CgmGRACENCT03981328
Real-time Continuous Glucose Monitoring for Reduced Adverse Complications and Events in Women With Gestational Diabetes (GRACE): a Multicentre International Randomized Controlled Trial
A study testing Dexcom G6 Continuous Glucose Monitoring System and self-monitored blood glucose in people with Cgm and Gestational Diabetes, run by Medical University of Vienna at 1 site in Austria.
Trial summary
Real-time continuous glucose monitoring (CGM) systems provide users with information about current glucose levels and alert the patient before the upper or lower glucose threshold is reached or when glucose levels change rapidly. Read more about this study
- Who is it for?
- Ages 18 to 55 years, women only
- Conditions the study is for
- Cgm, Gestational Diabetes, Pregnancy Complications
- What is being tested?
- Dexcom G6 Continuous Glucose Monitoring System and self-monitored blood glucose
- Type of treatment
- Injection or infusion, Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 375 participants
- Where
- 1 siteAustria
- Study dates
- 24 Aug 2020to 28 Feb 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 55 years
- Women only
- No healthy volunteers
- Adult
Who may be able to join
- female patients between 18 and 55 years
- gestational diabetes mellitus in accordance with the IADPSG criteria between 24 and 31+6 weeks of gestation by a 2h 75g OGTT
- If the GDM diagnosis is made before 24+0 weeks of gestation in accordance with the local guideline (i.e. when IADPSG cut-offs for fasting and post-load glucose are exceeded) patients can be included if no insulin treatment was started until 24+0
Who cannot join
- Overt diabetes (i.e. pregestationally known type 1 or type 2 diabetes or fasting plasma glucose during the OGTT ≥126 mg/dl [7.0 mmol/l] or HbA1c ≥6.5% [44 mmol/l] or 2h post-load OGTT levels ≥200 mg/dl [11.1 mmol/l] assessed before 24+0 weeks of gestation
- history of bariatric surgery or other surgeries that induce malabsorption
- long-term use (>2 weeks) of systemic steroids prior to enrolment
- multiple pregnancy
- Patients already using glucose lowering medications (metformin or insulin) before study entry
- fetal growth restriction due to placental dysfunction at study entry - Inpatient psychiatric treatment up to 1 year before enrolment
- Participation in this study in previous pregnancy
Trial locations and contacts
1 site in 1 country.
Austria1 site
Department of Obstetrics and Gynecology, Division of Obstetrics and Feto-maternal Medicine, Medical University of Vienna
Vienna, 1090
About this study
Official title: The Effectiveness of Real Time Continuous Glucose Monitoring to Improve Glycemic Control and Pregnancy Outcome in Patients With Gestational Diabetes Mellitus
Real-time continuous glucose monitoring (CGM) systems provide users with information about current glucose levels and alert the patient before the upper or lower glucose threshold is reached or when glucose levels change rapidly. Hence, glycaemic excursions can be early identified and accordingly adapted by behavioural change or pharmacologic intervention. Randomized controlled studies adequately powered to evaluate the impact of long-term application of real-time CGM systems on the risk reduction of adverse obstetric outcomes are missing.
Read the detailed description
Intervention: Device description The Dexcom G6 intended use is for the management of diabetes in persons aged 2 years and older. The Dexcom G6 System is intended to replace fingerstick blood glucose testing for diabetes treatment decisions. Interpretation of the Dexcom G6 System results should be based on the glucose trends and several sequential readings over time. The Dexcom G6 System also aids in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments. The Dexcom G6 System can be used alone or in conjunction with these digitally connected medical devices for the purpose of managing diabetes. The system consists of a sensor, transmitter, receiver, and mobile app. The sensor is a small, flexible wire inserted into subcutaneous tissue where it converts glucose into electrical current. The sensor incorporates an interferent layer that minimizes the effect of potential electroactive interferents, such as acetaminophen, by preventing it from reaching the sensor wire surface. The benefit of this interferent layer in blocking the effects of acetaminophen prevents falsely high glucose readings. Thus, users may ingest acetaminophen while wearing the G6 CGM system. The transmitter, which is connected to the sensor and worn on the body, samples the electrical current produced by the sensor and converts the measurement into a glucose reading using an onboard algorithm. The receiver and/or the app displays the glucose reading along with a rate of change arrow and a trend graph. Additionally, the receiver and/or app issues alarms and alerts to notify the patient of glucose level changes and other important system conditions. The app provides the additional capability to share data with "followers" using the Dexcom Share service. The receiver can be put into a blinded mode using CLARITY® software. In this mode, users are unable to see the CGM data or receive CGM alerts.
