Aortic Dissection Type BNCT03033771
Dragon Study Europe
A study testing Implantation with the Multilayer Flow Modulator (MFM) in people with Aortic Dissection Type B, run by Cardiatis at 4 sites in 2 countries.
Trial summary
Dragon Study Europe is an international, multicenter, prospective, non-randomized study. It is designed to evaluate safety and performance of the MFM for the treatment of chronic type B aortic dissection. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Aortic Dissection Type B
- What is being tested?
- Implantation with the Multilayer Flow Modulator (MFM)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 27 participants
- Where
- 4 sitesin 2 countries
- Study dates
- Jan 2016to Dec 2029
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age over 18
- Life expectancy > 12 months
- Informed consent understood, signed and patient agrees to all follow-up visits
- Chronic type B aortic dissection must be presenting with at least one of the following factors:
- Uncontrollable hypertension
- Persistent back/chest pain despite medical treatment
Show all 12Show fewer
- Expansion of aortic diameter (false lumen and total diameter)
- With risk of progression, i.e. partial thrombosis of the false lumen
- Healthy proximal and distal landing zone
- Adequate arterial anatomy to perform EVAR by MFM
- Healthy branches and collaterals (no stenosis or previously treated by angioplasty)
- The patient must be available for the appropriate follow-up visits for the study duration
Who cannot join
- Stage 4 or 5 Renal Insufficiency as per K/DOQI clinical practice guidelines for chronic kidney disease (GFR < 29ml/min/1.73m²)
- Dissection or aneurysm rupture, impending or contained rupture
- Aortic root aneurysm
- Pleural effusion untreated at the procedure time
- Prior all surgical procedure within 30 days unless procedure is in preparation for device implantation or planned within 30 days post stent deployment
- Myocardial infarction or cerebral vascular accident within 6 weeks of treatment
Show all 20Show fewer
- Presence/suspicion of connective tissue disorders, for example, Marfan or Ehlers-Danlos etc.
- Contraindications to the anticoagulant or/ and antiplatelet medications
- Thrombocytopenia
- Allergic reaction to a contrast agent
- Patient with undergoing or planned chemotherapy
- History of bleeding disorder (coagulopathy) or thrombophilia
- Patient with atrial fibrillation who are under anticoagulation therapy
- Presence/suspicion of infection (for example: mycotic aorta)
- The use of the MFM with stent-grafts or previously implanted stent-grafts
- Pregnant or breastfeeding woman
- Patients included in another clinical study
- Severe left ventricular dysfunction
- Significant arrhythmias
- Severe valvular disease
Trial locations and contacts
4 sites in 2 countries.
4 sites in 2 countries
Romania2 sites
Sanador Hospital
Bucharest
European Hospital Polisano
Sibiu, 550172
About this study
Official title: Evaluation of the Safety and Performance of the Multilayer Flow Modulator (MFM) for the Treatment of Chronic Type B Aortic Dissection
Dragon Study Europe is an international, multicenter, prospective, non-randomized study. It is designed to evaluate safety and performance of the MFM for the treatment of chronic type B aortic dissection. About 35 patients in up to 11 countries will be enrolled and screened per the protocol-required inclusion, exclusion criteria, in order to obtain 30 completed patients. For early demonstration of safety and performance, an interim analysis report will be performed after all patients included will complete their 6-month follow-up.
The study purpose is to determine the safety and performance of the MFM for the endovascular treatment of chronic type B aortic dissection. It should be noted that the MFM has CE mark approval for aortic and peripheral artery aneurysms treatment.
Read the detailed description
Aortic dissection (AD) is the surging of blood through a tear in the aortic intima with separation of the intima and media and creation of a false lumen.
The dissection may occur anywhere along the aorta and extend proximally or distally into other arteries. It occurs most commonly at the proximal ascending aorta (within 5 cm of the aortic valve) or the descending thoracic aorta (just beyond the origin of the left subclavian artery).
