Dry Age-related Macular DegenerationPRIMA FSNCT03333954
Feasibility Study of Compensation for Blindness With the PRIMA System in Patients With Dry Age Related Macular Degeneration
A study testing PRIMA Bionic Vision System in people with Dry Age-related Macular Degeneration, run by Science Corporation at 1 site in France.
Trial summary
In this study, the principle functionality of the device will be tested in humans for the first time. The study will evaluate the extent to which patients with atrophic dry age related macular degeneration (AMD) have evoked light perception using the implant. Read more about this study
- Who is it for?
- Ages 60 years and older
- Conditions the study is for
- Dry Age-related Macular Degeneration
- What is being tested?
- PRIMA Bionic Vision System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 5 participants
- Where
- 1 siteFrance
- Study dates
- 6 Nov 2017to 12 Dec 2024
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 60 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Is 60 years or older at the date of enrolment;
- Has a confirmed diagnosis of advanced dry age related macular degeneration with an atrophy size of at least 3 optic disc diameters;
- Has best corrected visual acuity of the study eye of logMAR 1.3 (20/400) or worse measured by ETDRS;
- Has no foveal perception measured by micro-perimetry in the study eye (≤ 4 dB on Opko scale or equivalent) ;
- Has a study eye that is able to perceive light;
- Has useful vision on the non-study eye;
Show all 9Show fewer
- Has a refraction of study eye between -3 and + 4 (limits included) for patient with IOL (there is no refraction criteria for patients with natural lens);
- Understands and accepts the obligation to present for all schedule follow-up visits.
- Patient signed informed consent
Who cannot join
- Has cataracts that may influence the visual function of the study eye;
- Has an aphakic study eye
- Had cataract surgery in the last 1 month;
- Active sub-macular choroidal neovascularization in the study eye;
- Has any disease (other than study allowed diseases) or condition that affects retinal function of the study eye (e.g., central retinal artery/vein occlusion, end-stage diabetic retinopathy, retinal detachment, infectious or inflammatory retinal disease, severe glaucoma, optic neuropathy, myopic chorio-retinal atrophy etc.);
- Has an implanted telescope in one eye;
Show all 28Show fewer
- Has any disease or condition that prevents adequate examination of the study eye including, but not limited to, corneal degeneration that cannot be resolved prior to implantation. Note, that this criterion is also important for the function of the implant;
- Has an endothelia cell count of less than 1000 cells/mm² in the study eye;
- Suffers from nystagmus;
- Has any disease or condition that precludes the understanding or communication of the informed consent, study requirements or test protocols (e.g., deafness, severe multiple sclerosis, amyotrophic lateral sclerosis, severe neuritis, etc);
- Has a history of epileptic seizure;
- Has a history of chronic or recurrent infection or inflammation that would preclude participation in the study;
- Has a known sensitivity to the contact materials of the implant (iridium oxide, silicon-carbide and titanium);
- Presents with hypotony in the study eye;
- Presents with hypertony in the study eye;
- Has another active implanted device (e.g. cochlear implant, pacemaker) that may interfere with the device function, or diagnoses requiring such an active implant;
- Has active cancer or a history of intraocular, optic nerve or brain cancer and metastasis;
- Is an immune-suppressed subject (e.g., due to HIV positive diagnosis, etc.);
- Is carrier of multi-resistant germs;
- Is receiving anticoagulation therapy that cannot be adapted to allow eye surgery;
- Is participating in another investigational drug or device study that may interfere with the present study;
- Patients with recurrent or chronic inflammations or infections are excluded from the study. Specifically, patients with the following disorders are excluded:
- Common inflammation - severe chronic and consuming diseases that frequently associated with infection (e.g. Crohn disease, Whipple's disease);
- Active inflammation in the area of the eye (e.g. herpes of cornea and/or conjunctiva, recurrent blepharoconjunctivitis, hordeolum, chalazion);
- Has a severe psychological disorder. When in any doubt, an expert assessment needs to be arranged to clarify whether the patient's psychological health is suitable for the trial. In any doubts of the subjects psychological status a clinical psychologist, psychologist or the community doctor/general practitioner should be involved. The patient must have the legal capacity to sign the informed consent;
- Has severe renal, cardiac, hepatic etc. organ diseases;
- Has head dimension that are incompatible with the Visual Interface.
