AzTrials
AzTrials

Respiration; Insufficient or Poor, NewbornToNILNCT03586856

Comparison of Leakage With Nasal Prongs and Nasal Mask Interface in Newborns Receiving CPAP Treatment

A study testing Nasal mask interface and Nasal prongs interface in people with Respiration; Insufficient or Poor, Newborn and Infant,Premature, run by Baldvin Jonsson at 2 sites in Sweden.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The study is a two-armed randomized cross-over comparison of leakage with nasal prongs and nasal mask interface in newborn infants treated with CPAP, born after 28 weeks of gestational age. Read more about this study

Who is it for?
Ages Up to 44 weeks
What is being tested?
Nasal mask interface and Nasal prongs interface
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
50 participants
Where
2 sitesSweden
Study dates
1 Aug 2018to 26 Oct 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Up to 44 weeks
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • Gestational age over 28 weeks (corrected age) at the time of inclusion
  • Patient receiving respiratory support with CPAP

Who cannot join

  • Airway, pulmonary, cardiac or gastro-intestinal malformations
  • Neuromuscular disease
  • Circulatory unstable patient
  • FiO2 higher than 0.5
  • Nasal damage or major skin irritation.
  • Extubation less than 24 h before investigation
  • Surgery less than 5 days before investigation

Trial locations and contacts

2 sites in 1 country.

Sweden2 sites
  • Östersund hospital

    Östersund, Jämtland County, 83143

  • Karolinska University Hospital, Neonatology department

    Stockholm, 171 76

Other trials in Sweden

About this study

Official title: Trial of NCPAP Interface Leakage (ToNIL): A Randomised Crossover Comparison of Leakage With Nasal Prongs and Nasal Mask Interface in Newborn Infants Treated With CPAP

The study is a two-armed randomized cross-over comparison of leakage with nasal prongs and nasal mask interface in newborn infants treated with CPAP, born after 28 weeks of gestational age. For infants with an interface leakage, the trial also includes an observational part evaluating simple measures to reduce leakage.

The study will be carried out in the Karolinska University Hospital Stockholm and in the Östersund Hospital.

Read the detailed description

The study will recruit a total of 50 infants receiving CPAP for respiratory support at the Karolinska University Hospital and the Östersund Hospital. The infant should be stable and not in major respiratory distress. Consent from the parents will be obtained before enrolment.

The included infants should have stable spontaneous breathing and be older than 28 weeks (corrected age) at the time of enrolment. The reason for respiratory failure and CPAP treatment is not relevant for study purposes. If an infant cannot participate in the study at a given time, he or she can be enrolled later. A child can only participate once.

The primary outcome is leakage. This is recorded using equipment for measuring air flow during CPAP treatment. Measurement of leakage is first performed for one interface and then the next (cross-over). The interface order is randomized. The leakage will be measured after a few minutes of stabilization (part 1). If there is leakage, a few simple measures to reduce the leakage will be evaluated (part 2). The second part will approximately add 10-20 minutes and includes simple measures such as adjusting the nasal mask, closing the mouth, changing the position or changing the size of nasal mask/prongs. Part 1 and part 2 are then repeated for the next interface. If the child shows signs of distress or agitation the measurement will be paused or stopped.

Part 1: The CPAP system with the randomized interface (nasal mask or nasal prongs) is applied and adjusted by experienced NICU staff. The staff is blinded for the outcome variable, leakage. The choice of size and other adjustments are guided by clinical experience and not by protocol. The NICU staff is not allowed to participate in the explorative part where measures to reduce leakage are evaluated. This precaution is to avoid staff learning what adjustments affect leakage and influence care of infants enrolled at a later stage.

Part 2: In this part the investigators can evaluate the effect of simple measures to minimize the leakage. The level of leakage is displayed on a screen. Examples of measures are; closing the mouth of the infant, adjusting straps, adjusting position and changing the size of the interface. Not every child will undergo all measures to reduce leakage, since the aim of this explorative part is to explore ways to reduce leakage.

It is estimated that these tests and measures will take 15-60 minutes per child. No other measurements or follow-up is planned. No blood samples will be collected or analysed.

The study will collect information on the infant and the birth. This includes birth weight, gestational age at birth, gender, previous respiratory support and medical history.

