Transcranial Direct Current StimulationTESNCT03772210
Mechanism and Dosimetry Exploration in TES Magnetic Resonance Current Mapping Methods
A study testing tDCS in people with Transcranial Direct Current Stimulation, run by Arizona State University at 2 sites in United States.
Trial summary
In this study the investigators will explore dosimetry in transcranial electrical stimulation using a novel magnetic resonance imaging technique that can determine how electrical stimulation distributes within the brain. Read more about this study
- Who is it for?
- Ages 18 to 30 yearsHealthy volunteers can take part
- Conditions the study is for
- Transcranial Direct Current Stimulation
- What is being tested?
- tDCS
- Type of treatment
- Medical device
- Could I receive a placebo?
- Yes, some participants may receive a placebo
- How many people
- 123 participants
- Where
- 2 sitesUnited States
- Study dates
- 3 Jan 2019to 9 Jun 2022
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 30 years
- All sexes
- Healthy volunteers accepted
- Adult
Who may be able to join
- We will include neurologically normal volunteer subjects between 18-30 years of age in the study, minors will not be targeted.
- English as Native Language
Who cannot join
- Adults who are unable to consent will not be included in the study.
- Pregnancy
- Subjects will not have any implanted or attached metallic devices.
- Appreciable deficits in hearing
- Appreciable problems with articulation
- Neuroanatomic abnormality
Show all 13Show fewer
- Any neurological disorder associated with cognitive impairment.
- Any implanted cardiac pacemaker
- Dementia or Mini-Mental State Exam <24
- Low estimated verbal intelligence per WTAR
- Active or Prior history of Seizure Disorder
- Family History of Seizure disorder
- Prescribed Seizure inducing medication
Trial locations and contacts
2 sites in 1 country.
United States2 sites
University of Florida
Gainesville, Florida, 32611
Arizona State University
Tempe, Arizona, 85287-9709
About this study
Official title: Mechanism and Dosimetry Exploration in Transcranial Electrical Stimulation Using Magnetic Resonance Current Mapping Methods
In this study the investigators will explore dosimetry in transcranial electrical stimulation using a novel magnetic resonance imaging technique that can determine how electrical stimulation distributes within the brain. The investigators will then combine this imaging technique with functional MR imaging to attempt mechanistic associations. If successful, the study outcomes will be an improved understanding of the interactions between electric current distributions and structures presumed to be targeted by stimulation.
Read the detailed description
Transcranial electrical stimulation (tES) techniques such as transcranial DC stimulation (tDCS) and transcranial AC stimulation (tACS) have been indicated for conditions as diverse as stroke rehabilitation, epilepsy and for improvements in memory tasks. Thousands of tES studies have been published since 20001. In typical tDCS procedures a pair of large electrodes (e.g., 25cm2) is attached to the scalp and a constant current of 1-2 mA passed between them for periods of 10-30 min. In tACS, the constant current intensity is similar, but an alternating sinusoidal waveform is usually employed. Variations on these techniques exist. For example, in oscillatory tDCS, a temporally oscillating current is combined with a DC offset current. In transcranial random noise stimulation (tRNS) temporally random currents with a fixed maximum intensity are applied. These transcranial electrical neuromodulation strategies have been indicated for a wide range of conditions, including stroke rehabilitation, treatment of epilepsy and for improving cognitive, motor and language and memory performance in healthy subjects. Details of the underlying mechanisms of both tDCS and tACS remain unclear. It has been assumed that the effects of tDCS are greatest in brain structures nearest to stimulating electrodes and that these structures experience the largest electric fields or current flow. In tDCS applied at 1 mA current intensities, it has been found that excitatory effects broadly correlate with placement of more positive electrodes over a targeted structure, and inhibitory effects are observed in structures under cathodes. It has been hypothesized that this is because externally applied field either depolarizes or hyperpolarizes resting membrane voltages in targeted tissue, leading to increased excitability or inhibition respectively. This suggests that increased excitability or inhibition would result when current intensity is increased. However, there is also evidence that at 2 mA intensity increased excitability is observed, regardless of polarity. The effects observed may also depend on the total stimulation time.
In tACS, it has been found that at low frequencies (up to 80 Hz) tACS excitation frequencies may entrain neural networks with excitatory or inhibitory effects that depend on the frequency chosen, the current intensity and the phase of current application relative to underlying EEG rhythms.
