Paravalvular Leakage After TAVINCT03424902
Study of New Predictors and Short Term Outcomes of Paravalvular Leakage After Transcatheter Aortic Valve Implanation
An observational study of Paravalvular Leakage After TAVI, run by Marwan Sayed Mahmoud.
Trial summary
The presence of aortic regurgitation (AR) jet from the aorta into the left ventricle is the most common complication after TAVI, occurring in about 70% of patients but usually trivial or mild (4, 5). Read more about this study
- Who is it for?
- Any age
- Conditions the study is for
- Paravalvular Leakage After TAVI
- What is being tested?
- cardiac computed tomography and cardiac catheterization
- How many people
- 100 participants
- Where
- No sites listed yet
- Study dates
- 1 Sep 2020to 1 Mar 2021
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- All sexes
- No healthy volunteers
- Child, Adult, Older adult
Study population: -Intermediate or high risk patient for surgical aortic valve replacement (SAVR) STS/EuroSCORE II >4% or logistic EuroSCORE I >10%
Who may be able to join
- The following will be eligible for TAVI :
- Intermediate or high risk patient for surgical aortic valve replacement (SAVR) STS/EuroSCORE II >4% or logistic EuroSCORE I >10%(10).
- Contraindications for open chest surgery, such as(10) :
- Expected high perioperative risk due to comorbidities not adequately reflected by scores :
- <!-- -->
- Procelain aorta
Show all 9Show fewer
- Squelae of chest radiation.
- Severe chest deformation or scoliosis.
- Previous cardiac surgery .
Who cannot join
- A-clinical conditions.
- active endocarditis,
- myocardial infarction within 14 days
- cardiogenic shock
- Life expectancy of less than 1 year
- B-Anatomical conditions:
Show all 9Show fewer
- short distance between coronary ostia and aortic valve annulus.
- Size of aortic annulus out of range for TAVI(range from 18mm - 27mm)(10).
- C-Associated cardiac condition requiring concomitant intervention eg severe CAD require CABG ,aneurysm of ascending aorta ,severe mitral or tricuspid valve disease.
About this study
Official title: Study of New Predictors and Short Term Outcomes of Paravalvular Leakage Post Transcatheter Aortic Valve Implanation
The presence of aortic regurgitation (AR) jet from the aorta into the left ventricle is the most common complication after TAVI, occurring in about 70% of patients but usually trivial or mild (4, 5). In most previous studies, mild AR was not associated with a significantly shorter survival time (4, 5); however, the PARTNER trial demonstrated that it may be associated with worse long-term prognosis (3).
Significant AR (moderate and severe) is less common, occurring in approximately 15-20% of cases(6), and is considered one of the most important prognostic factors of mortality during short- and long-term follow-up (7, 8). It is, therefore, essential to understand the mechanisms and risk factors associated with the occurrence of AR in order to minimize its incidence .
Read more
Significant PVL most commonly results from(9):
- Incomplete prosthesis apposition to the native annulus due to calcification or annular eccentricity
- undersizing of the device and/or
- malpositioning of the valve . These observations seem to be true for both balloon-expandable and self-expandable THVs.
However there are some new predictors which may correlate to occurance of paravalvular leakage including :
- Eccentricity of aortic valve calcification.
- Characterization of aortic annular calcification.
- Associated mitral annular calcification.
- Angle of LVOT to ascending aorta measurement (LVOT-AO).
- The depth of implantation of valve in relation to aortic cusps.
Read the detailed description
Aim of work Assessment of new predictors and short term outcomes of paravalvular leakage after transcatheter aortic valve implantation (TAVI).
These new predictors are :
- Eccentricity of aortic valve calcification.
- Characterization of aortic annular calcification.
- Mitral annular calcification.
- Angle of LVOT to ascending aorta measurement (LVOT-AO).
- The depth of implantation of valve in relation to aortic cusps Patients and methods. The study will include ( ) patients both retrospective and prospective observational study
Inclusion criteria :
The following will be eligible for TAVI :
- Intermediate or high risk patient for surgical aortic valve replacement (SAVR) STS/EuroSCORE II >4% or logistic EuroSCORE I >10%(10).
