Jaw, EdentulousNCT03862482

Peri-Implant Healing Around Two Different Machined-Collar Designs After 25 Years of Function

A study testing Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1), Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2) and Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3) in people with Jaw, Edentulous, run by Université de Montréal at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Brånemark System® dental implant osseointegration was introduced in 1965 as a novel approach to the replacement of missing teeth. Although this implant's machined, screw-shaped surface had excellent, well-documented, short- and long-term clinical success (Adell, R. Read more about this study

Who is it for?
Ages 48 to 82 yearsHealthy volunteers can take part
Conditions the study is for
Jaw, Edentulous
What is being tested?
Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1), Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2) and Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
22 participants
Where
1 siteCanada
Study dates
3 Jun 2019to 31 Dec 2019
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 48 to 82 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • non-smoker
  • no temporomandibular joint (TMJ) disorder or facial pain
  • having participated in the original study (1993 - 1996) at which time the minimum participants' age was 25 years and the maximum 56 years

Who cannot join

  • refusal to sign informed consent documents

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • Université de Montréal

    Montreal, Quebec, H3C 3J7

Other trials in Canada

About this study

Official title: Prospective Randomised Clinical Trial Evaluating the Effects of Two Different Implant Collar Designs on Peri-Implant Healing and Functional Osseointegration After 25 Years of Function With Full Arch Mandibular Prostheses

Brånemark System® dental implant osseointegration was introduced in 1965 as a novel approach to the replacement of missing teeth. Although this implant's machined, screw-shaped surface had excellent, well-documented, short- and long-term clinical success (Adell, R. 1987; Albrektsson, T., et al., 1981; Albrektsson, T., et al., 1986; Brånemark, P-I. , 1983; Brånemark P-I. 1987), newer implant designs were introduced that could enhance fusion of the implant to jaw bones, and better resist functional forces. One such implant, Screw-Vent®, has a fixture macro structure very similar to that of the Brånemark® implant. However, its fixture surface was acid etched (1-3µm) which could enhance osseointegration, and it has a longer, narrower machined internal-hex, friction-fit collar that could better resist functional forces.These characteristics should lead to less bone loss (Niznick, G. A., 1989). However, one clinical study (De Bruyen, et al., 1992) reported greater short-term bone loss with this implant compared to the Brånemark® implant, possibly due to its longer machined collar, and advocated long-term clinical studies. Therefore, this prospective within-subject clinical trial was undertaken in 1993 to first compare the Brånemark® implant with another implant, Swede-Vent®, a copy of the Brånemark® macro structure except for its fixture surface that was identically micro textured as that of Screw-Vent® by the same manufacturer. The effect on bone healing could then be compared between Brånemark®'s machined and Swede-Vent®'s micro textured fixture surfaces in the short- and long-terms. Since Screw-Vent®'s fixture surface was identically micro textured as that of Swede-Vent®, the investigators could then evaluate and compare the effects on bone healing of Screw-Vent®'s longer, narrower, internal-connection machined collar to the identical shorter, wider, external-connection machined collars of the Swede-Vent® and Brånemark® implants. All three two-part, platform-matched, parallel-wall implants were made of commercially pure titanium, had a very similar fixture macro design, were approved by the Food and Drug Administration (USA) and Health and Welfare Canada, and were commercially available in North America. Brånemark® and Screw-Vent® implants are still available, but the Swede-Vent® implant is not.

Read the detailed description

Therefore, between 1993 and 1996, 58 of 60 eligible participants had been recruited into a prospective, randomized clinical trial. This trial had been peer reviewed, had received ethical approval, and had taken place at the Université de Montréal's Faculty of Dental Medicine and its affiliated hospital dental department. Follow-up documentation occurred at one year, two years, and 15 to 20 years following prostheses attachment (ClinicalTrials Identification Number NCT01641198), and the results were published (Camarda, et al., 2018). The present study reports on data collected at the 25-year (24.6 ± 0.19 years, mean ± SE) follow-up (ClinicalTrials Identification Number NCT03862482), focusing specifically on the evaluation and comparison of the effects on peri-implant healing and functional osseointegration of the two different machined collar designs. That is to say, the identical shorter, wider, external-connection Brånemark® and Swede-Vent® collars versus the longer, narrower, internal-connection Screw-Vent® collar. Twenty-two of the original participants (41.5%, age 71.1 ± 1.2 years, 11 women, 110 implants) were enrolled into this study. All study procedures were performed in accordance with the Helsinki Declaration and its later amendments, and all participants signed informed consent documents prior to inclusion into this study.

