Integrated Prediction of Extubation Outcome by the Spontaneous Breathing Trial in Newborn Infants
An observational study of Infant, Newborn, Diseases and Airway Morbidity, run by Ourania Kaltsogianni at 1 site in United Kingdom.
Trial summary
Prolonged mechanical ventilation (MV) is associated with significant adverse effects in newborn infants and clinicians aim at its minimum possible duration. Failed extubation and need for reintubation is common and further prolongs the duration of MV. Read more about this study
- Who is it for?
- Any age
- Conditions the study is for
- Infant, Newborn, Diseases, Airway Morbidity
- What is being tested?
- Spontaneous Breathing Trial
- How many people
- 46 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- Feb 2016to Aug 2016
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- All sexes
- No healthy volunteers
- Child, Adult, Older adult
Study population: All infants with a planned extubation during the study period.
Who may be able to join
- All infants with a planned extubation.
Who cannot join
- Infants with known genetic or chromosomal abnormalities.
- Infants with congenital anomalies other than Congenital Diaphragmatic Hernia or Anterior Wall Defect and
- Infants with focal acute lung pathology such as atelectasis or pneumothorax will be excluded from the study.
Trial locations and contacts
1 site in 1 country.
United Kingdom1 site
King's College Hospital NHS Foundation Trust
London, SE5 9RS
About this study
Prolonged mechanical ventilation (MV) is associated with significant adverse effects in newborn infants and clinicians aim at its minimum possible duration. Failed extubation and need for reintubation is common and further prolongs the duration of MV. Hence, accurate prediction of readiness for extubation would incur a considerable reduction in respiratory morbidity.
The Spontaneous breathing Trial (SBT) involves placing the infant on endotracheal continuous positive airway pressure for five minutes with continuous monitoring of heart rate and oxygen saturation levels. The infant would pass the test if there is no hypoxia or bradycardia during the trial. A successful SBT might predict successful extubation.
Read more
The respiratory muscles play a crucial role in successful extubation. One simple way to quantify respiratory muscle function is the rate of relaxation of the inspiratory muscles that can be depicted by the rate of the decline of the airway pressure signal following a spontaneous breath.
The hypothesis of the investigator is that respiratory muscle function assessment using the rate of relaxation of the inspiratory muscles during a SBT can accurately predict extubation outcomes either independently or in conjunction with the outcome of the SBT and the variability of the respiratory parameters during the SBT. This could increase the predicting accuracy of extubation outcomes and thus reduce re-intubation associated respiratory morbidity.
Read the detailed description
Prolonged endotracheal mechanical ventilation has significant adverse effects in newborn infants including subglottic stenosis, bacterial colonisation and bronchopulmonary dysplasia. Neonatal health professionals aim to limit the period of mechanical ventilation to the minimum possible duration. The decision to extubate is commonly a clinical one, based on current ventilator settings, blood gases analysis and the overall clinical condition of the infant. On the other hand, newborn infants commonly fail extubation and require reintubation which is a traumatic invasive procedure which could further prolong the total duration of invasive mechanical ventilation. Thus, accurate prediction of readiness for extubation outcome will probably incur a notable reduction in respiratory morbidity.
A number of studies have evaluated methods to predict extubation outcome. Of them, the spontaneous breathing trial (SBT) has been shown to hold the highest predictive value: it involves placing an infant from invasive mechanical pressure limited time cycled ventilation ventilation to endotracheal continuous positive end-expiratory pressure (ET-CPAP) for a period of 5 minutes during which saturation and heart rate are closely monitored. The infant would pass the test if there is no hypoxia or bradycardia during the test. A successful SBT has a positive predictive value of 93%, sensitivity of 97% and specificity of 73%. The combination of a successful SBT with increased variability in respiratory parameters during the SBT has been reported to further increase the sensitivity of the trial; alas the specificity remains below 75%.
It should be noted that at King's College Hospital the SBT forms part of routine clinical care as per clinical guideline and it is at the discretion of the attending physician to conduct the trial prior to extubation.
