TemperatureNCT03264833

Accuracy and Precision Comparison of Temptraq

An observational study of Temperature, run by The Cleveland Clinic.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Purpose The purpose of this feasibility study is to assess the accuracy and precision of the Temp-Traq thermometer for monitoring body temperature in adult patients under three conditions (hypothermia, normothermia, and hyperthermia). Specific Aims 1. Read more about this study

Who is it for?
Ages 21 years and older
Conditions the study is for
Temperature
What is being tested?
TempTraq
How many people
60 participants
Where
No sites listed yet
Study dates
15 Dec 2016to 1 Oct 2017
Phase
Observational
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 years and older
  • All sexes
  • Adult, Older adult

Study population: To address the specific aims of this study the investigators will identify at least 40 patients who have a pulmonary artery (PA) catheter in place (patients in intensive care units).

Who may be able to join

  • Inclusion Criteria Adult patient (male or female) in intensive care unit who will have a PA catheter in place for at least the next 8 hours; and who have no visible skin condition to the axillary region upon inspection by the research nurse are eligible for this study

Who cannot join

  • Patients younger than 21
  • Patients who will not have a PA catheter in place for the next 8 hours
  • Patients who have a visible skin condition to the axillary region upon inspection by the research nurse
  • Patients who will be going for procedures or for some reason will not be available for the 6 hours of the study

About this study

Official title: Accuracy and Precision Test of TempTraq® Compared to Pulmonary Artery Catheter for Monitoring Temperature in Adults in Intensive Care Unit

Purpose The purpose of this feasibility study is to assess the accuracy and precision of the Temp-Traq thermometer for monitoring body temperature in adult patients under three conditions (hypothermia, normothermia, and hyperthermia).

Specific Aims

  1. To assess the accuracy of the Temp-Traq thermometer as compared to a gold standard (Core temp measured by Pulmonary Artery Catheter)
  2. To assess the precision of the Temp-Traq thermometer over repeated measures
  3. To determine if accuracy \&/or precision is consistent in three conditions (hypothermia, normothermia, or hyperthermia)
Read the detailed description

Design A repeated measures within-group comparative design will be used for this study.

Sample/Setting To address the specific aims of this study the investigators will identify patients who have a pulmonary artery (PA) catheter in place (patients in intensive care units). Letters of support are attached from the unit managers where the study will take place (see attached).

Procedure Once a patient is identified, the researcher will record basic demographic data (see data collection form attached) and the axillary area will be assessed for visible signs of any skin conditions. If there are no visible signs of a skin condition the researcher will apply the Temp-Traq thermometer to the right or left axilla of the subject and record the location of the placement. The researcher will record both the PA and Temp-Traq recordings of subject's temperature (taken at the same time) on the data collection form (see attachment) at four data points; baseline (5 minutes post application of Temp-Traq) and every two hours (+/- 15 minutes) after baseline X 3. Previous testing of the TempTraq® on children and healthy adults has not resulted in any adverse skin reactions. However, as this is a new thermometer format and there is not a significant body of literature on potential skin reactions, the investigators will assess skin before and after application. Thus, at the end of the last reading the Temp-Traq thermometer will be removed and the skin will be assessed for erythema. If erythema is present the patient's nurse and physician will be notified by the researcher.

Protection of Human Subjects Since non-invasive temperature monitoring poses no risk to patients and is part of usual care and since the investigators will not collect or record any protected health information (PHI), written informed consent will not be sought. Patients will be identified by their study ID number only. The data will be collected by a registered nurse data collector familiar with the intensive care setting and data will be stored in a locked file cabinet in the researchers locked office. Temperature data for the Temp-Traq is collected through the Temp-Traq Application (AP) which will be placed on a Cleveland Clinic Approved and encrypted i-pad. Once the study is completed and all data has been transferred to the study database, the Temp-Traq application and all of its data will be deleted from the i-pad.

Analysis The investigators will use the TOST (Two One Sided t-tests) method for equivalence testing. This method requires a defined range of mean differences between two test methods, an estimate of the precision of the measurement of the two systems, and an estimate of the size of the possible difference in the means of the two methods under consideration. The TOST null hypothesis is a joint null hypothesis that the mean measurement differences between the two methods is greater than a critical lower bound and less than a critical upper bound. If the null is rejected then the investigators can conclude that the absolute difference of the means between Temp Traq and PA catheter falls within the specified range. It was determined that to be considered equivalent with respect to accuracy the mean measurements of the two methods should be within ± 0.2 degrees of each other. Precision tests for Temp-Traq thermometer using accepted ASTM test methods for various combinations of temperature and humidity provided a range of measurement variation between .0000435 and .019928 with a mean of 0.000254500. If the investigators assume both test methods exhibit the same levels of precision then the variance of the differences between their two means will reduce to two times the values listed previously. This will result in estimates of the standard deviations of the mean differences of .0093, .032, and .063 respectively.

