Atrial FibrillationAIRNCT03277976
Pulmonary Vein Isolation Guided by Ablation Index (Ablation Index Registry Study)
An observational study of Atrial Fibrillation, run by Clinica Mediterranea at 1 site in Italy.
Trial summary
This is a prospective, multi-center, research study designed to evaluate the acute achievement of pulmonary vein (PV) isolation with ThermoCool SmartTouch (ST) and ThermoCool SmartTouch SF (STSF) catheter using the Ablation Index Module. Read more about this study
- Who is it for?
- Ages 18 to 80 yearsHealthy volunteers can take part
- Conditions the study is for
- Atrial Fibrillation
- What is being tested?
- PVI using ThermoCool® SmartTouch® Catheter and PVI using ThermoCool® SmartTouch SF® Catheter
- Type of treatment
- Medical device
- How many people
- 490 participants
- Where
- 1 siteItaly
- Study dates
- 29 Nov 2017to 28 Nov 2019
- How long will I take part?
- 12 Months
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Study population: Subjects with paroxysmal and persistent atrial fibrillation (AF) will undergo catheter ablation using commercially approved devices (mapping system and catheters).
Who may be able to join
- Subject is indicated for catheter ablation for paroxysmal AF;
- Subject is > 18 years old;
- Subject is < 80 years old ;
- Subject is on adequate anticoagulation therapy
Who cannot join
- Patients who had already undergo an AF ablation procedure;
- Patients with left ventricular ejection fraction < 35%
- Women of childbearing potential who are or might be pregnant
- Hematological contraindications to ionizing radiation exposure
- Presence of complex congenital heart disease, and cardiac surgery within 1 month from enrollment
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Pulmonary Vein Isolation Guided by Ablation Index
This is a prospective, multi-center, research study designed to evaluate the acute achievement of pulmonary vein (PV) isolation with ThermoCool SmartTouch (ST) and ThermoCool SmartTouch SF (STSF) catheter using the Ablation Index Module.
Read the detailed description
This is a prospective, multi-center, research study designed to evaluate the acute achievement of pulmonary vein (PV) isolation with ThermoCool SmartTouch (ST) and ThermoCool SmartTouch SF (STSF) catheter using the Ablation Index Module.
Subjects with paroxysmal and persistent atrial fibrillation (AF) will undergo catheter ablation using commercially approved devices (mapping system and catheters).
Patients will be followed up for 12 months to measure the recurrence of AF. This study is expected to start in September 2017 and to continue for approximately 26 months. It is anticipated that this study will require approximately 12 months for subject enrollment. Patients will be followed up for at least 12 months. Data analysis is expected to require approximately 2 months. At least 320 consecutive patients will be enrolled in the study centers. Patients will be divided in 4 groups and enrollment will stop when at least 80 patients will be enrolled in each group. The investigators evaluate two ablation catheters (ST and STSF) and two different ablation index settings (380 posterior - 500 anterior and 330 posterior - 450 anterior). Given that the rate of PV isolation with a standard wide antral circumferential ablation technique (WACA) is about 70%, the investigators want to test if one of two catheters or one of ablation index settings can increase the PV isolation rate of at least 10% (from 70% to 80%, 95% CI 75-85%).
Primary endpoint The primary objective of this study is to evaluate which ablation strategy increase the rate of WACA PV isolation, validated by mean of LASSO catheter, after first encirclement, from 70% to 80%.
Secondary endpoints Incidence of early PV reconnection 30 minutes after acute PV isolation. Difference in procedural and fluoroscopy time between the two groups. Incidence of AF recurrence during the blanking period (3-months after ablation).
Safety of the ablation procedure. At least 320 patients undergoing catheter ablation for paroxysmal or persistent AF will be enrolled.