Intersubject variability has been reported in both tDCS and tACS, and study reproducibility has been problematic. Apart from factors relating to the subject initial state, individual neuroanatomy and differences in cerebrospinal fluid volume, it has also been suggested that major contributions to variability between individual sessions of a study or may be inconsistencies in electrode application protocol. In particular, overuse of saline contact medium can result in the effective electrode area increasing beyond the electrode face, and if fastening straps are thinner than electrodes, contact area may be reduced. Electrodes may also move during sessions, or be placed inconsistently on different subjects. Between sites, reproducibility may be degraded because electrode shapes, types and placements are not consistent.
Knowledge of the exact distribution formed within the brain by the externally applied currents would clarify many study outcomes and most importantly allow more precise explorations of mechanism. Further, the effects of different current application protocols, electrode designs and study procedures could easily be resolved. Thus, a method for measuring current distributions formed by tDCS or tACS would answer many questions in this active field.
In the absence of methods for easily measuring or imaging current flow distributions, computational models have been used extensively to predict flow patterns. A large literature exists using computational models to explore effects of different montages, electrode areas and geometries on voltage distributions, electric fields or current flow. Increasingly sophisticated approaches have been devised to model the head subject to tDCS stimulation. As the field has grown, head model complexity has increased from spherical uniform, spherical four-compartment, realistic geometry, to high-resolution anisotropic models of the human head subject to electrical stimulation. This last category has involved merging source images based on MR images with diffusion-weighted images of the subject to predict white matter conductivity tensors. One approach to this uses water translational diffusion tensor eigenvectors to determine the direction of the conductivity tensor (assuming they are co-aligned) in combination with literature values of white matter conductivities. Another approach involves direct scaling of the white matter diffusion tensor to conductivity values. Most other model tissue conductivities are chosen from values measured on bulk tissues in the literature. However, to date no validation of these models has been possible in human subjects.
Some efforts have been made to measure current distributions resulting from tDCS. In a recent paper, Opitz et al. measured electric field distributions caused by transcranial stimulation via electrodes placed in a bilateral montage (left and right temples) using electrode arrays placed near the cortical surface of patients being monitored to identify epilepsy seizure foci. tACS was applied at 1-15 Hz with an intensity of 1 mA, and maximum electrical field strengths of 0.36 and 0.16 mV/mm were identified. A slight frequency dependent increase in conductivity (ca. 10%) was observed, and little capacitive effect. Again, these field strengths would not normally be sufficient to cause direct tissue stimulation, and support theories that slight depolarizations may be responsible for tDCS effects.
Researchers seeking to understand tES mechanisms have initiated fMRI studies to investigate the correlation of therapeutic current administration and brain activity as evidenced by changes in the BOLD contrast18-20. In the course of this research it has been noted that current administration creates artifacts on MR images. In another paper, fMRI analysis methods were used to find voxel clusters correlating with current flow features22. However, to date, there have been no attempts to non-invasively image tDCS or tACS current density distributions in humans directly.
The technique of Current Density Imaging (CDI) as suggested by Scott et al. (1991) is a method for translating the phase part of magnetic resonance images into individual magnetic flux density vector components caused by an externally applied current flow. These measurements can then be used to compute current density distributions using Ampere's law. The basic CDI technique requires the external current to be injected into subjects in concert with a sequence of RF pulses and gradient fields used to create MR images. The technique was demonstrated in phantoms and used to image current flow in a rabbit brain. Unfortunately, it is infeasible in humans because of the need to rotate the subject twice inside the scanner bore in order to obtain all three components of the magnetic flux density.
MR Electrical Impedance Tomography (MREIT) has been developed over the last decade as a method for imaging current density and conductivity distributions in the human body. As in CDI, MREIT requires current to be applied to a subject in conjunction with a particular MR sequence. However, MREIT methods make it possible to reconstruct conductivity, electric field and current density distributions in subjects by using only one component (Bz) of magnetic flux density vectors. A recently developed MREIT method, DT-MREIT, can be used to reconstruct full anisotropic conductivities and current density distributions using MREIT and DTI data gathered from the same subject, and has recently been demonstrated in canines.
In this work, the investigators will use MREIT methods to produce:
- Quantitative physical measures demonstrating tES reproducibility, exploring effects of current intensity, sex and neuroanatomic differences on measured current distributions.
- Comparisons of actual current density distributions developed in a target structure (DLPFC) with fMRI measures of activity.