The passage of blood through the false channel can lead to complications such as spinal cord injury (paraplegia), lack of blood supply to the intestines (mesenteric ischemia) or lower extremities. The flow of blood in the false channel can cause these complications by pinching/narrowing off the flow of blood into the branches off the aorta. Aortic dissection always occurs in the setting of pre-existing degeneration of the aortic media. Causes include connective tissue disorders and injury. Atherosclerotic risk factors, notably hypertension, contribute in more than two thirds of patients.
Evidence of dissection is found in 1 to 3% of all autopsies. Population-based studies suggest that the incidence of AD is approximately 5-30 cases per million people per year. The diagnosis of AD is missed in 40% of cases on initial presentation, and 30% of AD are first diagnosed on post mortem exams.
African-Americans, men, the elderly, and people with hypertension are especially at risk. Peak incidence occurs at age 50 to 65 or, for patients with congenital connective tissue disorders (eg, Marfan syndrome, Ehlers-Danlos syndrome), at age 20 to 40.
Aortic dissections are classified anatomically, The DeBakey classification system is most widely used.
- Type I (50% of dissections): These dissections start in the ascending aorta and extend at least to the aortic arch and sometimes beyond.
- Type II (35%): These dissections start in and are confined to the ascending aorta.
- Type III (15%): These dissections start in the descending thoracic aorta just beyond the origin of the left subclavian artery and extend distally or, less commonly, proximally.
The Stanford system is simpler.
- Type A: These dissections involve the ascending aorta.
- Type B: These dissections are confined to the descending thoracic aorta. Patients with uncomplicated type B dissection have a 30-day mortality of 10%. Conversely, those who develop an ischemic leg, renal failure, visceral ischemia, or contained rupture often require urgent aortic repair; their mortality is 20% by day 2, and 25% by day 30.
For uncomplicated acute and chronic type B dissection, several series have shown that drug treatment alone can result in 78% three year survival after discharge from hospital. Current guidelines deem that the medical management remains the gold standard for uncomplicated type B aortic dissection and this benchmark is difficult to surpass. However, the medical treatment alone may put some patients at risk of serious complications such as progressive aortic enlargement, poor blood flow to some organs or the extremities, and aortic rupture.
The development of complicated dissection-defined by the presence of visceral or limb ischaemia, rupture, refractory pain, or uncontrollable hypertension-is the key factor that determines both intervention and outcome for patients with type B dissection.
Surgery is virtually always indicated if dissection involves the proximal aorta (type A dissection) and for complicated aortic dissection. In addition surgery may also be best for acute distal dissections in patients with Marfan syndrome. The goal of surgery is to obliterate entry into the false channel and reconstitute the aorta with a synthetic graft. Predictors of conventional surgery poor outcome include hypotension, renal failure, age > 70, abrupt onset of chest pain, pulse deficit, and ST-segment elevation on Electrocardiography.
TEVAR (Thoracic Endovascular Aortic Repair) aims to cover the primary entry tear in the descending aorta, resulting in a reduction of flow and pressure in the false lumen and formation of false lumen thrombosis.
Covered stent or bare stent reconstruction of branch vessels and re-entry tears, with false lumen thrombosis and remodelling. For acute (first 2 weeks) type B aortic dissection, the pooled early mortality rate was 6.4% with medical treatment and increased to 10.2% with TEVAR and 17.5% with open surgery, mostly for complicated cases. IRAD (International Registry of Acute Aortic Dissection) reported an in-hospital mortality rate of 32% for surgically treated individuals, 7% for those managed with endovascular techniques, and 10% for those managed with medical therapy alone. The in-hospital mortality rate of patients with complicated type B dissection was significantly higher after open surgery (33%) than after endovascular treatment (11%). This demonstrated that with appropriate use of endovascular stent graft placement, patients with complicated dissection enjoyed an improved prognosis, eventually similar to patients with an uncomplicated stable course requiring only medical management.