The two methods for body temperature that will be examined are core temperature measurements with a PA catheter and temperature measurements using the Temp-Traq (measured in degree Celsius simultaneously). Paired temperature measurements for both methods will be taken simultaneously every 2 hours for a 6 hour period. This will provide 4 repeated temperature measures per patient. The simultaneous measurements within a given patient should exhibit a high degree of correlation. If .7 is chosen as the lower bound for the correlation between the paired readings (higher correlations would result in an estimate of fewer patient samples thus the choice of .7 is conservative) and if the average standard deviation of the mean of the differences is used as an estimate of the expected variability, then it would be possible to declare measurement equivalence for a difference of ±.19 with a sample size of 40 patients. This assumes the ASTM measurements of instrument variation are representative of the within patient variance. Given the vagaries of patient-to-patient this may be too optimistic an estimate.

A sample size of at least 40 patients will provide 80% or greater power for testing for equivalence between methods where the mean difference is .1 or less for up to a ten-fold increase in the estimates of the variability of the differences based on the ASTM precision measures and for a mean difference of .15 for up to a five-fold increase in these same measures. If the sample size is 40 then the power for the test of equivalence, where the difference is .15 and the standard deviation is a ten-fold increase, is 35%. Agreement testing: The Bland-Altman test will be used to test the agreement of the two methods. This test will permit a check for significance of bias between the two measures (the average difference between the two measures) as well as a check for significant trending over the range of the measurements. If the bias is significant then the results of the two differ by an overall offset in their measurements. If the trending (slope of the regression line) is significant then the difference between the two measurements changes as their magnitude changes which means the two methods are not in agreement.

The only measurements of instrument precision are those provided by the ASTM assessment. It is reasonable to assume the within patient measurement variation will be greater than the measurements from the controlled testing. A sample size of at least 40 patients is, from a statistical standpoint, a reasonable number and this sample size provides acceptable power for a mean difference of .1 for a ten-fold increase in the estimate of minimum test variability. This sample size will also provide enough data for the Bland-Altman test for agreement. Because this is a repeated measures test and even one missing measurement will impact the results, the investigators plan to over-sample in order to assure the study has the power to answer the questions posed.

Conditions
Temperature
Being tested
TempTraq

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • TempTraqDiagnostic test

    sensor-based external thermometer withmonitoring capability

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Temperature Comparison

    Core temperature monitoring (degree Celsius) with temp-Traq thermometer compared to Pulmonary Artery (PA) catheter

    Measured: Multiple time points up to 6 hours post thermometer placement

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Aug 2017
  2. Study start15 Dec 2016
  3. Primary completion1 Sep 2017
  4. Study completion1 Oct 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
60 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03264833
Sponsor's protocol ID
NCT-03264833
Status last verified
Jan 2026
First submitted
2 Feb 2017
Last updated
12 Feb 2026
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: IPD will not be shared

Publications

  • Eliades, A, Stoner, K. and Frisone, J. (unpublished paper) Use of skin patch device to obtain temperature measurements

  • Farnell S, Maxwell L, Tan S, Rhodes A, Philips B. Temperature measurement: comparison of non-invasive methods used in adult critical care. J Clin Nurs. 2005 May;14(5):632-9. doi: 10.1111/j.1365-2702.2004.00916.x.

    PubMed 15840078
  • Lawson L, Bridges EJ, Ballou I, Eraker R, Greco S, Shively J, Sochulak V. Accuracy and precision of noninvasive temperature measurement in adult intensive care patients. Am J Crit Care. 2007 Sep;16(5):485-96.

    PubMed 17724246
  • Pinsky MR, Vincent JL. Let us use the pulmonary artery catheter correctly and only when we need it. Crit Care Med. 2005 May;33(5):1119-22. doi: 10.1097/01.ccm.0000163238.64905.56.

    PubMed 15891346
  • Sund-Levander M, Grodzinsky E. Assessment of body temperature measurement options. Br J Nurs. 2013 Aug 8-Sep 12;22(15):880, 882-8. No abstract available.

    PubMed 24052967

Questions about this trial

What is this clinical trial studying?

An observational study of Temperature, run by The Cleveland Clinic.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 12 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 12 Feb 2026). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Temperature Comparison (time frame: Multiple time points up to 6 hours post thermometer placement). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03264833, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Feb 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in