These studies will provide the first tests of the assumptions that
- effects of tDCS stimulation are largest in the targeted region
- that the largest field and current flow is found in the targeted region These studies therefore have the potential to revolutionize understanding of tES mechanisms and practice.
This work has three aims, one focused on technical improvements in our present MREIT acquisition procedures, another targeted at quantifying replicability, measuring current flow distributions at different current intensities, and finally, in assessing correlations of electric field and current density distributions with brain activity measures using fMRI.
Specific Aim 1 (SA1) MREIT Pulse Sequence Acceleration and Improvements.
Specific Aim 2 (SA2) Replicability and Consistency in tDCS/tACS Protocols Current density distributions will be imaged in normal volunteers using an F3-F4 montage with three different current intensities, and repeat the measure at intervals of at least one week. Each time, the montage will be reapplied and subjects re-imaged. Both intra- and inter-subject variations in measured current and electric field distributions will be determined.
Specific Aim 3 (SA3) Correlation of functional measures with measured electrical distribution measures Participants' performance on a 2-back/0-back memory task will be compared in both Sham and Active subjects, using either 1, 1.5 or 2 mA intensity stimulation.
- Conditions
- Transcranial Direct Current Stimulation
- Being tested
- tDCS, Sham
- Keywords
- fMRI, mechanism, tDCS, neuromodulation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
tDCSDevice
Current will be administered to subject groups as specified in arm descriptions.
ShamOther
Apparent Stimulation administered
| Study group | Role | What they receive |
|---|---|---|
| Current Intensity 1 mA | Active comparator | tDCS will be administered at an intensity of 1 mA to locations F3-F4, and fMRI response during performance of a 3-back/0-back memory task will be assessed. Receives: Device: tDCS |
| Sham 1 mA | Sham comparator | Determine fMRI response during performance of a 3-back/0-back memory task with sham 1 mA tDCS. Receives: Other: Sham |
| Current Intensity 1.5 mA | Active comparator | tDCS will be administered at an intensity of 1.5 mA to locations F3-F4, and fMRI response during performance of a 3-back/0-back memory task will be assessed. Receives: Device: tDCS |
| Sham 1.5 mA | Sham comparator | Determine fMRI response during performance of a 3-back/0-back memory task with sham 1.5 mA tDCS. Receives: Other: Sham |
| Current Intensity 2 mA | Active comparator | tDCS will be administered at an intensity of 2 mA to locations F3-F4, and fMRI response during performance of a 3-back/0-back memory task will be assessed. Receives: Device: tDCS |
| Sham 2 mA | Sham comparator | Determine fMRI response during performance of a 3-back/0-back memory task with sham 2 mA tDCS. Receives: Other: Sham |
| Structural, Diffusion and MREIT Imaging | Experimental | Structural and High angular resolution diffusion weighted imaging will be performed.
Magnetic Resonance Electrical Impedance Tomography imaging will be performed using electrode locations F3-F4. Receives: Device: tDCS |
What is being measured
The primary outcome is the main question the study is designed to answer.
Replicability
MREIT data will be obtained multiple times for each subject
Measured: 3 weeks
Comparison of measured current distribution with fMRI result
Measured current distributions will be correlated with fMRI results and task accuracies
Measured: 2 weeks
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted11 Dec 2018
- Study start3 Jan 2019
- Primary completion31 May 2022
- Study completion9 Jun 2022
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Transcranial Direct Current StimulationStudies of the same condition, open and under way.
- More trials run by Arizona State UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Basic science
- Allocation
- Randomised
- Intervention model
- Crossover
- Model description
- Structural (T1-weighted) and high angular resolution diffusion images of participant heads will be obtained. Current density distributions in normal participants will be imaged using an F3-F4 montage at three different current intensities. Measures will be repeated at intervals of at least one week. Each time, the montage will be reapplied and subjects re-imaged. Because the imaging method is quantitative, these measures will be used to provide an indication of baseline replicability. Both intra- and inter-subject variations in measured current and electric field distributions will be determined. Participant performance on a 3-back/0-back memory task will be compared in both Sham and Active subjects, using either 1, 1.5 or 2 mA intensity stimulation.
