case of uncertainties, a third cardiologist will be consulted, blinded for initial diagnoses.
The iECG recordings (test index) will be interpreted and reported in two different ways:
- By using HealthKit Framework (Apple Watch and Apple iPhone applications): After a successful iECG recording with the Apple watch, iECGs will be transmitted by the ECG application to the iPhone. The Health App (Apple Inc., California) will receive, process and store the iECGs on the iPhone and will present one of the following results on the iPhone screen automatically: "Sinus rhythm", "High or low heart rate", "Atrial fibrillation", or "Inconclusive". Besides, the mean heart rate will be recorded, which will be automatically calculated by the Health App.
- By cardiologist: All iECGs will be analyzed by 2 blinded cardiologists. They will report their findings in the following categorize: "Sinus rhythm", "High or low heart rate", "Atrial fibrillation", or "Inconclusive". Besides, they will report ECG wave's characteristics as well as any other possible diagnosis including "Superior ventricular tachycardia", "Ventricular tachycardia", "Atrial flutter", and "other types: other possible arrhythmias". In the case of uncertainties, a third cardiologist will be consulted, blinded for initial diagnoses.
ECG wave's characteristics: The following variables will be measured as the iECG and 12-lead ECG waves' characteristics. Three randomly chosen heartbeats will be considered to measure each wave or interval, and the mean of these 3 measurements will be used for statistical analysis.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Patients suspected with Cardiac Arrhythmia | – | Device: iECG recordingiECG + 12-lead ECG recording in patients suspected with any type of cardiac arrhythmias at the time of recruitment |
Who may qualify
- Ages
- 22 years and older
- Sex
- All
- Age groups
- Adult, Older adult
- Study population
- All individuals who had been admitted to the Department of Electrophysiology, Leipzig Heart Center
Key inclusion criteria (2 listed)
- Patients aged≥22 years at the time of eligibility screening will be included.
- Patients with known cardiac arrhythmias; i.e. AF before and after cardioversion, hemodynamically stable Bradycardias, SVT and VT during EP procedures and implants can also be included
Key exclusion criteria (1 listed)
- Pregnancy
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| iECG recordingiECG tracings will be recorded simultaneously, starting and ending at the same time as the standard 12-lead ECG, using the built-in sensors of a smart watch (Apple Watch Series 4) with the ECG application | Device | Patients suspected with Cardiac Arrhythmia |
Primary outcome
Level of agreement between the cardiologist's interpretations of the 12-lead ECG and the ECG App interpretation results
Time frame: Baseline
Level of agreement between the cardiologist's interpretations of the 12-lead ECG and iECG
Time frame: Baseline
Level of agreement between the cardiologist's interpretations of the iECG and the ECG App interpretation results
Time frame: Baseline
4 secondary outcomes
Proportion of participants that remain in arrhythmia diagnosis, from the positive diagnosis from the iECG to the performed 12-lead ECG
Time frame: Baseline
Proportion of interpretable and non-interpretable iECGs
Time frame: Baseline
Sensitivity and specificity of screening tests for cardiac arrhythmias identification using: cardiologists interpretation of iECG (index test) and 12-lead ECGs (reference test)
Time frame: Baseline
Sensitivity and specificity of screening tests for cardiac arrhythmias identification using: ECG App interpretation results (index test) and 12-lead ECGs (reference test)
Time frame: Baseline
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 8 Oct 2024.
- Results publication: PubMed 32906661Behzadi A, Sepehri Shamloo A, Mouratis K, Hindricks G, Arya A, Bollmann A. Feasibility and Reliability of SmartWatch to Obtain 3-Lead Electrocardiogram Recordings. Sensors (Basel). 2020 Sep 7;20(18):5074. doi: 10.3390/s20185074.
- Individual participant dataSharing planned: No
Related trials for Arrhythmias, Cardiac
RecruitingObservational study
AI-powered ECG Analysis Using Willem™ Software in High-risk Cardiac Patients (WILLEM)
Cardiomyopathies, Cardiac Arrest
Not yet recruiting
nCPAP-NAVA-Backup Versus Standard nCPAP for Severe Apnea in Preterm Infants ≤28 Weeks
Apnea of Prematurity
Active, not recruiting
Horizon 360 Protocol for the Treatment of Paroxysmal Atrial Fibrillation With the Sphere-360™ Catheter and Affera™ Mapping and Ablation System (Horizon 360)
Paroxysmal AF
Not yet recruiting
Smartphone Camera Measurement of Breathing-Related Heart Rate Variability Compared With ECG in Healthy Adults
Respiratory Sinus Arrhythmia, Heart Rate Variability
Active, not recruitingObservational study
Concomitant Left Atrial Appendage Closure and Pulsed Field Ablation-Asia
Concomitant Procedures, Atrial Fibrillation
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Andreas Bollmann, MD, PhD study chair
Heart Center Leipzig at University of Leipzig, Leipzig Heart Institute, Germany
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Arrhythmias, Cardiac and Atrial Fibrillation, run by Helios Health Institute GmbH at 1 site in Germany.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 8 Oct 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Level of agreement between the cardiologist's interpretations of the 12-lead ECG and the ECG App interpretation results (time frame: Baseline). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04092985, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Oct 2024.