- Contraindications for open chest surgery, such as(10) :
- Expected high perioperative risk due to comorbidities not adequately reflected by scores :
<!-- -->
- Procelain aorta
- Squelae of chest radiation.
- Severe chest deformation or scoliosis.
- Previous cardiac surgery .
Exclusion criteria(10) :
A-clinical conditions.
- active endocarditis,
- myocardial infarction within 14 days
- cardiogenic shock
- Life expectancy of less than 1 year
B-Anatomical conditions:
- short distance between coronary ostia and aortic valve annulus.
- Size of aortic annulus out of range for TAVI(range from 18mm - 27mm)(10).
C-Associated cardiac condition requiring concomitant intervention eg severe CAD require CABG ,aneurysm of ascending aorta ,severe mitral or tricuspid valve disease.
All patient will undergo :
- Written consent.
- Detailed history including symptoms (NYHA class) ,co morbidities(diabetes ,hypertension ,ischemic heart disease,previous PCI ,renal impairment,peripheral arterial disease , chronic obstructive pulmonary disease,cerebrovascular disease ,atrial fibrillation ,..)
- Clinical examination
- Electrocardiogram(detection of conduction disturbance , ischemic changes).
- Laboratory investigation (hemoglobin level ,creatinine,glomerular filteration rate(GFR))
- Echocardiography(11) :
1-Assesment of aortic valve by
- Mean and maximum pressure gradiant .
- Aortic valve area by continuity equation.
- Measurement of aortic valve annulus(by both transthoracic echocardiography in parasternal long axis view and transesophgeal echocardiography in long axis view ) .
- Assesment of associated aortic regurge (regurge jet,regurge fraction and volume) 2- Assesment of EF(by M-mode and simpsons method). 3-Assesment of other valves . 7-Computed tomography (cardiac CT )
<!-- -->
- Annular dimensions. Two diameters, the anteroposterior (AP) short axis and the mediolateral (ML) long axis will be measured, and the mean ([ML plus AP] divided by 2) will be calculated(12). The Cover Index is defined as 100x(nominal prosthesis diameter - CT mean annulus Diameter)/nominal prosthesis diameter (13,14), and the Eccentricity Index was calculated as 100 x(1 -(aortic annulus minimum diameter /maximum diameter) (15).
- Annular calcium . The cross-sectional axial annulus plane is used for the following analysis: 1-Amount of calcium is measured using Agatston calcium score(AgS)(16). 2-Characterization of annular calcification : Annular calcification is measured in two planes, depth (D) and width (W), and evaluated for shape (1 for protruding [D>W], 2 for round [D=W], and 3 for adherent [W>D]) for each side (noncoronary, right coronary, and left coronary annulus side)(12).
- Eccentricity of aortic valve calcification(EoC): The EoC is defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method) (16).
- Angle of LVOT to ascending aorta measurement (LVOT-AO). We consider the angle between the axis of the first 4 cm of the ascending aorta representing the contact surface with the upper part of the bioprosthesis and the LVOT axis representing the landing zone of the prosthesis. . This angle is determined on CT or using left ventriculography in RAO 30° during preparation of the patients for the procedure (17).
- Mitral annular calcification: is qualitatively determined by circumferential involvement of mitral ring, mild =less than 1/3 of mitral annulus , moderate =between 1/3and 1/2 of mitral annulus , severe =calcification more than half mitral annulus circumference (20). TAVI procedure: The detailed steps of procedure are reported by Nijhoff F,etal (19) .TAVI is performed through transfemoral or transapical approach, based on the feasibility of the iliofemoral anatomy and suitable access sites. All procedures are performed in a fully equipped hybrid cardiac catheterization laboratory. Surgical cutdown or suture-mediated closure device are used to close the vascular access site at the femoral arteries. Transesophageal echocardiography is used to support TAVI procedures, and fluoroscopy is used to guide the deployment of the valves and prosthesis positioning. Both predilatation of the native valve and prosthetic valve implantation are performed during rapid right ventricular pacing (160 to 200 beats/min) (19). Prosthesis position, function, and coronary ostia patency are assessed with transesophageal echocardiography and fluoroscopy . Procedural factors which relate to paravalvular leakage include:
- Valve type (balloon expandable or self expandable).
