AzTrials
AzTrials

Kidney CancerPhase 2NCT04021238

Contrast-Enhanced Ultrasound for Kidney Cancer Subtyping and Staging

A Phase 2 study testing Perflutren lipid microsphere and Sulfur hexafluoride lipid microspheres in people with Kidney Cancer, run by UNC Lineberger Comprehensive Cancer Center at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to determine if contrast-enhanced ultrasound can detect abnormal features of kidney lesions in patients with suspected kidney cancer with the same accuracy as conventional ultrasound and contrast-enhanced magnetic resonance imaging (MRI) Read more about this study

Who is it for?
Ages 18 to 99 years
Conditions the study is for
Kidney Cancer
What is being tested?
Perflutren lipid microsphere and Sulfur hexafluoride lipid microspheres
Type of treatment
Injection or infusion
Could I receive a placebo?
No, everyone receives an active treatment
How many people
25 participants
Where
1 siteUnited States
Study dates
7 Oct 2020to 5 Aug 2022
Phase
Phase 2
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 99 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • A suspected diagnosis of kidney cancer with a solid or partially solid lesion and planned surgical nephrectomy within 3 months before surgery
  • Able to provide informed consent
  • Willing to comply with protocol requirements
  • At least 18 years of age

Who cannot join

  • Critically ill or medically unstable or in an intensive care setting and whose critical course during a potential observation period would be unpredictable
  • Known hypersensitivity to sulfur hexafluoride or to any component of perflutren lipid (Definity®) or sulfur hexafluoride (Lumason®)
  • Right to left shunt, severe pulmonary hypertension (Pulmonary artery pressure >90mmHg), or adult respiratory distress syndrome
  • Has any other medical condition or other circumstances that would significantly decrease the chances of obtaining reliable data or of achieving the study objectives
  • Unstable cardiopulmonary disease including any of the following:
  • Severe congestive heart failure (class IV in accordance with the classification of the New York Heart Association)
Show all 11Show fewer
  • Unstable angina
  • Symptomatic arrhythmia (i.e. tachycardia, bradycardia, supraventricular tachycardia, ventricular fibrillation, ventricular tachycardia, atrial flutter or fibrillation)
  • Myocardial infarction within 14 days prior to the date of proposed microbubble administration.
  • Any woman who is pregnant or has reason to believe she is pregnant (the possibility of pregnancy has to be excluded by negative urine β-HCG results, obtained the same day as the CEUS, or on the basis of patient history, e.g.: tubal ligation, hysterectomy or a minimum of 1 year without menses)
  • Obesity that limits obtainment of acceptable images

Trial locations and contacts

1 site in 1 country.

United States1 site
  • University of North Carolina at Chapel Hill

    Chapel Hill, North Carolina, 27599

Other trials in United States

About this study

The purpose of this study is to determine if contrast-enhanced ultrasound can detect abnormal features of kidney lesions in patients with suspected kidney cancer with the same accuracy as conventional ultrasound and contrast-enhanced magnetic resonance imaging (MRI)

Read the detailed description

This is a pilot cross-sectional study that compares contrast enhanced ultrasound to conventional ultrasound and contrasted MRI. Eligible patients will include anyone who has suspected kidney cancer and is scheduled for surgery, up to an anticipated total of 40 participants. Subject participation will be only for the day of CEUS study. There will be no follow-up period for this study. However, if results are encouraging, a longitudinal observational study may follow, and these same subjects would be eligible for enrollment. Eligible subjects will undergo a contrast enhanced ultrasound.

Following completion of imaging, all CEUS, MRI (within 4 months) and B-mode (at time of CEUS) US studies will be de-identified. Blinded radiologists will interpret images and provide an overall assessment of risk of malignancy to each kidney using the Bosniak criteria for each kidney lesion present. The Bosniak criteria places cystic lesions into one of 5 categories (I, II, IIF, III and IV) based on lesion characteristics. CEUS based diagnosis will be compared to the diagnoses on routine B-mode US and contrast-enhanced MRI.