The work of breathing is undertaken by the respiratory muscles. Impaired respiratory muscle function is associated with a higher risk of respiratory muscle fatigue and respiratory failure and need for mechanical ventilation. Respiratory muscle function has been identified as an independent predictor of extubation outcome in mechanically ventilated infants. One simple way to quantify respiratory muscle function is the rate of relaxation of the inspiratory muscles which can be depicted by the rate of the decline of the airway pressure signal following a spontaneous breath. In concept, inefficient muscle function is manifested by a more gradual drop to baseline of the airway pressure over time. The principle on which the method is based is that when skeletal muscles contract against increased external loads, their relaxation slows as a result of slower calcium uptake by skeletal muscle fibres. In terms of physical properties, fatigued muscle fibres take longer to relax after contraction and this reduction in the relaxation rate can be quantified by an increase in the time constant of relaxation and a decrease in the maximal relaxation rate.
The rate of relaxation of the inspiratory muscles has been shown to accurately describe respiratory muscle function in non-neonatal populations. The information on the inspiratory muscle rate of relaxation is readily available in the ventilator graphics which, as part of routine clinical care, use a pressure port and a flow sensor to record airway flow, delivered volume and pressure over time. To the knowledge of the investigator, the potential value of this information in predicting extubation outcome in newborn infants has not been explored to date.
Typically, respiratory muscle dysfunction would occur in premature infants owing to immaturity, decreased muscle mass and prematurity-associated co-morbidities. Furthermore infants with Congenital Diaphragmatic Hernia (CDH) and Anterior Wall Defects (AWD) such as gastroschisis and exomphalos, have also been reported to have impaired respiratory muscle function which could probably preclude timely successful extubation. King's College Hospital provides care for a large number of infants with CDH and AWD while also has a long tradition in the assessment of respiratory muscle function in infants making it the ideal site to recruit infants with CDH and AWD.
The hypothesis of the investigator is that respiratory muscle function assessment using the rate of relaxation of the inspiratory muscles during SBT can accurately predict extubation outcome. This prediction might stand independently for the rate of relaxation or in conjunction with SBT-derived respiratory function parameters such as the outcome of the SBT and the variability of respiratory parameters during the SBT. An integrated algorithm incorporating respiratory muscle function data could thus be produced. This would be validated in a large cohort and could increase the prediction accuracy of extubation outcome and thus reduce re-intubation associated respiratory morbidity.
This will be a prospective, observational cohort study. Aims of the study are to measure the rate of relaxation, airway flow, airway pressure, tidal volume and transcutaneous oxygen saturation in all planned extubations over the coming 12 months in the neonatal unit at King's College Hospital. Data to be recorded include basic epidemiologic parameters such as gestation at birth, birth weight, corrected gestational age at measurement, day of life, weight at measurement, blood gas parameters within 6 hours of the SBT and associated co-morbidities that might impact on the success of the SBT such as open ductus arteriosus and current evidence of infection. Infants with known genetic or chromosomal abnormalities, infants with congenital anomalies other than CDH or AWD and infants with focal acute lung pathology such as atelectasis or pneumothorax will be excluded from the study.
Based on the unit's activity over the past two chronological years, the investigators anticipate that with a successful consent rate of 80% it will be possible to measure 100 infants in total: 40 premature infants, 40 term infants and 20 infants with CDH and AWD. As this is a novel index, direct power calculation cannot be undertaken before the commencement of the study. An interim power calculation based on pilot data will be conducted half way through the project at six months, to determine the required sample size. The investigators believe however, that given that previous studies with similar outcome measures incorporated significantly smaller numbers of participants, the achieved sample size will be sufficient for the objectives of the study to be achieved.
Inform written consent will be requested from the parents or legal guardians of the infants and the attending Neonatal Consultant will be requested to assent to the study.
When the clinical team decides an infant is ready for extubation, the investigator will switch the ventilator to ET-CPAP at the same pressure as the positive end expiratory pressure during mechanical ventilation. Airflow, integrated tidal volume and airway pressure will be recorded with the NM3 respiratory function monitor (Philips Respironics, Connecticut, USA). The monitor will be connected to a Laptop (Dell Latitude, Dell, Bracknell, UK) with customised Spectra software (3.0.1.4) (Grove Medical, London, UK). The NM3 respiratory profile monitor has a combined pressure, flow and carbon dioxide sensor and this will be placed in line between the inspiratory limb of the ventilator circuit and the endotracheal tube. The NM3 monitor is automatically calibrated for flow and pressure. Flow will be measured using a fixed orifice pneumotachograph. One of the tubes from the pneumotachograph will be connected to a second pressure transducer to measure airway pressure. Oxygen saturation and heart rate monitoring will also be performed.