- Valve size in relation to aortic annulus size (cover index).
- The depth of implantation of valve in relation to aortic cusps. Depth of final device position in the LVOT will be measured using a final aortogram of the deployed bioprosthesis in RAO projection, displaying the aortic valve in optimal alignment with all 3 leaflets visible in the same plane. The depth of delivery is defined as the distance from the native aortic annular margin on the side of the non coronary cusp (NCC) to the most proximal edge on the corresponding side (deepest in the left ventricle) of the deployed stent-frame .In addition, the depth of delivery from the annular margin of the left coronary cusp to the corresponding side will be measured(20). Assesment of paravalvular leakage : 1-Angiographic evaluation of paravalvular leakage Ten minutes after the deployment of the prosthetic valve, angiography of the aortic root is performed to assess the severity of aortic regurgitation according to Sellers criteria (21). (0) no regurgitation. (1) only trace of contrast could be seen in the left ventricle, and it is cleared in each systole. (2) contrast filling the entire LV in diastole with less density compared with opacification of the ascending aorta. (3) contrast filling the entire LV in diastole equal in density to the contrast opacification of the ascending aorta. (4) contrast filling of the entire LV in diastole on the first beat with greater density compared with the contrast opacification of the ascending aorta. Two observers independently score the images. In case of discrepancy the images will be re-evaluated and consensus will be reached by a third observer. 2-Intraprocedural Transesophageal echocardiography : Both 2D and 3D TEE will be used to assess origin and severity of paravalvular leakage during procedure. 3-Transthoracic Echocardiographic study: All patients will be evaluated after TAVI by pre-discharge transthoracic echocardiography. The extent of PVL is assessed according to the main VARC criteria(9):
<!-- -->
- Semiquantitative parameters 1-Diastolic flow reversal in the descending aorta-pulsed wave : mild (Absent or brief) ,moderate ( early diastolic Intermediate), severe (Prominent holodiastolic) 2-Circumferential extent of prosthetic valve paravalvular regurgitation: (0) no regurgitation; (1) mild PVL is defined as<10 % circumferential extent; (2) moderate PVL was defined as [>10 % but<30 % of PVL and (3) severe PVL is defined as >30 % according to the updated VARC guideline , that is the circumferential extent of PVL in a parasternal short-axis view (19).
- Quantitative parameters:
- Regurgitant volume (ml/beat) mild (<30) , moderate (30-59) ,severe (>60).
- Regurgitant fraction (%) mild (< 30), moderate (30-49) ,severe (>50).
- Effective regurgitant orifice area (cm2) mild (<0.10) ,moderate (0.10-0.29) , severe (>0.30). Follow up patients after 1month : <!-- -->
- Clinical follow up (symptoms,hospital readmission ).
- Echocardiographic reassessment of paravalvular leakage using the VARC criteria .
Statistical analysis The collected data will be tabulated and statistically analyzed and will be shown in tables and figures.
- Conditions
- Paravalvular Leakage After TAVI
- Being tested
- cardiac computed tomography and cardiac catheterization
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
cardiac computed tomography and cardiac catheterizationDiagnostic test
assesment of certain predictors with CT and fluroscopy for paravalvular leakage
| Study group | Role | What they receive |
|---|---|---|
| group1 | patients with no or mild paravalular leakage Receives: Diagnostic Test: cardiac computed tomography and cardiac catheterization | |
| group 2 | patients with moderate or or severe paravalvular leakage Receives: Diagnostic Test: cardiac computed tomography and cardiac catheterization |
What is being measured
The primary outcome is the main question the study is designed to answer.
