Ventricular FibrillationASENCT03802110
Acute Feasibility Investigation of a New S-ICD Electrode
A study testing commercially released subcutaneous implantable cardioverter defibrillator (S-ICD) and the Investigational S-ICD Adapter. in people with Ventricular Fibrillation, run by Boston Scientific Corporation at 4 sites in Netherlands.
Trial summary
This is an early-stage feasibility study. This study seeks to characterize the performance of the new electrode shock configuration with the S-ICD Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Ventricular Fibrillation
- What is being tested?
- commercially released subcutaneous implantable cardioverter defibrillator (S-ICD) and the Investigational S-ICD Adapter.
- Type of treatment
- Injection or infusion, Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 42 participants
- Where
- 4 sitesNetherlands
- Study dates
- 29 Nov 2018to 1 Apr 2022
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Subject is scheduled to receive a de novo S-ICD system implant per labeled indication.
- Passing S-ICD screening ECG performed per applicable user's manual.
- Subject is willing and capable of providing informed consent specific to local and national laws.
- Subject is age 18 or above, or of legal age to give informed consentspecific to local and national law.
Who cannot join
- Subject has an unusual chest anatomy (eg. pectus excavatum and pectus carinatum) that might impede the ability to temporarily insert a second S-ICD electrode.
- Subject has a left ventricular ejection fraction ≤ 20% within 3 months prior to enrollment.
- Subject has NYHA Class IV or unstable Class III heart failure.
- Subject that, in the opinion of the investigator, cannot tolerate the DFT testing required by this protocol.
- Subject is morbidly obese, defined as BMI ≥ 35.
- Subject has an active infection or has been treated for infection within the past 30 days.
Show all 13Show fewer
- Subject that, in the opinion of the investigator, has an increased risk of infection.
- Subject is currently requiring/receiving dialysis.
- Subject has insulin-dependent diabetes.
- Subject had/has any prior or planned other surgical procedure within ±30 days of enrollment.
- Subject that, in the opinion of the investigator, has an increased risk for thromboembolic event.
- Subject that, in the opinion of the investigator, has an increased risk of excessive bleeding.
- Subject is currently on an active heart transplant list.
Trial locations and contacts
4 sites in 1 country.
Netherlands4 sites
Academisch Medisch Centrum
Amsterdam
St. Antonius Ziekenhuis
Nieuwegein
Erasmus MC - University Medical Center Rotterdam
Rotterdam
Isala Klinieken
Zwolle
About this study
Official title: Acute Feasibility Investigation of a New S-ICD Electrode Arrangement for Reduction of Defibrillation Energies
This is an early-stage feasibility study. This study seeks to characterize the performance of the new electrode shock configuration with the S-ICD
Read the detailed description
Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD, EMBLEM®, Boston Scientific Corp) delivers 80 J shocks from an 8 cm left-parasternal coil (LPC) to a 59 cc left lateral pulse generator (PG). A system that defibrillates with lower energy could significantly reduce PG size. Computer modeling and animal studies suggest a 2nd shock coil either parallel (P) to LPC or transverse (T) from xiphoid to PG pocket would significantly reduce shock impedance and defibrillation threshold (DFT).
Objective: Acutely test defibrillation efficacy of P and T configurations in patients receiving an S-ICD.
Methods: Testing was performed in patients receiving a conventional S-ICD system (C) for standard indications. Patients at risk for conversion failure, stroke or infection were excluded. A 65 J success with the conventional S-ICD was required prior to investigational testing. A second electrode was temporarily inserted from the xiphoid incision using the same introducer and sheath tools and connected to the PG with an investigational Y-adapter (Model 3598, Boston Scientific). Phase 1 (n=11) tested only P at a starting energy of 50 J with subsequent tests at 65 or 30 J then 40 or 20 J depending upon outcome. Phase 2 (n=21) tested both P and T in random order, starting at 30 J then either 40 or 20 J.
- Conditions
- Ventricular Fibrillation
- Being tested
- commercially released subcutaneous implantable cardioverter defibrillator (S-ICD) and the Investigational S-ICD Adapter.