- Has too high and unrealistic expectation (e.g., believes that a benefit is guaranteed or expect normal vision after surgery)
Trial locations and contacts
1 site in 1 country.
France1 site
Fondation Ophtalmologique A. De Rothschild/ Hopital des Quinze Vingts/
Paris, 75019
About this study
In this study, the principle functionality of the device will be tested in humans for the first time. The study will evaluate the extent to which patients with atrophic dry age related macular degeneration (AMD) have evoked light perception using the implant.
Read the detailed description
In this study subjects are provided with a PRIMA sub-retinal implant in one eye. A camera integrated in the external components of the implant captures visual information of the environment, this information is processed by a pocket processor and then transmitted via projected IR light onto the implant. The implant received the projected IR light and stimulates the nerve cells of the retina. Interim analysis will be performed at 6 months after implantation.
- Conditions
- Dry Age-related Macular Degeneration
- Being tested
- PRIMA Bionic Vision System
- Keywords
- atrophic macular degeneration, geographic atrophy, macular degeneration, dry macular degeneration, AMD, retina implant, retinal prosthesis, visual prosthesis
- Medical subject headings
- Geographic Atrophy, Macular Degeneration
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
PRIMA Bionic Vision SystemDevice
The PRIMA Bionic Vision System is a device for treatment of patients who have lost their sight through outer retinal degenerative conditions of the eye such as atrophic dry age related macular degeneration.
The PRIMA System is designed to provide partial restoration of the patient's visual function through electrical stimulation of the retinal neurons by a sub-retinally implanted stimulator that replace part of the degenerate photoreceptors
| Study group | Role | What they receive |
|---|---|---|
| PRIMA Bionic Vision System | Experimental | PRIMA Bionic Vision System Receives: Device: PRIMA Bionic Vision System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Elicitation of perception
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Measured: 6 months after implantation
Elicitation of perception
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Measured: 6 weeks after implantation
Elicitation of perception
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Measured: 3 months after implantation
Elicitation of perception
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Measured: 12 months after implantation
Elicitation of perception
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Measured: 18 months after implantation
Elicitation of perception
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Measured: 24 months after implantation
Elicitation of perception
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Measured: 36 months after implantation
Secondary outcomes (3)
Visual Acuity
Visual acuity is a measure of the ability of the visual system to distinguish shapes and details of objects at a given distance. This study use the Landolt Ring to measure visual acuity
Measured: 18, 24 and 36 months after implantation if applicable
Letter Visual Acuity
Visual acuity is a measure of the ability of the visual system to distinguish shapes and details of objects at a given distance. This endpoint use the ETDRS charts to measure visual acuity
Measured: 48, 60 and 72 month after implantation
Quality of Live measured by IVI
IVI-Impact of Vision Impairment questionnaire (quality of life based on patient reported outcome of functional vision, participation in vision-related daily living activities and emotional well-being)
Measured: 48, 60 and 72 month after implantation
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted7 Nov 2017
- Study start6 Nov 2017
- Primary completion12 Dec 2024
- Study completion12 Dec 2024
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (5)Papers the sponsor has linked to this study.
- Other trials for Dry Age-related Macular DegenerationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 5 participants (actual)
Sponsor and investigators
- Lead sponsor
- Science Corporation
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03333954
- Sponsor's protocol ID
- CIP-PRIMA-FS
- Acronym
- PRIMA FS
- Status last verified
- Mar 2026
- First submitted
- 27 Oct 2017
- Last updated
- 2 Apr 2026
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Palanker D, Le Mer Y, Mohand-Said S, Sahel JA. Simultaneous perception of prosthetic and natural vision in AMD patients. Nat Commun. 2022 Jan 26;13(1):513. doi: 10.1038/s41467-022-28125-x.
PubMed 35082313Muqit MMK, Mer YL, Holz FG, Sahel JA. Long-term observations of macular thickness after subretinal implantation of a photovoltaic prosthesis in patients with atrophic age-related macular degeneration. J Neural Eng. 2022 Oct 14;19(5):10.1088/1741-2552/ac9645. doi: 10.1088/1741-2552/ac9645.
