Tachycardia; Paroxysmal, SupraventricularCOBRA-PATHNCT04078685

Contact-Force-Sensing-Based Radiofrequency Catheter Ablation in Paroxysmal Supraventricular Tachycardias

A study testing Standard catheter ablation and Contact Force-sensing-based catheter ablation in people with Tachycardia; Paroxysmal, Supraventricular and Tachycardia, Supraventricular, run by Erasmus Medical Center at 1 site in Netherlands.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The aim of this single-center prospective randomized controlled trial is to assess the superiority of contact-force-(CF)-sensing-based approach compared to conventional (non-CF-sensing) approach in the catheter ablation of PSVTs, and to investigate the safety of open-irrigated, contact-force-sensing ablation catheters… Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Standard catheter ablation and Contact Force-sensing-based catheter ablation
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
113 participants
Where
1 siteNetherlands
Study dates
12 Jun 2018to 20 Mar 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Referral for electrophysiology study because of pre-excitation on 12-lead surface ECG and/or documented (or suspected) symptomatic PSVT
  • Identification of AVNRT or WPW-AVRT (with manifest or concealed accessory pathway) during standard EP study
  • Verbal consent to continue with ablation therapy
  • Informed written consent to be included in the study

Who cannot join

  • evidence of structural heart disease and/or myocardial ischemia
  • pregnancy (and lack of exclusion of potential pregnancy)
  • age below 18 years

Trial locations and contacts

1 site in 1 country.

Netherlands1 site
  • Erasmus MC

    Rotterdam, 3015 GD

Other trials in Netherlands

About this study

Official title: Contact-Force-Sensing-Based Radiofrequency Catheter Ablation in Paroxysmal Supraventricular Tachycardias: a Randomized Controlled Trial

The aim of this single-center prospective randomized controlled trial is to assess the superiority of contact-force-(CF)-sensing-based approach compared to conventional (non-CF-sensing) approach in the catheter ablation of PSVTs, and to investigate the safety of open-irrigated, contact-force-sensing ablation catheters (used in a "non-irrigated" mode) in these procedures.

Read the detailed description

Rationale:

Multiple studies have demonstrated the importance of adequate catheter-tissue contact in the creation of effective lesions during radiofrequency catheter ablation. The development of contact-force(CF)-sensing catheters have contributed significantly to improve clinical outcomes in atrial fibrillation 3-18. However CF-sensing technology is not used in the ablation of paroxysmal supraventricular tachycardia. Although PSVT ablation with the conventional approach (non-irrigated, non-CF-sensing catheters) is considered a relatively low-risk procedure with fairly high success rate (short-and long-term) 1,2,19, we hypothesize that contact-force sensing can further improve the outcomes of these procedures. Based on the results of studies on atrial fibrillation ablation (mentioned above) we believe that CF-sensing could similarly improve such important parameters as radiofrequency (RF) application number/time, total procedure time, and fluoroscopy time in cases of PSVT ablations, as well. In addition CF-sensing could also further improve acute success/recurrence rates of PSVT ablation, and might also be capable to further diminish complication risk.

Primary Objective:

The primary objective of the present study is to demonstrate the superiority of contact-force-sensing in the ablation of AVNRT and WPW-AVRT as assessed by the improvement in the number and duration of radiofrequency applications compared with the conventional ablation approach.

Secondary Objective:

Secondary objectives of the study are the followings:

  • to demonstrate that contact-force-sensing catheters are superior in terms of total procedure duration and fluoroscopy times in the case of AVNRT/WPW-AVRT ablation.
  • to show that the use of contact-force sensing catheters is non-inferior to conventional catheters (without contact-force-sensing) in terms of acute/long-term procedural success and procedural safety (major/minor complication rate) of AVNRT/WPW-AVRT ablations.

