AzTrials
AzTrials

Airway ManagementNCT03976726

Temperature Dependent Changes in I-gel Masks

An observational study of Airway Management, run by Johann Wolfgang Goethe University Hospital at 1 site in Germany.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The i-gel® mask is a second generation, single use supraglottic airway device which does not have an inflatable cuff. The cuff consists of a thermoplastic elastomer and its mechanism of sealing still remains unclear. Read more about this study

Who is it for?
Any age
Conditions the study is for
Airway Management
What is being tested?
Comparison of physcial parameters
Type of treatment
Medical device
How many people
15 participants
Where
1 siteGermany
Study dates
1 Apr 2019to 31 May 2019
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Child, Adult, Older adult

Study population: Masks used in patients (n=5 per size; #3, #4, #5) requiring general anaesthesia for elective surgery without contraindications for i-gel® were collected postoperatively.

Who may be able to join

  • Elective surgery

Who cannot join

  • Contraindications for the use of i-gel masks.
  • Emergency operation
  • non fasted patient

Trial locations and contacts

1 site in 1 country.

Germany1 site
  • University Hospital Frankfurt

    Frankfurt am Main, Hesse, 60590

Other trials in Germany

About this study

Official title: Influence of Temperature on Volume, Weight and Density Changes of I-gel® Masks

The i-gel® mask is a second generation, single use supraglottic airway device which does not have an inflatable cuff. The cuff consists of a thermoplastic elastomer and its mechanism of sealing still remains unclear. Various theories such as temperature-dependent changes in hardness and volume expansion as well as fluid absorption have been discussed.

Read the detailed description

The i-gel® mask (Intersurgical, Workingham, UK), is a second generation, single use supraglottic airway device. In contrast to other devices its' cuff consists of a thermoplastic elastomer (styrene-ethylene-butadine-styrene) instead of an inflatable cuff.

Previous studies have shown, that over time the sealing improved compared to the moment of insertion. The sealing process may be based on various mechanisms. It is assumed, that the warming from room to body temperature leads to an improved adaptation to the patient-specific anatomy due to a softening of the elastomer. By definition, an elastomer is softened by the effect of temperature and become harder when reaching the glass transition temperature.

In this context, Dingley et al. described a change in the degree of hardness as a function of temperature. Prewarmed i-gel® masks (42°C, 30min.) seem to have smaller leak volumes compared to masks stored at room temperature postinsertion in paralyzed patients, but was not reproducible in non-paralyzed patients. Looking at the sealing pressure Chauhan et al. reported that i-gel® masks required a lower pressure compared to masks with an inflatable cuff.

At this point it is not yet clear, whether the thermoplastic cuff material only expands due to an increase in temperature. Liquid absorption and a consecutive expansion is also theoretically conceivable.

Therefore, the aim of the present study is to examine the i-gel® mask within the scope of a benchtop study for temperature-dependent volume expansion and liquid absorption.

Being tested
Comparison of physcial parameters
Keywords
Laryngel Mask

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Comparison of physcial parametersDevice

    Increasement of weight, volume expansion and decrease of density are measured.

Study groups in NCT03976726
Study groupRoleWhat they receive
i-gel size #3Results of benchtop investigations are compared to in patient-used masks. Increasement of weight, volume expansion and decrease of density are measured.
Receives: Device: Comparison of physcial parameters
i-gel size #4Results of benchtop investigations are compared to in patient-used masks. Increasement of weight, volume expansion and decrease of density are measured.
Receives: Device: Comparison of physcial parameters
i-gel size #5Results of benchtop investigations are compared to in patient-used masks. Increasement of weight, volume expansion and decrease of density are measured.
Receives: Device: Comparison of physcial parameters

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Weight

    Changes of masks weight.

    Measured: Two consecutive measurements within 15 minutes once the mask temperature has cooled from body temperature to room temperature.

  2. Volume

    Changes of masks volume.

    Measured: Two consecutive measurements within 15 minutes once the mask temperature has cooled from body temperature to room temperature.

  3. Density

    Changes of masks density.

    Measured: Two consecutive measurements within 15 minutes once the mask temperature has cooled from body temperature to room temperature.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Jun 2019
  2. Study start1 Apr 2019
  3. Primary completion10 May 2019
  4. Study completion31 May 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case-control
Time perspective
Prospective
Enrolment
15 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03976726
Sponsor's protocol ID
05/19
Status last verified
Jun 2019
First submitted
2 Jun 2019
Last updated
6 Jun 2019
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Chauhan G, Nayar P, Seth A, Gupta K, Panwar M, Agrawal N. Comparison of clinical performance of the I-gel with LMA proseal. J Anaesthesiol Clin Pharmacol. 2013 Jan;29(1):56-60. doi: 10.4103/0970-9185.105798.

    PubMed 23493414
  • Gabbott DA, Beringer R. The iGEL supraglottic airway: a potential role for resuscitation? Resuscitation. 2007 Apr;73(1):161-2. doi: 10.1016/j.resuscitation.2006.10.026. Epub 2007 Feb 7. No abstract available.

    PubMed 17289250
  • Jadhav PA, Dalvi NP, Tendolkar BA. I-gel versus laryngeal mask airway-Proseal: Comparison of two supraglottic airway devices in short surgical procedures. J Anaesthesiol Clin Pharmacol. 2015 Apr-Jun;31(2):221-5. doi: 10.4103/0970-9185.155153.

    PubMed 25948905
  • Janakiraman C, Chethan DB, Wilkes AR, Stacey MR, Goodwin N. A randomised crossover trial comparing the i-gel supraglottic airway and classic laryngeal mask airway. Anaesthesia. 2009 Jun;64(6):674-8. doi: 10.1111/j.1365-2044.2009.05898.x.

    PubMed 19453322
  • Russo SG, Cremer S, Eich C, Jipp M, Cohnen J, Strack M, Quintel M, Mohr A. Magnetic resonance imaging study of the in vivo position of the extraglottic airway devices i-gel and LMA-Supreme in anaesthetized human volunteers. Br J Anaesth. 2012 Dec;109(6):996-1004. doi: 10.1093/bja/aes314. Epub 2012 Sep 25.

    PubMed 23015619
  • Theiler LG, Kleine-Brueggeney M, Kaiser D, Urwyler N, Luyet C, Vogt A, Greif R, Unibe MM. Crossover comparison of the laryngeal mask supreme and the i-gel in simulated difficult airway scenario in anesthetized patients. Anesthesiology. 2009 Jul;111(1):55-62. doi: 10.1097/ALN.0b013e3181a4c6b9.

    PubMed 19512881
  • Dingley J, Stephenson J, Allender V, Dawson S, Williams D. Changes in hardness and resilience of i-gelTM cuffs with temperature: a benchtop study. Anaesthesia. 2018 Jul;73(7):856-862. doi: 10.1111/anae.14300. Epub 2018 May 3.

    PubMed 29722434
  • Komasawa N, Nishihara I, Tatsumi S, Minami T. Prewarming of the i-gel facilitates successful insertion and ventilation efficacy with muscle relaxation: a randomized study. J Clin Anesth. 2014 Dec;26(8):663-7. doi: 10.1016/j.jclinane.2014.08.009. Epub 2014 Nov 18.

    PubMed 25468575

Questions about this trial

What is this clinical trial studying?

An observational study of Airway Management, run by Johann Wolfgang Goethe University Hospital at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 6 Jun 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Weight (time frame: Two consecutive measurements within 15 minutes once the mask temperature has cooled from body temperature to room temperature.). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03976726, which also lists 8 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Jun 2019.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in