CGM Ancillary Devices Dexcom CLARITY® is an accessory to users of the Dexcom CGM system. It is a software program that allows the transfer of glucose data from the CGM system to Dexcom remote servers for data management to allow use of the CGM data by the user and study clinicians. Target ranges of 60 to 140 mg/dl [3.3 to 7.8 mmol/l] will be set and the patients will be introduced in the use of alarm settings. Both participants and study sites will use CLARITY® to transfer glucose data between user and study site, whether CGM is used in blinded or real-time mode. A CLARITY® mobile app can be used for retrospective review of glucose data on the smart device and can also be set up to allow receipt of push notifications of CGM data facilitating weekly data review. For all patients (intervention and control group) an anonymized CLARITY® account will be created by using a sequential study number which is allocated at randomization (sex will be female and birth date for each account will be set to 1.1.1990 for all accounts).
- For participants that have a supported phone, the G6 CGM app will be installed on participant's smart phone.
- An anonymized CLARITY® mobile account will be set up and linked to the research site.
- Participants will use CGM data for their diabetes management.
- A high alert threshold will be set at 140 mg/dl [7.8 mmol/l]. Low alert threshold and urgent low soon alerts will be turned off. If participants require insulin, the low alert will be turned on and the threshold set at 65 mg/dl [3.6 mmol/l]. In addition, the urgent low alert (55 mg/dl [3.1 mmol/l]), the urgent low soon alert (when glucose levels are falling fast and will be below 55 mg/dl [3.1 mmol/l] in less than 20 min) as well as alerts for rise and fall rate (3 mg/dl [0.17 mmol/l]) in addition to alerts for signal loss and no readings for more than 20 min will be enabled. 6. Participants with applicable smart phones may have CLARITY® push notifications on the CLARITY® mobile app about weekly time in range comparison enabled during the study.
- For app users, the "Share and Follow" functionality will be discussed and encouraged (i.e. the study participants are able to invite followers to review their glucose levels).
- For participants using the receiver only, the receiver will be downloaded into the CLARITY® clinic account at each visit. 9. For participants using real-time CGM data summary will be downloaded for documentation at V3 and V4 (between 36+0 and 38+6) as well as after delivery (VPP1) 10. The research team will review the CGM in CLARITY® to inform lifestyle and therapy recommendations. 11. The Dexcom G6 system will not be calibrated during the study period.
- Conditions
- Cgm, Gestational Diabetes, Pregnancy Complications, Blood Glucose, GDM
- Being tested
- Dexcom G6 Continuous Glucose Monitoring System, self-monitored blood glucose
- Medical subject headings
- Diabetes, Gestational, Pregnancy Complications
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Dexcom G6 Continuous Glucose Monitoring SystemDevice
Users insert a tiny sensor wire just under their skin using an automatic applicator. The sensor can measure glucose readings in interstitial fluid throughout the day and night.
self-monitored blood glucoseDevice
Each participant in the control group will be assigned a study blood glucose meter to measure and store their blood glucose values during the study. Therefore, the Contour® Next One system (or a comparable device) will be used. The meter has CE Mark clearance and is commercially available in Europe. Participants will receive an ample supply of meter test materials based on quantities routinely used.
| Study group | Role | What they receive |
|---|---|---|
| self-monitored blood glucose | Active comparator | The control group participants will perform self-monitored blood glucose testing with a study-provided blood glucose meter, including testing supplies. They will perform capillary blood glucose monitoring as routinely used for patients with GDM i.e. at least four capillary blood glucose values daily including measurements at fasting as well as 1h after starting each meal by using a routinely available blood glucose measurement device. Receives: Device: self-monitored blood glucose |
| Continuous glucose monitoring | Experimental | Patients randomized to the intervention group will be equipped with a real-time CGM sensor (Dexcom G6 sensor, a small flexible device that records interstitial glucose levels every five minutes). The sensor will be inserted into the subcutaneous tissue of the anterior abdomen wall. Additionally, patients will be advised to record capillary blood glucose values if glucose alerts or readings do not match with symptoms or expectations. Participants will be educated how to exchange the sensor (has to be exchanged every ten days) and will be equipped with a real-time CGM monitor and instructed in its use. The monitor provides the user with information about current glucose levels and notifies the patient before she reaches her upper or lower glucose threshold and when glucose levels change rapidly. All patients in the intervention group will specifically trained how to use the system. Receives: Device: Dexcom G6 Continuous Glucose Monitoring System |
What is being measured
The primary outcome is the main question the study is designed to answer.