The main outcome variable is absolute leakage (via mouth or via CPAP interface). Other collected variables are oxygen saturation, respiratory rate, inspired oxygen concentration, apneas, heart rate, if the infant is awake/asleep or in distress. Safety variables include skin irritation or damage of the nose caused by the interface, instability or deterioration of respiration or circulation, problems with the equipment or other adverse events. The investigation can be stopped immediately in the case of distress or instability. The study is, as far as the investigators know, the first one of its kind. The air flow meters do not affect the CPAP system and use a technique that measures the total leakage in L/min. These improvements have been emphasized in previous studies. The study follows GCP (good clinical practice) standards and The Helsinki declaration.

Being tested
Nasal mask interface, Nasal prongs interface
Keywords
Continuous positive airway pressure, Air Leakage, Work of breathing
Medical subject headings
Respiratory Aspiration, Premature Birth

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Nasal mask interfaceDevice

    Nasal masks is a standard interface used for CPAP treatment of newborn infants. The CPAP device allows for easily switching between the nasal prongs or nasal mask interface as well as adjustment of size.

  • Nasal prongs interfaceDevice

    Nasal masks is a standard interface used for CPAP treatment of newborn infants. The CPAP device allows for easily switching between the nasal prongs or nasal mask interface as well as adjustment of size.

Study groups in NCT03586856
Study groupRoleWhat they receive
Nasal mask interfaceActive comparatorThe CPAP interface will be applied and adjusted by experienced staff blinded to the outcome variable; leakage. Measures to reduce/minimize leakage are tested in an unblinded observational part after the intervention.
Receives: Device: Nasal mask interface
Nasal prongs interfaceActive comparatorThe CPAP interface will be applied and adjusted by experienced staff blinded to the outcome variable; leakage. Measures to reduce/minimize leakage are tested in an unblinded observational part after the intervention.
Receives: Device: Nasal prongs interface

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Leakage in the CPAP system

    Measurement of absolute leakage (at interface or mouth) using flowmeters connected to the CPAP device in flow through position (L/min, 30 seconds recording)

    Measured: 0-60 min

Secondary outcomes (5)
  1. Inspired oxygen level (FiO2)

    FiO2 level and adjustments needed to maintain pre-intervention baseline peripheral oxygen saturation (SpO2 target range according to local guidelines)

    Measured: 0-60 min

  2. Level of CPAP support (cmH2O)

    CPAP level and adjustments needed to maintain pre-intervention baseline peripheral oxygen saturation (SpO2 target range according to local guidelines)

    Measured: 0-60 min

  3. Peripheral oxygen saturation (SpO2)

    Deviations from baseline and changes requiring adjustment of respiratory support (Outcome 2 and 3)

    Measured: 0-60 min

  4. Measurement completion possible (yes/no)

    The number of infants (ratio of total included patients) where measurement of leakage could be determined (on first or more attempts)

    Measured: 0-60 min

  5. Effect of simple measures to reduce leakage (L/min)

    Lowest level of recorded level of leakage obtainable using simple measures to reduce leakage, guided by leakage monitoring equipment (L/min and measures used to achieve reduction)

    Measured: 0-60 min

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 Jul 2018
  2. Study start1 Aug 2018
  3. Primary completion26 Oct 2019
  4. Study completion26 Oct 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Model description
Main study design: Two armed randomized cross-over comparison of leakage for two interfaces. The trial also investigates simple measures to reduce leakage (observational)
Masking
None (open label)
Enrolment
50 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03586856
Sponsor's protocol ID
2016/2449-31
Acronym
ToNIL
Status last verified
Nov 2019
First submitted
4 Jun 2018
Last updated
13 Nov 2019
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Publications

  • Gunnarsdottir K, Falk M, Baldursdottir S, Donaldsson S, Jonsson B, Drevhammar T. Do newborn infants exhale through the CPAP system? Secondary analysis of a randomised cross-over trial. Arch Dis Child Fetal Neonatal Ed. 2023 May;108(3):232-236. doi: 10.1136/archdischild-2022-324462. Epub 2022 Oct 19.

    PubMed 36261145

Questions about this trial

What is this clinical trial studying?

A study testing Nasal mask interface and Nasal prongs interface in people with Respiration; Insufficient or Poor, Newborn and Infant,Premature, run by Baldvin Jonsson at 2 sites in Sweden.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 13 Nov 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Sweden. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Leakage in the CPAP system (time frame: 0-60 min). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03586856, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Nov 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in