Conditions
Kidney Cancer
Being tested
Perflutren lipid microsphere, Sulfur hexafluoride lipid microspheres
Medical subject headings
Kidney Neoplasms

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Perflutren lipid microsphereDrug

    Also called Definity, Microbubble contrast agent

    Baseline B-mode US will be performed to confirm the lesions being imaged (unless it is a subject with no lesions, then a basic B-mode US will be performed. Perflutren is a diagnostic drug that is intended to be used for contrast enhancement. The vial contains a clear, colorless, sterile, non-pyrogenic, hypertonic solution which is activated by mechanical agitation with Vialmix®.It will be dispensed in inactivated form to a study team member. The contrast agent will be activated just prior to administration (ideally to be used within 5 minutes of activation). Contrast agent Definity (or Lumason) will be activated according to package insert instructions, including use of VialMix®, the device used to activate Definity. Administration will occur IV in coordination with sonography staff trained specifically in contrast ultrasound imaging.The total imaging time is anticipated to be less than 30 minutes.

  • Sulfur hexafluoride lipid microspheresDrug

    Also called Lumason

    Baseline B-mode US will be performed to confirm the lesions being imaged (unless it is a subject with no lesions, then a basic B-mode US will be performed. Lumason will be used as a secondary contrast agent only if Definity(perflutren) is unavailable.This drug will be administered using the dosing range and administration type within the Lumason prescribing information. The contrast agent will be activated just prior to administration (ideally to be used within 5 minutes of activation). Contrast agent Definity (or Lumason) will be activated according to package insert instructions, including use of VialMix®, the device used to activate Definity. Administration will occur IV in coordination with sonography staff trained specifically in contrast ultrasound imaging.The total imaging time is anticipated to be less than 30 minutes.

Study groups in NCT04021238
Study groupRoleWhat they receive
Perflutren Lipid Microsphere or LumasonExperimentalPatients with suspected kidney cancer and planned surgery will be imaged using contrast-enhanced ultrasound with either perflutren or Lumason.
Receives: Drug: Perflutren lipid microsphere; Drug: Sulfur hexafluoride lipid microspheres

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. 3D CEUS Generated Metrics in Kidney Mass: Wash_In_Slope

    A study-specific model was created to predict kidney tumor type. The contrast-enhanced ultrasonogram (CEUS) Wash_In_Slope parameter was generated. This metric indicates the change in contrast with time in the mass using bolus imaging. Bolus imaging injects a small amount of contrast agent and monitors the contrast agent as it flows in (wash-in) and out (wash-out) of the body/mass. The intensity of the signal (the brightness of the image) is plotted over time to generate the time-intensity curve. The intensity of the signal (the brightness of the image) values range between 0=black, and 255=White.The Wash_In_Slope increases as the contrast agent is introduced to the body/mass. This value was generated by fitting the data to a linear equation. Increasing brightness is related to the slope of curve.

    Measured: Baseline- up to 3 minutes

  2. 3D CEUS Generated Metric in Kidney Mass: Wash_In_intercept

    A study-specific model was created to predict kidney tumor type. The contrast-enhanced ultrasonogram (CEUS) Wash_In_intercept parameter was generated. This metric indicates the intensity level prior to infusion of contrast. The intensity of the signal (the brightness of the image) values range between 0=black, and 255=white. This value was calculated using an equation for a line which has a slope and the intercept. The values were negative because they were calculated (not measured).

    Measured: Baseline- up to 3 minutes

  3. 3D CEUS Generated Metric in Kidney Mass: Wash_Out_Slope

    A study-specific model was created to predict kidney tumor type. The contrast-enhanced ultrasonogram (CEUS) Wash_Out_Slope parameter was generated. This metric indicates the change in contrast with time in the mass using bolus imaging. Bolus imaging injects a small amount of contrast agent and monitors the contrast agent as it flows in (wash-in) and out (wash-out) of the body/mass. The intensity of the signal (the brightness of the image) is plotted over time to generate the time-intensity curve. The intensity of the signal (the brightness of the image) value range was between 0=black and 255=White. The wash Out slope decreases as the contrast agent clears the body/mass. Decreasing brightness is related to the slope of the curve. This results in a negative number. This value was generated by fitting the data to a linear equation.

