AzTrials
AzTrials

Mandibular FracturesNCT03608891

Patient Specific Plates Versus Conventional Miniplates for Treatment of Mandibular Body Fractures

A study testing Computer guided patient specific 3D titanium plate and Conventional titanium miniplates in people with Mandibular Fractures, run by Cairo University.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The aim of the current study is to evaluate and assess the clinical stability and efficacy of patient specific computer guided titanium plates versus the conventional titanium mini plates regarding accurate reduction and fixation of mandibular body fractures, reducing the operating time, achieving precise bone… Read more about this study

Who is it for?
Ages 18 to 60 yearsHealthy volunteers can take part
Conditions the study is for
Mandibular Fractures
What is being tested?
Computer guided patient specific 3D titanium plate and Conventional titanium miniplates
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
No sites listed yet
Study dates
Jul 2018to Jul 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 60 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Patients with unilateral mandibular body fractures, not associated with other mandibular and maxillofacial fractures

Who cannot join

  • Patients with bilateral mandibular fractures
  • Patients with other mandibular or maxillofacial fractures
  • Comminuted fractures
  • Medical problem that may interfere with the procedure such as bleeding disorder and pregnancy.

Trial locations and contacts

No sites are listed yet.

Dina A Alei El Dine, Postgraduate contact

01285568850

dinaadelta3lab@gmail.com

About this study

Official title: Patient Specific Three-Dimensional Titanium Plates Versus Conventional Miniplates for Treatment of Mandibular Body Fractures. (Randomized Clinical Trial)

The aim of the current study is to evaluate and assess the clinical stability and efficacy of patient specific computer guided titanium plates versus the conventional titanium mini plates regarding accurate reduction and fixation of mandibular body fractures, reducing the operating time, achieving precise bone alignment and reducing the plate palpability.

Read the detailed description

The study will be conducted on two groups:

Intervention group: patient specific three-dimensional titanium plates CBCT or CT scan will be performed for the patient, the dicom files will be imported into a surgical planning software , plates will then be designed virtually and sent for three-dimensional (3D) printing.

Control group: Conventional miniplates:

In this group two miniplates of titanium Mini-System 2.0 mm will be used. The plate has profile height 1.0 mm whereas the screw length varies according to the site of the plate. According to Champy osteosynthesis lines for fixation of the posterior mandibular fracture ,the first plate will be placed at the inferior border from the buccal side, using bicortical screws engaging the buccal and lingual cortices to achieve rigid fixation, while the second plate will be placed at about 5mm superior to the inferior plate in the subapical region, using monocortical screws engaging only the buccal cortex to avoid injuring the teeth roots.

Being tested
Computer guided patient specific 3D titanium plate, Conventional titanium miniplates
Medical subject headings
Mandibular Fractures

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Computer guided patient specific 3D titanium plateDevice

    Also called Intervention Arm

    CBCT or CT scan will be done preoperatively and dicom files will be imported to mimics software to design and print the patient specific 3D titanium plate.

  • Conventional titanium miniplatesDevice

    Also called Control arm

    In this group two miniplates of titanium Mini-System 2.0 mm will be used. The plate has profile height 1.0 mm whereas the screw length varies according to the site of the plate. According to Champy osteosynthesis lines for fixation of the posterior mandibular fracture ,the first plate will be placed at the inferior border from the buccal side, using bicortical screws engaging the buccal and lingual cortices to achieve rigid fixation, while the second plate will be placed at about 5mm superior to the inferior plate in the subapical region, using monocortical screws engaging only the buccal cortex to avoid injuring the teeth roots.

Study groups in NCT03608891
Study groupRoleWhat they receive
Control ArmActive comparatorConventional titanium miniplates
Receives: Device: Conventional titanium miniplates
Intervention armExperimentalPatient specific 3D plates
Receives: Device: Computer guided patient specific 3D titanium plate

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Patient Satisfaction measured with visual analogue scale (0-10)

    patient satisfaction is defined as patient-reported outcome measure while the structures and processes of care can be measured by patient-reported experiences (30). Measured on a visual analogue scale (VAS) (29) of 0-10 ,with zero being unsatisfied and 10 being satisfied. Patient Satisfaction is assessed regarding prescence of pain, occlusal discrepencies and overall patient satisfaction.

    Measured: Measured immediately after the surgery

Secondary outcomes (4)
  1. Fracture gap distance

    This is done using CBCT through measuring the fracture gap distance in millimeters to evaluate proper reduction and fixation

    Measured: 0 and 3 months

  2. Occlusal bite force

    The biting force will be measured through the follow up visits (1 week,3 months) by the bite force recorder at the incisor region, right and left molar region. The measurement of the bite force will be undertaken using a portable type of occlusal force gauge (GM10, Nagano Keiki, Japan) called OCCLUSAL FORCE-METER GM10. (36)

    Measured: 0 and 3 months

  3. Operating time

    The time of the surgery will be recorded using a stopwatch.