The presence of a rigid chronic dissection flap and multiple chronic re-entries often located distal to the treated thoracic aorta could have a negative impact on outcome. For patients with dissection extending into the abdominal aorta, TEVAR is seldom a definitive treatment, and the continued perfusion of the distal lumen could create further problems. The endovascular approach is associated with less morbidity and mortality. However, the longterm efficacy of an endovascular approach to preventing long-term aortic related death is still unclear.
Paraplegia and retrograde dissection are two of the most dreaded complications after TEVAR for type B dissection. Retrograde dissection occurs in 1% to 4% of patients and is more prevalent when the proximal landing zone is in the arch.
Spinal cord ischemia rates are lower after TEVAR than after open repair, but this complication remains a concern and has been reported in up to 4% of patients treated with TEVAR for chronic dissection. This result compare favourably with open repair, which has a reported 7% to 36% paraplegia risk.
Additionally, a significant proportion (12%-60%) of patients experience disease progression during follow-up after TEVAR, and thus requires further surgical procedures.
The Multilayer Flow Modulator® (MFM) (Cardiatis, Isnes, Belgium) has CE mark approval for peripheral/visceral and aortic aneurysms involving at least one branch. The aortic MFM is widely used for the thoracoabdominal aneurysm treatment. The clinical benefits of this technology have been suggested in studies about treatments of thoracoabdominal aneurysm, type B dissection, juxtarenal aortic aneurysm and peripheral artery aneurysm (celiac, hepatic, renal, iliac, subclavian). Also the prospective multicenter registry of peripheral and visceral aneurysms and the prospective multicenter STRATO Trial of TAAA, show good results at 12-month follow-up.
This MFM is an uncovered, self-expanding wire mesh with high radial force and flexibility. It is designed to modulate blood-flow dynamics by relieving local peak wall shear stress (PWSS), achieving stabilization of aneurysm-sac pressure and preserving side-branch patency.
In this study, the MFM® safety and performance will be evaluated in the use for the endovascular treatment of the chronic type B aortic dissection. Of course all patients were diagnosed according to standard of care and thoughtful decision before treatment/study intervention has to be made. In all cases the treating physician(s) shall consider and discuss alternative treatments with each individual patient before starting screening and enrolling into this study. Hence, once MFM® treatment within this study has been identified as feasible and desired mode of treatment with a state-of-the-art device with a beneficial risk benefit profile.
In general, treatment in this study will follow the routine course of an endovascular treatment of aortic pathologies, i.e. classical stenting procedures. Surgery, or stent-grafts are virtually always indicated if dissection involves the proximal aorta (type A dissection) and for complicated aortic dissection. In addition, surgery/stent-grafts may also be best for acute distal dissections in patients with congenital tissue disorders (non-exhaustively, such as Marfan, Loeys-Dietz or Ehler Danlos syndromes).
- Conditions
- Aortic Dissection Type B
- Being tested
- Implantation with the Multilayer Flow Modulator (MFM)
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Implantation with the Multilayer Flow Modulator (MFM)Device
Also called MFM, Multilayer Flow Modulator
Endovascular implantation with the MFM
| Study group | Role | What they receive |
|---|---|---|
| Treatment | Experimental | Patients presenting with chronic type B aortic dissection will have the MFM implanted. Receives: Device: Implantation with the Multilayer Flow Modulator (MFM) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Re-establishment of the flow inside the true lumen
the re-establishment of the flow inside the true lumen will be evaluated using medical imagery. Data will be compaired to pre-op imaregy, and will be presented as a percentage of patient with true lumen repressurization compared to baseline.
Measured: 30 days
Keeping all branches patent
the patency of branches emerging from the treated portion of the aorta will be evaluated and compared to pre-op data. Data will be presented as a percentage of branches patent per total number of branches involved in the diseased and treated portion of the aorta.
Measured: 30 days
Re-establishment of the flow inside the true lumen
the re-establishment of the flow inside the true lumen will be evaluated using medical imagery. Data will be compared to pre-op imaregy, and will be presented as a percentage of patient with true lumen repressurization compared to baseline.