Inclusion Criteria The following criteria must be met for subjects to be eligible for inclusion into the study Subject is indicated for catheter ablation for paroxysmal AF Subject is > 18 years old Subject is < 80 years old Subject is on adequate anticoagulation therapy
Exclusion Criteria The following criteria are exclusions for study participation Patients who had already undergo an AF ablation procedure Patients with left ventricular ejection fraction < 35% Women of childbearing potential who are or might be pregnant Hematological contraindications to ionizing radiation exposure Presence of complex congenital heart disease, and cardiac surgery within 1 month from enrollment
Patients will be screened in ambulatory and scheduled for AF ablation according to current guide lines. Ablation will be usually performed under effective oral anticoagulation. Anticoagulation could be withdrawn before admission, so as antiarrhythmic drugs will be removed before scheduled procedure. Patients in AF or with a CHA2DS2-VASc score ≥ 1 will undergo transesophageal echocardiography within 48 hours prior to the ablation. For all other patients transesophageal echocardiography is optional. Cardiac MRI or Cardiac CT scan could be executed as a reference for volume estimations obtained with the mapping system.
Ablation will be carried out under mild or conscious sedation, at least 2 femoral vein access will be obtained and in some patients 1 subclavian vein. One diagnostic catheter will be positioned in the coronary sinus. One or two transseptal accesses to the left atrium will be achieved using a standard approach. Then, the LASSO catheter and the ablation catheter (ST and STSF) will be placed in the left atrium. Heparin will be administered before the transseptal punctures to maintain an activated clotting time ≥ 300 seconds for the duration of the procedure. Left atrium mapping will be performed in sinus rhythm. Patients with atrial fibrillation at the beginning of the index procedure will undergo electrical cardioversion. After left atrium reconstruction the effective PV-left atrium electrical connection will be checked with LASSO. In all groups a wide antrum circumferential ablation aimed at PV isolation will be performed using contact force threshold range between 5-40 g (14), and the Ablation Index Module, with the following preset: respiration adjustment; stability range 3 mm, stability time 3 sec, force over time 25% of time, 3 g and ablation index thresholds: 500 for anterior wall and 380 for posterior wall or 450 for anterior wall and 330 for posterior wall; contiguity lesion 5-6 mm (15-16). The default power setting will be 30 W, with ranges of 20-40 W. At the end of the ablation effective PV isolation (entry and exit block), will be checked with LASSO catheter. After PV isolation will be achieved, the reconnection of the same vein will be evaluated after a 30 minute period from the initial isolation or after adenosine infusion or isoproterenol. If the vein reconnects to the atrium, the ablation will be directed to the gaps identified by the LASSO catheter. All patients will undergo a post-procedural ECG and, optional, an echocardiogram to exclude pericardial effusion or other acute complications. After ablation, patients will undertake regular follow-up assessments (scheduled at 3 months) including a detailed history, physical examination, 12-lead standard electrocardiography, and 24-h Holter monitoring. Patients who will not report any symptoms related to the previous arrhythmia during a supplementary detailed follow up (6-12 months subsequent to catheter ablation) will be considered free of arrhythmia recurrence
- Conditions
- Atrial Fibrillation
- Being tested
- PVI using ThermoCool® SmartTouch® Catheter, PVI using ThermoCool® SmartTouch SF® Catheter
- Keywords
- atrial fibrillation;, catheter ablation;, pulmonary vein isolation, ablation index
- Medical subject headings
- Atrial Fibrillation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
PVI using ThermoCool® SmartTouch® CatheterDevice
PVI using RFA, using ThermoCool® SmartTouch® Catheter (Biosense Webster Inc., CA, US), guided by Ablation Index
PVI using ThermoCool® SmartTouch SF® CatheterDevice
PVI using RFA, using ThermoCool® SmartTouch SF® Catheter (Biosense Webster Inc., CA, US), guided by Ablation Index
| Study group | Role | What they receive |
|---|---|---|
| ThermoCool SmartTouch 1 | In this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch Catheter and Ablation Index range: 380 for the posterior wall and 500 for the anterior wall Receives: Device: PVI using ThermoCool® SmartTouch® Catheter | |
| ThermoCool SmartTouch 2 | In this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch Catheter and Ablation Index range: 330 for the posterior wall and 450 for the anterior wall Receives: Device: PVI using ThermoCool® SmartTouch® Catheter | |
| ThermoCool SmartTouch SF 1 | In this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch SF Catheter and Ablation Index range: 330 for the posterior wall and 450 for the anterior wall Receives: Device: PVI using ThermoCool® SmartTouch SF® Catheter | |
| ThermoCool SmartTouch SF 2 | In this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch SF Catheter and Ablation Index range: 380 for the posterior wall and 500 for the anterior wall Receives: Device: PVI using ThermoCool® SmartTouch SF® Catheter |
What is being measured
The primary outcome is the main question the study is designed to answer.