    Measured: time of the surgery

  4. Plate palpability

    Measured during all follow up visits, by questioning the patient ,where the patient will be informed of the site of the plates ,and asked if he feels the plates are palpable ,and will be measured by binary measuring unit (yes/no) , also the plates will be palpated by the operator at follow up visits.

    Measured: 0 and 3 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Aug 2018
  2. Study startJul 2018 (estimated)
  3. Primary completionFeb 2019 (estimated)
  4. Study completionJul 2019 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
20 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03608891
Sponsor's protocol ID
Patient specific plate
Status last verified
Jul 2018
First submitted
10 Jul 2018
Last updated
1 Aug 2018
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Perez R, Oeltjen JC, Thaller SR. A review of mandibular angle fractures. Craniomaxillofac Trauma Reconstr. 2011 Jun;4(2):69-72. doi: 10.1055/s-0031-1272903.

    PubMed 22655117
  • Goiato MC, Santos MR, Pesqueira AA, Moreno A, dos Santos DM, Haddad MF. Prototyping for surgical and prosthetic treatment. J Craniofac Surg. 2011 May;22(3):914-7. doi: 10.1097/SCS.0b013e31820f7f90.

    PubMed 21558926
  • Levine JP, Patel A, Saadeh PB, Hirsch DL. Computer-aided design and manufacturing in craniomaxillofacial surgery: the new state of the art. J Craniofac Surg. 2012 Jan;23(1):288-93. doi: 10.1097/SCS.0b013e318241ba92.

    PubMed 22337427
  • Talwar RM, Chemaly D. Information and computer technology in oral and maxillofacial surgery. Oral Maxillofac Surg Clin North Am. 2008 Feb;20(1):79-89. doi: 10.1016/j.coms.2007.09.006.

    PubMed 18194740
  • Edwards SP. Computer-assisted craniomaxillofacial surgery. Oral Maxillofac Surg Clin North Am. 2010 Feb;22(1):117-34. doi: 10.1016/j.coms.2009.11.005.

    PubMed 20159482
  • Hassfeld S, Muhling J. Computer assisted oral and maxillofacial surgery--a review and an assessment of technology. Int J Oral Maxillofac Surg. 2001 Feb;30(1):2-13. doi: 10.1054/ijom.2000.0024.

    PubMed 11289616
  • Eckardt A, Swennen GR. Virtual planning of composite mandibular reconstruction with free fibula bone graft. J Craniofac Surg. 2005 Nov;16(6):1137-40. doi: 10.1097/01.scs.0000186306.32042.96.

    PubMed 16327572
  • Bell RB. Computer planning and intraoperative navigation in cranio-maxillofacial surgery. Oral Maxillofac Surg Clin North Am. 2010 Feb;22(1):135-56. doi: 10.1016/j.coms.2009.10.010.

    PubMed 20159483
  • Al-Abri R, Al-Balushi A. Patient satisfaction survey as a tool towards quality improvement. Oman Med J. 2014 Jan;29(1):3-7. doi: 10.5001/omj.2014.02.

    PubMed 24501659
  • Butts SC, Floyd E, Lai E, Rosenfeld RM, Doerr T. Reporting of Postoperative Pain Management Protocols in Randomized Clinical Trials of Mandibular Fracture Repair: A Systematic Review. JAMA Facial Plast Surg. 2015 Nov-Dec;17(6):440-8. doi: 10.1001/jamafacial.2015.1011.

    PubMed 26335408
  • Kumar ST, Saraf S, Devi SP. Evaluation of bite force after open reduction and internal fixation using microplates. J Dent (Tehran). 2013 Sep;10(5):466-77. Epub 2013 Sep 30.

    PubMed 24910656
  • Rodt T, Bartling SO, Zajaczek JE, Vafa MA, Kapapa T, Majdani O, Krauss JK, Zumkeller M, Matthies H, Becker H, Kaminsky J. Evaluation of surface and volume rendering in 3D-CT of facial fractures. Dentomaxillofac Radiol. 2006 Jul;35(4):227-31. doi: 10.1259/dmfr/22989395.

    PubMed 16798916
  • Manson PN, Markowitz B, Mirvis S, Dunham M, Yaremchuk M. Toward CT-based facial fracture treatment. Plast Reconstr Surg. 1990 Feb;85(2):202-12; discussion 213-4.

    PubMed 2300626

Questions about this trial

What is this clinical trial studying?

A study testing Computer guided patient specific 3D titanium plate and Conventional titanium miniplates in people with Mandibular Fractures, run by Cairo University.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 1 Aug 2018. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Dina A Alei El Dine, Postgraduate (01285568850, dinaadelta3lab@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Patient Satisfaction measured with visual analogue scale (0-10) (time frame: Measured immediately after the surgery). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03608891, which also lists 13 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Aug 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in