PubMed 36174540Palanker D, Le Mer Y, Mohand-Said S, Muqit M, Sahel JA. Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration. Ophthalmology. 2020 Aug;127(8):1097-1104. doi: 10.1016/j.ophtha.2020.02.024. Epub 2020 Feb 25.
PubMed 32249038Muqit MMK, Le Mer Y, Olmos de Koo L, Holz FG, Sahel JA, Palanker D. Prosthetic Visual Acuity with the PRIMA Subretinal Microchip in Patients with Atrophic Age-Related Macular Degeneration at 4 Years Follow-up. Ophthalmol Sci. 2024 Mar 7;4(5):100510. doi: 10.1016/j.xops.2024.100510. eCollection 2024 Sep-Oct.
PubMed 38881600Muqit M, Mer YL, de Koo LO, Holz FG, Sahel JA, Palanker D. Prosthetic Visual Acuity with the PRIMA System in Patients with Atrophic Age-related Macular Degeneration at 4 years follow-up. medRxiv [Preprint]. 2023 Nov 13:2023.11.12.23298227. doi: 10.1101/2023.11.12.23298227.
PubMed 38014146
Study at a glance
From the registry record, last updated by the sponsor on 2 Apr 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Feasibility Study of Compensation for Blindness With the PRIMA System in Patients With Dry Age Related Macular Degeneration
- ClinicalTrials.gov ID
- NCT03333954
- Acronym / sponsor ID
- PRIMA FS / CIP-PRIMA-FS
- Conditions
- Dry Age-related Macular Degeneration
- Keywords
- atrophic macular degeneration, geographic atrophy, macular degeneration, dry macular degeneration, AMD, retina implant, retinal prosthesis, visual prosthesis
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 5 participants (actual)
- Lead sponsor
- Science CorporationIndustry (pharma, biotech, devices)
- Study start
- 6 Nov 2017 (actual)
- Primary completion
- 12 Dec 2024 (actual)
- Study completion
- 12 Dec 2024 (actual)
- First posted
- 7 Nov 2017 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
In this study, the principle functionality of the device will be tested in humans for the first time. The study will evaluate the extent to which patients with atrophic dry age related macular degeneration (AMD) have evoked light perception using the implant.
Detailed description
In this study subjects are provided with a PRIMA sub-retinal implant in one eye. A camera integrated in the external components of the implant captures visual information of the environment, this information is processed by a pocket processor and then transmitted via projected IR light onto the implant. The implant received the projected IR light and stimulates the nerve cells of the retina. Interim analysis will be performed at 6 months after implantation.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| PRIMA Bionic Vision System | Experimental | Device: PRIMA Bionic Vision SystemPRIMA Bionic Vision System |
Who may qualify
- Ages
- 60 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (9 listed)
- Is 60 years or older at the date of enrolment;
- Has a confirmed diagnosis of advanced dry age related macular degeneration with an atrophy size of at least 3 optic disc diameters;
- Has best corrected visual acuity of the study eye of logMAR 1.3 (20/400) or worse measured by ETDRS;
- Has no foveal perception measured by micro-perimetry in the study eye (≤ 4 dB on Opko scale or equivalent) ;
- Has a study eye that is able to perceive light;
Key exclusion criteria (28 listed)
- Has cataracts that may influence the visual function of the study eye;
- Has an aphakic study eye
- Had cataract surgery in the last 1 month;
- Active sub-macular choroidal neovascularization in the study eye;
- Has any disease (other than study allowed diseases) or condition that affects retinal function of the study eye (e.g., central retinal artery/vein occlusion, end-stage diabetic retinopathy, retinal detachment, infectious or inflammatory retinal disease, severe glaucoma, optic neuropathy, myopic chorio-retinal atrophy etc.);
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| PRIMA Bionic Vision SystemThe PRIMA Bionic Vision System is a device for treatment of patients who have lost their sight through outer retinal degenerative conditions of the eye such as atrophic dry age related macular degeneration. The PRIMA System is designed to provide partial restoration of the patient's visual function through electrical stimulation of the retinal neurons by a sub-retinally implanted stimulator that replace part of the degenerate photoreceptors | Device | PRIMA Bionic Vision System |
Primary outcome
Elicitation of perception
Time frame: 6 months after implantation
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Elicitation of perception
Time frame: 6 weeks after implantation
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Elicitation of perception
Time frame: 3 months after implantation
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Elicitation of perception
Time frame: 12 months after implantation
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Elicitation of perception
Time frame: 18 months after implantation
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Elicitation of perception
Time frame: 24 months after implantation
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
Elicitation of perception
Time frame: 36 months after implantation
Elicitation of visual perception by electrical stimulation of the PRIMA implant measured by Octopus Visual Field
3 secondary outcomes
Visual Acuity
Time frame: 18, 24 and 36 months after implantation if applicable
Letter Visual Acuity
Time frame: 48, 60 and 72 month after implantation
Quality of Live measured by IVI
Time frame: 48, 60 and 72 month after implantation
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 2 Apr 2026.
