Validation of Gait Speed Device Against Existing TechniquesNCT03406806

Gaitbox Validation Study

A study testing Gaitbox, SprintSystem device and NIH toolbox 4 meter walk in people with Validation of Gait Speed Device Against Existing Techniques, run by Duke University at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to validate the walking velocity measured by the Gaitbox as compared to the measures obtained by clinicians administering the timed 4 meter walk test and the Sprint System device. The investigators have developed a compact device, the Gaitbox, which measures walking speed automatically. Read more about this study

Who is it for?
Ages 55 years and olderHealthy volunteers can take part
What is being tested?
Gaitbox, SprintSystem device and NIH toolbox 4 meter walk
Could I receive a placebo?
No, everyone receives an active treatment
How many people
35 participants
Where
1 siteUnited States
Study dates
14 Mar 2018to 14 Mar 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 55 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Male and female subjects aged 55 or older
  • Subjects must be able to complete three 5 meter walks, with or without assistive device such as canes, crutches or walkers.

Who cannot join

  • Subjects with a physical, cognitive, or behavioral impairment that would prevent the safe completion of the testing, or affect the ability to follow study directions will be excluded from participation.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Duke University

    Durham, North Carolina, 27705

Other trials in United States

About this study

Official title: Comparison of the Gaitbox, SprintSystem Device and NIH Toolbox 4 Meter Walk

The purpose of this study is to validate the walking velocity measured by the Gaitbox as compared to the measures obtained by clinicians administering the timed 4 meter walk test and the Sprint System device. The investigators have developed a compact device, the Gaitbox, which measures walking speed automatically. The device has an infrared light sensor that is capable to accurate distance measurements. To take a speed measurement, the device is placed at the end of the walking path and the subject simply walks towards the device. The device automatically records a starting and ending distance and calculates and displays walking speed in m/sec. This is a prospective, single site study. Up to 60 subjects will be enrolled at Duke. Subjects will be asked to complete the 4-meter walk test, three (3) times. Three speed measuring methods will be conducted simultaneously: NIH toolbox 4 meter clinic walk test and the Sprint System device (commercially available device typically used for timing track and field events), and the Gaitbox. The purpose is to validate the Gaitbox to the clinical NIH toolbox 4 meter test and against the Sprint System device. The following comparisons of speed will be made: Human timer 1 to human timer 2, Average human timer to Gaitbox, Gaitbox to Sprint System.

Read the detailed description

This is a prospective, single site study. Up to 60 subjects will be enrolled at Duke. Subjects will be asked to complete the 4-meter walk test, three (3) times. Three speed measuring methods will be conducted simultaneously: NIH toolbox 4 meter clinic walk test and the Sprint System device (commercially available device typically used for timing track and field events), and the Gaitbox.

NIH toolbox 4 meter clinic walk test: The walking path will be set according to the directions of the NIH toolbox 4 meter clinic walk test which includes marking the beginning and end of the walking path. Tape will be used to mark beginning and end of timing section of the walking path to allow for acceleration and deceleration. A standard manual stopwatch will be used to record time. The examiner will demonstrate the task then instruct the participant to "Walk at a comfortable pace" and count down by saying: "3, 2, 1, go." The stop watch will be used to time the amount of time it takes to walk between the cones. Subjects will complete 3 timed trials. The time will be recorded in the log.

Simultaneously, the Sprint System will be operated according to manufacturers instructions. The device will be setup on tripods 4 feet from the floor so as to be triggered by the subject's torso rather than feet and set to measure data at the same distances as the gait box. The device will be set up to record times at the same distances as the Gaitbox. The Sprint System is used to time track running events by breaking two invisible light beams. Timing starts when the subject crosses the first line and stops when the second line is crossed. The times are displayed on a handheld display. Times will be transferred to the log sheet.

The Gaitbox will be set up at the end of the 4 meter walking path at a height of 4 feet from the floor. To operate, investigator presses reset button, waits for ready light and tells subject to go. Speed is measured automatically and result is displayed. Times/speeds will be recorded on log sheet.

