AzTrials
AzTrials

Intraoperative HypotensionNCT03795831

Validation Study in Patients of a Non-invasive Blood Pressure Monitor for Perioperative Use

An observational study of Intraoperative Hypotension, run by Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA) at 1 site in Netherlands.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Collecting all available data (waveforms, beat to beat data, status data) generated by a non invasive blood pressure monitor on each hand and compare this to the actual data obtained by intra arterial (radial) monitoring. This to see if the non invasive bloodpressure monitor can be validated for intraoperative use. Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Intraoperative Hypotension
What is being tested?
ClearSight feasibility testing
Type of treatment
Medical device
How many people
100 participants
Where
1 siteNetherlands
Study dates
1 Mar 2017to 30 Dec 2019
How long will I take part?
1 Day
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Study population: Patients in a perioperative setting already monitored with a system that accurately measures and stores the intra-arterial waveform, such as the FloTrac system in the EV1000 monitor.

Who may be able to join

  • Patients whose arterial blood pressure is measured invasively with technology that allows for the storage of the intra-arterial waveform with sufficient quality and resolution (Flotrac).
  • Patients older than 18, for elective general surgery.

Who cannot join

  • Patient conditions that are expected to potentially and significantly affect the transfer of pressure between radial artery and the finger, e.g. due to recent finger fractures

Trial locations and contacts

1 site in 1 country.

D.P. Veelo, Dr contact

0031205662533

d.p.veelo@amc.uva.nl

Netherlands1 site, 1 recruiting
  • Academic Medical Center

    Amsterdam, 1105AZ

    D.P. Veelo, Dr., 0031205662533, d.p.veelo@amc.uva.nl

    Recruiting

Other trials in Netherlands

About this study

Collecting all available data (waveforms, beat to beat data, status data) generated by a non invasive blood pressure monitor on each hand and compare this to the actual data obtained by intra arterial (radial) monitoring.

This to see if the non invasive bloodpressure monitor can be validated for intraoperative use.

Read the detailed description

Although a blood pressure monitoring device could be evaluated by the comparing systolic, diastolic and mean arterial pressure to a reference pressure, it is the specific aim to collect all available data (waveforms, beat to beat data, status data) generated by the blood pressure monitor.

After data analysis and comparison to patient's actual intra-arterial waveform, the outcome will be evaluated by Association for the Advancement of Medical Instrumentation (AAMI) standards to see if the non invasive bloodpressure monitor can be validated for intraoperative use.

The study is targeted at patients already monitored with a system that accurately measures and stores the intra-arterial waveform, such as the FloTrac system in the EV1000 monitor.

This study is a substudy of a feasability protocol evaluating a new algorithm for the Clearsight system.

Being tested
ClearSight feasibility testing

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ClearSight feasibility testingDevice

    A cuff is placed on a finger of the patient. The ClearSight system uses a volume clamp technology allowing measuring of continuous blood pressure waveform. Note: There will only be observational recordings, no interventions

Study groups in NCT03795831
Study groupRoleWhat they receive
CohortAdult patients, undergoing surgery requiring general anesthesia, planned to be monitored with a system that accurately measures and stores the intra-arterial waveform.
Receives: Device: ClearSight feasibility testing

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. validation systole, diastole, mean ABP and pulse pressure

    accuracy and precision of invasive blood pressure curve vs non-invasive blood pressure curves(ipsilateral and contralateral)

    Measured: within 1 hour

  2. implementation of software alterations to improve systole, diastole, mean ABP accuracy and pulse pressure

    Comparison of the non-invasive blood pressure curve after software alterations to the reference and invasive arterial blood pressure curve

    Measured: time during surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Jan 2019
  2. Study start1 Mar 2017
  3. Primary completion30 Dec 2019 (estimated)
  4. Study completion30 Dec 2019 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
100 participants (estimated)
Target duration
1 Day
IDs, dates and publications
ClinicalTrials.gov ID
NCT03795831
Sponsor's protocol ID
2017-14
Status last verified
Jan 2019
First submitted
4 Jan 2019
Last updated
10 Jan 2019
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
Undecided

Publications

  • Rellum SR, Noteboom SH, van der Ster BJP, Schuurmans J, Kho E, Vlaar APJ, Schenk J, Veelo DP. The hypotension prediction index versus mean arterial pressure in predicting intraoperative hypotension: A clinical perspective. Eur J Anaesthesiol. 2025 Jun 1;42(6):527-535. doi: 10.1097/EJA.0000000000002150. Epub 2025 Feb 27.

    PubMed 40012367
  • Rellum SR, Kho E, Schenk J, van der Ster BJP, Vlaar APJ, Veelo DP. A comparison between invasive and noninvasive measurement of the Hypotension Prediction Index: A post hoc analysis of a prospective cohort study. Eur J Anaesthesiol. 2025 Feb 1;42(2):131-139. doi: 10.1097/EJA.0000000000002082. Epub 2024 Oct 16.

    PubMed 39411994
  • Kho E, van der Ster BJP, van der Ven WH, Vlaar APJ, Immink RV, Veelo DP. Clinical agreement of a novel algorithm to estimate radial artery blood pressure from the non-invasive finger blood pressure. J Clin Anesth. 2022 Dec;83:110976. doi: 10.1016/j.jclinane.2022.110976. Epub 2022 Sep 26.

    PubMed 36174389

Questions about this trial

What is this clinical trial studying?

An observational study of Intraoperative Hypotension, run by Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA) at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 10 Jan 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact D.P. Veelo, Dr (0031205662533, d.p.veelo@amc.uva.nl), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

validation systole, diastole, mean ABP and pulse pressure (time frame: within 1 hour). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03795831, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Jan 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in