A failed SBT will be recorded if the infant has either a bradycardia for more than 15 seconds and/or a fall in SpO2 below 85% despite a 15% increase in FIO2. At this point the study will be stopped and ventilation will be restarted.
Infants will be extubated to either nasal CPAP or high flow nasal cannula oxygen at the clinician's discretion.
The primary study outcome will be reintubation within 72 hours of extubation. The indications for reintubation will be: (a) more than six episodes of apnoea requiring stimulation in six hours, or more than one significant episode of apnoea requiring bag and mask ventilation; (b) respiratory acidosis: PaCO2 >8.5 kPa and pH,7.25; (c)FIO2>0.60 to maintain SpO2 in the range of 90-95%.
If the infant has either bradycardia for more than 15 seconds and/or a fall in SpO2 below 85% despite a 15% increase in FIO2, the study will be stopped and ventilation will be restarted. Strict infection control policies will be followed according to the unit's guidelines.
Data will be stored until the child is 25 years old. Continuous outcomes will be compared between premature and term infants and between term infants and infants with CDH/AWD. Student's t test will be used when the data are normally distributed and Mann-Whitney U test when skewed. Categorical data will be assessed using the Fisher two tailed exact test. P<0.05 will be considered significant. The ability of respiratory variables to accurately discriminate between successful and failed extubation will be assessed using receiver operating characteristic curves. A value of the area under the curve of 0.5 will indicate no discriminatory value, and a value >0.8 will suggest a high predictive value. Standard formulae will be used to calculate sensitivity, specificity, and positive and negative predictive values and likelihood ratios. Statistical analyses will be performed using SPSS software (SPSS Inc, Chicago, Illinois, USA).
The investigators anticipate that by incorporating information on respiratory muscle function during the SBT, it will be possible to create an algorithm that will accurately predict extubation outcome in mechanically ventilated infants. The investigators also want to demonstrate that the rate of respiratory muscle relaxation might be different in premature infants, in full-term infants and in infants with surgically corrected anomalies such as CDH and AWD. These results will be incorporated in local clinical practice and form a guideline on "when to safely extubate" infants on mechanical ventilation. This will reduce respiratory morbidity associated both with prolonged ventilation as well as with failed extubation and re-intubation.
- Conditions
- Infant, Newborn, Diseases, Airway Morbidity
- Being tested
- Spontaneous Breathing Trial
- Medical subject headings
- Infant, Newborn, Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Spontaneous Breathing TrialOther
It involves placing an infant from invasive mechanical pressure limited time cycled ventilation ventilation to endotracheal continuous positive end-expiratory pressure (ET-CPAP) for a period of 5 minutes during which saturation and heart rate are closely monitored. The infant would pass the test if there is no hypoxia or bradycardia during the test. If the infant has either bradycardia for more than 15 seconds and/or a fall in SpO2 below 85% despite a 15% increase in FIO2, the study will be stopped and ventilation will be restarted.
What is being measured
The primary outcome is the main question the study is designed to answer.
Reintubation within 72 hours from extubation
Reintubation will be assessed by reviewing infant's ventilation state
Measured: Through study completion, an average one year
Reintubation within 72 hours from extubation
Reintubation will be assessed by reviewing infant's clinical records
Measured: Through study completion, an average one year
Secondary outcomes (2)
Comparison of the rate of relaxation of respiratory muscles between premature infants that fail extubation and premature infants that successfully wean off mechanical ventilation.
Calculation of the time constant of relaxation that is the reciprocal of the slope of the decline in pressure as a function of time during the spontaneous breathing trial.
Measured: Through study completion, an average one year
Comparison of the rate of relaxation of respiratory muscles between premature infants and term infants.
Calculation of the time constant of relaxation that is the reciprocal of the slope of the decline in pressure as a function of time during the spontaneous breathing trial.
Measured: Through study completion, an average one year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted20 May 2019
- Study startFeb 2016
- Primary completionAug 2016
- Study completionAug 2016
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (12)Papers the sponsor has linked to this study.