- Medical subject headings
- Ventricular Fibrillation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
commercially released subcutaneous implantable cardioverter defibrillator (S-ICD) and the Investigational S-ICD Adapter.Device
Also called The S-ICD System is a Subcutaneous (under the skin) Implantable Cardioverter Defibrillator for people who are at risk of Sudden Cardiac Arrest
The S-ICD System is a Subcutaneous (under the skin) Implantable Cardioverter Defibrillator for people who are at risk of Sudden Cardiac Arrest. A new electrode configuration will be tested for Defibrillation testing ( DFT). The unit of measure will be in Joules. VF will be induced and the device will deliver a shock at a certain defined energy level as described in the protocol
| Study group | Role | What they receive |
|---|---|---|
| Single Arm | Experimental | Defibrillation threshold (DFT) testing Arm Receives: Device: commercially released subcutaneous implantable cardioverter defibrillator (S-ICD) and the Investigational S-ICD Adapter. |
What is being measured
The primary outcome is the main question the study is designed to answer.
Defibrillation Threshold (DFT) of the New Shock Electrode Configuration in Joules
The primary objective of this acute feasibility study is to measure the DFT of the new shock electrode configuration with an S-ICD system. The unit of measure will be in Joules. Ventricular Fibrillation (VF) will be induced and the device will deliver a shock at a certain defined energy level as described in the protocol
Measured: Acute- During the implant procedure- up to 1 hour
Secondary outcomes (1)
Number of Participants With Successful Ventricular Fibrillation (VF) Conversion at 40 Joules
The secondary objective is to assess the conversion success of the new electrode configuration to convert VF. VF will be induced and the device will deliver a shock at a certain defined energy level as described in the protocol
Measured: Acute- During the implant procedure- up to 1 hour
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted14 Jan 2019
- Study start29 Nov 2018
- Primary completion1 Apr 2022
- Study completion1 Apr 2022
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for Ventricular FibrillationStudies of the same condition, open and under way.
- More trials run by Boston Scientific CorporationThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 42 participants (actual)
Sponsor and investigators
- Lead sponsor
- Boston Scientific Corporation
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Reinoud Knops, Principal investigator, Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03802110
- Sponsor's protocol ID
- C2081
- Acronym
- ASE
- Status last verified
- Oct 2023
- First submitted
- 8 Nov 2018
- Last updated
- 9 May 2024
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 9 May 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Acute Feasibility Investigation of a New S-ICD Electrode Arrangement for Reduction of Defibrillation Energies
- ClinicalTrials.gov ID
- NCT03802110
- Acronym / sponsor ID
- ASE / C2081
- Conditions
- Ventricular Fibrillation
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 42 participants (actual)
- Lead sponsor
- Boston Scientific CorporationIndustry (pharma, biotech, devices)
- Study start
- 29 Nov 2018 (actual)
- Primary completion
- 1 Apr 2022 (actual)
- Study completion
- 1 Apr 2022 (actual)
- First posted
- 14 Jan 2019 (actual)
- Results
- Posted 9 May 2024
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is an early-stage feasibility study. This study seeks to characterize the performance of the new electrode shock configuration with the S-ICD
Detailed description
Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD, EMBLEM®, Boston Scientific Corp) delivers 80 J shocks from an 8 cm left-parasternal coil (LPC) to a 59 cc left lateral pulse generator (PG). A system that defibrillates with lower energy could significantly reduce PG size. Computer modeling and animal studies suggest a 2nd shock coil either parallel (P) to LPC or transverse (T) from xiphoid to PG pocket would significantly reduce shock impedance and defibrillation threshold (DFT).
Objective: Acutely test defibrillation efficacy of P and T configurations in patients receiving an S-ICD.
Methods: Testing was performed in patients receiving a conventional S-ICD system (C) for standard indications. Patients at risk for conversion failure, stroke or infection were excluded. A 65 J success with the conventional S-ICD was required prior to investigational testing. A second electrode was temporarily inserted from the xiphoid incision using the same introducer and sheath tools and connected to the PG with an investigational Y-adapter (Model 3598, Boston Scientific). Phase 1 (n=11) tested only P at a starting energy of 50 J with subsequent tests at 65 or 30 J then 40 or 20 J depending upon outcome. Phase 2 (n=21) tested both P and T in random order, starting at 30 J then either 40 or 20 J.