LGA newborns
To assess differences in the proportion of LGA newborns (birth weight >90. pct) in women with GDM using real-time CGM as compared to women with GDM using SMBG via capillary blood glucose monitoring.
Measured: postpartum - up to 48 hours after delivery
Secondary outcomes (12)
neonatal hypoglycaemia
newborn measurement
Measured: postpartum - up to 48 hours after delivery
rate of caesarean section
statistics
Measured: postpartum - up to 48 hours after delivery
shoulder dystocia
frequency of occurrences
Measured: postpartum - up to 48 hours after delivery
neonatal anthropometry
newborn measurement
Measured: postpartum - up to 48 hours after delivery
differences in neonatal hyperinsulinemia
differences in neonatal hyperinsulinemia
Measured: postpartum - up to 48 hours after delivery
CGM measures such as mean, glycaemic variability, time in range as well as hyper- and hypoglycaemia
maternal measurements
Measured: through study completion, an average of 9 months
duration and frequency postprandial hyperglycaemic excursions
maternal
Measured: through study completion, an average of 9 months
start and amount of glucose lowering therapy
development until birth
Measured: through study completion, an average of 9 months
HbA1c
maternal measurements
Measured: through study completion, an average of 9 months
glycosylated Fibronectin
maternal measurements
Measured: through study completion, an average of 9 months
change in bodyweight during pregnancy and after delivery as well as glucose disposal at postpartum
development until birth
Measured: through study completion, an average of 1 year
Health-related quality of life
development until birth
Measured: through study completion, an average of 9 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted10 Jun 2019
- Study start24 Aug 2020
- Primary completion24 Aug 2024
- Study completion28 Feb 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for CgmStudies of the same condition, open and under way.
- More trials run by Medical University of ViennaThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 375 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medical University of Vienna
- Sponsor type
- University, hospital or other
- Collaborators
- University Hospital, Basel, Switzerland, Charite University, Berlin, Germany, The National Research Council, Italy, Università Politecnica delle Marche, DexCom, Inc., Jena University Hospital, German Diabetes Center
- Responsible party
- Principal investigator, Christian Göbl, Medical University of Vienna
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03981328
- Sponsor's protocol ID
- 20181101
- Acronym
- GRACE
- Status last verified
- Mar 2025
- First submitted
- 15 Feb 2019
- Last updated
- 2 Apr 2025
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Publications
Linder T, Dressler-Steinbach I, Wegener S, Schellong K, Schmidt S, Eppel D, Monod C, Heinzl F, Redling K, Winzeler B, Mosimann B, Weschenfelder F, Groten T, Mittlbock M, Jendle J, Henrich W, Morettini M, Bozkurt L, Tura A, Gobl C; GRACE study collaborative group. Glycaemic control and pregnancy outcomes with real-time continuous glucose monitoring in gestational diabetes (GRACE): an open-label, multicentre, multinational, randomised controlled trial. Lancet Diabetes Endocrinol. 2026 Jan;14(1):50-61. doi: 10.1016/S2213-8587(25)00288-8. Epub 2025 Nov 24.
PubMed 41308662Huhn EA, Linder T, Eppel D, Weisshaupt K, Klapp C, Schellong K, Henrich W, Yerlikaya-Schatten G, Rosicky I, Husslein P, Chalubinski K, Mittlbock M, Rust P, Hoesli I, Winzeler B, Jendle J, Fehm T, Icks A, Vomhof M, Greiner GG, Szendrodi J, Roden M, Tura A, Gobl CS. Effectiveness of real-time continuous glucose monitoring to improve glycaemic control and pregnancy outcome in patients with gestational diabetes mellitus: a study protocol for a randomised controlled trial. BMJ Open. 2020 Nov 30;10(11):e040498. doi: 10.1136/bmjopen-2020-040498.