- Other trials for Infant, Newborn, DiseasesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 46 participants (actual)
Sponsor and investigators
- Lead sponsor
- Ourania Kaltsogianni
- Sponsor type
- University, hospital or other
- Collaborators
- King's College London
- Responsible party
- Sponsor-investigator, Ourania Kaltsogianni, King's College Hospital NHS Trust
- Investigators
- Theodore Dassios, Consultant, Principal investigator, King's College Hospital NHS Trust
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03956511
- Sponsor's protocol ID
- 193377
- Status last verified
- May 2019
- First submitted
- 30 Aug 2016
- Last updated
- 20 May 2019
- Results posted
- No
- Data monitoring committee
- Yes
- Individual data sharing
- No
Publications
Kamlin CO, Davis PG, Morley CJ. Predicting successful extubation of very low birthweight infants. Arch Dis Child Fetal Neonatal Ed. 2006 May;91(3):F180-3. doi: 10.1136/adc.2005.081083. Epub 2006 Jan 12.
PubMed 16410255Stefanescu BM, Murphy WP, Hansell BJ, Fuloria M, Morgan TM, Aschner JL. A randomized, controlled trial comparing two different continuous positive airway pressure systems for the successful extubation of extremely low birth weight infants. Pediatrics. 2003 Nov;112(5):1031-8. doi: 10.1542/peds.112.5.1031.
PubMed 14595042Currie A, Patel DS, Rafferty GF, Greenough A. Prediction of extubation outcome in infants using the tension time index. Arch Dis Child Fetal Neonatal Ed. 2011 Jul;96(4):F265-9. doi: 10.1136/adc.2010.191015. Epub 2010 Nov 20.
PubMed 21097837Dimitriou G, Fouzas S, Vervenioti A, Tzifas S, Mantagos S. Prediction of extubation outcome in preterm infants by composite extubation indices. Pediatr Crit Care Med. 2011 Nov;12(6):e242-9. doi: 10.1097/PCC.0b013e3181fe3431.
PubMed 21037500Kavvadia V, Greenough A, Dimitriou G. Prediction of extubation failure in preterm neonates. Eur J Pediatr. 2000 Apr;159(4):227-31. doi: 10.1007/s004310050059.
PubMed 10789923Mikhno A, Ennett CM. Prediction of extubation failure for neonates with respiratory distress syndrome using the MIMIC-II clinical database. Annu Int Conf IEEE Eng Med Biol Soc. 2012;2012:5094-7. doi: 10.1109/EMBC.2012.6347139.
PubMed 23367074Kaczmarek J, Kamlin CO, Morley CJ, Davis PG, Sant'anna GM. Variability of respiratory parameters and extubation readiness in ventilated neonates. Arch Dis Child Fetal Neonatal Ed. 2013 Jan;98(1):F70-3. doi: 10.1136/fetalneonatal-2011-301340. Epub 2012 May 3.
PubMed 22556206Kyroussis D, Mills G, Hamnegard CH, Wragg S, Road J, Green M, Moxham J. Inspiratory muscle relaxation rate assessed from sniff nasal pressure. Thorax. 1994 Nov;49(11):1127-33. doi: 10.1136/thx.49.11.1127.
PubMed 7831629American Thoracic Society/European Respiratory Society. ATS/ERS Statement on respiratory muscle testing. Am J Respir Crit Care Med. 2002 Aug 15;166(4):518-624. doi: 10.1164/rccm.166.4.518. No abstract available.
PubMed 12186831Dassios T, Kaditis A, Katelari A, Chrousos G, Doudounakis S, Dimitriou G. Time constant of inspiratory muscle relaxation in cystic fibrosis. Pediatr Res. 2015 Apr;77(4):541-5. doi: 10.1038/pr.2015.2. Epub 2015 Feb 2.
PubMed 25642662Kyroussis D, Johnson LC, Hamnegard CH, Polkey MI, Moxham J. Inspiratory muscle maximum relaxation rate measured from submaximal sniff nasal pressure in patients with severe COPD. Thorax. 2002 Mar;57(3):254-7. doi: 10.1136/thorax.57.3.254.
PubMed 11867831Kassim Z, Moxham J, Davenport M, Nicolaides K, Greenough A, Rafferty GF. Respiratory muscle strength in healthy infants and those with surgically correctable anomalies. Pediatr Pulmonol. 2015 Jan;50(1):71-8. doi: 10.1002/ppul.23007. Epub 2014 Feb 20.