Measured: 12 months
Keeping all branches patent
the re-establishment of the flow inside the true lumen will be evaluated using medical imagery. Data will be compaired to pre-op imaregy, and will be presented as a percentage of patient with true lumen repressurization compared to baseline.
Measured: 12 months
Secondary outcomes (9)
Mortality at 30 days
Percentage of patients deceased at 30 days
Measured: 30 days
Number of Serious Adverse Events
Measured: 30 days, 12 months, 24 months and 36 months
Technical Success
Successful delivery and deployment of the MFM
Measured: The technical success is evaluated/recorded post-procedure and presented in the 12 months report
Procedural/in-hospital evaluations (Anesthesia time)
descriptive statistics on Anesthesia time (min)
Measured: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report.
Procedural/in-hospital evaluations (Fluoroscopy time)
Descriptive Statistics on fluoroscopy time (min)procedure time; time to hospital discharge
Measured: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report.
Procedural/in-hospital evaluations (Contrast Volume)
Descriptive Statistics on contrast volume (ml)
Measured: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report
Procedural/in-hospital evaluations (Estimated Blood loss)
Descriptive Statistics on contrast Estimated Blood loss (ml)
Measured: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report.
Procedural/in-hospital evaluations (procedure time)
Descriptive Statistics on procedure time (min)
Measured: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report.
Procedural/in-hospital evaluations (time to hospital discharge)
Descriptive Statistics on time to hospital discharge (days).
Measured: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted27 Jan 2017 (estimated)
- Study startJan 2016
- Primary completionDec 2022
- Study completionDec 2029 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Aortic Dissection Type BStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Dragon Study Europe is an international, multicenter, prospective, non-randomized study. It is designed to evaluate safety and performance of the MFM for the treatment of chronic type B aortic dissection. About 35 patients in up to 11 countries will be enrolled and screened per the protocol-required inclusion, exclusion criteria, in order to obtain 30 completed patients. The main interim analysis, aiming at the early demonstration of safety and performance, will be performed after all patients included will complete their 6-month follow-up. A preliminary interim analysis will be performed on the first patients enrolled (15 completed patients) and with their 6-months follow-up available.
- Masking
- None (open label)
- Enrolment
- 27 participants (actual)
Sponsor and investigators
- Lead sponsor
- Cardiatis
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Victor Costache, MD PhD, Principal investigator, Sanador Hospital, Bucharest, Romania
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03033771
- Sponsor's protocol ID
- 04-2015
- Status last verified
- Feb 2024
- First submitted
- 19 Jan 2017
- Last updated
- 7 Feb 2024
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 7 Feb 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of the Safety and Performance of the Multilayer Flow Modulator (MFM) for the Treatment of Chronic Type B Aortic Dissection
- ClinicalTrials.gov ID
- NCT03033771
- Acronym / sponsor ID
- 04-2015
- Conditions
- Aortic Dissection Type B
- Study type
- Interventional
- Recruitment status
- Active, not recruiting
- Enrolment
- 27 participants (actual)
- Lead sponsor
- CardiatisIndustry (pharma, biotech, devices)
- Study start
- Jan 2016 (actual)
- Primary completion
- Dec 2022 (actual)
- Study completion
- Dec 2029 (estimated)
- First posted
- 27 Jan 2017 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Dragon Study Europe is an international, multicenter, prospective, non-randomized study. It is designed to evaluate safety and performance of the MFM for the treatment of chronic type B aortic dissection. About 35 patients in up to 11 countries will be enrolled and screened per the protocol-required inclusion, exclusion criteria, in order to obtain 30 completed patients. For early demonstration of safety and performance, an interim analysis report will be performed after all patients included will complete their 6-month follow-up.
The study purpose is to determine the safety and performance of the MFM for the endovascular treatment of chronic type B aortic dissection. It should be noted that the MFM has CE mark approval for aortic and peripheral artery aneurysms treatment.
