Procedural BleedingPhase 4NCT03350217

A Comparison of Eleview Versus Hetastarch as Injectate for EMR

A Phase 4 study testing Eleview and Hetastarch in people with Procedural Bleeding and Delayed Bleeding, run by Indiana University at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record

Search all trials

Trial summary

EMR is a technique used for the removal of flat or sessile neoplasms confined to the superficial layers of the GI tract using a snare. Injection-assisted EMR is commonly used during resections of larger flat lesions as it provides submucosal lift of polyps, adenomas, other gastrointestinal mucosal lesions or… Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
What is being tested?
Eleview and Hetastarch
Type of treatment
Injection or infusion
Could I receive a placebo?
No, everyone receives an active treatment
How many people
160 participants
Where
1 siteUnited States
Study dates
9 Oct 2017to 7 Jan 2019
Phase
Phase 4

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Sex and age: men and women > 18 years old
  • Subjects referred for EMR of polyps of size ≥11 mm
  • ASA score 1, 2 or 3.
  • Contraception: Women of childbearing potential must have a negative pregnancy test (one is provided as the standard of care) or sign a waiver. Post-menopausal women must have been in that status for at least 1 year (per standard of care).
  • Subject is willing and able to participate in the study procedures and to understand and sign the informed consent

Who cannot join

  • Age: Subjects is under 18 years old
  • Consent: Vulnerable subjects including those who are unable to consent
  • Pregnancy: Pregnant or breastfeeding women
  • ASA score <3
  • Physical findings: Abnormal physical findings that may interfere with the study objectives
  • Study participation: Subjects currently participating in another clinical study or previously enrolled in another clinical study in the last 30 days
Show all 21Show fewer
  • Excluded lesions:
  • Lesions less than 11 mm in largest dimension
  • Lesions involving the muscularis propria (T2 lesions)
  • Ulcerated depressed lesions (Paris type III) or pathology proven invasive carcinoma
  • Proven malignant disease locally advanced or with metastasis
  • Active inflammatory bowel disease lesion, e.g ulcerative colitis, Crohn's disease
  • Endoscopic appearance of invasive malignancy
  • Previous partial resection or attempted resection of the lesion
  • Allergy: Proven or potential allergic reaction to study products or history of anaphylaxis to drugs
  • Severe liver disease.
  • Known or suspected gastrointestinal obstruction or perforation, active diverticulitis, toxic megacolon,
  • Inflammatory bowel disease e.g ulcerative colitis or Crohn's disease
  • Hemostasis disorders (eg Von Willebrand disease, factor V Leiden thrombophilia or haemophilia), known clotting disorder (INR>1.5).
  • Subject with any other current serious medical conditions that would increase the risks associated with taking part in the study.
  • Patients must be advised to stop anticoagulation medications prior to the procedure per local practice guidelines and should re-start as clinically indicated after the procedure.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Indiana University

    Indianapolis, Indiana, 46202

Other trials in United States

About this study

Official title: A Randomized, Double-blind, Comparative, Effectiveness and Safety Study of Eleview vs. Hetastarch in Subjects Undergoing Endoscopic Mucosal Resection (EMR) of Colonic Lesions Equal to or Larger Than 11mm

EMR is a technique used for the removal of flat or sessile neoplasms confined to the superficial layers of the GI tract using a snare. Injection-assisted EMR is commonly used during resections of larger flat lesions as it provides submucosal lift of polyps, adenomas, other gastrointestinal mucosal lesions or early-stage cancers prior to EMR. This has been found to minimize mechanical or electrocautery damage to the deep layers of the gastrointestinal tract wall as the injectate provides a "safety cushion" as such between the area to be removed and healthy mucosal tissue.

Several solutions are used today for injecting lesions including saline, hyaluronic acid, and hydroxyethyl starch (Hetastarch). Saline solution has been found to dissipate within minutes, which may result in a lower quality lesion lift. Hyaluronic acid provides a longer lift, but is expensive and is not readily available in the U.S.

Read more

A new injectate known as Eleview has been developed for use in gastrointestinal endoscopic procedures and recently approved by the FDA. This injectate boasts a cushion of excellent height and duration through the use of an oil-in-water emulsion. However, the initial cost of this material is quite high ($80 per 10 ml).

Hetastarch, which is the current injectate used by Dr Rex, is a safe and considerably inexpensive solution that provides prolonged submucosal elevation and lowers procedure times. Our study will aim to compare Eleview to Hetastarch in the hopes of finding the ideal submucosal injectate.