PubMed 24574153
Study at a glance
From the registry record, last updated by the sponsor on 20 May 2019. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Integrated Prediction of Extubation Outcome by the Spontaneous Breathing Trial in Newborn Infants
- ClinicalTrials.gov ID
- NCT03956511
- Acronym / sponsor ID
- 193377
- Conditions
- Infant, Newborn, Diseases, Airway Morbidity
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 46 participants (actual)
- Lead sponsor
- Ourania KaltsogianniUniversity, hospital or other
- Collaborators
- King's College London
- Study start
- Feb 2016 (actual)
- Primary completion
- Aug 2016 (actual)
- Study completion
- Aug 2016 (actual)
- First posted
- 20 May 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Prolonged mechanical ventilation (MV) is associated with significant adverse effects in newborn infants and clinicians aim at its minimum possible duration. Failed extubation and need for reintubation is common and further prolongs the duration of MV. Hence, accurate prediction of readiness for extubation would incur a considerable reduction in respiratory morbidity.
The Spontaneous breathing Trial (SBT) involves placing the infant on endotracheal continuous positive airway pressure for five minutes with continuous monitoring of heart rate and oxygen saturation levels. The infant would pass the test if there is no hypoxia or bradycardia during the trial. A successful SBT might predict successful extubation.
The respiratory muscles play a crucial role in successful extubation. One simple way to quantify respiratory muscle function is the rate of relaxation of the inspiratory muscles that can be depicted by the rate of the decline of the airway pressure signal following a spontaneous breath.
The hypothesis of the investigator is that respiratory muscle function assessment using the rate of relaxation of the inspiratory muscles during a SBT can accurately predict extubation outcomes either independently or in conjunction with the outcome of the SBT and the variability of the respiratory parameters during the SBT. This could increase the predicting accuracy of extubation outcomes and thus reduce re-intubation associated respiratory morbidity.
Detailed description
Prolonged endotracheal mechanical ventilation has significant adverse effects in newborn infants including subglottic stenosis, bacterial colonisation and bronchopulmonary dysplasia. Neonatal health professionals aim to limit the period of mechanical ventilation to the minimum possible duration. The decision to extubate is commonly a clinical one, based on current ventilator settings, blood gases analysis and the overall clinical condition of the infant. On the other hand, newborn infants commonly fail extubation and require reintubation which is a traumatic invasive procedure which could further prolong the total duration of invasive mechanical ventilation. Thus, accurate prediction of readiness for extubation outcome will probably incur a notable reduction in respiratory morbidity.
A number of studies have evaluated methods to predict extubation outcome. Of them, the spontaneous breathing trial (SBT) has been shown to hold the highest predictive value: it involves placing an infant from invasive mechanical pressure limited time cycled ventilation ventilation to endotracheal continuous positive end-expiratory pressure (ET-CPAP) for a period of 5 minutes during which saturation and heart rate are closely monitored. The infant would pass the test if there is no hypoxia or bradycardia during the test. A successful SBT has a positive predictive value of 93%, sensitivity of 97% and specificity of 73%. The combination of a successful SBT with increased variability in respiratory parameters during the SBT has been reported to further increase the sensitivity of the trial; alas the specificity remains below 75%.
It should be noted that at King's College Hospital the SBT forms part of routine clinical care as per clinical guideline and it is at the discretion of the attending physician to conduct the trial prior to extubation.
The work of breathing is undertaken by the respiratory muscles. Impaired respiratory muscle function is associated with a higher risk of respiratory muscle fatigue and respiratory failure and need for mechanical ventilation. Respiratory muscle function has been identified as an independent predictor of extubation outcome in mechanically ventilated infants. One simple way to quantify respiratory muscle function is the rate of relaxation of the inspiratory muscles which can be depicted by the rate of the decline of the airway pressure signal following a spontaneous breath. In concept, inefficient muscle function is manifested by a more gradual drop to baseline of the airway pressure over time. The principle on which the method is based is that when skeletal muscles contract against increased external loads, their relaxation slows as a result of slower calcium uptake by skeletal muscle fibres. In terms of physical properties, fatigued muscle fibres take longer to relax after contraction and this reduction in the relaxation rate can be quantified by an increase in the time constant of relaxation and a decrease in the maximal relaxation rate.