PubMed 33257486
Study at a glance
From the registry record, last updated by the sponsor on 2 Apr 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The Effectiveness of Real Time Continuous Glucose Monitoring to Improve Glycemic Control and Pregnancy Outcome in Patients With Gestational Diabetes Mellitus
- ClinicalTrials.gov ID
- NCT03981328
- Acronym / sponsor ID
- GRACE / 20181101
- Conditions
- Cgm, Gestational Diabetes, Pregnancy Complications, Blood Glucose, GDM
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 375 participants (actual)
- Lead sponsor
- Medical University of ViennaUniversity, hospital or other
- Collaborators
- University Hospital, Basel, Switzerland, Charite University, Berlin, Germany, The National Research Council, Italy, Università Politecnica delle Marche, DexCom, Inc., Jena University Hospital, German Diabetes Center
- Study start
- 24 Aug 2020 (actual)
- Primary completion
- 24 Aug 2024 (actual)
- Study completion
- 28 Feb 2025 (actual)
- First posted
- 10 Jun 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Real-time continuous glucose monitoring (CGM) systems provide users with information about current glucose levels and alert the patient before the upper or lower glucose threshold is reached or when glucose levels change rapidly. Hence, glycaemic excursions can be early identified and accordingly adapted by behavioural change or pharmacologic intervention. Randomized controlled studies adequately powered to evaluate the impact of long-term application of real-time CGM systems on the risk reduction of adverse obstetric outcomes are missing.
Detailed description
Intervention: Device description The Dexcom G6 intended use is for the management of diabetes in persons aged 2 years and older. The Dexcom G6 System is intended to replace fingerstick blood glucose testing for diabetes treatment decisions. Interpretation of the Dexcom G6 System results should be based on the glucose trends and several sequential readings over time. The Dexcom G6 System also aids in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments. The Dexcom G6 System can be used alone or in conjunction with these digitally connected medical devices for the purpose of managing diabetes. The system consists of a sensor, transmitter, receiver, and mobile app. The sensor is a small, flexible wire inserted into subcutaneous tissue where it converts glucose into electrical current. The sensor incorporates an interferent layer that minimizes the effect of potential electroactive interferents, such as acetaminophen, by preventing it from reaching the sensor wire surface. The benefit of this interferent layer in blocking the effects of acetaminophen prevents falsely high glucose readings. Thus, users may ingest acetaminophen while wearing the G6 CGM system. The transmitter, which is connected to the sensor and worn on the body, samples the electrical current produced by the sensor and converts the measurement into a glucose reading using an onboard algorithm. The receiver and/or the app displays the glucose reading along with a rate of change arrow and a trend graph. Additionally, the receiver and/or app issues alarms and alerts to notify the patient of glucose level changes and other important system conditions. The app provides the additional capability to share data with "followers" using the Dexcom Share service. The receiver can be put into a blinded mode using CLARITY® software. In this mode, users are unable to see the CGM data or receive CGM alerts.
CGM Ancillary Devices Dexcom CLARITY® is an accessory to users of the Dexcom CGM system. It is a software program that allows the transfer of glucose data from the CGM system to Dexcom remote servers for data management to allow use of the CGM data by the user and study clinicians. Target ranges of 60 to 140 mg/dl [3.3 to 7.8 mmol/l] will be set and the patients will be introduced in the use of alarm settings. Both participants and study sites will use CLARITY® to transfer glucose data between user and study site, whether CGM is used in blinded or real-time mode. A CLARITY® mobile app can be used for retrospective review of glucose data on the smart device and can also be set up to allow receipt of push notifications of CGM data facilitating weekly data review. For all patients (intervention and control group) an anonymized CLARITY® account will be created by using a sequential study number which is allocated at randomization (sex will be female and birth date for each account will be set to 1.1.1990 for all accounts).
- For participants that have a supported phone, the G6 CGM app will be installed on participant's smart phone.
- An anonymized CLARITY® mobile account will be set up and linked to the research site.
- Participants will use CGM data for their diabetes management.