This trial will focus on polyps of size ≥11 mm removed by snare EMR technique. Patients with lesions deemed not suitable for EMR due to features suggestive of sub-mucosal invasion will not be included.

Read the detailed description

Injectate randomization:

Study patients will be randomly assigned to the Eleview or the Hetastarch treatment group in a 1:1 ratio. Randomization will occur at the site using envelopes provided by the Investigator. The envelope's contents will specify the treatment assignment for each patient and opened by the research team (PI will be blinded). The investigators will monitor the safety and effectiveness data. The appropriate solutions will be injected into the submucosal space beneath the lesion(s) to be excised before the lesion(s) is/are removed. Subjects in both groups will receive the appropriate volume of injectate deemed necessary by the PI for the individual patient.

Sample size and Statistical Analysis At least 200 patients will be enrolled. 100 of these patients will be randomized to Eleview injectate and 100 will be given the standard of care, Hetastarch injectate only. Efficacy and safety of Eleview injectate has only been reviewed in one previous study. Therefore, the planned sample size was not calculated using a statistical power analysis, but was regarded as sufficient to repeat the objectives of the COSMO study (2017) and satisfy the exploratory purposes of the present study.

Study personnel will carry out a simple randomization using a commonly used online generator. Randomization assignments will then be sealed until day of procedure until patient eligibility has been confirmed. The Principal Investigator will remain blinded and will perform all data analysis after completion of the study.

Data will be summarized and compared using classic descriptive statistics, i.e. mean, standard deviation, coefficient of variation (%), minimum, median and maximum values for quantitative variables, and frequencies for qualitative variables.

The Sydney Resection Quotient will be compared between treatment groups using a Wilcoxon Rank-Sum test. The proportion of subjects with en bloc resection of all endoscopically visible lesions will also be compared between treatment groups using a Fisher's exact test. A nominal alpha level of 0.05 will be used for both the comparisons.

No formal comparison will be performed for the secondary endpoints.

Being tested
Eleview, Hetastarch

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • EleviewDrug

    If a lesion in the colon is found to fit the description listed in the protocol, the subject will be randomized to Eleview or Hetastarch as the injectate solution for the procedure. The injectate solution is used, as needed, to aid in the resection of the target lesion.

  • HetastarchDrug

    Also called Hespan

    If a lesion in the colon is found to fit the description listed in the protocol, the subject will be randomized to Eleview or Hetastarch as the injectate solution for the procedure. The injectate solution is used, as needed, to aid in the resection of the target lesion.

Study groups in NCT03350217
Study groupRoleWhat they receive
EleviewActive comparatorThis arm will be administered the Eleview Injectate (up to 50 mL's) solution upon randomization, provided the lesion is equal to or greater than 11 millimeters.
Receives: Drug: Eleview
HetastarchActive comparatorThis arm will be administered Hetastarch (w/Methylene blue as a contrast agent) as the injection solution upon randomization, provided the lesion is equal to or greater than 11 millimeters.
Receives: Drug: Hetastarch

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Sydney Resection Quotient (SRQ)

    Comparison of the Sydney Resection Quotient between EMRs done using Eleview vs EMRs done using Hetastartch as the injection fluid. The Sydney Resection Quotient (SRQ) is the size of the polyp divided by the number of pieces in which the polyp was resected. A larger SRQ is better than a smaller SRQ.

    Measured: During the large polyp removal

Secondary outcomes (12)
  1. Injected Volume Needed for Initial Lesion Lift

    Comparison of the volume of injection fluid needed for initial lesion lift of Eleview vs Hetastarch.

    Measured: During initial injection portion of large polyp removal

  2. Injected Volume Needed for Complete Removal of Lesion

    Comparison of the volume of injection fluid needed for complete removal of lesion between Eleview and Hetastarch

    Measured: During the large polyp removal

  3. Number of Re-injections Needed During Resection

    Comparison of the number of re-injections needed during the large polyp removal. Number of re-injections is the number of times the injection device is passed down the scope to inject the polyp after initial injection during the large polyp resection.

    Measured: During the large polyp removal

  4. Number of En Bloc Resections

    Comparison of the number of polyps that were able to be removed in one piece during the resection between polyps injected with Eleview and polyps injected with Hetastarch

    Measured: During the large polyp removal

  5. Number of Pieces Resected Using Snares

    Comparison of the number of pieces removed using snare between polyps injected with Eleview compared with polyps injected with Hetastarch.

