AzTrials
AzTrials

Breast Cancer FemaleNCT03718442

Low Energy Dissection Vs. Electrocautery in Lumpectomy Shaved Surgical Margins

An observational study of Breast Cancer Female, run by Invuity, Inc..

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The purpose of this study is to compare the qualitative severity and depth of dissection devices' associated thermal artifact in breast lumpectomy shaved margins between the use of electrocautery and low thermal energy dissection, PhotonBlade. Read more about this study

Who is it for?
Ages 18 years and older, women only
Conditions the study is for
Breast Cancer Female
What is being tested?
PhotonBlade vs Bovie for lumpectomy shaved surgical margins
Type of treatment
Medical device
How many people
20 participants
Where
No sites listed yet
Study dates
15 Mar 2019to 15 Jun 2020
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • Women only
  • No healthy volunteers
  • Adult, Older adult

Study population: Women who have a diagnosis of breast cancer and undergo a lumpectomy

Who may be able to join

  • have aged 18 years old or older.
  • have DCIS or Invasive breast cancer that is eligible for breast-conserving surgery.
  • have not had previous chest radiotherapy.
  • understand the study purpose, requirements, and risks.
  • able and willing to give informed consent.

Who cannot join

  • None

Trial locations and contacts

No sites are listed yet.

Dennise D Dalma-Weiszhausz, PhD contact

6502486662

ddalma@invuity.com

About this study

Official title: Low Energy Dissection Vs. Electrocautery Qualitative Severity and Depth of Thermal Artifact in Breast Cancer Lumpectomy Shaved Surgical Margins

The purpose of this study is to compare the qualitative severity and depth of dissection devices' associated thermal artifact in breast lumpectomy shaved margins between the use of electrocautery and low thermal energy dissection, PhotonBlade.

The investigators hypothesize that the use of PhotonBlade would result in a significantly lower qualitative severity and a shorter depth of thermal artifact in breast lumpectomies shaved margins, when compared to electrocautery devices.

Read the detailed description

When performing lumpectomy, surgeons have used electrocautery devices as dissecting tools. However, those devices use high thermal energy that might impact the margin cellular architecture and as such the quality of margin assessment by the pathologist. Moreover, recently, modern low thermal energy dissection devices have been introduced to the market. However, the impact of those devices on reducing the thermal injury/artifact on surgical margin has not been well investigated. 4,5 While Ruidaz et al. 2011 data suggest that using the traditional electrosurgical device in place of the low thermal-injury device results in 48% of the close margin samples being negatively converted to false-positive, and in 11% converting from close to false-negative, there is still a need for more studies to further characterize the utility of those devices. 6 PhotonBlade (Invuity, San Francisco, CA, USA) has been approved by United States Food and Drug Administration (FDA). PhotonBlade is a dynamic precision illuminator with enhanced energy delivery dissection device. The dynamic precision illumination is a thermally cool illumination technology that allows a uniformal illumination without glare or shadow. 7 The enhanced energy delivery technology allows low thermal spread, surgeon controlled edge temperature, and wet field use.7 As such, PhontonBlade allows better blade control for achieving adequate visualization, hemostasis, with a minimum collateral damage to the surgical margin tissue. The use of PhotonBlade demonstrated the least penetrating thermal tissue damage/spread when compared to other modern dissection devices (Valleylab Pencil, Valleylab EDGE Coated Pencil, PlasmaBlade 3.0S and PlasmaBlade 4.0).8

Being tested
PhotonBlade vs Bovie for lumpectomy shaved surgical margins

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • PhotonBlade vs Bovie for lumpectomy shaved surgical marginsDevice

    For each enrolled patient, six shaved margins will be obtained (superior, inferior, medial, lateral, anterior, and posterior). For each patient, electrocautery will be used to obtain 3 of the shaved margins, and PhotonBlade to obtain the other 3 shaved margins. Once the lumpectomy site shaved margins have been obtained, the shaved surgical margins will be evaluated by a pathologist whom is blinded in regards to the dissection device that was used for each margin. The pathologist will be evaluating each shaved margin and reporting the outcomes (qualitative severity and depth of thermal artifact)