    Measured: Baseline- up to 3 minutes

  4. 3D CEUS Generated Metric in Kidney Mass: Wash_Out_Intercept

    A study-specific model was created to predict kidney tumor type. The contrast-enhanced ultrasonogram (CEUS) Wash_Out_Intercept parameter was generated. This metric indicates the intensity level of contrast at a steady state of enhancement in the mass. The intensity of the signal (the brightness of the image) values range between 0=black, and 255=White. This value was calculated using an equation for a line that has a slope and an intercept.

    Measured: Baseline- up to 3 minutes

  5. 3D CEUS Generated Metric in Kidney Mass: FR_a

    A study-specific model was created to predict kidney tumor type. The contrast-enhanced ultrasonogram (CEUS) FR_a parameter was generated. The intensity of the signal (the brightness of the image) value range is between 0=black, and 255=white. The intensity was plotted by time. FR_a parameters were devised from an exponential fit. The exponential fit of the data provides the height of the curve.

    Measured: Baseline- up to 3 minutes

  6. 3D CEUS Generated Metric in Kidney Mass: FR_beta

    A study-specific model was created to predict kidney tumor type. The contrast-enhanced ultrasonogram (CEUS) FR_beta parameter was generated. The intensity of the signal (the brightness of the image) value range is between 0=black, 255=White. The intensity was plotted by time. FR_beta parameters were devised from an exponential fit. Exponential fit of the data provides the slope of the curve.

    Measured: Baseline- up to 3 minutes

  7. 3D CEUS Generated Metric in Kidney Mass: Volume

    A study-specific model was created to predict kidney tumor type. The contrast-enhanced ultrasonogram (CEUS) volume parameter was generated. The volumes were generated using the ellipsoid equation on the CEUS image of the kidney mass.

    Measured: Baseline- up to 3 minutes

  8. 3D CEUS Generated Metric in Kidney Mass - Histopathologic Type vs. Wash_In_Slope

    The association between tumor pathology type (Clear cell renal carcinoma (CCRCC) versus none (CCRCC) pathology) and CEUS-generated Wash_In_Slope parameter was studied. This metric indicates the change in contrast intensity with time in the mass using bolus imaging. The intensity of the signal (the brightness of the image) values range between 0=black, and 255=White. The Wash_In_Slope increases as the contrast agent is introduced to the body/mass. This value was generated by fitting the data to a linear equation. Increasing brightness is related to the slope of the curve.

    Measured: Baseline- up to 3 minutes

  9. 3D CEUS Generated Metric in Kidney Mass - Histopathologic Type vs. Wash_In_intercept

    The association between tumor pathology type (Clear cell renal carcinoma (CCRCC) versus none (CCRCC) pathology) and CEUS-generated Wash_In_intercept parameter was studied. This metric indicates the intensity level prior to infusion of contrast. The intensity of the signal (the brightness of the image) value range is between 0=black, and 255=White. This value was calculated using an equation for a line which has a slope and the intercept. The values were negative because they were calculated (not measured).

    Measured: Baseline- up to 3 minutes

  10. 3D CEUS Generated Metric in Kidney Mass - Histopathologic Type vs. Wash_Out_Slope

    The association between tumor pathology type (Clear cell renal carcinoma (CCRCC) versus none (CCRCC) pathology) and CEUS-generated Wash_Out_Slope parameter was studied. This metric indicates the change in contrast intensity with time in the mass using bolus imaging. The intensity of the signal (the brightness of the image) value range is between 0=black, and 255=White. Decreasing brightness is related to the slope of the curve. The Wash Out slope decreases as the contrast agent clears the body/mass. Decreasing brightness is related to the slope of the curve. This results in a negative number. This value was generated by fitting the data to a linear equation.