The primary objective of this study is to evaluate which ablation strategy increase the rate of WACA PV isolation, validated by mean of LASSO catheter, after first encirclement, from 70% to 80%.
Measured: From the end of the WACA PV isolation up to 5 min after
Secondary outcomes (4)
Incidence of early PV reconnection 30 minutes after acute PV isolation.
Measured: Up to 30 min after the effective pulmonary vein isolation
Difference in procedural and fluoroscopy time between the two groups
Measured: From the beginning of the index procedure to the end of index procedure
Incidence of AF recurrence during the blanking period
Measured: Up to 3 months after the ablation procedure
Incidence of treatment-emergent adverse events.
Measured: Number of participants with treatment-related adverse events as assessed by CTCAE v4.0, from the index procedure to one-year follow-up
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted11 Sep 2017
- Study start29 Nov 2017
- Primary completion28 Sep 2018
- Study completion28 Nov 2019
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (4)Papers the sponsor has linked to this study.
- Other trials for Atrial FibrillationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 490 participants (actual)
- Target duration
- 12 Months
Sponsor and investigators
- Lead sponsor
- Clinica Mediterranea
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03277976
- Sponsor's protocol ID
- AIR Study
- Acronym
- AIR
- Status last verified
- Aug 2018
- First submitted
- 27 Jul 2017
- Last updated
- 5 Mar 2024
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Publications
El Haddad M, Taghji P, Phlips T, Wolf M, Demolder A, Choudhury R, Knecht S, Vandekerckhove Y, Tavernier R, Nakagawa H, Duytschaever M. Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force-Guided Pulmonary Vein Isolation: Identifying the Weakest Link in the Ablation Chain. Circ Arrhythm Electrophysiol. 2017 Apr;10(4):e004867. doi: 10.1161/CIRCEP.116.004867.
PubMed 28381417Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, Waktare JEP, Todd DM, Hall MCS, Snowdon RL, Modi S, Gupta D. Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace. 2017 May 1;19(5):775-783. doi: 10.1093/europace/euw105.
PubMed 27247002Das M, Wynn GJ, Morgan M, Lodge B, Waktare JE, Todd DM, Hall MC, Snowdon RL, Modi S, Gupta D. Recurrence of atrial tachyarrhythmia during the second month of the blanking period is associated with more extensive pulmonary vein reconnection at repeat electrophysiology study. Circ Arrhythm Electrophysiol. 2015 Aug;8(4):846-52. doi: 10.1161/CIRCEP.115.003095. Epub 2015 Jun 24.
PubMed 26108982Stabile G, Di Donna P, Schillaci V, Di Monaco A, Iuliano A, Caponi D, Urraro F, Solimene F, Grimaldi M, Scaglione M. Safety and efficacy of pulmonary vein isolation using a surround flow catheter with contact force measurement capabilities: A multicenter registry. J Cardiovasc Electrophysiol. 2017 Jul;28(7):762-767. doi: 10.1111/jce.13227. Epub 2017 Jun 21.
