Pectus excavatum (PE) is the most common anterior chest wall deformity. Currently, a chest radiography (CR) or Computed Tomography (CT) scan is acquired to determine and objectify pectus severity using the Haller Index. Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
Conditions the study is for
Pectus Excavatum
What is being tested?
3D optical surface image, Chest radiography and CT scan
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
28 participants
Where
1 siteNetherlands
Study dates
21 Aug 2019to Mar 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • All patients that visit the Zuyderland Medical Centre outpatient clinic for evaluation of their pectus excavatum.
  • No age restrictions were imposed, however, to be eligible, it was mandatory to be able to stand still in and upright position for 60 seconds.

Who cannot join

  • Patients that suffer from any form of light hypersensitivity or epilepsy were not considered while 3D optical surface images were acquired with the use of structured, flashing light.

Trial locations and contacts

1 site in 1 country.

Netherlands1 site, 1 recruiting
  • Zuyderland Medical Centre

    Heerlen, Limburg, 6419PC

    Jean Daemen, +314597777, j.daemen@zuyderland.nl

    Recruiting

Other trials in Netherlands

About this study

Official title: Three-dimensional Optical Surface Imaging as a Diagnostic Tool for Severity Quantification and Clinical Decision Making in Pectus Excavatum

Pectus excavatum (PE) is the most common anterior chest wall deformity. Currently, a chest radiography (CR) or Computed Tomography (CT) scan is acquired to determine and objectify pectus severity using the Haller Index. Alongside other determinants, the Haller Index value is used in the proces of clinical decision making and determine surgical candidacy. However, cross-sectional imaging based calculation of the Haller Index implies exposure to ionizing radiation that should be limited at all times to diminish the cumulative long-term risks of malignancy. Especially in pectus patients that often concerns children.

Three-dimensional (3D) optical surface imaging offers a non-invasive, radiation-free alternative that may be used to obtain thoracic measures and determine pectus severity. However, for 3D images/scans to be used as a diagnostic tool in the proces of clinical decision making and determine surgical candidacy, its diagnostic accuracy should be evaluated. This will be investigated utilizing a pilot study design as no prior accuracy studies are available.

Read the detailed description

This single-centre prospective pilot study is conducted to assess the diagnostic accuracy of 3D optical surface imaging based external Haller Index (EHI) measurements to quantify the severity of pectus excavatum. CR and CT based conventional Haller Indices (HI) are used as reference method.

CR and CT are both used as reference method, as the work-up of pectus patients in our centre is dependent of age. Subsequently, two groups are created: (A) patients under 18 years of age that receive a frontal (anteroposterior) and sagittal chest radiography, and (B) patients aged 18 years or older that receive a chest CT scan.

In this study, patients are their own control. To obtain optical surface images, a handheld 3D scanner is used. During acquisition, subjects will be standing in an upright position with arms abducted. Standard routinely used protocols are used to acquire chest radiographies and CT scans.

The HI is obtained from all chest radiographies and CT scans, calculated by dividing the widest thoracic transverse diameter by the anteroposterior distance, measured from the posterior surface of sternum to the anterior surface of the vertebral body. The EHI, a modified measurement to assess pectus deformity, is used to quantify PE severity based on 3D optical surface images. The EHI is calculated by dividing the widest external thoracic transverse diameter by the distance between the external deepest point or point of maximal protrusion and external vertebral body. The EHI is also calculated from the available chest radiographies and CT scans.

All measurements will be performed by three blinded observers that are not responsible to perform a comprehensive interpretation of the study. Following acquisition of all indices, the inter-observer reliability is calculated using the intraclass correlation coefficient. Based on the means, a receiver-operating characteristic (ROC)-curve is created for the 3D scan based EHI measurements, utilizing the surgical indication based on CR and CT (HI larger or equal to 3.25) images as gold standard. The optimal cut-off value, obtained from the ROC-curve is subsequently used to determine the 3D optical surface images' diagnostic accuracy.

Being tested
3D optical surface image, Chest radiography, CT scan
Keywords
Haller Index, Optical Imaging, Torso Topography, Three-dimensional Surface Scan, Diagnostic accuracy
Medical subject headings
Funnel Chest

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • 3D optical surface imageOther

    3D optical surface images will be acquired and used to calculate the EHI

  • Chest radiographyRadiation

    Chest radiographies will be acquired and used to calculated the HI and EHI

  • CT scanRadiation

    CT scans will be acquired and used to calculate the HI and EHI

Study groups in NCT03926078
Study groupRoleWhat they receive
Patients under 18 years of ageOtherGroup A consists of patients that receive a chest radiography in the current work-up of PE.
Receives: Other: 3D optical surface image; Radiation: Chest radiography
Patients aged 18 years or olderOtherGroup B consists of patients that receive a CT scan in the current work-up of PE.
Receives: Other: 3D optical surface image; Radiation: CT scan

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Diagnostic accuracy of the EHI, calculated from 3D optical surface images

    Dependent of age, the CR or CT based HI is utilized as reference method

    Measured: 1 year

Secondary outcomes (5)
  1. Inter-observer reliability

    Inter-observer reliability of CR, CT and 3D image derived (external) Haller Inidices, obtained by 3 observers

    Measured: 1 year

  2. Correlation of CT scan derived HI and EHI

    Correlation is assessed by the Pearson's correlation coefficient

    Measured: 1 year

  3. Correlation of CT scan derived EHI and 3D optical surface image derived EHI

    Correlation is assessed by the Pearson's correlation coefficient

    Measured: 1 year

  4. Correlation of CT and CR derived HI with 3D optical surface image derived EHI

    Correlation is assessed by the Pearson's correlation coefficient

    Measured: 1 year

  5. Absolute agreement of CT scan derived EHI and 3D optical surface image derived EHI

    Assessed by the intraclass correlation coefficient

    Measured: 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Apr 2019
  2. Study start21 Aug 2019
  3. Primary completionFeb 2021 (estimated)
  4. Study completionMar 2021 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Non-randomised
Intervention model
Single group
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
28 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03926078
Sponsor's protocol ID
METCZ20190048
Acronym
3D PECTUS
Status last verified
Jul 2020
First submitted
18 Apr 2019
Last updated
2 Jul 2020
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing 3D optical surface image, Chest radiography and CT scan in people with Pectus Excavatum, run by Zuyderland Medisch Centrum at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 2 Jul 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Jean Daemen (+31884597777, j.daemen@zuyderland.nl), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Diagnostic accuracy of the EHI, calculated from 3D optical surface images (time frame: 1 year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Jul 2020.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in