AzTrials
AzTrials

Low Blood PressureNCT04082819

MediBeat - HeartBeat Observation Trial

A study testing Contec CMS50EW and Sphygmomanometer in people with Low Blood Pressure and Blood Pressure, run by SE Health at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The goal of the study was to compare the current gold standard blood pressure instrument (a mercury-filled sphygmomanometer with cuff and stethoscope) with the new experimental algorithm developed by HeartBeat Technologies Ltd. Read more about this study

Who is it for?
Ages 25 years and olderHealthy volunteers can take part
What is being tested?
Contec CMS50EW and Sphygmomanometer
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
94 participants
Where
1 siteCanada
Study dates
4 Oct 2019to 17 Dec 2019
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 25 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • adult over 25 years of age

Who cannot join

  • those who have heart arrhythmias,
  • atrial fibrillations or atrial flutters,
  • an inaudible Korotkoff sound,
  • wounds of the upper arms/wrists, missing fingers, and/or
  • an arm circumference of more than 55 cm will be excluded

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • SE Health

    Markham, Ontario, L3R 6H3

Other trials in Canada

About this study

Official title: Determining the Accuracy of the HeartBeat Algorithm for Calculating Blood Pressure

The goal of the study was to compare the current gold standard blood pressure instrument (a mercury-filled sphygmomanometer with cuff and stethoscope) with the new experimental algorithm developed by HeartBeat Technologies Ltd. To that end, participants were recruited from Markham, Ontario and participated in a series of alternating blood pressure measurements over a period of 45 minutes. Comparisons were made between manual measurements and device measurements to determine the quality of the device readings. Measurements were taken by trained nurses and staff were consistent across the study duration.

Read the detailed description

The gold standard instrument for blood pressure measurement is a mercury-filled sphygmomanometer with cuff and stethoscope (Canadian Agency for Drugs and Technologies in Health; Canadian Electronic Library, 2012). However, such a device is not the most convenient for client self-monitoring or virtual (remote) care. Thus, there is a desire for an accurate, reliable alternative for the traditional mercury-containing sphygmomanometer.

HeartBeat Technologies Ltd. ("Heartbeat") has developed a novel approach to measuring blood pressure after an initial blood pressure reading using the conventional measurement method, supplemented by specific characteristics of a person (age, gender, height, weight, and heart rate), has established a "baseline measurement" for the person. The "novel approach" uses a finger pulse oximeter, the Contec CMS50EW device (Figure 1) (manufactured by Contec Medical Systems Co., Ltd., Shanghai, People's Republic of China). The finger pulse oximeter detects the changes in blood volume directly below the person's skin and indirectly measures oxygen saturation in the blood. The measurement is in the form of a photoplethysmogram (PPG) which is captured by the Contec oximeter and then, by Bluetooth technology, transmitted to a smartphone or tablet. A HeartBeat application, called MediBeat, on the smartphone or tablet then transmits the PPG to a server where a proprietary algorithm analyzes the baseline measurement for the person and the PPG to calculate the person's current blood pressure.

Heartbeat's intent is that the current blood pressure reading would then be made available to both the client and the health provider through separate web-based interfaces. Providers would be able to log onto the HeartBeat web-based application from anywhere to review and monitor the blood pressure of multiple clients, while clients can log onto the application to track their own measurements.

Being tested
Contec CMS50EW, Sphygmomanometer
Medical subject headings
Hypotension, Hypertension

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Contec CMS50EWDevice

    Participants' blood pressure will be measured 3 times with the wearable finger pulse oximeter at their study visit.

  • SphygmomanometerDevice

    Participants' blood pressure will be measured 4 times manually with a blood pressure cuff at their study visit.

Study groups in NCT04082819
Study groupRoleWhat they receive
Low Blood PressureOtherLow blood pressure (systolic: 0-129, diastolic: 0-79)
Receives: Device: Contec CMS50EW; Device: Sphygmomanometer
Medium Blood PressureOtherMedium blood pressure (systolic: 130-160, diastolic: 80-100)
Receives: Device: Contec CMS50EW; Device: Sphygmomanometer
High Blood PressureOtherHigh blood pressure (systolic: 161 or higher, diastolic: 101 or higher)
Receives: Device: Contec CMS50EW; Device: Sphygmomanometer

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Difference Between Systolic Manual Sphygmomanometer and Finger Pulse Oximeter Readings

    Each device reading was compared to the manual blood pressure reading taken before (R1) and after it (R2). The degree of alignment for systolic blood pressure was calculated by taking the difference between the two scores (manual and device). The reading with the best alignment was used.

    Measured: 45 - 60 minutes

  2. Difference Between Diastolic Manual and Device Blood Pressure Readings

    Each device reading was compared to the manual reading before (R1) and after (R2) it, to calculate the degree of alignment. The difference of the device and R1, and the device and R2 were taken. The smaller number was used for results reporting.

    Measured: 45-60 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Sep 2019
  2. Study start4 Oct 2019
  3. Primary completion22 Nov 2019
  4. Study completion17 Dec 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Non-randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Investigator, Outcomes assessor
Enrolment
94 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04082819
Sponsor's protocol ID
MCD307-007-1920
Status last verified
Mar 2020
First submitted
4 Sep 2019
Last updated
1 Apr 2020
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Holyoke P, Yogaratnam K, Kalles E. Web-Based Smartphone Algorithm for Calculating Blood Pressure From Photoplethysmography Remotely in a General Adult Population: Validation Study. J Med Internet Res. 2021 Apr 23;23(4):e19187. doi: 10.2196/19187.

    PubMed 33890856

Questions about this trial

What is this clinical trial studying?

A study testing Contec CMS50EW and Sphygmomanometer in people with Low Blood Pressure and Blood Pressure, run by SE Health at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 1 Apr 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 1 Apr 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Difference Between Systolic Manual Sphygmomanometer and Finger Pulse Oximeter Readings (time frame: 45 - 60 minutes). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04082819, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Apr 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in