Detailed description
Aortic dissection (AD) is the surging of blood through a tear in the aortic intima with separation of the intima and media and creation of a false lumen.
The dissection may occur anywhere along the aorta and extend proximally or distally into other arteries. It occurs most commonly at the proximal ascending aorta (within 5 cm of the aortic valve) or the descending thoracic aorta (just beyond the origin of the left subclavian artery).
The passage of blood through the false channel can lead to complications such as spinal cord injury (paraplegia), lack of blood supply to the intestines (mesenteric ischemia) or lower extremities. The flow of blood in the false channel can cause these complications by pinching/narrowing off the flow of blood into the branches off the aorta. Aortic dissection always occurs in the setting of pre-existing degeneration of the aortic media. Causes include connective tissue disorders and injury. Atherosclerotic risk factors, notably hypertension, contribute in more than two thirds of patients.
Evidence of dissection is found in 1 to 3% of all autopsies. Population-based studies suggest that the incidence of AD is approximately 5-30 cases per million people per year. The diagnosis of AD is missed in 40% of cases on initial presentation, and 30% of AD are first diagnosed on post mortem exams.
African-Americans, men, the elderly, and people with hypertension are especially at risk. Peak incidence occurs at age 50 to 65 or, for patients with congenital connective tissue disorders (eg, Marfan syndrome, Ehlers-Danlos syndrome), at age 20 to 40.
Aortic dissections are classified anatomically, The DeBakey classification system is most widely used.
- Type I (50% of dissections): These dissections start in the ascending aorta and extend at least to the aortic arch and sometimes beyond.
- Type II (35%): These dissections start in and are confined to the ascending aorta.
- Type III (15%): These dissections start in the descending thoracic aorta just beyond the origin of the left subclavian artery and extend distally or, less commonly, proximally.
The Stanford system is simpler.
- Type A: These dissections involve the ascending aorta.
- Type B: These dissections are confined to the descending thoracic aorta. Patients with uncomplicated type B dissection have a 30-day mortality of 10%. Conversely, those who develop an ischemic leg, renal failure, visceral ischemia, or contained rupture often require urgent aortic repair; their mortality is 20% by day 2, and 25% by day 30.
For uncomplicated acute and chronic type B dissection, several series have shown that drug treatment alone can result in 78% three year survival after discharge from hospital. Current guidelines deem that the medical management remains the gold standard for uncomplicated type B aortic dissection and this benchmark is difficult to surpass. However, the medical treatment alone may put some patients at risk of serious complications such as progressive aortic enlargement, poor blood flow to some organs or the extremities, and aortic rupture.
The development of complicated dissection-defined by the presence of visceral or limb ischaemia, rupture, refractory pain, or uncontrollable hypertension-is the key factor that determines both intervention and outcome for patients with type B dissection.
Surgery is virtually always indicated if dissection involves the proximal aorta (type A dissection) and for complicated aortic dissection. In addition surgery may also be best for acute distal dissections in patients with Marfan syndrome. The goal of surgery is to obliterate entry into the false channel and reconstitute the aorta with a synthetic graft. Predictors of conventional surgery poor outcome include hypotension, renal failure, age > 70, abrupt onset of chest pain, pulse deficit, and ST-segment elevation on Electrocardiography.
TEVAR (Thoracic Endovascular Aortic Repair) aims to cover the primary entry tear in the descending aorta, resulting in a reduction of flow and pressure in the false lumen and formation of false lumen thrombosis.
Covered stent or bare stent reconstruction of branch vessels and re-entry tears, with false lumen thrombosis and remodelling. For acute (first 2 weeks) type B aortic dissection, the pooled early mortality rate was 6.4% with medical treatment and increased to 10.2% with TEVAR and 17.5% with open surgery, mostly for complicated cases. IRAD (International Registry of Acute Aortic Dissection) reported an in-hospital mortality rate of 32% for surgically treated individuals, 7% for those managed with endovascular techniques, and 10% for those managed with medical therapy alone. The in-hospital mortality rate of patients with complicated type B dissection was significantly higher after open surgery (33%) than after endovascular treatment (11%). This demonstrated that with appropriate use of endovascular stent graft placement, patients with complicated dissection enjoyed an improved prognosis, eventually similar to patients with an uncomplicated stable course requiring only medical management.