PubMed 28422368
Study at a glance
From the registry record, last updated by the sponsor on 5 Mar 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Pulmonary Vein Isolation Guided by Ablation Index
- ClinicalTrials.gov ID
- NCT03277976
- Acronym / sponsor ID
- AIR / AIR Study
- Conditions
- Atrial Fibrillation
- Keywords
- atrial fibrillation;, catheter ablation;, pulmonary vein isolation, ablation index
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 490 participants (actual)
- Lead sponsor
- Clinica MediterraneaUniversity, hospital or other
- Study start
- 29 Nov 2017 (actual)
- Primary completion
- 28 Sep 2018 (actual)
- Study completion
- 28 Nov 2019 (actual)
- First posted
- 11 Sep 2017 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a prospective, multi-center, research study designed to evaluate the acute achievement of pulmonary vein (PV) isolation with ThermoCool SmartTouch (ST) and ThermoCool SmartTouch SF (STSF) catheter using the Ablation Index Module.
Detailed description
This is a prospective, multi-center, research study designed to evaluate the acute achievement of pulmonary vein (PV) isolation with ThermoCool SmartTouch (ST) and ThermoCool SmartTouch SF (STSF) catheter using the Ablation Index Module.
Subjects with paroxysmal and persistent atrial fibrillation (AF) will undergo catheter ablation using commercially approved devices (mapping system and catheters).
Patients will be followed up for 12 months to measure the recurrence of AF. This study is expected to start in September 2017 and to continue for approximately 26 months. It is anticipated that this study will require approximately 12 months for subject enrollment. Patients will be followed up for at least 12 months. Data analysis is expected to require approximately 2 months. At least 320 consecutive patients will be enrolled in the study centers. Patients will be divided in 4 groups and enrollment will stop when at least 80 patients will be enrolled in each group. The investigators evaluate two ablation catheters (ST and STSF) and two different ablation index settings (380 posterior - 500 anterior and 330 posterior - 450 anterior). Given that the rate of PV isolation with a standard wide antral circumferential ablation technique (WACA) is about 70%, the investigators want to test if one of two catheters or one of ablation index settings can increase the PV isolation rate of at least 10% (from 70% to 80%, 95% CI 75-85%).
Primary endpoint The primary objective of this study is to evaluate which ablation strategy increase the rate of WACA PV isolation, validated by mean of LASSO catheter, after first encirclement, from 70% to 80%.
Secondary endpoints Incidence of early PV reconnection 30 minutes after acute PV isolation. Difference in procedural and fluoroscopy time between the two groups. Incidence of AF recurrence during the blanking period (3-months after ablation).
Safety of the ablation procedure. At least 320 patients undergoing catheter ablation for paroxysmal or persistent AF will be enrolled.
Inclusion Criteria The following criteria must be met for subjects to be eligible for inclusion into the study Subject is indicated for catheter ablation for paroxysmal AF Subject is > 18 years old Subject is < 80 years old Subject is on adequate anticoagulation therapy
Exclusion Criteria The following criteria are exclusions for study participation Patients who had already undergo an AF ablation procedure Patients with left ventricular ejection fraction < 35% Women of childbearing potential who are or might be pregnant Hematological contraindications to ionizing radiation exposure Presence of complex congenital heart disease, and cardiac surgery within 1 month from enrollment
Patients will be screened in ambulatory and scheduled for AF ablation according to current guide lines. Ablation will be usually performed under effective oral anticoagulation. Anticoagulation could be withdrawn before admission, so as antiarrhythmic drugs will be removed before scheduled procedure. Patients in AF or with a CHA2DS2-VASc score ≥ 1 will undergo transesophageal echocardiography within 48 hours prior to the ablation. For all other patients transesophageal echocardiography is optional. Cardiac MRI or Cardiac CT scan could be executed as a reference for volume estimations obtained with the mapping system.