- Results publication: PubMed 35082313Palanker D, Le Mer Y, Mohand-Said S, Sahel JA. Simultaneous perception of prosthetic and natural vision in AMD patients. Nat Commun. 2022 Jan 26;13(1):513. doi: 10.1038/s41467-022-28125-x.
- Results publication: PubMed 36174540Muqit MMK, Mer YL, Holz FG, Sahel JA. Long-term observations of macular thickness after subretinal implantation of a photovoltaic prosthesis in patients with atrophic age-related macular degeneration. J Neural Eng. 2022 Oct 14;19(5):10.1088/1741-2552/ac9645. doi: 10.1088/1741-2552/ac9645.
- Results publication: PubMed 32249038Palanker D, Le Mer Y, Mohand-Said S, Muqit M, Sahel JA. Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration. Ophthalmology. 2020 Aug;127(8):1097-1104. doi: 10.1016/j.ophtha.2020.02.024. Epub 2020 Feb 25.
- Results publication: PubMed 38881600Muqit MMK, Le Mer Y, Olmos de Koo L, Holz FG, Sahel JA, Palanker D. Prosthetic Visual Acuity with the PRIMA Subretinal Microchip in Patients with Atrophic Age-Related Macular Degeneration at 4 Years Follow-up. Ophthalmol Sci. 2024 Mar 7;4(5):100510. doi: 10.1016/j.xops.2024.100510. eCollection 2024 Sep-Oct.
- Derived from this study: PubMed 38014146Muqit M, Mer YL, de Koo LO, Holz FG, Sahel JA, Palanker D. Prosthetic Visual Acuity with the PRIMA System in Patients with Atrophic Age-related Macular Degeneration at 4 years follow-up. medRxiv [Preprint]. 2023 Nov 13:2023.11.12.23298227. doi: 10.1101/2023.11.12.23298227.
- Science CorporationLink provided by the sponsor.
- Individual participant dataSharing planned: No
Related trials for Dry Age-related Macular Degeneration
RecruitingPhase 1/2
Autologous Transplantation of Induced Pluripotent Stem Cell-Derived Retinal Pigment Epithelium for Geographic Atrophy Associated With Age-Related Macular Degeneration
Dry Age-Related Macular Degeneration, Geographic Atrophy
Not yet recruiting
Safety and Clinical Performance of the LENTIS® MAX LS-313 MF80 Compared With the Monofocal L-313 in Cataract Patients With Late Age-Related Macular Degeneration: A Multicenter Comparative Clinical Investigation.
Cataract, AMD - Age-Related Macular Degeneration
Not yet recruiting
MacuMira Microcurrent Stimulation for Dark Adaptation in Dry Age-Related Macular Degeneration
Age-Related Macular Degeneration (AMD)
Active, not recruitingPhase 1/2
Study to Assess the Safety and Efficacy of OCU410 for Geographic Atrophy
Geographic Atrophy
Active, not recruitingPhase 1/2
Safety and Efficacy Study of OpRegen for Treatment of Advanced Dry-Form Age-Related Macular Degeneration
Age-Related Macular Degeneration
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing PRIMA Bionic Vision System in people with Dry Age-related Macular Degeneration, run by Science Corporation at 1 site in France.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 9 inclusion and 28 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 2 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Elicitation of perception (time frame: 6 months after implantation). The study lists 7 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03333954, which also lists 5 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Apr 2026.