- A high alert threshold will be set at 140 mg/dl [7.8 mmol/l]. Low alert threshold and urgent low soon alerts will be turned off. If participants require insulin, the low alert will be turned on and the threshold set at 65 mg/dl [3.6 mmol/l]. In addition, the urgent low alert (55 mg/dl [3.1 mmol/l]), the urgent low soon alert (when glucose levels are falling fast and will be below 55 mg/dl [3.1 mmol/l] in less than 20 min) as well as alerts for rise and fall rate (3 mg/dl [0.17 mmol/l]) in addition to alerts for signal loss and no readings for more than 20 min will be enabled. 6. Participants with applicable smart phones may have CLARITY® push notifications on the CLARITY® mobile app about weekly time in range comparison enabled during the study.
- For app users, the "Share and Follow" functionality will be discussed and encouraged (i.e. the study participants are able to invite followers to review their glucose levels).
- For participants using the receiver only, the receiver will be downloaded into the CLARITY® clinic account at each visit. 9. For participants using real-time CGM data summary will be downloaded for documentation at V3 and V4 (between 36+0 and 38+6) as well as after delivery (VPP1) 10. The research team will review the CGM in CLARITY® to inform lifestyle and therapy recommendations. 11. The Dexcom G6 system will not be calibrated during the study period.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| self-monitored blood glucose | Active comparator | Device: self-monitored blood glucoseThe control group participants will perform self-monitored blood glucose testing with a study-provided blood glucose meter, including testing supplies. They will perform capillary blood glucose monitoring as routinely used for patients with GDM i.e. at least four capillary blood glucose values daily including measurements at fasting as well as 1h after starting each meal by using a routinely available blood glucose measurement device. |
| Continuous glucose monitoring | Experimental | Device: Dexcom G6 Continuous Glucose Monitoring SystemPatients randomized to the intervention group will be equipped with a real-time CGM sensor (Dexcom G6 sensor, a small flexible device that records interstitial glucose levels every five minutes). The sensor will be inserted into the subcutaneous tissue of the anterior abdomen wall. Additionally, patients will be advised to record capillary blood glucose values if glucose alerts or readings do not match with symptoms or expectations. Participants will be educated how to exchange the sensor (has to be exchanged every ten days) and will be equipped with a real-time CGM monitor and instructed in its use. The monitor provides the user with information about current glucose levels and notifies the patient before she reaches her upper or lower glucose threshold and when glucose levels change rapidly. All patients in the intervention group will specifically trained how to use the system. |
Who may qualify
- Ages
- 18 to 55 years
- Sex
- Female only
- Healthy volunteers
- Not accepted
- Age groups
- Adult
Key inclusion criteria (3 listed)
- female patients between 18 and 55 years
- gestational diabetes mellitus in accordance with the IADPSG criteria between 24 and 31+6 weeks of gestation by a 2h 75g OGTT
- If the GDM diagnosis is made before 24+0 weeks of gestation in accordance with the local guideline (i.e. when IADPSG cut-offs for fasting and post-load glucose are exceeded) patients can be included if no insulin treatment was started until 24+0
Key exclusion criteria (7 listed)
- Overt diabetes (i.e. pregestationally known type 1 or type 2 diabetes or fasting plasma glucose during the OGTT ≥126 mg/dl [7.0 mmol/l] or HbA1c ≥6.5% [44 mmol/l] or 2h post-load OGTT levels ≥200 mg/dl [11.1 mmol/l] assessed before 24+0 weeks of gestation
- history of bariatric surgery or other surgeries that induce malabsorption
- long-term use (>2 weeks) of systemic steroids prior to enrolment
- multiple pregnancy
- Patients already using glucose lowering medications (metformin or insulin) before study entry
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Dexcom G6 Continuous Glucose Monitoring SystemUsers insert a tiny sensor wire just under their skin using an automatic applicator. The sensor can measure glucose readings in interstitial fluid throughout the day and night. | Device | Continuous glucose monitoring |
| self-monitored blood glucoseEach participant in the control group will be assigned a study blood glucose meter to measure and store their blood glucose values during the study. Therefore, the Contour® Next One system (or a comparable device) will be used. The meter has CE Mark clearance and is commercially available in Europe. Participants will receive an ample supply of meter test materials based on quantities routinely used. | Device | self-monitored blood glucose |
Primary outcome
LGA newborns
Time frame: postpartum - up to 48 hours after delivery
To assess differences in the proportion of LGA newborns (birth weight >90. pct) in women with GDM using real-time CGM as compared to women with GDM using SMBG via capillary blood glucose monitoring.
