AzTrials
AzTrials

Aortic StenosisNCT03454360

CHANGE Neo™ TA Registry With ACURATE Neo™ Aortic Bioprosthesis and ACURATE Neo™ TA Transapical Delivery System

An observational study of Aortic Stenosis, run by Symetis SA at 10 sites in Germany.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

The purpose of this registry is to collect specific health and patient data to identify more precisely the patient population undergoing TA aortic valve replacement with the ACURATE neo™ Aortic biprosthesis and ACURATE neo™ TA Transapical Delivery System. Read more about this study

Who is it for?
Any age
Conditions the study is for
Aortic Stenosis
What is being tested?
ACURATE neo™ Aortic Bioprosthesis
Type of treatment
Medical device
How many people
107 participants
Where
10 sitesGermany
Study dates
6 Feb 2018to 30 Apr 2020
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Study population: All subjects with severe aortic stenosis, for whom the transapical access is the most suitable approach as per heart-team consensus, who signed the Informed Consent Form (ICF) approved by the Independent Ethics Committee (IEC), and are deemed to be candidates to undergo transcatheter aortic valve implantation with the ACURATE neo™ Aortic Bioprosthesis and its Transapical Delivery System as per clinical practice at each participating site

Who may be able to join

  • Symptomatic patients with severe aortic stenosis;
  • Institution heart team determines that aortic valve replacement ACURATE neoTM device using its transapical delivery system is appropriate;

Who cannot join

  • Patients unable or unwilling to give inform consent;

Trial locations and contacts

10 sites in 1 country.

10 sites in 1 country

Germany10 sites
  • Kerckhoff Klinik

    Bad Nauheim, 61231

  • Herz-und Gefäß-Kilink GmbH

    Bad Neustadt an der Saale, 97616

  • Krankenhausbetriebgesellschaft

    Bad Oeynhausen, D-32545

  • BG Klinik Bergmannsheil

    Bochum, 44789

  • Universitätsklinikum Frankfurt- Klinik für Thorax, Herz und thorakale Gefæßchirurgie

    Frankfurt, 60590

  • Universitäts-Herzzentrum Freiburg-Bad Krozingen

    Freiburg im Breisgau, 79106

  • Universitätsklinikum Hamburg-Eppendorf

    Hamburg, 20246

  • Herzzentrum Leipzig

    Leipzig, 04289

  • Deutsches Herzzentrum München

    München, 80636

  • Universitätsklinikum Regensburg

    Regensburg, 93053

Other trials in Germany

About this study

Official title: Collection of Specific Health And Patient Related Criteria Used to Select traNsapical TAVI Treatment and correspondinG outcomEs: CHANGE Neo™ TA Registry

The purpose of this registry is to collect specific health and patient data to identify more precisely the patient population undergoing TA aortic valve replacement with the ACURATE neo™ Aortic biprosthesis and ACURATE neo™ TA Transapical Delivery System.

Safety and efficacy data will be collected to support the commercial use of the ACURATE neo™ Aortic Bioprosthesis and ACURATE neo™ TA Transapical Delivery System in a specific TA population.

As per IFU, the ACURATE neo™ and its ACURATE neo™ TA Delivery System are intended for use in minimally invasive, transcatheter aortic valve replacement using transapical access in patients presenting with severe aortic valve stenosis.

Read the detailed description

The Primary Objective of this post-market registry is to collect specific health and patient characteristics to understand the indication for TA-TAVI and to further evaluate the safety and performance of the ACURATE neo ™ Aortic Bioprosthesis and ACURATE neo™ TA Transapical Delivery System in a specific TA population, consisting of 200 consented patients.

Conditions
Aortic Stenosis
Being tested
ACURATE neo™ Aortic Bioprosthesis
Keywords
TAVI, Transcatheter Aortic Valve Replacement, Transcatheter Aortic Valve, Transapical Access
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ACURATE neo™ Aortic BioprosthesisDevice

    Also called ACURATE neo™ TA Delivery System

    TAVI; Transcatheter Aortic Valve Replacement. Transapical Access.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. All cause mortality

    the rate of all-cause mortality as measured at 30-days

    Measured: 30 days

Secondary outcomes (7)
  1. Safety and performance data will be collected to support the commercial use of the ACURATE neo ™ Aortic Bioprosthesis and ACURATE neo™ TA Transapical Delivery System in a specific TA population.