    Measured: Baseline- up to 3 minutes

  11. 3D CEUS Generated Metric in Kidney Mass - Histopathologic Type vs. Wash_Out_Intercept

    The association between tumor pathology type (Clear cell renal carcinoma (CCRCC) versus none (CCRCC) pathology) and CEUS-generated Wash_Out_Intercept parameter was studied. This metric indicates the intensity level of contrast at steady state of enhancement in the mass. The contrast-enhanced ultrasonogram (CEUS) Wash_Out_Intercept parameter was generated. The intensity of the signal (the brightness of the image) value range is between 0=black, and 255=White. This value was calculated using an equation for a line which has a slope and the intercept.

    Measured: Baseline- up to 3 minutes

  12. 3D CEUS Generated Metric in Kidney Mass - Histopathologic Type vs. FR_a

    The association between tumor pathology type (Clear cell renal carcinoma (CCRCC) versus none (CCRCC) pathology) and CEUS-generated FR_a parameter was studied. The intensity of the signal (the brightness of the image) values range between 0=black, and 255=White. The intensity was plotted by time. FR_a parameters were devised from an exponential fit. The exponential fit of the data provides the height of the curve.

    Measured: Baseline- up to 3 minutes

  13. 3D CEUS Generated Metric in Kidney Mass - Histopathologic Type vs. FR_beta

    The association between tumor pathology type (Clear cell renal carcinoma (CCRCC) versus none (CCRCC) pathology) and CEUS-generated FR_ beta parameter was studied. The contrast-enhanced ultrasonogram (CEUS) FR_beta parameter was generated. The intensity of the signal (the brightness of the image) values range between 0=black, and 255=White. The intensity was plotted by time. FR_beta parameters were devised from an exponential fit. The exponential fit of the data provides the slope of the curve.

    Measured: Baseline- up to 3 minutes

  14. 3D CEUS Generated Metric in Kidney Mass - Histopathologic Type vs. Volume

    The association between tumor pathology type (Clear cell renal carcinoma (CCRCC) versus none (CCRCC) pathology) and CEUS-generated volume parameter was studied. The volumes were generated using the ellipsoid equation on the CEUS image of the kidney mass.

    Measured: Baseline- up to 3 minutes

Secondary outcomes (9)
  1. 3D CEUS Generated Metric in Kidney Mass - Tumor Stage vs. Wash_In_Slope

    The intensity of the signal (the brightness of the image) is plotted over time to generate the time-intensity curve. The intensity of the signal (the brightness of the image) values range between 0=black and 255=White. The Wash_In_Slope increases as the contrast agent is introduced to the body/mass. This value was generated by fitting the data to a linear equation. Increasing brightness is related to the slope of the curve. The association between tumor stage (Tumor stage 0,1,2,3) and CEUS-generated Wash_In_Slope parameter was studied.

    Tumor staging is based on the size of the mass, spread to lymph nodes, and metastasis to distant sites according to American Joint Cancer Committee. All masses in this study were in stage 0, I, II or III (not stage IV). Stage 0 = cancer cell was not found on pathology. Stage I =tumors size ≤7 cm. Stage II = tumor size >7 cm. Stage III includes tumors that are growing into a major vein or tissue around the kidney with no spread to lymph nodes.

    Measured: Baseline- up to 3 minutes

  2. 3D CEUS Generated Metric in Kidney Mass - Tumor Stage vs. Wash_In_intercept

    The association between tumor stage and CEUS-generated Wash_In_intercept parameter was studied. These values were generated by fitting the data to a linear equation. This metric indicates the intensity level prior to infusion of contrast. The intensity of the signal (the brightness of the image) value range is between 0=black, and 255=White. This value was calculated using an equation for a line that has a slope and an intercept. The values were negative because they were calculated (not measured).