Study design
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Single Arm | Experimental | Device: commercially released subcutaneous implantable cardioverter defibrillator (S-ICD) and the Investigational S-ICD Adapter.Defibrillation threshold (DFT) testing Arm |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Subject is scheduled to receive a de novo S-ICD system implant per labeled indication.
- Passing S-ICD screening ECG performed per applicable user's manual.
- Subject is willing and capable of providing informed consent specific to local and national laws.
- Subject is age 18 or above, or of legal age to give informed consentspecific to local and national law.
Key exclusion criteria (13 listed)
- Subject has an unusual chest anatomy (eg. pectus excavatum and pectus carinatum) that might impede the ability to temporarily insert a second S-ICD electrode.
- Subject has a left ventricular ejection fraction ≤ 20% within 3 months prior to enrollment.
- Subject has NYHA Class IV or unstable Class III heart failure.
- Subject that, in the opinion of the investigator, cannot tolerate the DFT testing required by this protocol.
- Subject is morbidly obese, defined as BMI ≥ 35.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| commercially released subcutaneous implantable cardioverter defibrillator (S-ICD) and the Investigational S-ICD Adapter.Also: The S-ICD System is a Subcutaneous (under the skin) Implantable Cardioverter Defibrillator for people who are at risk of Sudden Cardiac ArrestThe S-ICD System is a Subcutaneous (under the skin) Implantable Cardioverter Defibrillator for people who are at risk of Sudden Cardiac Arrest. A new electrode configuration will be tested for Defibrillation testing ( DFT). The unit of measure will be in Joules. VF will be induced and the device will deliver a shock at a certain defined energy level as described in the protocol | Device | Single Arm |
Primary outcome
Defibrillation Threshold (DFT) of the New Shock Electrode Configuration in Joules
Time frame: Acute- During the implant procedure- up to 1 hour
The primary objective of this acute feasibility study is to measure the DFT of the new shock electrode configuration with an S-ICD system. The unit of measure will be in Joules. Ventricular Fibrillation (VF) will be induced and the device will deliver a shock at a certain defined energy level as described in the protocol
1 secondary outcome
Number of Participants With Successful Ventricular Fibrillation (VF) Conversion at 40 Joules
Time frame: Acute- During the implant procedure- up to 1 hour
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 May 2024.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: No
Related trials for Ventricular Fibrillation
Active, not recruiting
Assessment of Combined CCM and ICD Device in HFrEF
Heart Failure, Heart Failure With Reduced Ejection Fraction
Recruiting
A Study Assessing Arrhythmia Mapping With a Multi-Electrode Mapping Catheter
Scar-related Atrial Tachycardia, Persistent Atrial Fibrillation
RecruitingObservational study
AI-Based Cardiac Analysis Using 12-Lead and 1-Lead ECG
Heart Failure, Atrial Fibrillation (AF)
RecruitingObservational study
Observational Study of Cardiac Arrhythmias During Treatment With BTK Inhibitors or Venetoclax
Chronic Lymphocytic Leukemia (CLL), Waldenstr(SqrRoot)(Delta)m s Macroglobulinemia
Recruiting
Bundle Branch Pacing to Preserve Ejection Fraction in Atrial Fibrillation Trial
Permanent Atrial Fibrillation, Preserved Ejection Fraction
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Reinoud Knops principal investigator
Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
4 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing commercially released subcutaneous implantable cardioverter defibrillator (S-ICD) and the Investigational S-ICD Adapter. in people with Ventricular Fibrillation, run by Boston Scientific Corporation at 4 sites in Netherlands.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 9 May 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 4 sites in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 9 May 2024). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Defibrillation Threshold (DFT) of the New Shock Electrode Configuration in Joules (time frame: Acute- During the implant procedure- up to 1 hour). It is what the study was designed to measure, not a finding.