Incidence of significant paravalvular leakage
moderate or severe
Measured: 1 .5 year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted7 Feb 2018
- Study start1 Sep 2020 (estimated)
- Primary completion1 Dec 2020 (estimated)
- Study completion1 Mar 2021 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Paravalvular Leakage After TAVIStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Cross-sectional
- Enrolment
- 100 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Marwan Sayed Mahmoud
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor-investigator, Marwan Sayed Mahmoud, Assiut University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03424902
- Sponsor's protocol ID
- 13254
- Status last verified
- Jul 2020
- First submitted
- 1 Feb 2018
- Last updated
- 8 Jul 2020
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 8 Jul 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Study of New Predictors and Short Term Outcomes of Paravalvular Leakage Post Transcatheter Aortic Valve Implanation
- ClinicalTrials.gov ID
- NCT03424902
- Acronym / sponsor ID
- 13254
- Conditions
- Paravalvular Leakage After TAVI
- Study type
- Observational
- Recruitment status
- Unknown status
- Enrolment
- 100 participants (estimated)
- Lead sponsor
- Marwan Sayed MahmoudUniversity, hospital or other
- Study start
- 1 Sep 2020 (estimated)
- Primary completion
- 1 Dec 2020 (estimated)
- Study completion
- 1 Mar 2021 (estimated)
- First posted
- 7 Feb 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The presence of aortic regurgitation (AR) jet from the aorta into the left ventricle is the most common complication after TAVI, occurring in about 70% of patients but usually trivial or mild (4, 5). In most previous studies, mild AR was not associated with a significantly shorter survival time (4, 5); however, the PARTNER trial demonstrated that it may be associated with worse long-term prognosis (3).
Significant AR (moderate and severe) is less common, occurring in approximately 15-20% of cases(6), and is considered one of the most important prognostic factors of mortality during short- and long-term follow-up (7, 8). It is, therefore, essential to understand the mechanisms and risk factors associated with the occurrence of AR in order to minimize its incidence .
Significant PVL most commonly results from(9):
- Incomplete prosthesis apposition to the native annulus due to calcification or annular eccentricity
- undersizing of the device and/or
- malpositioning of the valve . These observations seem to be true for both balloon-expandable and self-expandable THVs.
However there are some new predictors which may correlate to occurance of paravalvular leakage including :
- Eccentricity of aortic valve calcification.
- Characterization of aortic annular calcification.
- Associated mitral annular calcification.
- Angle of LVOT to ascending aorta measurement (LVOT-AO).
- The depth of implantation of valve in relation to aortic cusps.
Detailed description
Aim of work Assessment of new predictors and short term outcomes of paravalvular leakage after transcatheter aortic valve implantation (TAVI).
These new predictors are :
- Eccentricity of aortic valve calcification.
- Characterization of aortic annular calcification.
- Mitral annular calcification.
- Angle of LVOT to ascending aorta measurement (LVOT-AO).
- The depth of implantation of valve in relation to aortic cusps Patients and methods. The study will include ( ) patients both retrospective and prospective observational study
Inclusion criteria :
The following will be eligible for TAVI :
- Intermediate or high risk patient for surgical aortic valve replacement (SAVR) STS/EuroSCORE II >4% or logistic EuroSCORE I >10%(10).
- Contraindications for open chest surgery, such as(10) :
- Expected high perioperative risk due to comorbidities not adequately reflected by scores :
<!-- -->
- Procelain aorta
- Squelae of chest radiation.
- Severe chest deformation or scoliosis.
- Previous cardiac surgery .
Exclusion criteria(10) :
A-clinical conditions.
- active endocarditis,
- myocardial infarction within 14 days
- cardiogenic shock
- Life expectancy of less than 1 year
B-Anatomical conditions:
- short distance between coronary ostia and aortic valve annulus.
- Size of aortic annulus out of range for TAVI(range from 18mm - 27mm)(10).
C-Associated cardiac condition requiring concomitant intervention eg severe CAD require CABG ,aneurysm of ascending aorta ,severe mitral or tricuspid valve disease.
