Scoliosis; AdolescenceNCT03825159

A New Spinal Orthosis for Adolescent Idiopathic Scoliosis

A study testing Spinal Orthosis with an Integrated System of Electric Surface Stimulation and Heat Sensing and spinal orthosis in people with Scoliosis; Adolescence, run by Changhua Christian Hospital at 1 site in Taiwan.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record

Search all trials

Trial summary

The new device with digital technology provides a new avenue to enable clinicians to communicate wirelessly with the imbedded core system such that they can adjust the electrical stimulation parameters and retrieve the temperature data for further compliance analysis. Read more about this study

Who is it for?
Ages 10 to 17 years
Conditions the study is for
Scoliosis; Adolescence
What is being tested?
Spinal Orthosis with an Integrated System of Electric Surface Stimulation and Heat Sensing and spinal orthosis
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteTaiwan
Study dates
1 Feb 2019to 31 Jan 2023
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 10 to 17 years
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • (1) the range of age should be from ten years old to seventeen years old and (2) the Cobb angle should be from 20°to 45°.

Who cannot join

  • (1)not primary idiopathic scoliosis (2)Unable to wear the all-day brace

Trial locations and contacts

1 site in 1 country.

Taiwan1 site, 1 recruiting
  • Changhua Christian Hospital Taiwan

    Changhua, 500

    Tseng, 886-4-7238595 ext. 4077, tasen@cch.org.tw

    Tasen Wei

    Recruiting

Other trials in Taiwan

About this study

Official title: A New Spinal Orthosis With an Integrated System of Electric Surface Stimulation and Heat Sensing for Adolescent Idiopathic Scoliosis

The new device with digital technology provides a new avenue to enable clinicians to communicate wirelessly with the imbedded core system such that they can adjust the electrical stimulation parameters and retrieve the temperature data for further compliance analysis. The smart phone and cloud technology can be effectively applied for both security and convenience. The electrical stimulation technology integrated with the total contact spinal orthosis combines the external correction forces on the spinal skeleton from the passive orthosis with the muscle forces at the lateral trunk from the stimulation process. The electrical stimulation is purposely to tone the muscle in order to replace the external mechanical forces gradually. Ultimately, when being weaned off the orthosis, patients may maintain the correction.

Read the detailed description

Spinal orthosis is an option to treat Adolescent Idiopathic Scoliosis (AIS) and is the most commonly used among conservative treatment. According to Scoliosis Research Society (SRS), orthotic treatment is indicated for AIS patients with curves greater than 25˚ but smaller than 45˚. However, the in-brace correction is hardly maintained and the effectiveness of orthotic treatment is limited, which has been an impetus to develop a more effective method for AIS patients to fulfill the unmet need. In order the orthosis is effective, biomechanical intervention and the patient compliance are two key factors. The purpose of this two-year project is to develop a new spinal orthosis in which an integrated system of electric surface stimulation and heat sensing is imbedded such that the AIS will be effectively treated with the mechanical orthosis plus a nocturnal use of electrical stimulation. In addition to the already stellar device, a totally new concept of spine erectability is proposed to provide evidence that can manifest the unique value of orthotic treatment as opposed to surgery. It is hypothesized that the new spinal orthosis would not only reduce the Cobb angle and apical rotation but also would strengthen the spine erectability in AIS patients. The new device with digital technology provides a new avenue to enable clinicians to communicate wirelessly with the imbedded core system such that they can adjust the electrical stimulation parameters and retrieve the temperature data for further compliance analysis. The smart phone and cloud technology can be effectively applied for both security and convenience. The electrical stimulation technology integrated with the total contact spinal orthosis combines the external correction forces on the spinal skeleton from the passive orthosis with the muscle forces at the lateral trunk from the stimulation process. The electrical stimulation is purposely to tone the muscle in order to replace the external mechanical forces gradually. Ultimately, when being weaned off the orthosis, patients may maintain the correction. With the spinal orthosis, the applied current in stimulation process would be reduced and the skin irritation would too. First year, there will be three tasks. An instrument will be developed for clinicians to assess the applicability of electrical surface stimulation to each AIS patient. System integration of the spinal orthosis with electrical surface stimulation and heat sensing will be accomplished. Clinical study of the effectiveness of passive spinal orthoses on 30 AIS subjects as a control group, where the Cobb angle, apical rotation and spine erectability will be measured before treatment and after. Second year, another 30 AIS patients will be recruited; the applicability of electrical surface stimulation will be assessed; and the new spinal orthosis will be applied to the experiment group. The Cobb angle, apical rotation and spine erectability will be measured before treatment and after for each subject. Independent t test will be carried out for the two groups to test the hypothesis.

