AzTrials
AzTrials

Proximal Humeral FractureNCT03427112

Assessment of the Surgical Handling and Performance of the X-ray-based Tracking and Navigation System "Xin1 Humerus System" Evaluated From 10 Proximal Humerus Plate Fixations

An observational study of Proximal Humeral Fracture, run by AO Research Institute Davos at 1 site in Belgium.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Xin1 Humerus system is an X-ray-based tracking and navigation system designed to calculate the plate position and all required proximal screw lengths for proximal humerus plate fixation. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Proximal Humeral Fracture
What is being tested?
Xin1 Humerus System
Type of treatment
Medical device
How many people
11 participants
Where
1 siteBelgium
Study dates
4 Apr 2017to 6 Mar 2020
How long will I take part?
1 Day
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Adult, Older adult

Study population: Patients with proximal humerus fracture which are transferred to the Dpt. Traumatologie, ZU Leuven, will be recruited during diagnosis and indication.

Who may be able to join

  • Age 18 years and older
  • Diagnosis of proximal humerus fracture
  • Indicated for plate fixation osteosynthesis
  • Informed consent obtained

Who cannot join

None listed.

Trial locations and contacts

1 site in 1 country.

Belgium1 site
  • UZ Leuven campus Gasthuisberg

    Leuven, 3000

Other trials in Belgium

About this study

Official title: Clinical Validation of the Xin1 Humerus System

Xin1 Humerus system is an X-ray-based tracking and navigation system designed to calculate the plate position and all required proximal screw lengths for proximal humerus plate fixation. The aim is to validate the system performance in a clinical context and test the surgical handling of the Xin1 marker in a hospital environment. 10 adults having sustained a proximal humerus fracture and are indicated for plate fixation osteosynthesis will be provided intraoperatively with the Xin1 marker. The system performance is evaluated retrospectively by post-processing the intraoperative X-ray images after surgery

Read the detailed description

Treatment of fragility fractures at the proximal Humerus still remains a major challenge in trauma surgery. Several factors such as highly compromised bone mass, complex loading conditions, multi-fragment fractures, absent bony support and limited surgical access render the fixation particularly complex. Especially in elderly osteoporotic patients, implant position and fixation plays a key role for a successful outcome. Nowadays, complication rates of plate and screw fixation systems in the proximal Humerus region under complex fracture patterns are reported to range between 28% and 79%. A significant portion of these cases can be attributed to implant mal-placement. Particularly, when screws are too short and the subchondral bone stock is missed out, screw anchorage is significantly compromised. On the other hand, if screws are too long they might penetrate into the joint with devastating consequences. Adequate selection of screw length is hence of utmost importance. However, the particular anatomical situation challenges the determination procedure which results in prolonged operational time and increased X-ray exposure. New strategies are needed to simply, reliably and accurately fix proximal humeral fractures with plate-screw constructs. Xin1 is an X-ray-based tracking and navigation system designed to simplify a variety of surgical applications. For the Humerus application the position in space of the proximal Humerus plate is calculated in such manner, which then can be related to the position of the humeral head as derived from an image pair. All required proximal screw lengths are determined from these two radiographs. From ex-vivo evaluation the Xin1 Humerus System has proven its value in terms of accuracy increase as well as time and X-ray reduction. A clear potential for improving clinical practice is therefore apparent. The consequent next step is a first clinical phase verifying the basic function of the Xin1 system in a clinical context and investigating the surgical handling in a hospital environment.

This clinical trial aims to

  1. validate the Xin1 Humerus system performance in a clinical context.
  2. test the surgical handling of the Xin1 marker in a hospital environment.

There is no additional time effort required from the patient. All capacitated adults having sustained a proximal humerus fracture indicated for plate fixation osteosynthesis can be included in the study. The study is limited to 10 patients and 1 year. To minimize the patient risk it is suggested in this first study phase to entirely eliminate the system feedback to the surgeon during surgery. The system performance is evaluated retrospectively by post-processing X-ray images after surgery. The Xin1 system used during surgery is thereby reduced to the Xin1 marker clip (REF 100838-00) only.

Being tested
Xin1 Humerus System
Medical subject headings
Shoulder Fractures

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Xin1 Humerus SystemDevice

    Retrospective assessment of the surgical handling and performance of the X-ray-based tracking and navigation system "Xin1 Humerus system" evaluated from 10 proximal humerus plate fixations

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Influence of plate fixation on the determined screw lengths derived from the Xin1 Humerus System

    Xin1 Humerus System:

    • Screw lengths determined after fracture reduction and temporary fixation
    • Screw lengths determined after final plate fixation

    Measured: during surgery

Secondary outcomes (3)
  1. Treatment information

    • Fracture classification according to AO
    • Anatomical side of the fracture
    • Actual screw lengths of the implanted screws
    • Cumulative fluoro time
    • Cumulative area dose product
    • Brand and Model of used C-arm

    Measured: during surgery

  2. Patient information

    • Gender
    • Age

    Measured: Preoperative

  3. System information

    • Accuracy estimation of the Xin1 Humerus System in terms of screw length prediction in the humeral head.

    Measured: during surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Feb 2018
  2. Study start4 Apr 2017
  3. Primary completion6 Mar 2020
  4. Study completion6 Mar 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Cross-sectional
Enrolment
11 participants (actual)
Target duration
1 Day
IDs, dates and publications
ClinicalTrials.gov ID
NCT03427112
Sponsor's protocol ID
Xin1Humerus
Other IDs
80M0661
Status last verified
Mar 2021
First submitted
18 Jan 2018
Last updated
1 Apr 2021
Results posted
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Voigt C, Woltmann A, Partenheimer A, Lill H. [Management of complications after angularly stable locking proximal humerus plate fixation]. Chirurg. 2007 Jan;78(1):40-6. doi: 10.1007/s00104-006-1241-0. German.

    PubMed 16998660
  • Solberg BD, Moon CN, Franco DP, Paiement GD. Locked plating of 3- and 4-part proximal humerus fractures in older patients: the effect of initial fracture pattern on outcome. J Orthop Trauma. 2009 Feb;23(2):113-9. doi: 10.1097/BOT.0b013e31819344bf.

    PubMed 19169103

Questions about this trial

What is this clinical trial studying?

An observational study of Proximal Humeral Fracture, run by AO Research Institute Davos at 1 site in Belgium.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 0 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 1 Apr 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Influence of plate fixation on the determined screw lengths derived from the Xin1 Humerus System (time frame: during surgery). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03427112, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Apr 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in