AzTrials
AzTrials

Guided Surgery AccuracyNCT03641365

Sleeves Versus Sleeveless Template

A study testing Test group in people with Guided Surgery Accuracy and Dental Implant Failed, run by Osstem AIC at 1 site in Italy.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

To compare virtual planning accuracy of computer-assisted template-based implant placement using CAD/CAM stereolithographic surgical templates with or without metallic sleeves.Furthermore to compare open versus closed holes in case of sleeveless templates. Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
What is being tested?
Test group
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteItaly
Study dates
1 Sep 2017to 30 May 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Partially edentulous patient
  • Aged 18 years or older
  • Able to sign an informed consent
  • In need of an implant-supported fixed restoration

Who cannot join

  • General medical contraindication to oral surgery (American Society of Anesthesiologist, ASA, class III or IV) including uncontrolled diabetes
  • Irradiation in the head and neck area less than one year before implantation
  • Psychiatric problems
  • Alcohol or drug abuse
  • Pregnant or nursing
  • Untreated periodontitis or poor oral hygiene and motivation
  • Severe bruxism or clenching
  • Inability to complete the follow-up.

Trial locations and contacts

1 site in 1 country.

Italy1 site
  • Studio Odontoiatrico Marco Tallarico

    Rome, 00151

Other trials in Italy

About this study

Official title: Accuracy of Computer-assisted Template-based Implant Placement Using CAD/CAM Stereolithographic Surgical Templates With or Without Metallic Sleeves: a Randomized Controlled Trial

To compare virtual planning accuracy of computer-assisted template-based implant placement using CAD/CAM stereolithographic surgical templates with or without metallic sleeves.Furthermore to compare open versus closed holes in case of sleeveless templates.

Any partially edentulous patients requiring at least one implant to be planed according to a computer-assisted template-based protocol were enrolled. Patients were randomised according to a parallel group design into two arms: surgical template with or without metallic sleeves. Three deviation parameters (angular, horizontal, vertical) were defined to evaluate the discrepancy between the planned and placed implant positions.

Read the detailed description

This study was designed as a randomized controlled trial of parallel group design conducted at one centre, between May 2016 and March 2017. The study was performed after approval was received from the institutional review board of the Aldent University, Tirana, Albania (2/2017).

The investigation was conducted according to the principles embodied in the Helsinki Declaration of 1975 for biomedical research involving human subjects, as revised in 2013. All patients were informed about the nature of the treatment and their written consent was obtained. Data collection was designed to preserve patient anonymity.

  • Inclusion/exclusion criteria:

Any partially edentulous patient, aged 18 years or older, able to sign an informed consent, in need of an implant-supported fixed restoration was considered eligible for this study. Any potential implant location based on individual patient requirements was considered eligible in the present trial. Patients were not admitted to the study if any of the following exclusion criteria was present: general medical contraindication to oral surgery (American Society of Anesthesiologist, ASA, class III or IV); irradiation in the head and neck area less than one year before implantation; psychiatric problems; alcohol or drug abuse; pregnant or nursing; untreated periodontitis; severe bruxism or clenching; uncontrolled diabetes; poor oral hygiene and motivation; and inability to complete the follow-up.

Enrolled patients received preoperative photographs, periapical radiographs or panoramic x-rays for initial screening and evaluation. The prosthetic-driven planning workflow started by taking a cone beam computed tomography (CBCT) scan (Cranex 3Dx, Soredex, Tuusula, Finland) by using a wax bite to separate dental arches. Then, the patients received intraoral digital impression taken using the 3M True Definition Scanner (3M Italia, Pioltello, Milano). The digital data (STL, STereo Lithography interface format) was imported in a 3D design software (exocad DentalCAD, Exocad GmbH, Darmstadt, Germany) to realize a virtual wax-up according to the functional and esthetic requirements. Then, the STL and DICOM (Digital Imaging and COmmunications in Medicine) data were imported in a 3D software planning program (3Diagnosys ver. 5.0, 3DIEMME srl, Cantù, Italy). Then, the reprocessed surface extrapolated from the DICOM data (by using a Hounsfield scale filter) and the surface generated by the master cast scanning process, or by the intraoral scanning process, were merged with the best-fitting repositioning tools of the software (3Diagnosys ver. 5.0, 3DIEMME srl). At this point, prosthetic-driven implants/abutments size and location were planned taking into account the bone quality and quantity, soft tissue thickness, anatomical landmarks, as well as, type, volume and shape of the final restoration. After careful functional and esthetic evaluation and final verification, the prosthetic-driven plan was approved. At this point, patients were randomly assigned to receive conventional stereolithographic surgical template with (control group) or without (test group) metallic sleeves. Stereolithographic surgical templates were designed and fabricated by an independent certified center not previously involved in the study (New Ancorvis srl, Bargellino, Italy). In the test group, conventional templates with close-sleeve-design were produced to place implants between premolars. In case of implants to be place in molar area, template with open sites were produced to solve intermaxillary space limits.