All patient will undergo :
- Written consent.
- Detailed history including symptoms (NYHA class) ,co morbidities(diabetes ,hypertension ,ischemic heart disease,previous PCI ,renal impairment,peripheral arterial disease , chronic obstructive pulmonary disease,cerebrovascular disease ,atrial fibrillation ,..)
- Clinical examination
- Electrocardiogram(detection of conduction disturbance , ischemic changes).
- Laboratory investigation (hemoglobin level ,creatinine,glomerular filteration rate(GFR))
- Echocardiography(11) :
1-Assesment of aortic valve by
- Mean and maximum pressure gradiant .
- Aortic valve area by continuity equation.
- Measurement of aortic valve annulus(by both transthoracic echocardiography in parasternal long axis view and transesophgeal echocardiography in long axis view ) .
- Assesment of associated aortic regurge (regurge jet,regurge fraction and volume) 2- Assesment of EF(by M-mode and simpsons method). 3-Assesment of other valves . 7-Computed tomography (cardiac CT )
<!-- -->
- Annular dimensions. Two diameters, the anteroposterior (AP) short axis and the mediolateral (ML) long axis will be measured, and the mean ([ML plus AP] divided by 2) will be calculated(12). The Cover Index is defined as 100x(nominal prosthesis diameter - CT mean annulus Diameter)/nominal prosthesis diameter (13,14), and the Eccentricity Index was calculated as 100 x(1 -(aortic annulus minimum diameter /maximum diameter) (15).
- Annular calcium . The cross-sectional axial annulus plane is used for the following analysis: 1-Amount of calcium is measured using Agatston calcium score(AgS)(16). 2-Characterization of annular calcification : Annular calcification is measured in two planes, depth (D) and width (W), and evaluated for shape (1 for protruding [D>W], 2 for round [D=W], and 3 for adherent [W>D]) for each side (noncoronary, right coronary, and left coronary annulus side)(12).
- Eccentricity of aortic valve calcification(EoC): The EoC is defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method) (16).
- Angle of LVOT to ascending aorta measurement (LVOT-AO). We consider the angle between the axis of the first 4 cm of the ascending aorta representing the contact surface with the upper part of the bioprosthesis and the LVOT axis representing the landing zone of the prosthesis. . This angle is determined on CT or using left ventriculography in RAO 30° during preparation of the patients for the procedure (17).
- Mitral annular calcification: is qualitatively determined by circumferential involvement of mitral ring, mild =less than 1/3 of mitral annulus , moderate =between 1/3and 1/2 of mitral annulus , severe =calcification more than half mitral annulus circumference (20). TAVI procedure: The detailed steps of procedure are reported by Nijhoff F,etal (19) .TAVI is performed through transfemoral or transapical approach, based on the feasibility of the iliofemoral anatomy and suitable access sites. All procedures are performed in a fully equipped hybrid cardiac catheterization laboratory. Surgical cutdown or suture-mediated closure device are used to close the vascular access site at the femoral arteries. Transesophageal echocardiography is used to support TAVI procedures, and fluoroscopy is used to guide the deployment of the valves and prosthesis positioning. Both predilatation of the native valve and prosthetic valve implantation are performed during rapid right ventricular pacing (160 to 200 beats/min) (19). Prosthesis position, function, and coronary ostia patency are assessed with transesophageal echocardiography and fluoroscopy . Procedural factors which relate to paravalvular leakage include:
- Valve type (balloon expandable or self expandable).
- Valve size in relation to aortic annulus size (cover index).
