Dysfunctional Dialysis Arteriovenous FistulaNCT03189667

Drug Coated Balloons vs Plain Balloons for the Management of Dysfunctional Dialysis Fistula

A study testing Vessel preparation with angioplasty, Plain balloon angioplasty and Drug coated balloon angioplasty in people with Dysfunctional Dialysis Arteriovenous Fistula, run by King Abdullah International Medical Research Center at 1 site in Saudi Arabia.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Compare the effectiveness of drug-coated balloons to plain balloon angioplasty in reducing stenosis rates in dialysis arteriovenous fistulas (AVFs). Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Vessel preparation with angioplasty, Plain balloon angioplasty and Drug coated balloon angioplasty
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
23 participants
Where
1 siteSaudi Arabia
Study dates
15 Oct 2017to 5 Feb 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • >18 year old
  • Dysfunctional dialysis fistula
  • Radiocephalic
  • Brachiocephalic
  • Brachiobasilic
  • Clinical criteria for diagnosis of dysfunctional fistula:
Show all 13Show fewer
  • Swelling of the fistula limb
  • Prolonged bleeding after withdrawing access needles
  • Abnormal pulsations or weak thrill.
  • Functional criteria for the diagnosis of dysfunctional criteria:
  • Arteriovenous fistula is unable to deliver dialysis blood flow (Qb) of equal to or more than 300 ml/min and/or access recirculation of more than 10% on at least two occasions,
  • A rising trend of venous pressure or excessive negative arterial pressure, and/or unable to deliver a Kt/v of 1.2 or more.
  • Non-thrombosed

Who cannot join

  • Dysfunctional arteriovenous (AV) grafts
  • Thrombosed fistulas
  • Intra-stent stenosis
  • Stenoses not responding to balloon angioplasty and requiring stenting.
  • Stenosis less than 50%
  • Surgical intervention that excludes the treatment segment from the access circuit
Show all 11Show fewer
  • Systemic or local (to the fistula) infection treated for less than 10 days prior to the study procedure
  • Location of isolated stenosis central to the thoracic inlet.
  • Women who are breastfeeding, pregnant or are intending to become pregnant
  • Known hypersensitivity or contraindication to contrast medium which cannot be adequately premeditated.
  • Sensitivities to heparin, aspirin, other anticoagulant/antiplatelet therapies, and/or paclitaxel

Trial locations and contacts

1 site in 1 country.

Saudi Arabia1 site
  • King ABdulaziz Medical City

    Riyadh, 11426

Other trials in Saudi Arabia

About this study

Compare the effectiveness of drug-coated balloons to plain balloon angioplasty in reducing stenosis rates in dialysis arteriovenous fistulas (AVFs).

Read the detailed description

Objectives of the Study:

Hypothesis: Drug-coated balloons improve functional and patency outcomes of failing/dysfunctional hemodialysis fistulas compared to plain uncoated balloons

Aim of the Study:

Compare the effectiveness of drug-coated balloons to plain balloon angioplasty in reducing stenosis rates in dialysis AVFs.

Specific Objectives:

Primary functional endpoint: Access circuit patency based on functional criteria at 12 month.

Primary safety endpoint: Peri procedural complication rate

Secondary endpoints:

  • Technical success (<30% residual stenosis without postdilation)
  • Access circuit dysfunction free survival (Time to event) based on functional criteria
  • Target lesion restenosis free survival (Time to event) (in case of new lesion causes circuit dysfunction)
Being tested
Vessel preparation with angioplasty, Plain balloon angioplasty, Drug coated balloon angioplasty

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Vessel preparation with angioplastyDevice

    Vessel preparation with Pre dilatation:

    • All lesions to be predilated with high pressure balloons until waist is obliterated.
    • At least two minutes dilatation.
    • Balloon sizing: not to exceed the average diameter of adjacent normal appearing non-aneurysmal segments by more than 25%.
    • Multiple lesions:
    • To be treated with single balloon if possible.
    • To be treated with multiple inflation if cannot be covered with single balloon.
  • Plain balloon angioplastyDevice

    Plain balloon angioplasty

    • Vessel treatment with additional Plain balloon angioplasty:
    • Inflation to nominal pressure for at least 1 minute.
    • Balloon size: similar to predilation balloon.
  • Drug coated balloon angioplastyDevice

    Lutonix® Drug Coated Balloon: The balloon is coated with a specialized formulation that includes the drug, paclitaxel. The paclitaxel coating is evenly distributed across the working length of the balloon at a surface concentration of 2 μg/mm2. The key functional characteristic of the formulation is to allow for release of paclitaxel to the tissue of the vascular wall during inflation.

    • Inflation to nominal pressure for at least 1 minute.
    • Balloon size: similar to the predilation balloon.
    • New drug coated balloon will be required for each lesion.
Study groups in NCT03189667
Study groupRoleWhat they receive
Drug coated balloon angioplastyExperimental* Vessel preparation with Pre dilatation * Vessel treatment with Drug-coated balloon
Receives: Device: Vessel preparation with angioplasty; Device: Drug coated balloon angioplasty
Plain balloon angioplastyActive comparator* Vessel preparation with Pre dilatation * Vessel treatment with additional Plain balloon angioplasty:
Receives: Device: Vessel preparation with angioplasty; Device: Plain balloon angioplasty

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. AVF circuit patency

    Dialysis adequacy to be assessed based on functional criteria

    Measured: 12 month

Secondary outcomes (4)
  1. Technical success

    <30% residual stenosis without postdilation

    Measured: intra procedural

  2. Access circuit dysfunction free survival

    Time to event based on functional criteria

    Measured: 12 month

  3. Target lesion restenosis free survival

    Time to event in case of new lesion causes circuit dysfunction

    Measured: 12 month

  4. Number of participants with treatment-related adverse events

    Number of participants with treatment-related adverse events as assessed by the Society of Interventional Radiology Clinical Practice Guidelines

    Measured: 12 month following the procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 Jun 2017
  2. Study start15 Oct 2017
  3. Primary completion5 Feb 2019
  4. Study completion5 Feb 2019

Why it stopped: slow recruitment and recent concerns of safety of Paclitaxel coated balloons and associated increased risk death

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Open label randomized clinical trial
Masking
None (open label)
Enrolment
23 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03189667
Sponsor's protocol ID
RC16/035/R
Status last verified
Apr 2019
First submitted
1 Jun 2017
Last updated
1 May 2019
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Vessel preparation with angioplasty, Plain balloon angioplasty and Drug coated balloon angioplasty in people with Dysfunctional Dialysis Arteriovenous Fistula, run by King Abdullah International Medical Research Center at 1 site in Saudi Arabia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 13 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 1 May 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Saudi Arabia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: slow recruitment and recent concerns of safety of Paclitaxel coated balloons and associated increased risk death). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

AVF circuit patency (time frame: 12 month). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.