Conditions
Jaw, Edentulous
Being tested
Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1), Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2), Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)
Keywords
Dental Implants, Microtextured Fixture, Machined Collar
Medical subject headings
Jaw, Edentulous

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1)Device

    Brånemark® implant placed at sites 2 (left medial) and 5 (right distal), Swede-Vent® implant placed at sites 1 (left distal) and 4 (right medial), Screw-Vent® implant placed at site 3 (para symphysis)

  • Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2)Device

    Brånemark® implant placed at site 3 (para symphysis), Swede-Vent® implant placed at sites 2 (left medial) and 5 (right distal), Screw-Vent® implant placed at sites 1 (left distal) and 4 (right medial)

  • Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)Device

    Brånemark® implant placed at sites 1 (left distal) and 4 (right medial), Swede-Vent® implant placed at site 3 (para symphysis), Screw-Vent® implant placed at sites 2 (left medial) and 5 (right distal)

Study groups in NCT03862482
Study groupRoleWhat they receive
Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1)Active comparatorDevice placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at one site
Receives: Device: Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1)
Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2)ExperimentalDevice placement: B (Brånemark® dental implant) placed at one site, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at two sites
Receives: Device: Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2)
Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)ExperimentalDevice placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at one site, SC (Screw-Vent® dental implant) placed at two sites
Receives: Device: Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Comparison of Distance Between First Bone to Implant Contact Point (fBIC) and Microgap (MG), After 25 Years of Function, Between All B, All SW, and All SC Dental Implant Units in All Three Configurations

    Distance between first bone-to-implant contact point (fBIC) and microgap (MG) at the crest was measured (mm) at mesial and distal sides of each implant/abutment complex on conventional peri-apical radiographs using a standardized equipment and measurement protocol (Camarda, et al., 2018) after 25 years of function. Values fBIC-MG (Mean ± SE) ("-" for bone loss) were calculated, recorded and compared between all B and all SW, between all B and all SC and between all SW and all SC dental implant units in all three Configurations

    Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function

Secondary outcomes (5)
  1. Comparison of Prosthesis, Abutment, and Implant Mobility or Looseness: Absence (0) or Presence (1) of Mobility or Looseness After 25 Years of Function

    Mobility was measured by applying manual pressure on the handles of two instruments, each placed on opposite sides of the prostheses and abutments, and was recorded as 0 (no mobility or looseness) or 1 (mobility or looseness). Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)

    Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function

  2. Comparison of Soft Tissue Healing: Height (mm) of Keratinized Tissue After 25 Years of Function

    Height of the keratinized tissue was measured (mm) using a ColorVue UNC12 Hu-Friedy probe on the buccal and lingual implant/abutment surfaces. Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)

    Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function

  3. Comparison of Soft Tissue Healing: Probing Depth (mm) After 25 Years of Function

    Using a ColorVue UNC12 Hu-Friedy probe, probing depth was measured (mm) on the buccal, lingual, mesial and distal implant/abutment surfaces. Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1(Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent ®1, Screw-Vent® 2)

    Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function

  4. Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Plaque and/or Gingival Bleeding After 25 Years of Function

    Absence (0) or presence (1) of plaque and/or gingival bleeding on probing was evaluated using the dichotomous/binary plaque index (dPI) (Galgut, P. A., 1999) and bleeding index (dBI), respectively (Galgut, P.A., 1999). Values (Mean ± SE) were compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent ®1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)

    Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function

  5. Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Purulent Exudate After 25 Years of Function