- The depth of implantation of valve in relation to aortic cusps. Depth of final device position in the LVOT will be measured using a final aortogram of the deployed bioprosthesis in RAO projection, displaying the aortic valve in optimal alignment with all 3 leaflets visible in the same plane. The depth of delivery is defined as the distance from the native aortic annular margin on the side of the non coronary cusp (NCC) to the most proximal edge on the corresponding side (deepest in the left ventricle) of the deployed stent-frame .In addition, the depth of delivery from the annular margin of the left coronary cusp to the corresponding side will be measured(20). Assesment of paravalvular leakage : 1-Angiographic evaluation of paravalvular leakage Ten minutes after the deployment of the prosthetic valve, angiography of the aortic root is performed to assess the severity of aortic regurgitation according to Sellers criteria (21). (0) no regurgitation. (1) only trace of contrast could be seen in the left ventricle, and it is cleared in each systole. (2) contrast filling the entire LV in diastole with less density compared with opacification of the ascending aorta. (3) contrast filling the entire LV in diastole equal in density to the contrast opacification of the ascending aorta. (4) contrast filling of the entire LV in diastole on the first beat with greater density compared with the contrast opacification of the ascending aorta. Two observers independently score the images. In case of discrepancy the images will be re-evaluated and consensus will be reached by a third observer. 2-Intraprocedural Transesophageal echocardiography : Both 2D and 3D TEE will be used to assess origin and severity of paravalvular leakage during procedure. 3-Transthoracic Echocardiographic study: All patients will be evaluated after TAVI by pre-discharge transthoracic echocardiography. The extent of PVL is assessed according to the main VARC criteria(9):
<!-- -->
- Semiquantitative parameters 1-Diastolic flow reversal in the descending aorta-pulsed wave : mild (Absent or brief) ,moderate ( early diastolic Intermediate), severe (Prominent holodiastolic) 2-Circumferential extent of prosthetic valve paravalvular regurgitation: (0) no regurgitation; (1) mild PVL is defined as<10 % circumferential extent; (2) moderate PVL was defined as [>10 % but<30 % of PVL and (3) severe PVL is defined as >30 % according to the updated VARC guideline , that is the circumferential extent of PVL in a parasternal short-axis view (19).
- Quantitative parameters:
- Regurgitant volume (ml/beat) mild (<30) , moderate (30-59) ,severe (>60).
- Regurgitant fraction (%) mild (< 30), moderate (30-49) ,severe (>50).
- Effective regurgitant orifice area (cm2) mild (<0.10) ,moderate (0.10-0.29) , severe (>0.30). Follow up patients after 1month : <!-- -->
- Clinical follow up (symptoms,hospital readmission ).
- Echocardiographic reassessment of paravalvular leakage using the VARC criteria .
Statistical analysis The collected data will be tabulated and statistically analyzed and will be shown in tables and figures.
Study design
- Observational model
- Case only
- Time perspective
- Cross-sectional
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| group1 | – | Diagnostic Test: cardiac computed tomography and cardiac catheterizationpatients with no or mild paravalular leakage |
| group 2 | – | Diagnostic Test: cardiac computed tomography and cardiac catheterizationpatients with moderate or or severe paravalvular leakage |
Who may qualify
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
- Study population
- -Intermediate or high risk patient for surgical aortic valve replacement (SAVR) STS/EuroSCORE II >4% or logistic EuroSCORE I >10%
Key inclusion criteria (9 listed)
- The following will be eligible for TAVI :
- <!-- -->
Key exclusion criteria (9 listed)
- A-clinical conditions.
- short distance between coronary ostia and aortic valve annulus.
- Size of aortic annulus out of range for TAVI(range from 18mm - 27mm)(10).
- C-Associated cardiac condition requiring concomitant intervention eg severe CAD require CABG ,aneurysm of ascending aorta ,severe mitral or tricuspid valve disease.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| cardiac computed tomography and cardiac catheterizationassesment of certain predictors with CT and fluroscopy for paravalvular leakage | Diagnostic test | group 2, group1 |
Primary outcome
Incidence of significant paravalvular leakage
Time frame: 1 .5 year
moderate or severe
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 8 Jul 2020.
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
Questions about this trial
What is this clinical trial studying?
An observational study of Paravalvular Leakage After TAVI, run by Marwan Sayed Mahmoud.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 9 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 8 Jul 2020. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Incidence of significant paravalvular leakage (time frame: 1 .5 year). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Jul 2020.