    Clinical events as defined per VARC 2 consensus document at procedure:

    All cause mortality; Stroke; Myocardial Infarction; Bleeding complication; Acute kidney injury; Vascular complication; Conduction disturbances and arrhythmia; Other TAVI-related complications

    Measured: Procedure to Discharge, 30 days and 12-months

  2. Procedural Success

    Defined as absence of intra-procedure mortality (procedure to 24H) AND absence of complications arising during implantation of the prosthetic valve such as: inability to properly seat the valve in the annulus; need for more than one implanted aortic bioprosthesis (valve-in-valve or ectopic deployment) or if a surgical aortic valve replacement is required to correct a severe aortic regurgitation or procedure complication. The procedure can be considered as success despite the presence of residual aortic regurgitation, which may be due to the anatomic configuration of the annulus or a calcific valvular annulus.

    Measured: Procedure to 24-hours

  3. Device Success

    Defined as;

    • Absence of intra-procedure mortality (procedure to 24H) AND,
    • Correct positioning (placement in the annulus with no impairment of aortic bioprosthesis function) of a single prosthetic heart valve into the proper anatomical location AND,
    • Intended performance of the prosthetic heart valve assessed prior to discharge per local standard of care and defined as:
    • No prosthesis-patient mismatch (EAOi >0.85 cm2/m2 or EAOi >0.7 cm2/m2 for BMI ≥30 kg/m2) ) AND,
    • Mean aortic valve gradient <20mmHg or peak velocity < 3 m/s AND,
    • No moderate or severe prosthetic valve regurgitation.

    For echo parameters for the performance assessment, a pre-discharge echo examination should be performed as per local standard of care. If echo parameter pre-discharge is missing, any echo parameter within 45 days post-procedure may be used.

    Measured: Post-procedure to Discharge.

  4. VARC 2 Composite Safety

    Defined as:

    • All-cause mortality
    • All stroke
    • Life-threatening bleeding
    • Acute Kidney Injury- Stage 2 or 3
    • Coronary Artery Obstruction requiring intervention
    • Major Vascular Complications
    • Valve-related dysfunction requiring repeat procedure

    Measured: 30-days

  5. Functional improvement as per NYHA Functional Classification

    Change on NYHA Class between baseline and different follow-up

    Measured: from baseline to, discharge, 30-days and 12-months follow-up.

  6. Improvement of EOA and mean Trans-prosthetic gradient

    If the echo parameter pre-discharge is missing to assess the intended performance, any echo parameter data within 45-days post procedure may be used for the missing values;

    Measured: from baseline to discharge, 30- days and 12 months follow-up

  7. Total Aortic Regurgitation

    Change on Aortic Regurgitation over time at follow-up

    Measured: post-procedure, prior to discharge, at 30-days and 12-months follow-up;

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Mar 2018
  2. Study start6 Feb 2018
  3. Primary completion30 Apr 2020
  4. Study completion30 Apr 2020

Why it stopped: Sponsor business decision unrelated to product safety or efficacy.

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
107 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03454360
Sponsor's protocol ID
2016-03
Status last verified
Dec 2020
First submitted
31 Jul 2017
Last updated
11 Dec 2020
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided: The data and study protocol for this clinical trial may be made available to other researchers in accordance with the Boston Scientific Data Sharing Policy (http://www.bostonscientific.com/en-US/data-sharing-requests.html).

Questions about this trial

What is this clinical trial studying?

An observational study of Aortic Stenosis, run by Symetis SA at 10 sites in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 11 Dec 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 10 sites in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: Sponsor business decision unrelated to product safety or efficacy.). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

All cause mortality (time frame: 30 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Dec 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in