Study population:

All patients above 18 years without structural heart disease being referred for electrophysiological study and potential treatment with radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) and atrioventricular reentrant tachycardia (AVRT) with manifest (WPW syndrome) or concealed accessory pathways.

Intervention:

One group undergoes manual ablation using standard non-irrigated ablation catheters and the other group undergoes manual ablation with an open-irrigated ablation catheter equipped with CF- sensing (and utilized in a non-irrigated mode during ablation)

Main study parameters/endpoints:

The main study endpoint is the difference in RF application number during the procedures of AVNRT/WPW-AVRT ablation; secondary endpoints are differences in RF application rate, acute success rate, long-term recurrence rate (1 year) major/minor complication rate, and total procedure/fluoroscopy time.

Being tested
Standard catheter ablation, Contact Force-sensing-based catheter ablation
Medical subject headings
Tachycardia, Ventricular, Tachycardia, Supraventricular

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Standard catheter ablationProcedure or surgery

    Radiofrequency catheter ablation using a standard ablation catheters: not equipped with contact-force sensing

  • Contact Force-sensing-based catheter ablationProcedure or surgery

    Radiofrequency catheter ablation using a Contact-Force-sensing ablation catheter

Study groups in NCT04078685
Study groupRoleWhat they receive
CONVENTIONAL groupActive comparatorPatients with supraventricular tachycardia treated with radiofrequency ablation using a standard (non-contact-force sensing) ablation catheter
Receives: Procedure: Standard catheter ablation
CONTACT-FORCE groupExperimentalPatients with supraventricular tachycardia treated with radiofrequency ablation using a Contact-Force-sensing ablation catheter
Receives: Procedure: Contact Force-sensing-based catheter ablation

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of radiofrequency applications

    The number of radiofrequency applications during the ablation procedures of AVNRT and WPW-AVRT

    Measured: From the beginning till the end of the ablation procedure

Secondary outcomes (7)
  1. Overall duration of radiofrequency applications

    total of time spend from the beginning till the end of the ablation procedure

    Measured: From the beginning till the end of the ablation procedure

  2. Long-term procedural success

    Free from recurrence of pre-excitation or the same clinical type of paroxysmal supraventricular tachycardia (AVNRT or AVRT)

    Measured: At 12 months

  3. Acute procedural success/failure

    non-inducibility of clinical arrhythmia verified at the end of the standard EP study

    Measured: at the end of the ablation procedure

  4. Fluoroscopy time

    total time for fluoroscopy time

    Measured: From the beginning till the end of the ablation procedure

  5. Total duration of procedure

    total time for duration of the procedure

    Measured: From the beginning till the end of the ablation procedure

  6. (Serious) Adverse Events

    all reported SAEs

    Measured: Till 12 months

  7. Time to recurrence of AVNRT/WPW-AVRT

    if recurrence of AVNRT/WPW-AVRT, time to recurrence

    Measured: up till 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Sep 2019
  2. Study start12 Jun 2018
  3. Primary completion9 Mar 2020
  4. Study completion20 Mar 2021 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
113 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04078685
Sponsor's protocol ID
NL62017.078.17
Acronym
COBRA-PATH
Status last verified
Sep 2020
First submitted
2 Sep 2019
Last updated
3 Sep 2020
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Ullah W, Hunter RJ, Haldar S, McLean A, Dhinoja M, Sporton S, Earley MJ, Lorgat F, Wong T, Schilling RJ. Comparison of robotic and manual persistent AF ablation using catheter contact force sensing: an international multicenter registry study. Pacing Clin Electrophysiol. 2014 Nov;37(11):1427-35. doi: 10.1111/pace.12501. Epub 2014 Sep 15.

    PubMed 25220575
  • Gerstenfeld EP. Contact force-sensing catheters: evolution or revolution in catheter ablation technology? Circ Arrhythm Electrophysiol. 2014 Feb;7(1):5-6. doi: 10.1161/CIRCEP.114.001424. No abstract available.