The rate of relaxation of the inspiratory muscles has been shown to accurately describe respiratory muscle function in non-neonatal populations. The information on the inspiratory muscle rate of relaxation is readily available in the ventilator graphics which, as part of routine clinical care, use a pressure port and a flow sensor to record airway flow, delivered volume and pressure over time. To the knowledge of the investigator, the potential value of this information in predicting extubation outcome in newborn infants has not been explored to date.
Typically, respiratory muscle dysfunction would occur in premature infants owing to immaturity, decreased muscle mass and prematurity-associated co-morbidities. Furthermore infants with Congenital Diaphragmatic Hernia (CDH) and Anterior Wall Defects (AWD) such as gastroschisis and exomphalos, have also been reported to have impaired respiratory muscle function which could probably preclude timely successful extubation. King's College Hospital provides care for a large number of infants with CDH and AWD while also has a long tradition in the assessment of respiratory muscle function in infants making it the ideal site to recruit infants with CDH and AWD.
The hypothesis of the investigator is that respiratory muscle function assessment using the rate of relaxation of the inspiratory muscles during SBT can accurately predict extubation outcome. This prediction might stand independently for the rate of relaxation or in conjunction with SBT-derived respiratory function parameters such as the outcome of the SBT and the variability of respiratory parameters during the SBT. An integrated algorithm incorporating respiratory muscle function data could thus be produced. This would be validated in a large cohort and could increase the prediction accuracy of extubation outcome and thus reduce re-intubation associated respiratory morbidity.
This will be a prospective, observational cohort study. Aims of the study are to measure the rate of relaxation, airway flow, airway pressure, tidal volume and transcutaneous oxygen saturation in all planned extubations over the coming 12 months in the neonatal unit at King's College Hospital. Data to be recorded include basic epidemiologic parameters such as gestation at birth, birth weight, corrected gestational age at measurement, day of life, weight at measurement, blood gas parameters within 6 hours of the SBT and associated co-morbidities that might impact on the success of the SBT such as open ductus arteriosus and current evidence of infection. Infants with known genetic or chromosomal abnormalities, infants with congenital anomalies other than CDH or AWD and infants with focal acute lung pathology such as atelectasis or pneumothorax will be excluded from the study.
Based on the unit's activity over the past two chronological years, the investigators anticipate that with a successful consent rate of 80% it will be possible to measure 100 infants in total: 40 premature infants, 40 term infants and 20 infants with CDH and AWD. As this is a novel index, direct power calculation cannot be undertaken before the commencement of the study. An interim power calculation based on pilot data will be conducted half way through the project at six months, to determine the required sample size. The investigators believe however, that given that previous studies with similar outcome measures incorporated significantly smaller numbers of participants, the achieved sample size will be sufficient for the objectives of the study to be achieved.
Inform written consent will be requested from the parents or legal guardians of the infants and the attending Neonatal Consultant will be requested to assent to the study.
When the clinical team decides an infant is ready for extubation, the investigator will switch the ventilator to ET-CPAP at the same pressure as the positive end expiratory pressure during mechanical ventilation. Airflow, integrated tidal volume and airway pressure will be recorded with the NM3 respiratory function monitor (Philips Respironics, Connecticut, USA). The monitor will be connected to a Laptop (Dell Latitude, Dell, Bracknell, UK) with customised Spectra software (3.0.1.4) (Grove Medical, London, UK). The NM3 respiratory profile monitor has a combined pressure, flow and carbon dioxide sensor and this will be placed in line between the inspiratory limb of the ventilator circuit and the endotracheal tube. The NM3 monitor is automatically calibrated for flow and pressure. Flow will be measured using a fixed orifice pneumotachograph. One of the tubes from the pneumotachograph will be connected to a second pressure transducer to measure airway pressure. Oxygen saturation and heart rate monitoring will also be performed.
A failed SBT will be recorded if the infant has either a bradycardia for more than 15 seconds and/or a fall in SpO2 below 85% despite a 15% increase in FIO2. At this point the study will be stopped and ventilation will be restarted.
Infants will be extubated to either nasal CPAP or high flow nasal cannula oxygen at the clinician's discretion.