  • Surgical protocol:

One hour before implant placement, all patients underwent professional oral hygiene, prophylactic antiseptic with 0.2% chlorhexidine (Curasept, Curaden Healthcare, Saronno, Italy) for one minute, and prophylactic antibiotic therapy (2 g of amoxicillin or clindamycin 600 mg if allergic to penicillin). The fit of the surgical templates were accurately tried in the patient mouth to achieve a stable fit (Fit Checker, GC - Tokyo, Japan). All patients were treated under local anesthesia using articaine with adrenaline 1:100000 administered 20 minute before surgery. The surgical templates were stabilized on the residual teeth and fixed with two to three preplanned anchor pins.Hopeless teeth were extracted at the end of the intervention in order to improve the stability of the surgical template and to provide more reference point for measurements of the implant accuracy. Nevertheless, in case of immediate postextractive implants, residual teeth were extracted as atraumatically as possible immediately before surgery. In the test group, planned implants (Osstem TSIII, Osstem, Seoul, South Korea) were placed flapless using dedicate drills (OneGuide Kit, Osstem) in combination with a sleeveless surgical guide. In this case the drills were used directly thought the sleeve-designed template without metallic tubs and with not the need of drill reductions. In the control group, planned implants (Osstem TSIII, Osstem, Seoul, South Korea) were placed flapless using dedicate drills (OsstemGuide Kit[Taper], Osstem) in combination with reduction tools, within the surgical templates containing metallic sleeves. If the keratinized gingiva and the amount of bone were adequate, the implants were placed flapless. Otherwise, a flap was elevated and then the wound was closed with single-stitch sutures using 4.0 resorbable suture material (Vicryl, Ethicon J\&J International, Sint-Stevens-Woluwe, Belgium). Implant site were prepared based on the bone density evaluated by the surgeon at the first drill. All the implant were inserted according to a one-stage protocol, with an insertion torque ranging from 35 to 45 Ncm. In case of poor bone density, the implant site was underprepared. Immediately after implant placement, patients of both groups receive a digital impression (3M True Definition Scanner, 3M Italia, Pioltello, Milano) taken at implant level using a dedicate abutments (Scan body type AQ, New Ancorvis srl), to check the position of the placed implants.

Following implant placement, all patients received oral and written recommendations about medication, oral hygiene maintenance and diet. Implants were loaded after 8 to 12 weeks of healing. Then, patients were followed twice a year for hygiene maintenance and occlusal control.

  • Outcome measurements:
  • Implant failure: an implant was considered to be a failure if it was lost for mobility, implant fracture and/or any infection dictating implant removal. The stability of each individual implant was measured manually with a torque of 20 Ncm at delivery of the final restoration and later, with the prosthesis removed, if needed (infection, extensive peri-apical bone loss, mucosal inflammation).
  • Template-related complications: early surgical complications involved the surgical template comprised limited access in posterior areas, buccal bony dehiscence (due to a mismatching of the surgical template) evaluated sounding the implant site with a periodontal probe (PCPUNC156, Hu-Friedy Italy, Milan, Italy) before implant placement, insertion of different implant than planned, and fracture of surgical template. All the complications were recorded during follow-up by the same clinician (Marco Tallarico), who performed all the surgical procedures.
  • Accuracy: Three deviation parameters (horizontal, vertical, and angular) were defined and calculated between the planned and placed implant positions. The post-operative STL file, derived from the intraoral scan, was geometrically aligned with the files exported from the planning, by automated image registration using maximization of mutual information (Dental SCAN, ver.6, Open Technologies srl, Brescia, Italy). The horizontal (lateral), vertical (depth) and angular deviation between virtual and placed implants were calculated along the long axis of each implants. An expert blinded mechanical engineer (FC) performed all the measurements.
  • Randomization:

One computer-generated restricted randomization list was created. Only one of the investigators, not involved in the selection and treatment of the patients, was aware of the random sequence and could have access to the randomization lists stored in a password-protected portable computer. The random codes were enclosed in sequentially numbered, identical, opaque, sealed envelopes. Envelopes were opened sequentially after the prosthetic-driven plan was approved.