Ablation will be carried out under mild or conscious sedation, at least 2 femoral vein access will be obtained and in some patients 1 subclavian vein. One diagnostic catheter will be positioned in the coronary sinus. One or two transseptal accesses to the left atrium will be achieved using a standard approach. Then, the LASSO catheter and the ablation catheter (ST and STSF) will be placed in the left atrium. Heparin will be administered before the transseptal punctures to maintain an activated clotting time ≥ 300 seconds for the duration of the procedure. Left atrium mapping will be performed in sinus rhythm. Patients with atrial fibrillation at the beginning of the index procedure will undergo electrical cardioversion. After left atrium reconstruction the effective PV-left atrium electrical connection will be checked with LASSO. In all groups a wide antrum circumferential ablation aimed at PV isolation will be performed using contact force threshold range between 5-40 g (14), and the Ablation Index Module, with the following preset: respiration adjustment; stability range 3 mm, stability time 3 sec, force over time 25% of time, 3 g and ablation index thresholds: 500 for anterior wall and 380 for posterior wall or 450 for anterior wall and 330 for posterior wall; contiguity lesion 5-6 mm (15-16). The default power setting will be 30 W, with ranges of 20-40 W. At the end of the ablation effective PV isolation (entry and exit block), will be checked with LASSO catheter. After PV isolation will be achieved, the reconnection of the same vein will be evaluated after a 30 minute period from the initial isolation or after adenosine infusion or isoproterenol. If the vein reconnects to the atrium, the ablation will be directed to the gaps identified by the LASSO catheter. All patients will undergo a post-procedural ECG and, optional, an echocardiogram to exclude pericardial effusion or other acute complications. After ablation, patients will undertake regular follow-up assessments (scheduled at 3 months) including a detailed history, physical examination, 12-lead standard electrocardiography, and 24-h Holter monitoring. Patients who will not report any symptoms related to the previous arrhythmia during a supplementary detailed follow up (6-12 months subsequent to catheter ablation) will be considered free of arrhythmia recurrence
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Target follow-up
- 12 Months
- Number of arms
- 4
| Arm | Type | Receives |
|---|---|---|
| ThermoCool SmartTouch 1 | – | Device: PVI using ThermoCool® SmartTouch® CatheterIn this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch Catheter and Ablation Index range: 380 for the posterior wall and 500 for the anterior wall |
| ThermoCool SmartTouch 2 | – | Device: PVI using ThermoCool® SmartTouch® CatheterIn this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch Catheter and Ablation Index range: 330 for the posterior wall and 450 for the anterior wall |
| ThermoCool SmartTouch SF 1 | – | Device: PVI using ThermoCool® SmartTouch SF® CatheterIn this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch SF Catheter and Ablation Index range: 330 for the posterior wall and 450 for the anterior wall |
| ThermoCool SmartTouch SF 2 | – | Device: PVI using ThermoCool® SmartTouch SF® CatheterIn this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch SF Catheter and Ablation Index range: 380 for the posterior wall and 500 for the anterior wall |
Who may qualify
- Ages
- 18 to 80 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
- Study population
- Subjects with paroxysmal and persistent atrial fibrillation (AF) will undergo catheter ablation using commercially approved devices (mapping system and catheters).
Key inclusion criteria (4 listed)
- Subject is indicated for catheter ablation for paroxysmal AF;
- Subject is > 18 years old;
- Subject is < 80 years old ;
- Subject is on adequate anticoagulation therapy
Key exclusion criteria (5 listed)
- Patients who had already undergo an AF ablation procedure;
- Patients with left ventricular ejection fraction < 35%
- Women of childbearing potential who are or might be pregnant
- Hematological contraindications to ionizing radiation exposure
- Presence of complex congenital heart disease, and cardiac surgery within 1 month from enrollment
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| PVI using ThermoCool® SmartTouch® CatheterPVI using RFA, using ThermoCool® SmartTouch® Catheter (Biosense Webster Inc., CA, US), guided by Ablation Index | Device | ThermoCool SmartTouch 1, ThermoCool SmartTouch 2 |
| PVI using ThermoCool® SmartTouch SF® CatheterPVI using RFA, using ThermoCool® SmartTouch SF® Catheter (Biosense Webster Inc., CA, US), guided by Ablation Index | Device | ThermoCool SmartTouch SF 1, ThermoCool SmartTouch SF 2 |
Primary outcome
The primary objective of this study is to evaluate which ablation strategy increase the rate of WACA PV isolation, validated by mean of LASSO catheter, after first encirclement, from 70% to 80%.