The primary study outcome will be reintubation within 72 hours of extubation. The indications for reintubation will be: (a) more than six episodes of apnoea requiring stimulation in six hours, or more than one significant episode of apnoea requiring bag and mask ventilation; (b) respiratory acidosis: PaCO2 >8.5 kPa and pH,7.25; (c)FIO2>0.60 to maintain SpO2 in the range of 90-95%.
If the infant has either bradycardia for more than 15 seconds and/or a fall in SpO2 below 85% despite a 15% increase in FIO2, the study will be stopped and ventilation will be restarted. Strict infection control policies will be followed according to the unit's guidelines.
Data will be stored until the child is 25 years old. Continuous outcomes will be compared between premature and term infants and between term infants and infants with CDH/AWD. Student's t test will be used when the data are normally distributed and Mann-Whitney U test when skewed. Categorical data will be assessed using the Fisher two tailed exact test. P<0.05 will be considered significant. The ability of respiratory variables to accurately discriminate between successful and failed extubation will be assessed using receiver operating characteristic curves. A value of the area under the curve of 0.5 will indicate no discriminatory value, and a value >0.8 will suggest a high predictive value. Standard formulae will be used to calculate sensitivity, specificity, and positive and negative predictive values and likelihood ratios. Statistical analyses will be performed using SPSS software (SPSS Inc, Chicago, Illinois, USA).
The investigators anticipate that by incorporating information on respiratory muscle function during the SBT, it will be possible to create an algorithm that will accurately predict extubation outcome in mechanically ventilated infants. The investigators also want to demonstrate that the rate of respiratory muscle relaxation might be different in premature infants, in full-term infants and in infants with surgically corrected anomalies such as CDH and AWD. These results will be incorporated in local clinical practice and form a guideline on "when to safely extubate" infants on mechanical ventilation. This will reduce respiratory morbidity associated both with prolonged ventilation as well as with failed extubation and re-intubation.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
Who may qualify
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
- Study population
- All infants with a planned extubation during the study period.
Key inclusion criteria (1 listed)
- All infants with a planned extubation.
Key exclusion criteria (3 listed)
- Infants with known genetic or chromosomal abnormalities.
- Infants with congenital anomalies other than Congenital Diaphragmatic Hernia or Anterior Wall Defect and
- Infants with focal acute lung pathology such as atelectasis or pneumothorax will be excluded from the study.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Spontaneous Breathing TrialIt involves placing an infant from invasive mechanical pressure limited time cycled ventilation ventilation to endotracheal continuous positive end-expiratory pressure (ET-CPAP) for a period of 5 minutes during which saturation and heart rate are closely monitored. The infant would pass the test if there is no hypoxia or bradycardia during the test. If the infant has either bradycardia for more than 15 seconds and/or a fall in SpO2 below 85% despite a 15% increase in FIO2, the study will be stopped and ventilation will be restarted. | Other | – |
Primary outcome
Reintubation within 72 hours from extubation
Time frame: Through study completion, an average one year
Reintubation will be assessed by reviewing infant's ventilation state
Reintubation within 72 hours from extubation
Time frame: Through study completion, an average one year
Reintubation will be assessed by reviewing infant's clinical records
2 secondary outcomes
Comparison of the rate of relaxation of respiratory muscles between premature infants that fail extubation and premature infants that successfully wean off mechanical ventilation.
Time frame: Through study completion, an average one year
Comparison of the rate of relaxation of respiratory muscles between premature infants and term infants.
Time frame: Through study completion, an average one year
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 20 May 2019.
- Background: PubMed 16410255Kamlin CO, Davis PG, Morley CJ. Predicting successful extubation of very low birthweight infants. Arch Dis Child Fetal Neonatal Ed. 2006 May;91(3):F180-3. doi: 10.1136/adc.2005.081083. Epub 2006 Jan 12.
- Background: PubMed 14595042Stefanescu BM, Murphy WP, Hansell BJ, Fuloria M, Morgan TM, Aschner JL. A randomized, controlled trial comparing two different continuous positive airway pressure systems for the successful extubation of extremely low birth weight infants. Pediatrics. 2003 Nov;112(5):1031-8. doi: 10.1542/peds.112.5.1031.
- Background: PubMed 21097837Currie A, Patel DS, Rafferty GF, Greenough A. Prediction of extubation outcome in infants using the tension time index. Arch Dis Child Fetal Neonatal Ed. 2011 Jul;96(4):F265-9. doi: 10.1136/adc.2010.191015. Epub 2010 Nov 20.