    Tumor staging is based on the size of the mass, spread to lymph nodes, and metastasis to distant sites according to the American Joint Cancer Committee. All masses in this study were in stage 0, I, II, or III (not stage IV). Stage 0 = cancer cell was not found on pathology. Stage I =tumors size ≤7 cm. Stage II = tumor size >7 cm. Stage III includes tumors that are growing into a major vein or tissue around the kidney with no spread to lymph nodes.

    Measured: Baseline- up to 3 minutes

  3. 3D CEUS Generated Metric in Kidney Mass - Tumor Stage vs. Wash_Out_Slope

    The association between tumor stage (Tumor stage 0,1,2,3) and CEUS-generated Wash_Out_Slope parameter was studied. The intensity of the signal (the brightness of the image) is plotted over time to generate the time-intensity curve. The intensity of the signal (the brightness of the image) values range between 0=black, and 255=White. The Wash_Out_Slope decreases as the contrast agent clears the body/mass. Decreasing brightness is related to the slope of the curve. This results in a negative number. This value was generated by fitting the data to a linear equation. Tumor staging is based on the size of the mass, spread to lymph nodes, and metastasis to distant sites according to the AJCC. All masses in this study were in stage 0, I, II, or III (not stage IV). Stage 0 = cancer cell was not found on pathology. Stage I =tumors size ≤7 cm. Stage II = tumor size >7 cm, Stage III includes tumors that are growing into a major vein or tissue around the kidney with no spread to lymph nodes.

    Measured: Baseline- up to 3 minutes

  4. 3D CEUS Generated Metric in Kidney Mass - Tumor Stage vs. Wash_Out_Intercept

    The association between tumor stage (Tumor stage 0,1,2,3) and CEUS-generated Wash_Out_Intercept parameter was studied. This metric indicates the intensity level of contrast at a steady state of enhancement in the mass. The contrast-enhanced ultrasonogram (CEUS) Wash_Out_Intercept parameter was generated. The intensity of the signal (the brightness of the image) value range is between 0=black, and 255=White. This value was calculated using an equation for a line that has a slope and the intercept.

    Tumor staging is based on the size of the mass, spread to lymph nodes, and metastasis to distant sites according to the American Joint Cancer Committee. All masses in this study were in stage 0, I, II, or III (not stage IV). Stage 0 = cancer cell was not found on pathology. Stage I =tumors size ≤7 cm. Stage II = tumor size >7 cm. Stage III includes tumors that are growing into a major vein or tissue around the kidney with no spread to lymph nodes.

    Measured: Baseline- up to 3 minutes

  5. 3D CEUS Generated Metric in Kidney Mass - Tumor Stage vs. FR_a

    The association between tumor stage (Tumor stage 0,1,2,3) and CEUS-generated FR_a parameter was studied. The intensity of the signal (the brightness of the image) values range between 0=black, and 255=White. The intensity was plotted by time. FR_a parameters were devised from an exponential fit. The exponential fit of the data provides the height of the curve.

    Tumor staging is based on the size of the mass, spread to lymph nodes, and metastasis to distant sites according to the American Joint Cancer Committee. All masses in this study were in stage 0, I, II or III (not stage IV). Stage 0 = cancer cell was not found on pathology. Stage I =tumors size ≤7 cm. Stage II = tumor size >7 cm. Stage III includes tumors that are growing into a major vein or tissue around the kidney with no spread to lymph nodes.

    Measured: Baseline- up to 3 minutes

  6. 3D CEUS Generated Metric in Kidney Mass - Tumor Stage vs. FR_beta

    The association between tumor stage (Tumor stage 0,1,2,3) and CEUS-generated FR_ beta parameter was studied. The contrast-enhanced ultrasonogram (CEUS) FR_beta parameter was generated. The intensity of the signal (the brightness of the image) values range between 0=black, and 255=White. The intensity was plotted by time. FR_beta parameters were devised from an exponential fit. The exponential fit of the data provides the slope of the curve.