    PubMed 24550405
  • Shurrab M, Di Biase L, Briceno DF, Kaoutskaia A, Haj-Yahia S, Newman D, Lashevsky I, Nakagawa H, Crystal E. Impact of Contact Force Technology on Atrial Fibrillation Ablation: A Meta-Analysis. J Am Heart Assoc. 2015 Sep 21;4(9):e002476. doi: 10.1161/JAHA.115.002476.

    PubMed 26391136
  • Kautzner J, Neuzil P, Lambert H, Peichl P, Petru J, Cihak R, Skoda J, Wichterle D, Wissner E, Yulzari A, Kuck KH. EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation. Europace. 2015 Aug;17(8):1229-35. doi: 10.1093/europace/euv057. Epub 2015 Jun 3.

    PubMed 26041872
  • Kimura M, Sasaki S, Owada S, Horiuchi D, Sasaki K, Itoh T, Ishida Y, Kinjo T, Tomita H, Okumura K. Comparison of lesion formation between contact force-guided and non-guided circumferential pulmonary vein isolation: a prospective, randomized study. Heart Rhythm. 2014 Jun;11(6):984-91. doi: 10.1016/j.hrthm.2014.03.019. Epub 2014 Mar 18.

    PubMed 24657428
  • Kuck KH, Reddy VY, Schmidt B, Natale A, Neuzil P, Saoudi N, Kautzner J, Herrera C, Hindricks G, Jais P, Nakagawa H, Lambert H, Shah DC. A novel radiofrequency ablation catheter using contact force sensing: Toccata study. Heart Rhythm. 2012 Jan;9(1):18-23. doi: 10.1016/j.hrthm.2011.08.021. Epub 2011 Aug 26.

    PubMed 21872560
  • Martinek M, Lemes C, Sigmund E, Derndorfer M, Aichinger J, Winter S, Nesser HJ, Purerfellner H. Clinical impact of an open-irrigated radiofrequency catheter with direct force measurement on atrial fibrillation ablation. Pacing Clin Electrophysiol. 2012 Nov;35(11):1312-8. doi: 10.1111/j.1540-8159.2012.03503.x. Epub 2012 Sep 4.

    PubMed 22946636
  • Natale A, Reddy VY, Monir G, Wilber DJ, Lindsay BD, McElderry HT, Kantipudi C, Mansour MC, Melby DP, Packer DL, Nakagawa H, Zhang B, Stagg RB, Boo LM, Marchlinski FE. Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. J Am Coll Cardiol. 2014 Aug 19;64(7):647-56. doi: 10.1016/j.jacc.2014.04.072.

    PubMed 25125294
  • Ramdat Misier NL, Geczy T, Wijchers SA, Bhagwandien RE, Hoogendijk M, Mahmoodi BK, Szili-Torok T, Yap SC. Contact-force-sensing-based radiofrequency catheter ablation in paroxysmal supraventricular tachycardias: A randomized controlled trial. Heart Rhythm O2. 2026 Apr 15;7(7):1335-1343. doi: 10.1016/j.hroo.2026.04.007. eCollection 2026 Jul.

    PubMed 42488158
  • Geczy T, Ramdat Misier NL, Szili-Torok T. Contact-Force-Sensing-Based Radiofrequency Catheter Ablation in Paroxysmal Supraventricular Tachycardias (COBRA-PATH): a randomized controlled trial. Trials. 2020 Apr 9;21(1):321. doi: 10.1186/s13063-020-4219-1.

    PubMed 32272969

Questions about this trial

What is this clinical trial studying?

A study testing Standard catheter ablation and Contact Force-sensing-based catheter ablation in people with Tachycardia; Paroxysmal, Supraventricular and Tachycardia, Supraventricular, run by Erasmus Medical Center at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 3 Sep 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of radiofrequency applications (time frame: From the beginning till the end of the ablation procedure). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04078685, which also lists 10 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Sep 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in