Being tested
Spinal Orthosis with an Integrated System of Electric Surface Stimulation and Heat Sensing, spinal orthosis
Medical subject headings
Scoliosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Spinal Orthosis with an Integrated System of Electric Surface Stimulation and Heat SensingDevice

    The electrical stimulation technology integrated with the total contact spinal orthosis combines the external correction forces on the spinal skeleton from the passive orthosis with the muscle forces at the lateral trunk from the stimulation process.

  • spinal orthosisDevice

    Also called Scoliosis brace

    The ventrally opened total contact spinal orthosis will be designed and made of Copolymer and Aliplast. Correcting pressure points have to use the pressure pads at relevant points.

Study groups in NCT03825159
Study groupRoleWhat they receive
ES groupExperimentalUsing spinal orthosis with an integrated system of electric surface stimulation and heat sensing.
Receives: Device: Spinal Orthosis with an Integrated System of Electric Surface Stimulation and Heat Sensing
brace groupActive comparatorUsing spinal orthosis BRACE
Receives: Device: spinal orthosis

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change of Cobb angle

    When measuring Cobb angle, the investigators should identify the upper and lower end vertebra. Then, the investigators draw perpendicular lines extending along the vertebral borders. The angle where two perpendicular lines meet is called Cobb angle

    Measured: base line, 6th month and 12th month

  2. Change of Spine erectability

    Spine erectability is to define the physiological ability of the spine to maintain it erect against gravity and will be assessed without wearing orthoses.

    The force F acting at the apex is the weights of the head and two upper limbs plus 7/17 trunk weight, which can be calculated with the readily available anthropometric data. The bending moment M at T8 equals the applied force F multiplies the lever arm d, which is the distance between the force and the weight line.

    SE=(Weight*7/17)*d/(Cobb angle in standing-Cobb angle in supine)

    Measured: base line, 6th month and 12th month

  3. Change of Apical rotation

    Apical rotation is the degree of apical vertebral rotation .The Raimondi method uses the projection of the vertebral pedicles and the width of the vertebra as a reference for the measuring. The largest axis of the pedicle is demarcated and measured on the side of the curve convexity, and the distance of the longitudinal line from the pedicle to the border of the vertebra on the convex side is measured. Those two values are transported to the ruler, and the value of the rotation is obtained.

    Measured: base line, 6th month and 12th month

Secondary outcomes (4)
  1. Back muscles surface ElectroMyoGraphy (EMG)

    Use a non-invasive surface EMG tool to collect muscle activities on the upper and lower back area, while the subject performs the trunk flexion-extension-lateral rotation with standing posture.

    Measured: base line, 6th month and 12th month

  2. Back movement pathway

    Use cameras to record the back motion pathway during trunk flexion-extension \& lateral rotations, while the subject performs the trunk flexion-extension-lateral rotation with standing posture.

    Measured: base line, 6th month and 12th month

  3. Distributions of Pressure under the feet

    Use a flat pressure mat embedded in the walkway to collect the foot pressure distribution during static standing and dynamic walking.

    Measured: base line, 6th month and 12th month

  4. The nerve morphological connectivity

    The subject's diffusion tensor features are extracted from functional Magnetic Resonance Imaging of head. The features would include the never connectivity, pathway, the size of nuclei.

    Measured: base line,12th month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted31 Jan 2019
  2. Study start1 Feb 2019
  3. Primary completion31 Dec 2022 (estimated)
  4. Study completion31 Jan 2023 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
60 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03825159
Sponsor's protocol ID
CCH-170102
Status last verified
Jun 2021
First submitted
30 Dec 2018
Last updated
2 Jul 2021
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in