- Background: PubMed 21037500Dimitriou G, Fouzas S, Vervenioti A, Tzifas S, Mantagos S. Prediction of extubation outcome in preterm infants by composite extubation indices. Pediatr Crit Care Med. 2011 Nov;12(6):e242-9. doi: 10.1097/PCC.0b013e3181fe3431.
- Background: PubMed 10789923Kavvadia V, Greenough A, Dimitriou G. Prediction of extubation failure in preterm neonates. Eur J Pediatr. 2000 Apr;159(4):227-31. doi: 10.1007/s004310050059.
- Background: PubMed 23367074Mikhno A, Ennett CM. Prediction of extubation failure for neonates with respiratory distress syndrome using the MIMIC-II clinical database. Annu Int Conf IEEE Eng Med Biol Soc. 2012;2012:5094-7. doi: 10.1109/EMBC.2012.6347139.
- Background: PubMed 22556206Kaczmarek J, Kamlin CO, Morley CJ, Davis PG, Sant'anna GM. Variability of respiratory parameters and extubation readiness in ventilated neonates. Arch Dis Child Fetal Neonatal Ed. 2013 Jan;98(1):F70-3. doi: 10.1136/fetalneonatal-2011-301340. Epub 2012 May 3.
- Background: PubMed 7831629Kyroussis D, Mills G, Hamnegard CH, Wragg S, Road J, Green M, Moxham J. Inspiratory muscle relaxation rate assessed from sniff nasal pressure. Thorax. 1994 Nov;49(11):1127-33. doi: 10.1136/thx.49.11.1127.
- Background: PubMed 12186831American Thoracic Society/European Respiratory Society. ATS/ERS Statement on respiratory muscle testing. Am J Respir Crit Care Med. 2002 Aug 15;166(4):518-624. doi: 10.1164/rccm.166.4.518. No abstract available.
- Background: PubMed 25642662Dassios T, Kaditis A, Katelari A, Chrousos G, Doudounakis S, Dimitriou G. Time constant of inspiratory muscle relaxation in cystic fibrosis. Pediatr Res. 2015 Apr;77(4):541-5. doi: 10.1038/pr.2015.2. Epub 2015 Feb 2.
- Background: PubMed 11867831Kyroussis D, Johnson LC, Hamnegard CH, Polkey MI, Moxham J. Inspiratory muscle maximum relaxation rate measured from submaximal sniff nasal pressure in patients with severe COPD. Thorax. 2002 Mar;57(3):254-7. doi: 10.1136/thorax.57.3.254.
- Background: PubMed 24574153Kassim Z, Moxham J, Davenport M, Nicolaides K, Greenough A, Rafferty GF. Respiratory muscle strength in healthy infants and those with surgically correctable anomalies. Pediatr Pulmonol. 2015 Jan;50(1):71-8. doi: 10.1002/ppul.23007. Epub 2014 Feb 20.
- Individual participant dataSharing planned: No
Related trials for Infant, Newborn, Diseases
Active, not recruitingPhase 1/2
Selumetinib in Treating Young Patients With Recurrent or Refractory Low Grade Glioma
Low Grade Glioma, Recurrent Childhood Pilocytic Astrocytoma
Not yet recruitingPhase 1
A Phase I Study of GLR2053 Tablets in Chinese Healthy Adult Participants
Atopic Dermatitis
Not yet recruitingPhase 2/3
A Pivotal Safety and Immunogenicity GBS-NN/NN2 Vaccine Maternal Immunisation Trial
Streptococcus Agalactiae Infection, Neonatal Sepsis
RecruitingPhase 1
Serial Amnioinfusions as Regenerative Therapy for Pulmonary Hypoplasia
Renal Failure Congenital, Congenital Renal Anomaly Nos
RecruitingPhase 1/2
A First-in-human Study of KK8123 in Adults With X-linked Hypophosphatemia
X-linked Hypophosphatemia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Theodore Dassios, Consultant principal investigator
King's College Hospital NHS Trust
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Infant, Newborn, Diseases and Airway Morbidity, run by Ourania Kaltsogianni at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 20 May 2019. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Reintubation within 72 hours from extubation (time frame: Through study completion, an average one year). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03956511, which also lists 12 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 May 2019.