Study groups in NCT03718442
Study groupRoleWhat they receive
Breast cancer patients - lumpectomyWomen who are 18 years or older, have Ductal carcinoma in situ (DCIS) or invasive breast-conserving surgery, have not had previous chest radiotherapy. 20 patients who meet above study population criteria will be enrolled in this study.Shaved margins for each lumpectomy site will be excised with either Bovie (3 sides) or PhotonBlade (3 sides) for each patient. The effect of PhotonBlade vs Bovie on pathology assessment of lumpectomy shaved surgical margins will be compared.
Receives: Device: PhotonBlade vs Bovie for lumpectomy shaved surgical margins

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Severity of thermal artifact

    The severity of the thermal artifact will be assessed by identifying the presence or absence of each the three qualitative severity zones, described previously,6 as below:

    • Zone I: extensive charring tissue
    • Zone II: fused cellular architecture
    • Zone III: distressed cellular architecture

    Measured: Through study completion, an average of 6 months

  2. Depth of thermal artifact

    The depth of the thermal artifact will be assessed by reporting the length in micrometer (μm) from the start of Zone 1 to the end of Zone III.

    Measured: Through study completion, an average of 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Oct 2018
  2. Study start15 Mar 2019 (estimated)
  3. Primary completion15 Dec 2019 (estimated)
  4. Study completion15 Jun 2020 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
20 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03718442
Sponsor's protocol ID
2018-8984
Status last verified
Oct 2018
First submitted
18 Oct 2018
Last updated
24 Oct 2018
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
Undecided: No plan in place at this time.

Publications

  • ACS. Breast Cancer Facts and Figures 2011-2012. (2012).

  • Vila J, Gandini S, Gentilini O. Overall survival according to type of surgery in young (</=40 years) early breast cancer patients: A systematic meta-analysis comparing breast-conserving surgery versus mastectomy. Breast. 2015 Jun;24(3):175-81. doi: 10.1016/j.breast.2015.02.002. Epub 2015 Feb 23.

    PubMed 25728282
  • Pleijhuis RG, Graafland M, de Vries J, Bart J, de Jong JS, van Dam GM. Obtaining adequate surgical margins in breast-conserving therapy for patients with early-stage breast cancer: current modalities and future directions. Ann Surg Oncol. 2009 Oct;16(10):2717-30. doi: 10.1245/s10434-009-0609-z. Epub 2009 Jul 17.

    PubMed 19609829
  • Chiappa C, Rovera F, Corben AD, Fachinetti A, De Berardinis V, Marchionini V, Rausei S, Boni L, Dionigi G, Dionigi R. Surgical margins in breast conservation. Int J Surg. 2013;11 Suppl 1:S69-72. doi: 10.1016/S1743-9191(13)60021-7.

    PubMed 24380558
  • Ruidiaz ME, Cortes-Mateos MJ, Sandoval S, Martin DT, Wang-Rodriguez J, Hasteh F, Wallace A, Vose JG, Kummel AC, Blair SL. Quantitative comparison of surgical margin histology following excision with traditional electrosurgery and a low-thermal-injury dissection device. J Surg Oncol. 2011 Dec;104(7):746-54. doi: 10.1002/jso.22012. Epub 2011 Jul 8.

    PubMed 21744349
  • Haydon E. et al. Assessment of penetrating thermal tissue damage/spread associated with PhotonBlade™, Valleylab™ Pencil, Valleylab™ EDGE™ Coated Pencil, PlasmaBlade® 3.0S and PlasmaBlade® 4.0 for intraoperative tissue dissection using the fresh extirpated porcine muscle model

Questions about this trial

What is this clinical trial studying?

An observational study of Breast Cancer Female, run by Invuity, Inc..

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 24 Oct 2018. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Dennise D Dalma-Weiszhausz, PhD (6502486662, ddalma@invuity.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Severity of thermal artifact (time frame: Through study completion, an average of 6 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03718442, which also lists 6 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Oct 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in