AzTrials
AzTrials

Endotracheal TubeNCT03385044

Comparison of Endotracheal Intracuff Pressure Between Two Cuff Sealing Methods

A study testing MOVT and VE/VI ratio of Spirometer in people with Endotracheal Tube, run by DongGuk University at 1 site in South Korea.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The endotracheal intracuff pressure is to be maintained at a low level to prevent trachea and nerve damages, and yet be high enough to secure air sealing. The objective of the study is to compare minimal occlusive volume technique (MOVT) and expired volume/inspired volume ratio (VE/VI ratio) from a spirometer method… Read more about this study

Who is it for?
Ages 20 to 60 years, women only
Conditions the study is for
Endotracheal Tube
What is being tested?
MOVT and VE/VI ratio of Spirometer
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
35 participants
Where
1 siteSouth Korea
Study dates
12 Mar 2018to 29 Oct 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 60 years
  • Women only
  • No healthy volunteers
  • Adult

Who may be able to join

  • American Society of Anesthesiologists physical status I, II
  • Body mass index < 30 kg/m2
  • Elective laparoscopic gynecologic surgery under general anesthesia in the Trendelenburg position

Who cannot join

  • History of airway-related or pulmonary diseases/abnormalities
  • When difficult intubation is anticipated
  • History of general anesthesia within the past 3 months
  • Pregnancy
  • History of smoking

Trial locations and contacts

1 site in 1 country.

South Korea1 site
  • Dept. of anesthesiology and pain medicine, Dongguk University Ilsan Hospital

    Goyang, Gyeonggido, 10326

Other trials in South Korea

About this study

The endotracheal intracuff pressure is to be maintained at a low level to prevent trachea and nerve damages, and yet be high enough to secure air sealing. The objective of the study is to compare minimal occlusive volume technique (MOVT) and expired volume/inspired volume ratio (VE/VI ratio) from a spirometer method of endotracheal tube (ETT) cuff inflation with respect to the cuff pressure required to seal the airway during a laparoscopic surgery under general anesthesia. A study design is a randomized crossover trial in 35 patients. The primary outcome is the intracuff pressure of an endotracheal tube. The study consists of two cuff sealing methods separated by a period of 10 minutes.

Being tested
MOVT, VE/VI ratio of Spirometer
Keywords
Endotracheal tube, Intracuff pressure, Minimal occlusive volume technique, Spirometer, Endotracheal sealing

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • MOVTProcedure or surgery

    ETT cuff will be inflated till the disappearance of audible air leak on auscultation, while abdominal carbon dioxide (CO2) inflation is maintained with peak inspiratory pressure of 25 cm H2O during volume controlled ventilation. The patient will be in the Trendelenburg position.

  • VE/VI ratio of SpirometerProcedure or surgery

    ETT cuff will be inflated till the VE/VI ratio meets the initial VE/VI ratio, while abdominal CO2 inflation is maintained with peak inspiratory pressure of 25 cm H2O during volume controlled ventilation. The patient will be in the Trendelenburg position.

Study groups in NCT03385044
Study groupRoleWhat they receive
Cuff sealing by MOVTActive comparatorMOVT (minimal occlusive volume technique). The cuff sealing will be confirmed with MOVT, then the intracuff pressure will be measured.
Receives: Procedure: MOVT
Cuff sealing by VE/VI ratioActive comparatorVE/VI ratio of Spirometer. The cuff sealing will be confirmed with VE/VI ratio of a spirometer, then the intracuff pressure will be measured.
Receives: Procedure: VE/VI ratio of Spirometer

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Intracuff Pressure

    The intracuff pressure of endotracheal tube when cuff sealing is achieved.

    Measured: From the start of cuff inflation to the airway sealing, an average of 2 minutes

Secondary outcomes (1)
  1. Intracuff air volume

    The intracuff air volume of endotracheal tube when cuff sealing is achieved.

    Measured: From the start of cuff inflation to the airway sealing, an average of 2 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Dec 2017
  2. Study start12 Mar 2018
  3. Primary completion29 Oct 2018
  4. Study completion29 Oct 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Model description
Two methods of cuff sealing will be applied in a random sequence to each patient.
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
35 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03385044
Sponsor's protocol ID
J_In_2017-01
Status last verified
Dec 2018
First submitted
20 Dec 2017
Last updated
14 Dec 2018
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing MOVT and VE/VI ratio of Spirometer in people with Endotracheal Tube, run by DongGuk University at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 14 Dec 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Intracuff Pressure (time frame: From the start of cuff inflation to the airway sealing, an average of 2 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Dec 2018.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in