12 secondary outcomes
neonatal hypoglycaemia
Time frame: postpartum - up to 48 hours after delivery
rate of caesarean section
Time frame: postpartum - up to 48 hours after delivery
shoulder dystocia
Time frame: postpartum - up to 48 hours after delivery
neonatal anthropometry
Time frame: postpartum - up to 48 hours after delivery
differences in neonatal hyperinsulinemia
Time frame: postpartum - up to 48 hours after delivery
CGM measures such as mean, glycaemic variability, time in range as well as hyper- and hypoglycaemia
Time frame: through study completion, an average of 9 months
duration and frequency postprandial hyperglycaemic excursions
Time frame: through study completion, an average of 9 months
start and amount of glucose lowering therapy
Time frame: through study completion, an average of 9 months
HbA1c
Time frame: through study completion, an average of 9 months
glycosylated Fibronectin
Time frame: through study completion, an average of 9 months
change in bodyweight during pregnancy and after delivery as well as glucose disposal at postpartum
Time frame: through study completion, an average of 1 year
Health-related quality of life
Time frame: through study completion, an average of 9 months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 2 Apr 2025.
- Derived from this study: PubMed 41308662Linder T, Dressler-Steinbach I, Wegener S, Schellong K, Schmidt S, Eppel D, Monod C, Heinzl F, Redling K, Winzeler B, Mosimann B, Weschenfelder F, Groten T, Mittlbock M, Jendle J, Henrich W, Morettini M, Bozkurt L, Tura A, Gobl C; GRACE study collaborative group. Glycaemic control and pregnancy outcomes with real-time continuous glucose monitoring in gestational diabetes (GRACE): an open-label, multicentre, multinational, randomised controlled trial. Lancet Diabetes Endocrinol. 2026 Jan;14(1):50-61. doi: 10.1016/S2213-8587(25)00288-8. Epub 2025 Nov 24.
- Derived from this study: PubMed 33257486Huhn EA, Linder T, Eppel D, Weisshaupt K, Klapp C, Schellong K, Henrich W, Yerlikaya-Schatten G, Rosicky I, Husslein P, Chalubinski K, Mittlbock M, Rust P, Hoesli I, Winzeler B, Jendle J, Fehm T, Icks A, Vomhof M, Greiner GG, Szendrodi J, Roden M, Tura A, Gobl CS. Effectiveness of real-time continuous glucose monitoring to improve glycaemic control and pregnancy outcome in patients with gestational diabetes mellitus: a study protocol for a randomised controlled trial. BMJ Open. 2020 Nov 30;10(11):e040498. doi: 10.1136/bmjopen-2020-040498.
- Individual participant dataSharing planned: No
Related trials for Cgm
Active, not recruiting
Effect of Probiotics on Insulin Sensitivity in Overweight and Obese Pregnancy
Obesity & Overweight, Gestational Diabetes Mellitus (GDM)
RecruitingObservational study
Food-i-Sense Analytics: Integrating AI Into Continuous Glucose Monitoring Data Analysis for Precision Nutrition.
Prediabetes (Insulin Resistance, Impaired Glucose Tolerance), Artificial Intelligence Mobile Application
Not yet recruiting
Inter-Arm Differences in Continuous Glucose Monitor Readings in Adults With Diabetes
Continuous Glucose Monitoring, Type 1 Diabetes
RecruitingPhase 3
A Study of Orforglipron (LY3502970) Compared With Dulaglutide in Pediatric Participants With Type 2 Diabetes
Diabetes Mellitus, Type 2
Recruiting
Continuous Glucose Monitoring Systems in People With Type 2 Diabetes Not Treated With Insulin
Type 2 Diabetes
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Dexcom G6 Continuous Glucose Monitoring System and self-monitored blood glucose in people with Cgm and Gestational Diabetes, run by Medical University of Vienna at 1 site in Austria.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 2 Apr 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Austria. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
LGA newborns (time frame: postpartum - up to 48 hours after delivery). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03981328, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Apr 2025.