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 123 participants (actual)
Sponsor and investigators
- Lead sponsor
- Arizona State University
- Sponsor type
- University, hospital or other
- Collaborators
- National Institute of Mental Health (NIMH)
- Responsible party
- Sponsor
- Investigators
- Rosalind J Sadleir, PhD, Principal investigator, Arizona State University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03772210
- Sponsor's protocol ID
- STUDY00006012
- Other IDs
- RF1MH114290
- Acronym
- TES
- Status last verified
- Jun 2022
- First submitted
- 10 Dec 2018
- Last updated
- 27 Jun 2022
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Yes: Data will be shared via the NIMH Data Archive (NDAR)
Study at a glance
From the registry record, last updated by the sponsor on 27 Jun 2022. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Mechanism and Dosimetry Exploration in Transcranial Electrical Stimulation Using Magnetic Resonance Current Mapping Methods
- ClinicalTrials.gov ID
- NCT03772210
- Acronym / sponsor ID
- TES / STUDY00006012
- Conditions
- Transcranial Direct Current Stimulation
- Keywords
- fMRI, mechanism, tDCS, neuromodulation
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 123 participants (actual)
- Lead sponsor
- Arizona State UniversityUniversity, hospital or other
- Collaborators
- National Institute of Mental Health (NIMH)
- Study start
- 3 Jan 2019 (actual)
- Primary completion
- 31 May 2022 (actual)
- Study completion
- 9 Jun 2022 (actual)
- First posted
- 11 Dec 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
In this study the investigators will explore dosimetry in transcranial electrical stimulation using a novel magnetic resonance imaging technique that can determine how electrical stimulation distributes within the brain. The investigators will then combine this imaging technique with functional MR imaging to attempt mechanistic associations. If successful, the study outcomes will be an improved understanding of the interactions between electric current distributions and structures presumed to be targeted by stimulation.
Detailed description
Transcranial electrical stimulation (tES) techniques such as transcranial DC stimulation (tDCS) and transcranial AC stimulation (tACS) have been indicated for conditions as diverse as stroke rehabilitation, epilepsy and for improvements in memory tasks. Thousands of tES studies have been published since 20001. In typical tDCS procedures a pair of large electrodes (e.g., 25cm2) is attached to the scalp and a constant current of 1-2 mA passed between them for periods of 10-30 min. In tACS, the constant current intensity is similar, but an alternating sinusoidal waveform is usually employed. Variations on these techniques exist. For example, in oscillatory tDCS, a temporally oscillating current is combined with a DC offset current. In transcranial random noise stimulation (tRNS) temporally random currents with a fixed maximum intensity are applied. These transcranial electrical neuromodulation strategies have been indicated for a wide range of conditions, including stroke rehabilitation, treatment of epilepsy and for improving cognitive, motor and language and memory performance in healthy subjects. Details of the underlying mechanisms of both tDCS and tACS remain unclear. It has been assumed that the effects of tDCS are greatest in brain structures nearest to stimulating electrodes and that these structures experience the largest electric fields or current flow. In tDCS applied at 1 mA current intensities, it has been found that excitatory effects broadly correlate with placement of more positive electrodes over a targeted structure, and inhibitory effects are observed in structures under cathodes. It has been hypothesized that this is because externally applied field either depolarizes or hyperpolarizes resting membrane voltages in targeted tissue, leading to increased excitability or inhibition respectively. This suggests that increased excitability or inhibition would result when current intensity is increased. However, there is also evidence that at 2 mA intensity increased excitability is observed, regardless of polarity. The effects observed may also depend on the total stimulation time.
In tACS, it has been found that at low frequencies (up to 80 Hz) tACS excitation frequencies may entrain neural networks with excitatory or inhibitory effects that depend on the frequency chosen, the current intensity and the phase of current application relative to underlying EEG rhythms.
Intersubject variability has been reported in both tDCS and tACS, and study reproducibility has been problematic. Apart from factors relating to the subject initial state, individual neuroanatomy and differences in cerebrospinal fluid volume, it has also been suggested that major contributions to variability between individual sessions of a study or may be inconsistencies in electrode application protocol. In particular, overuse of saline contact medium can result in the effective electrode area increasing beyond the electrode face, and if fastening straps are thinner than electrodes, contact area may be reduced. Electrodes may also move during sessions, or be placed inconsistently on different subjects. Between sites, reproducibility may be degraded because electrode shapes, types and placements are not consistent.
Knowledge of the exact distribution formed within the brain by the externally applied currents would clarify many study outcomes and most importantly allow more precise explorations of mechanism. Further, the effects of different current application protocols, electrode designs and study procedures could easily be resolved. Thus, a method for measuring current distributions formed by tDCS or tACS would answer many questions in this active field.