Time frame: From the end of the WACA PV isolation up to 5 min after
4 secondary outcomes
Incidence of early PV reconnection 30 minutes after acute PV isolation.
Time frame: Up to 30 min after the effective pulmonary vein isolation
Difference in procedural and fluoroscopy time between the two groups
Time frame: From the beginning of the index procedure to the end of index procedure
Incidence of AF recurrence during the blanking period
Time frame: Up to 3 months after the ablation procedure
Incidence of treatment-emergent adverse events.
Time frame: Number of participants with treatment-related adverse events as assessed by CTCAE v4.0, from the index procedure to one-year follow-up
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 5 Mar 2024.
- Background: PubMed 28381417El Haddad M, Taghji P, Phlips T, Wolf M, Demolder A, Choudhury R, Knecht S, Vandekerckhove Y, Tavernier R, Nakagawa H, Duytschaever M. Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force-Guided Pulmonary Vein Isolation: Identifying the Weakest Link in the Ablation Chain. Circ Arrhythm Electrophysiol. 2017 Apr;10(4):e004867. doi: 10.1161/CIRCEP.116.004867.
- Background: PubMed 27247002Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, Waktare JEP, Todd DM, Hall MCS, Snowdon RL, Modi S, Gupta D. Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace. 2017 May 1;19(5):775-783. doi: 10.1093/europace/euw105.
- Results publication: PubMed 26108982Das M, Wynn GJ, Morgan M, Lodge B, Waktare JE, Todd DM, Hall MC, Snowdon RL, Modi S, Gupta D. Recurrence of atrial tachyarrhythmia during the second month of the blanking period is associated with more extensive pulmonary vein reconnection at repeat electrophysiology study. Circ Arrhythm Electrophysiol. 2015 Aug;8(4):846-52. doi: 10.1161/CIRCEP.115.003095. Epub 2015 Jun 24.
- Results publication: PubMed 28422368Stabile G, Di Donna P, Schillaci V, Di Monaco A, Iuliano A, Caponi D, Urraro F, Solimene F, Grimaldi M, Scaglione M. Safety and efficacy of pulmonary vein isolation using a surround flow catheter with contact force measurement capabilities: A multicenter registry. J Cardiovasc Electrophysiol. 2017 Jul;28(7):762-767. doi: 10.1111/jce.13227. Epub 2017 Jun 21.
Related trials for Atrial Fibrillation
Active, not recruiting
Horizon 360 Protocol for the Treatment of Paroxysmal Atrial Fibrillation With the Sphere-360™ Catheter and Affera™ Mapping and Ablation System (Horizon 360)
Paroxysmal AF
Active, not recruitingObservational study
Concomitant Left Atrial Appendage Closure and Pulsed Field Ablation-Asia
Concomitant Procedures, Atrial Fibrillation
Active, not recruiting
CONVERGE Post-Approval Study (PAS)
Chronic Atrial Fibrillation
Recruiting
Early Closure of Left Atrial Appendage for Patients With Atrial Fibrillation and Ischemic Stroke Despite Anticoagulation Therapy
Ischemic Stroke, Atrial Fibrillation
RecruitingPhase 2
Safety in Adult Participants With Atrial Fibrillation Who Are Treated With Anticoagulation
Atrial Fibrillation (AF)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Atrial Fibrillation, run by Clinica Mediterranea at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 5 Mar 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
The primary objective of this study is to evaluate which ablation strategy increase the rate of WACA PV isolation, validated by mean of LASSO catheter, after first encirclement, from 70% to 80%. (time frame: From the end of the WACA PV isolation up to 5 min after). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03277976, which also lists 4 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Mar 2024.