    Tumor staging is based on the size of the mass, spread to lymph nodes, and metastasis to distant sites according to the American Joint Cancer Committee. All masses in this study were in stage 0, I, II, or III (not stage IV). Stage 0 = cancer cell was not found on pathology. Stage I =tumors size ≤7 cm. Stage II = tumor size >7 cm. Stage III includes tumors that are growing into a major vein or tissue around the kidney with no spread to lymph nodes.

    Measured: Baseline- up to 3 minutes

  7. 3D CEUS Generated Metric in Kidney Mass - Tumor Stage vs. Volume

    The association between tumor stage (Tumor stage 0,1,2,3) and CEUS-generated volume was studied. The contrast-enhanced ultrasonogram (CEUS) volume was generated.

    Tumor staging is based on the size of the mass, spread to lymph nodes, and metastasis to distant sites according to the American Joint Cancer Committee. All masses in this study were in stage 0, I, II or III (not stage IV). Stage 0 = cancer cell was not found on pathology. Stage I =tumors size ≤7 cm. Stage II = tumor size >7 cm. Stage III includes tumors that are growing into a major vein or tissue around the kidney with no spread to lymph nodes.

    Measured: Baseline- up to 3 minutes

  8. Pooled Kidney Mass Stage vs. 3D CEUS-generated Wash in Metrics

    The association between pooled tumor stage (tumor stages 0,1,2 versus tumor stage 3) and CEUS-generated Wash_In_Slope parameter was studied. The intensity of the signal (the brightness of the image) is plotted over time to generate the time-intensity curve. The intensity of the signal values range between 0=black and 255=White. The Wash_In_Slope increases as the contrast agent is introduced to the body/mass. This value was generated by fitting the data to a linear equation. Increasing brightness is related to the slope of the curve. Tumor staging is based on the size of the mass, spread to lymph nodes, and metastasis to distant sites according to the American Joint Cancer Committee. All masses in this study were in stage 0, I, II, or III (not stage IV). Stage 0 = cancer cell was not found on pathology. Stage I =tumors size ≤7 cm. Stage II = tumor size >7 cm. Stage III includes tumors that are growing into a major vein or tissue around the kidney with no spread to lymph nodes.

    Measured: Baseline- up to 3 minutes

  9. Pooled Kidney Mass Stage Using 3D CEUS-generated Wash Out Metrics

    The association between pooled tumor stage (tumor stages 0,1,2 versus tumor stage 3) and CEUS-generated Wash_Out_Slope parameter was studied. The intensity of the signal (the brightness of the image) is plotted over time to generate the time-intensity curve. The intensity of the signal (the brightness of the image) values range between 0=black, and 255=White. The Wash_Out_Slope decreases as the contrast agent clears the body/mass. Decreasing brightness is related to the slope of the curve. This results in a negative number. This value was generated by fitting the data to a linear equation. Tumor staging is based on the size of the mass, spread to lymph nodes, and metastasis to distant sites according to the AJCC. All masses in this study were in stage 0, I, II, or III (not stage IV). Stage 0 = cancer cell was not found, Stage I = tumor size ≤7 cm, Stage II = tumor size >7 cm, Stage III includes tumors growing into a major vein or tissue, with no spread to lymph nodes.

    Measured: Baseline- up to 3 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 Jul 2019
  2. Study start7 Oct 2020
  3. Primary completion5 Aug 2022
  4. Study completion5 Aug 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 2
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
25 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04021238
Sponsor's protocol ID
LCCC1922
Status last verified
Oct 2023
First submitted
11 Jul 2019
Last updated
13 Nov 2023
Data monitoring committee
Yes
FDA-regulated drug
Yes
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A Phase 2 study testing Perflutren lipid microsphere and Sulfur hexafluoride lipid microspheres in people with Kidney Cancer, run by UNC Lineberger Comprehensive Cancer Center at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 13 Nov 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Yes. Results are posted in the registry (first posted 13 Nov 2023). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

3D CEUS Generated Metrics in Kidney Mass: Wash_In_Slope (time frame: Baseline- up to 3 minutes). The study lists 14 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Nov 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in