AzTrials
AzTrials

Laryngeal MaskNCT03544749

A Comparison of Ambu® AuraGain™ Laryngeal Mask Airway and I-gel in Adult

A study testing Ambu® AuraGain™ and I-gel in people with Laryngeal Mask and Intubation; Difficult or Failed, run by Seoul National University Hospital at 1 site in South Korea.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The supraglottic airway device(SAD), as an alternative to the endotracheal tube is inserted into the oral cavity and seals the upper esophagus and the surrounding tissue, effectively securing airway. SAD has evolved in recent years to increase efficiency and secure safety. Read more about this study

Who is it for?
Ages 20 years and older
What is being tested?
Ambu® AuraGain™ and I-gel
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
104 participants
Where
1 siteSouth Korea
Study dates
7 Jun 2018to 12 Oct 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients who are undergoing surgery under general anesthesia where supraglottic airway management will be appropriate.

Who cannot join

  • Body mass index > 35 kg/m2
  • High risk of regurgitation (hiatus hernia, gastro-esophageal reflux disease, non-fasting status)
  • Criteria for difficult airway
  • Patients with cervical disease or previous cervical spine surgery

Trial locations and contacts

1 site in 1 country.

South Korea1 site
  • Seoul National University Hospital

    Seoul

Other trials in South Korea

About this study

Official title: A Randomized Comparison of Ambu® AuraGain™ Laryngeal Mask Airway and I-gel in Patients With Simulated Cervical Immobilization

The supraglottic airway device(SAD), as an alternative to the endotracheal tube is inserted into the oral cavity and seals the upper esophagus and the surrounding tissue, effectively securing airway. SAD has evolved in recent years to increase efficiency and secure safety. The recently developed Ambu® AuraGain™ is a second-generation SAD with a built-in gastric port and is designed to be fitted well in the larynx and oral cavity after insertion because the shaft is bent at an angle of 90 degrees and has an inflatable cuff.

In a previous study, Ambu® AuraGain™ showed a higher sealing pressure and better fibreoptic finding compared to LMA Supreme in laparoscopic surgery.

Read more

On the other hand, I-gel and Ambu® AuraGain™, both of the second-generation SAD, show comparatively excellent performance according to the results of previous studies. However, there are no studies comparing the characteristics of two airway devices in adults.

The purpose of this study is to compare the performance of I-gel and Ambu® AuraGain™ to make a difficult airway-like situation using cervical collar for adult patients receiving mechanical ventilation under general anesthesia.

Being tested
Ambu® AuraGain™, I-gel

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Ambu® AuraGain™Device

    After induction of anesthesia, Ambu® AuraGain™ will be inserted for the mechanical ventilation.

  • I-gelDevice

    After induction of anesthesia, I-gel will be inserted for the mechanical ventilation.

Study groups in NCT03544749
Study groupRoleWhat they receive
Ambu® AuraGain™ groupExperimentalNot described
Receives: Device: Ambu® AuraGain™
I-gel groupActive comparatorNot described
Receives: Device: I-gel

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Oropharyngeal leak pressure

    Oropharyngeal leak pressure is measured by closing the expiratory valve and administering fresh gas flow of 6 L/min, until the equilibrium pressure is reached (to a maximum of 40 cm of H2O).

    Measured: At an average of 30 seconds after insertion of laryngeal mask airway

Secondary outcomes (14)
  1. Oropharyngeal leak pressure

    Oropharyngeal leak pressure is measured by closing the expiratory valve and administering fresh gas flow of 6 L/min, until the equilibrium pressure is reached (to a maximum of 40 cm of H2O).

    Measured: At 5 minute after insertion of laryngeal mask airway

  2. The time for successful insertion of the device

    The total time is measured from the removal of the face mask until bilateral chest rise with the first capnogram upstroke.

    Measured: During induction of anesthesia, an average of 60 seconds

  3. Success rate in first attempt

    Successful insertion of laryngeal mask airway in a first attempt

    Measured: During induction of anesthesia, an average of 60 seconds

  4. Overall success rate

    Successful insertion of laryngeal mask airway in a maximum of three attempts

    Measured: During induction of anesthesia, an average of 60 seconds

  5. The ease of insertion of device

    The ease of placement was assessed using a subjective scale of 1-4 (1= no resistance, 2 = moderate resistance, 3 = high resistance, 4 = inability to place the device)

    Measured: During induction of anesthesia, an average of 60 seconds

  6. The number of attempts at insertion of device

    The number of attempts for successful insertion of laryngeal mask airway

    Measured: During induction of anesthesia, an average of 60 seconds

  7. The ease of gastric tube placement

    The ease of gastric tube placement was graded on a subjective scale (1 = easy, 2 = difficult, 3 = unable to pass)

    Measured: During induction of anesthesia, an average of 5 minutes

  8. The time for successful gastric tube placement

    The insertion time is measured from first handling of the gastric tube to confirmation of its position in the stomach by aspiration of gastric fluid.

    Measured: During induction of anesthesia, an average of 5 minutes

  9. The grade of fiberoptic bronchoscopic view

    The fiberoptic bronchoscopic view is defined as Grade 1, larynx only seen; Grade 2, larynx and epiglottis posterior surface seen; Grade 3, larynx, and epiglottis tip or anterior surface seen-visual obstruction of epiglottis to larynx: < 50%; Grade 4, epiglottis down-folded, and its anterior surface seen-visual obstruction of epiglottis to larynx: > 50%; Grade 5, epiglottis downfolded and larynx cannot be seen directly.

    Measured: During induction of anesthesia, an average of 5 minutes

  10. Peak inspiratory pressure

    Peak inspiratory pressure is recorded from mechanical ventilator.

    Measured: At 5 minute after insertion of laryngeal mask airway

  11. The number of airway maneuvers required to maintain airway patency

    Airway maneuvers required to maintain airway patency, including jaw thrust, head/neck extension and/or device adjustments such as advancement/withdrawal of device, and alterations to cuff volume.

    Measured: During the surgery, an average of 2 hours after anesthesia induction

  12. The type of airway maneuvers required to maintain airway patency

    Airway maneuvers required to maintain airway patency, including jaw thrust, head/neck extension and/or device adjustments such as advancement/withdrawal of device, and alterations to cuff volume.

    Measured: During the surgery, an average of 2 hours after anesthesia induction

  13. Intraoperative complications

    Intraoperative complications including coughing, laryngospasm, bronchospasm, hypoxia (SpO2 < 90%), regurgitation, aspiration, blood staining of the device.

    Measured: During the surgery, an average of 2 hours after anesthesia induction

  14. Postoperative complications

    Postoperative complications including sore throat, hoarseness/dysphonia, jaw, neck or ear pain, persistent cough, tachypnea, stridor, hypoxia (SpO2 < 90%), nausea and vomiting.

    Measured: An average of 2 hours after extubation

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Jun 2018
  2. Study start7 Jun 2018
  3. Primary completion27 Sep 2018
  4. Study completion12 Oct 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Parallel groups
Model description
Randomized controlled trial
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
104 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03544749
Sponsor's protocol ID
1803-124-932
Status last verified
Jul 2019
First submitted
22 May 2018
Last updated
18 Jul 2019
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

A study testing Ambu® AuraGain™ and I-gel in people with Laryngeal Mask and Intubation; Difficult or Failed, run by Seoul National University Hospital at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 Jul 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Oropharyngeal leak pressure (time frame: At an average of 30 seconds after insertion of laryngeal mask airway). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Jul 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in