The presence of a rigid chronic dissection flap and multiple chronic re-entries often located distal to the treated thoracic aorta could have a negative impact on outcome. For patients with dissection extending into the abdominal aorta, TEVAR is seldom a definitive treatment, and the continued perfusion of the distal lumen could create further problems. The endovascular approach is associated with less morbidity and mortality. However, the longterm efficacy of an endovascular approach to preventing long-term aortic related death is still unclear.
Paraplegia and retrograde dissection are two of the most dreaded complications after TEVAR for type B dissection. Retrograde dissection occurs in 1% to 4% of patients and is more prevalent when the proximal landing zone is in the arch.
Spinal cord ischemia rates are lower after TEVAR than after open repair, but this complication remains a concern and has been reported in up to 4% of patients treated with TEVAR for chronic dissection. This result compare favourably with open repair, which has a reported 7% to 36% paraplegia risk.
Additionally, a significant proportion (12%-60%) of patients experience disease progression during follow-up after TEVAR, and thus requires further surgical procedures.
The Multilayer Flow Modulator® (MFM) (Cardiatis, Isnes, Belgium) has CE mark approval for peripheral/visceral and aortic aneurysms involving at least one branch. The aortic MFM is widely used for the thoracoabdominal aneurysm treatment. The clinical benefits of this technology have been suggested in studies about treatments of thoracoabdominal aneurysm, type B dissection, juxtarenal aortic aneurysm and peripheral artery aneurysm (celiac, hepatic, renal, iliac, subclavian). Also the prospective multicenter registry of peripheral and visceral aneurysms and the prospective multicenter STRATO Trial of TAAA, show good results at 12-month follow-up.
This MFM is an uncovered, self-expanding wire mesh with high radial force and flexibility. It is designed to modulate blood-flow dynamics by relieving local peak wall shear stress (PWSS), achieving stabilization of aneurysm-sac pressure and preserving side-branch patency.
In this study, the MFM® safety and performance will be evaluated in the use for the endovascular treatment of the chronic type B aortic dissection. Of course all patients were diagnosed according to standard of care and thoughtful decision before treatment/study intervention has to be made. In all cases the treating physician(s) shall consider and discuss alternative treatments with each individual patient before starting screening and enrolling into this study. Hence, once MFM® treatment within this study has been identified as feasible and desired mode of treatment with a state-of-the-art device with a beneficial risk benefit profile.
In general, treatment in this study will follow the routine course of an endovascular treatment of aortic pathologies, i.e. classical stenting procedures. Surgery, or stent-grafts are virtually always indicated if dissection involves the proximal aorta (type A dissection) and for complicated aortic dissection. In addition, surgery/stent-grafts may also be best for acute distal dissections in patients with congenital tissue disorders (non-exhaustively, such as Marfan, Loeys-Dietz or Ehler Danlos syndromes).
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Dragon Study Europe is an international, multicenter, prospective, non-randomized study. It is designed to evaluate safety and performance of the MFM for the treatment of chronic type B aortic dissection. About 35 patients in up to 11 countries will be enrolled and screened per the protocol-required inclusion, exclusion criteria, in order to obtain 30 completed patients. The main interim analysis, aiming at the early demonstration of safety and performance, will be performed after all patients included will complete their 6-month follow-up. A preliminary interim analysis will be performed on the first patients enrolled (15 completed patients) and with their 6-months follow-up available.