Being tested
Gaitbox, SprintSystem device, NIH toolbox 4 meter walk

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • GaitboxOther

    The walking path will be set according to the directions of the NIH toolbox 4 meter clinic walk test which includes marking the beginning and end of the walking path. A standard manual stopwatch will be used to record time. The examiner will demonstrate the task then instruct the participant to "Walk at a comfortable pace" and count down by saying: "3, 2, 1, go." The stop watch will be used to time the amount of time it takes to walk between the cones. Subjects will complete 3 timed trials. The time will be recorded in the log. Simultaneously, the Sprint System [6] will be operated according to manufacturers instructions. The Gaitbox will be set up at the end of the 4 meter walking path at a height of 4 feet from the floor. Times/speeds will be recorded on log sheet.

  • SprintSystem deviceOther

    The walking path will be set according to the directions of the NIH toolbox 4 meter clinic walk test which includes marking the beginning and end of the walking path. A standard manual stopwatch will be used to record time. The examiner will demonstrate the task then instruct the participant to "Walk at a comfortable pace" and count down by saying: "3, 2, 1, go." The stop watch will be used to time the amount of time it takes to walk between the cones. Subjects will complete 3 timed trials. The time will be recorded in the log. Simultaneously, the Sprint System [6] will be operated according to manufacturers instructions. The Gaitbox will be set up at the end of the 4 meter walking path at a height of 4 feet from the floor. Times/speeds will be recorded on log sheet.

  • NIH toolbox 4 meter walkOther

    The walking path will be set according to the directions of the NIH toolbox 4 meter clinic walk test which includes marking the beginning and end of the walking path. A standard manual stopwatch will be used to record time. The examiner will demonstrate the task then instruct the participant to "Walk at a comfortable pace" and count down by saying: "3, 2, 1, go." The stop watch will be used to time the amount of time it takes to walk between the cones. Subjects will complete 3 timed trials. The time will be recorded in the log. Simultaneously, the Sprint System [6] will be operated according to manufacturers instructions. The Gaitbox will be set up at the end of the 4 meter walking path at a height of 4 feet from the floor. Times/speeds will be recorded on log sheet.

Study groups in NCT03406806
Study groupRoleWhat they receive
GaitBoxExperimentalNot described
Receives: Other: Gaitbox
Sprint System deviceActive comparatorNot described
Receives: Other: SprintSystem device
NIH Toolbox 4 meter testActive comparatorNot described
Receives: Other: NIH toolbox 4 meter walk

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time of 4 meter walk test

    Measured: Up to 1 hour

  2. Speed of 4 meter walk test

    Measured: Up to 1 hour

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted23 Jan 2018
  2. Study start14 Mar 2018
  3. Primary completion14 Mar 2018
  4. Study completion14 Mar 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Non-randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
35 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03406806
Sponsor's protocol ID
Pro00089655
Status last verified
Mar 2018
First submitted
16 Jan 2018
Last updated
10 Dec 2018
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Lusardi, Michelle M. (2012). "Is Walking Speed a Vital Sign? Absolutely." Topics in geriatric rehabilitation 28(2): 67-76.

  • Guralnik JM, Ferrucci L, Pieper CF, Leveille SG, Markides KS, Ostir GV, Studenski S, Berkman LF, Wallace RB. Lower extremity function and subsequent disability: consistency across studies, predictive models, and value of gait speed alone compared with the short physical performance battery. J Gerontol A Biol Sci Med Sci. 2000 Apr;55(4):M221-31. doi: 10.1093/gerona/55.4.m221.

    PubMed 10811152
  • Studenski S, Perera S, Patel K, Rosano C, Faulkner K, Inzitari M, Brach J, Chandler J, Cawthon P, Connor EB, Nevitt M, Visser M, Kritchevsky S, Badinelli S, Harris T, Newman AB, Cauley J, Ferrucci L, Guralnik J. Gait speed and survival in older adults. JAMA. 2011 Jan 5;305(1):50-8. doi: 10.1001/jama.2010.1923.

    PubMed 21205966
  • Hardy SE, Perera S, Roumani YF, Chandler JM, Studenski SA. Improvement in usual gait speed predicts better survival in older adults. J Am Geriatr Soc. 2007 Nov;55(11):1727-34. doi: 10.1111/j.1532-5415.2007.01413.x. Epub 2007 Oct 3.

    PubMed 17916121

Questions about this trial

What is this clinical trial studying?

A study testing Gaitbox, SprintSystem device and NIH toolbox 4 meter walk in people with Validation of Gait Speed Device Against Existing Techniques, run by Duke University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 10 Dec 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Time of 4 meter walk test (time frame: Up to 1 hour). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03406806, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Dec 2018.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in