    Measured: During the large polyp removal

  6. Mound Concentration Diameter

    Comparison fluid behavior and ease of use between Eleview and Hetastarch rated on a 3-point scale (Excellent, Sufficient, or Inadequate). The more the fluid spread out laterally after being injected, the worse the rating would be. The more the fluid stayed concentrated around the polyp after injection, the better the rating would be.

    Measured: During the large polyp removal

  7. Mound Concentration Height

    Comparison of how well the injection fluid lifted the polyp during the large polyp removal between Eleview and Hetastarch rated by the following scale: Excellent, Sufficient, Inadequate. The more the polyp was able to be lifted vertically, the better the rating would be.

    Measured: During the large polyp removal

  8. Mound Duration

    Comparison of how long the injection fluid was able to keep the polyp lifted during the large polyp removal between Eleview and Hetastarch. This was rating using the following scale: Excellent, Sufficient, or Inadequate. The longer the injection fluid stayed concentrated and kept the polyp lifted, the better rating it received while rapid dissipation of the fluid would receive a worse rating.

    Measured: During the large polyp removal

  9. Ease of Injection

    Comparison of how easily the fluid was able to be injected. This was rated by the endoscopy technician assisting in the large polyp removal. It was rated on the following scale: Very Easy, Easy, Difficult, Very Difficult.

    Measured: During the large polyp removal

  10. Need for Additional Treatments Relating to the Polyp Resection Such as Avulsion, Coagulation or Ablation.

    Need for additional treatments relating to the polyp resection such as avulsion, coagulation or ablation. These treatments can be done in addition to endoscopic mucosal resection (EMR) in order to remove polyp tissue/treat the defect.

    Measured: During the large polyp removal

  11. Time Required to Remove the Lesion

    Time (in minutes) to remove the lesion completely (measured from the first injection to final excision of the lesion)

    Measured: During the large polyp removal

  12. Safety Outcomes as Assessed by Complications During or After the Procedure

    To evaluate the safety of Eleview for EMR procedures in relation to adverse events and occurrence of complications during and after the EMR procedure in comparison to Hetastarch injectate.

    Measured: during large polyp removal through 30 days post procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Nov 2017
  2. Study start9 Oct 2017
  3. Primary completion7 Jan 2019
  4. Study completion7 Jan 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Investigator
Enrolment
160 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03350217
Sponsor's protocol ID
1706751368
Status last verified
Dec 2019
First submitted
19 Oct 2017
Last updated
17 Dec 2019
Data monitoring committee
No
FDA-regulated drug
Yes
FDA-regulated device
No
Individual data sharing
No

Publications

  • Fasoulas K, Lazaraki G, Chatzimavroudis G, Paroutoglou G, Katsinelos T, Dimou E, Geros C, Zavos C, Kountouras J, Katsinelos P. Endoscopic mucosal resection of giant laterally spreading tumors with submucosal injection of hydroxyethyl starch: comparative study with normal saline solution. Surg Laparosc Endosc Percutan Tech. 2012 Jun;22(3):272-8. doi: 10.1097/SLE.0b013e318251553c.

    PubMed 22678327
  • ASGE Technology Committee; Liu J, Petersen BT, Tierney WM, Chuttani R, Disario JA, Coffie JM, Mishkin DS, Shah RJ, Somogyi L, Song LM. Endoscopic banding devices. Gastrointest Endosc. 2008 Aug;68(2):217-21. doi: 10.1016/j.gie.2008.03.1121. No abstract available.

    PubMed 18656592
  • ASGE Technology Committee; Hwang JH, Konda V, Abu Dayyeh BK, Chauhan SS, Enestvedt BK, Fujii-Lau LL, Komanduri S, Maple JT, Murad FM, Pannala R, Thosani NC, Banerjee S. Endoscopic mucosal resection. Gastrointest Endosc. 2015 Aug;82(2):215-26. doi: 10.1016/j.gie.2015.05.001. Epub 2015 Jun 12.

    PubMed 26077453
  • Rex DK, Broadley HM, Garcia JR, Lahr RE, MacPhail ME, McWhinney CD, Searight MP, Sullivan AW, Mahajan N, Eckert GJ, Vemulapalli KC. SIC-8000 versus hetastarch as a submucosal injection fluid for EMR: a randomized controlled trial. Gastrointest Endosc. 2019 Nov;90(5):807-812. doi: 10.1016/j.gie.2019.06.040. Epub 2019 Jul 6.

    PubMed 31288028

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in