    Absence (0) or presence (1) of purulent exudate on probing was evaluated. Values (Mean ± SE) were recorded, and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)

    Measured: After 25 years (24.6 ± 0.19 years, mean ± SE) of function

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Mar 2019
  2. Study start3 Jun 2019
  3. Primary completion16 Aug 2019
  4. Study completion31 Dec 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Triple blind
Who is masked
Participant, Care provider, Investigator
Enrolment
22 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03862482
Sponsor's protocol ID
CERC-19-015-P
Status last verified
May 2021
First submitted
20 Feb 2019
Last updated
14 Jun 2021
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Adell, R. (1987). Long-term treatment results. In: Brånemark, P-I., Zarb, G.A., Albrektsson, T. (Eds.). Tissue-integrated prostheses: osseointegration in clinical dentistry (pp. 175-285). Quintessence Publishing Co. Inc.

  • Albrektsson T, Branemark PI, Hansson HA, Lindstrom J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52(2):155-70. doi: 10.3109/17453678108991776.

    PubMed 7246093
  • Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants. 1986 Summer;1(1):11-25. No abstract available.

    PubMed 3527955
  • Bhaskaran V, Qualtrough AJ, Rushton VE, Worthington HV, Horner K. A laboratory comparison of three imaging systems for image quality and radiation exposure characteristics. Int Endod J. 2005 Sep;38(9):645-52. doi: 10.1111/j.1365-2591.2005.00998.x.

    PubMed 16104978
  • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307-10.

    PubMed 2868172
  • Branemark PI. Osseointegration and its experimental background. J Prosthet Dent. 1983 Sep;50(3):399-410. doi: 10.1016/s0022-3913(83)80101-2. No abstract available.

    PubMed 6352924
  • Brånemark P-I. (1987). Introduction to osseointegration. In Brånemark, P-I., Zarb, G.A., Albrektsson, T. (Eds.). Tissue-integrated prostheses: osseointegration in clinical dentistry (pp. 11-76). Quintessence Publishing Co. Inc.

  • De Bruyn H, Collaert B, Linden U, Flygare L. A comparative study of the clinical efficacy of Screw Vent implants versus Branemark fixtures, installed in a periodontal clinic. Clin Oral Implants Res. 1992 Mar;3(1):32-41. doi: 10.1034/j.1600-0501.1992.030106.x.

    PubMed 1420725
  • Galgut P. A comparison of different indices used in the clinical assessment of plaque and gingival bleeding. Clin Oral Investig. 1999 Jun;3(2):96-9. doi: 10.1007/s007840050085.

    PubMed 10803118
  • Niznick, G. A. (1989). Open letters no. 1 and no. 2 to the dental profession, Core-Vent Corporation Newsletter and manufacturer's product description. Encino, California USA.

  • Camarda AJ, Durand R, Benkarim M, Rompre PH, Guertin G, Ciaburro H. Prospective randomized clinical trial evaluating the effects of two different implant collar designs on peri-implant healing and functional osseointegration after 25 years. Clin Oral Implants Res. 2021 Mar;32(3):285-296. doi: 10.1111/clr.13699. Epub 2021 Jan 25.

    PubMed 33314332
  • Camarda AJ, Milot P, Ciaburro H, Rompre PH, Sallaleh I, Do CMA. Long-term randomized clinical trial evaluating the effects of fixture surface acid-etching and machined collar design on bone healing. Quintessence Int. 2018;49(9):733-743. doi: 10.3290/j.qi.a41013.

    PubMed 30202836

Questions about this trial

What is this clinical trial studying?

A study testing Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1), Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2) and Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3) in people with Jaw, Edentulous, run by Université de Montréal at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 14 Jun 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 14 Jun 2021). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Comparison of Distance Between First Bone to Implant Contact Point (fBIC) and Microgap (MG), After 25 Years of Function, Between All B, All SW, and All SC Dental Implant Units in All Three Configurations (time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03862482, which also lists 12 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Jun 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in