  • Statistical analysis:

Patient data were collected in a Numbers spreadsheet (Version 3.6.1 for Mac OS X 10.11.4). A bio-statistician with expertise in dentistry analyzed the data using SPSS software for Mac OS X (version 22.0; SPSS Inc., Chicago, IL, USA) for statistical analysis. Descriptive analysis was performed for numeric parameters using mean±standard deviation and median with confidence interval (95% CI). Implant failure and template-related complications between the two groups were compared using Fisher's exact probability test. The mean differences of the overall deviation in the clinical outcomes compared to the virtual plan, were compared between groups using a mixed-model repeated-measures analysis of variance (ANOVA). In the sleeve-less group, accuracy of open versus closed holes were also evaluated. All statistical comparisons were conducted with a P value set at 0.05.

Being tested
Test group, Control group
Keywords
Intraoral scanner, Guided surgery, Implant accuracy, Dental implants

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Test groupDevice

    Also called Sleeveless Template

    Guided Implant placement Positioning/placement of dental implants thought the fully acrylic surgical template without metallic sleeves.

  • Control groupDevice

    Also called Conventional Template

    Guided Implant placement Positioning/placement of dental implants thought the acrylic surgical template with metallic sleeves.

Study groups in NCT03641365
Study groupRoleWhat they receive
Test groupExperimentalTest group: Surgical template without metallic sleeves. In this case the surgical template has all been designed and fabricated in acrylic material by mean of stereolitographic technology.
Receives: Device: Test group
Control groupActive comparatorControl group: Surgical template with metallic sleeves. Surgical template has designed and fabricated in acrylic material by mean of stereolitographic technology and metallic sleeves have been bonded after its production.
Receives: Device: Control group

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy (discrepancy between virtual implant planning and placed implants)

    Three deviation parameters (horizontal, vertical, and angular) were defined and calculated between the planned and placed implant positions. The post-operative STL file, derived from the intraoral scan, was geometrically aligned with the files exported from the planning, by automated image registration using maximization of mutual information (Dental SCAN, ver.6, Open Technologies srl, Brescia, Italy). The horizontal (lateral), vertical (depth) and angular deviation between virtual and placed implants were calculated along the long axis of each implants. An expert blinded mechanical engineer (FC) performed all the measurements.

    Measured: Implant placement (baseline)

Secondary outcomes (2)
  1. Implant failure

    An implant was considered to be a failure if it was lost for mobility, implant fracture and/or any infection dictating implant removal. The stability of each individual implant was measured manually with a torque of 20 Ncm at delivery of the final restoration and later, with the prosthesis removed, if needed (infection, extensive peri-apical bone loss, mucosal inflammation).

    Measured: 4 months after implant placement (baseline)

  2. Template-related complications

    Early surgical complications involved the surgical template comprised limited access in posterior areas, buccal bony dehiscence (due to a mismatching of the surgical template) evaluated sounding the implant site with a periodontal probe (PCPUNC156, Hu-Friedy Italy, Milan, Italy) before implant placement, insertion of different implant than planned, and fracture of surgical template.

    Measured: Implant placement

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Aug 2018
  2. Study start1 Sep 2017
  3. Primary completion30 May 2018
  4. Study completion30 May 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Parallel groups
Model description
Randomized controlled trial of parallel group design conducted at one centre.
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03641365
Sponsor's protocol ID
Osstem_001
Status last verified
Aug 2018
First submitted
15 Aug 2018
Last updated
27 Aug 2018
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • D'haese J, Van De Velde T, Elaut L, De Bruyn H. A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae. Clin Implant Dent Relat Res. 2012 Apr;14(2):293-303. doi: 10.1111/j.1708-8208.2009.00255.x. Epub 2009 Nov 10.

    PubMed 19906267
  • D'haese J, Ackhurst J, Wismeijer D, De Bruyn H, Tahmaseb A. Current state of the art of computer-guided implant surgery. Periodontol 2000. 2017 Feb;73(1):121-133. doi: 10.1111/prd.12175.

    PubMed 28000275
  • Tallarico M, Esposito M, Xhanari E, Caneva M, Meloni SM. Computer-guided vs freehand placement of immediately loaded dental implants: 5-year postloading results of a randomised controlled trial. Eur J Oral Implantol. 2018;11(2):203-213.

    PubMed 29806667

Questions about this trial

What is this clinical trial studying?

A study testing Test group in people with Guided Surgery Accuracy and Dental Implant Failed, run by Osstem AIC at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 27 Aug 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy (discrepancy between virtual implant planning and placed implants) (time frame: Implant placement (baseline)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03641365, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Aug 2018.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in