| Arm | Type | Receives |
|---|---|---|
| Treatment | Experimental | Device: Implantation with the Multilayer Flow Modulator (MFM)Patients presenting with chronic type B aortic dissection will have the MFM implanted. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (12 listed)
- Age over 18
- Life expectancy > 12 months
- Informed consent understood, signed and patient agrees to all follow-up visits
- Chronic type B aortic dissection must be presenting with at least one of the following factors:
- Healthy proximal and distal landing zone
Key exclusion criteria (20 listed)
- Stage 4 or 5 Renal Insufficiency as per K/DOQI clinical practice guidelines for chronic kidney disease (GFR < 29ml/min/1.73m²)
- Dissection or aneurysm rupture, impending or contained rupture
- Aortic root aneurysm
- Pleural effusion untreated at the procedure time
- Prior all surgical procedure within 30 days unless procedure is in preparation for device implantation or planned within 30 days post stent deployment
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Implantation with the Multilayer Flow Modulator (MFM)Also: MFM, Multilayer Flow ModulatorEndovascular implantation with the MFM | Device | Treatment |
Primary outcome
Re-establishment of the flow inside the true lumen
Time frame: 30 days
the re-establishment of the flow inside the true lumen will be evaluated using medical imagery. Data will be compaired to pre-op imaregy, and will be presented as a percentage of patient with true lumen repressurization compared to baseline.
Keeping all branches patent
Time frame: 30 days
the patency of branches emerging from the treated portion of the aorta will be evaluated and compared to pre-op data. Data will be presented as a percentage of branches patent per total number of branches involved in the diseased and treated portion of the aorta.
Re-establishment of the flow inside the true lumen
Time frame: 12 months
the re-establishment of the flow inside the true lumen will be evaluated using medical imagery. Data will be compared to pre-op imaregy, and will be presented as a percentage of patient with true lumen repressurization compared to baseline.
Keeping all branches patent
Time frame: 12 months
the re-establishment of the flow inside the true lumen will be evaluated using medical imagery. Data will be compaired to pre-op imaregy, and will be presented as a percentage of patient with true lumen repressurization compared to baseline.
9 secondary outcomes
Mortality at 30 days
Time frame: 30 days
Number of Serious Adverse Events
Time frame: 30 days, 12 months, 24 months and 36 months
Technical Success
Time frame: The technical success is evaluated/recorded post-procedure and presented in the 12 months report
Procedural/in-hospital evaluations (Anesthesia time)
Time frame: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report.
Procedural/in-hospital evaluations (Fluoroscopy time)
Time frame: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report.
Procedural/in-hospital evaluations (Contrast Volume)
Time frame: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report
Procedural/in-hospital evaluations (Estimated Blood loss)
Time frame: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report.
Procedural/in-hospital evaluations (procedure time)
Time frame: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report.
Procedural/in-hospital evaluations (time to hospital discharge)
Time frame: The Procedural/in-hospital evaluation are recorded during hospital stay and collected data is presented in the 12 months report.
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 7 Feb 2024.
- Individual participant dataSharing planned: No
Related trials for Aortic Dissection Type B
Recruiting
IMPRoving Outcomes in Vascular DisEase - Aortic Dissection
Type B Aortic Dissection
Recruiting
EXtensive mulTilayer stEnt treatmeNt in Aortic disSectiOn
Type B Aortic Dissection
Not yet recruitingObservational study
Type B Aortic Dissection Quality Control Platform
Endovascular Surgery, Medical Quality
Recruiting
WeFlow-EndoSeal™ Aorta Vascular Plug System for the Treatment of Stanford Type B Aortic Dissection
Aortic Dissection Type B
Enrolling by invitationObservational study
Outcomes of Aortic Dissection Repair
Type A Aortic Dissection, Ascending Aortic Dissection
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Victor Costache, MD PhD principal investigator
Sanador Hospital, Bucharest, Romania
4 sites in 2 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Implantation with the Multilayer Flow Modulator (MFM) in people with Aortic Dissection Type B, run by Cardiatis at 4 sites in 2 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 12 inclusion and 20 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 7 Feb 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 4 sites in Bulgaria, Romania. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Re-establishment of the flow inside the true lumen (time frame: 30 days). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Feb 2024.