In the absence of methods for easily measuring or imaging current flow distributions, computational models have been used extensively to predict flow patterns. A large literature exists using computational models to explore effects of different montages, electrode areas and geometries on voltage distributions, electric fields or current flow. Increasingly sophisticated approaches have been devised to model the head subject to tDCS stimulation. As the field has grown, head model complexity has increased from spherical uniform, spherical four-compartment, realistic geometry, to high-resolution anisotropic models of the human head subject to electrical stimulation. This last category has involved merging source images based on MR images with diffusion-weighted images of the subject to predict white matter conductivity tensors. One approach to this uses water translational diffusion tensor eigenvectors to determine the direction of the conductivity tensor (assuming they are co-aligned) in combination with literature values of white matter conductivities. Another approach involves direct scaling of the white matter diffusion tensor to conductivity values. Most other model tissue conductivities are chosen from values measured on bulk tissues in the literature. However, to date no validation of these models has been possible in human subjects.
Some efforts have been made to measure current distributions resulting from tDCS. In a recent paper, Opitz et al. measured electric field distributions caused by transcranial stimulation via electrodes placed in a bilateral montage (left and right temples) using electrode arrays placed near the cortical surface of patients being monitored to identify epilepsy seizure foci. tACS was applied at 1-15 Hz with an intensity of 1 mA, and maximum electrical field strengths of 0.36 and 0.16 mV/mm were identified. A slight frequency dependent increase in conductivity (ca. 10%) was observed, and little capacitive effect. Again, these field strengths would not normally be sufficient to cause direct tissue stimulation, and support theories that slight depolarizations may be responsible for tDCS effects.
Researchers seeking to understand tES mechanisms have initiated fMRI studies to investigate the correlation of therapeutic current administration and brain activity as evidenced by changes in the BOLD contrast18-20. In the course of this research it has been noted that current administration creates artifacts on MR images. In another paper, fMRI analysis methods were used to find voxel clusters correlating with current flow features22. However, to date, there have been no attempts to non-invasively image tDCS or tACS current density distributions in humans directly.
The technique of Current Density Imaging (CDI) as suggested by Scott et al. (1991) is a method for translating the phase part of magnetic resonance images into individual magnetic flux density vector components caused by an externally applied current flow. These measurements can then be used to compute current density distributions using Ampere's law. The basic CDI technique requires the external current to be injected into subjects in concert with a sequence of RF pulses and gradient fields used to create MR images. The technique was demonstrated in phantoms and used to image current flow in a rabbit brain. Unfortunately, it is infeasible in humans because of the need to rotate the subject twice inside the scanner bore in order to obtain all three components of the magnetic flux density.
MR Electrical Impedance Tomography (MREIT) has been developed over the last decade as a method for imaging current density and conductivity distributions in the human body. As in CDI, MREIT requires current to be applied to a subject in conjunction with a particular MR sequence. However, MREIT methods make it possible to reconstruct conductivity, electric field and current density distributions in subjects by using only one component (Bz) of magnetic flux density vectors. A recently developed MREIT method, DT-MREIT, can be used to reconstruct full anisotropic conductivities and current density distributions using MREIT and DTI data gathered from the same subject, and has recently been demonstrated in canines.
In this work, the investigators will use MREIT methods to produce:
- Quantitative physical measures demonstrating tES reproducibility, exploring effects of current intensity, sex and neuroanatomic differences on measured current distributions.
- Comparisons of actual current density distributions developed in a target structure (DLPFC) with fMRI measures of activity.
These studies will provide the first tests of the assumptions that
- effects of tDCS stimulation are largest in the targeted region
- that the largest field and current flow is found in the targeted region These studies therefore have the potential to revolutionize understanding of tES mechanisms and practice.
This work has three aims, one focused on technical improvements in our present MREIT acquisition procedures, another targeted at quantifying replicability, measuring current flow distributions at different current intensities, and finally, in assessing correlations of electric field and current density distributions with brain activity measures using fMRI.
Specific Aim 1 (SA1) MREIT Pulse Sequence Acceleration and Improvements.
Specific Aim 2 (SA2) Replicability and Consistency in tDCS/tACS Protocols Current density distributions will be imaged in normal volunteers using an F3-F4 montage with three different current intensities, and repeat the measure at intervals of at least one week. Each time, the montage will be reapplied and subjects re-imaged. Both intra- and inter-subject variations in measured current and electric field distributions will be determined.
Specific Aim 3 (SA3) Correlation of functional measures with measured electrical distribution measures Participants' performance on a 2-back/0-back memory task will be compared in both Sham and Active subjects, using either 1, 1.5 or 2 mA intensity stimulation.
Study design
- Primary purpose
- Basic science
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind (participant)
- Number of arms
- 7
- Model description
- Structural (T1-weighted) and high angular resolution diffusion images of participant heads will be obtained. Current density distributions in normal participants will be imaged using an F3-F4 montage at three different current intensities. Measures will be repeated at intervals of at least one week. Each time, the montage will be reapplied and subjects re-imaged. Because the imaging method is quantitative, these measures will be used to provide an indication of baseline replicability. Both intra- and inter-subject variations in measured current and electric field distributions will be determined. Participant performance on a 3-back/0-back memory task will be compared in both Sham and Active subjects, using either 1, 1.5 or 2 mA intensity stimulation.
| Arm | Type | Receives |
|---|---|---|
| Current Intensity 1 mA | Active comparator | Device: tDCStDCS will be administered at an intensity of 1 mA to locations F3-F4, and fMRI response during performance of a 3-back/0-back memory task will be assessed. |
| Sham 1 mA | Sham comparator | Other: ShamDetermine fMRI response during performance of a 3-back/0-back memory task with sham 1 mA tDCS. |
| Current Intensity 1.5 mA | Active comparator | Device: tDCStDCS will be administered at an intensity of 1.5 mA to locations F3-F4, and fMRI response during performance of a 3-back/0-back memory task will be assessed. |
| Sham 1.5 mA | Sham comparator | Other: ShamDetermine fMRI response during performance of a 3-back/0-back memory task with sham 1.5 mA tDCS. |
| Current Intensity 2 mA | Active comparator | Device: tDCStDCS will be administered at an intensity of 2 mA to locations F3-F4, and fMRI response during performance of a 3-back/0-back memory task will be assessed. |
| Sham 2 mA | Sham comparator | Other: ShamDetermine fMRI response during performance of a 3-back/0-back memory task with sham 2 mA tDCS. |
| Structural, Diffusion and MREIT Imaging | Experimental | Device: tDCSStructural and High angular resolution diffusion weighted imaging will be performed. Magnetic Resonance Electrical Impedance Tomography imaging will be performed using electrode locations F3-F4. |
Who may qualify
- Ages
- 18 to 30 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult
Key inclusion criteria (2 listed)
- We will include neurologically normal volunteer subjects between 18-30 years of age in the study, minors will not be targeted.
- English as Native Language
Key exclusion criteria (13 listed)
- Adults who are unable to consent will not be included in the study.
- Pregnancy
- Subjects will not have any implanted or attached metallic devices.
- Appreciable deficits in hearing
- Appreciable problems with articulation
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| tDCSCurrent will be administered to subject groups as specified in arm descriptions. | Device | Current Intensity 1 mA, Current Intensity 1.5 mA, Current Intensity 2 mA, Structural, Diffusion and MREIT Imaging |
| ShamApparent Stimulation administered | Other | Sham 1 mA, Sham 1.5 mA, Sham 2 mA |
Primary outcome
Replicability
Time frame: 3 weeks
MREIT data will be obtained multiple times for each subject
Comparison of measured current distribution with fMRI result
Time frame: 2 weeks
Measured current distributions will be correlated with fMRI results and task accuracies
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 27 Jun 2022.
- Individual participant dataSharing planned: Yes. Data will be shared via the NIMH Data Archive (NDAR)
Related trials for Transcranial Direct Current Stimulation
Recruiting
Additional Effects on tDCS With AOT on Lower Limb Functions on Children With Diplegic CP
Diplegic Cerebral Palsy
Active, not recruiting
Improving Visual Field Deficits With Noninvasive Brain Stimulation
Visual Field Defect, Peripheral, Stroke
Enrolling by invitation
Brain Stimulation Paired With Structured Reading Instruction in Children With Dyslexia
Dyslexia, Reading Disability
Recruiting
Cumulative and Booster Effects of Multisession Prefrontal tDCS in ASD Adolescents
Transcranial Direct Current Stimulation, Autistic Spectrum Disorder
Enrolling by invitation
Brain Stimulation Paired With Structured Language Learning in Adults
Language Development, Learning
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Rosalind J Sadleir, PhD principal investigator
Arizona State University
2 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing tDCS in people with Transcranial Direct Current Stimulation, run by Arizona State University at 2 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 27 Jun 2022. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Replicability (time frame: 3 weeks). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Jun 2022.