Diagnostic Accuracy of On-line Quantitative Flow Ratio (QFR). FAVOR II Europe-Japan

An observational study of Coronary Artery Disease, run by Aarhus University Hospital Skejby at 10 sites in 7 countries.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Quantitative Flow Ratio (QFR) is a novel method for evaluating the functional significance of coronary stenosis. QFR is assessed by calculation of the pressure in the vessel based on two angiographic projections. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Artery Disease
What is being tested?
QFR (observational)
How many people
329 participants
Where
10 sitesin 7 countries
Study dates
22 Feb 2017to 1 Jun 2018
Phase
Observational
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients with stable angina pectoris admitted for coronary angiography due to high risk of significant coronary stenosis

Who may be able to join

  • Stable angina pectoris or secondary evaluation of stenosis after acute MI
  • Age > 18 years
  • Able to provide signed informed consent
  • Angiographic inclusion criteria:
  • Indication for FFR in at least one stenosis:
  • Diameter stenosis of 30%-90% by visual estimate
  • Reference vessel size > 2 mm in stenotic segment by visual estimate

Who cannot join

  • Myocardial infarction within 72 hours
  • Severe asthma or severe chronic obstructive pulmonary disease
  • Severe heart failure (NYHA≥III)
  • S-creatinine>150µmol/L or GFR<45 ml/kg/1.73m2
  • Allergy to contrast media or adenosine
  • Atrial fibrillation
Show all 18Show fewer
  • Angiographic exclusion criteria:
  • Lesion specific
  • Below 30% and above 90% diameter stenosis by visual estimate.
  • Reference size of vessel below 2 mm by visual estimation.
  • Ostial LMCA lesions
  • Ostial RCA lesions
  • Distal LMCA lesions in combination with proximal Cx lesions
  • Other bifurcation stenosis with lesions on both sides of a major shift (>1mm) in reference diameter Angiographic quality
  • Poor image quality precluding contour detection
  • Good contrast filling not possible
  • Severe overlap of stenosed segments
  • Severe tortuosity of target vessel

Trial locations and contacts

10 sites in 7 countries.

10 sites in 7 countries

Italy3 sites
  • Azienda ospedaliera Sant'Anna e S. sebastiano di Caserta

    Caserta

  • Azienda Ospedaliero-Universitaria di Ferrara, University of Ferrara

    Ferrara, 44124

  • Ospedale dell'Angelo di Mestre

    Mestre, 30174

Other trials in Italy

Germany2 sites
  • Elizabeth Krankenhaus Essen

    Essen

  • Universitätsklinikum Gießen

    Giessen, 35392

Other trials in Germany

Denmark1 site
  • Aarhus University Hspital

    Aarhus N, 8200

Other trials in Denmark

France1 site
  • Institut Cardiovasculaire Paris Sud Massy

    Massy

Other trials in France

Japan1 site
  • Gifu Heart Center

    Gifu

Other trials in Japan

Netherlands1 site
  • HagaZiekenhuis

    The Hague, 2545

Other trials in Netherlands

United Kingdom1 site
  • Golden Jubilee National Hospital

    Glasgow, G81 4DY

Other trials in United Kingdom

About this study

Official title: Diagnostic Accuracy of On-line Quantitative Flow Ratio. Functional Assessment by Virtual Online Reconstruction (The FAVOR II Europe-Japan Study)

Quantitative Flow Ratio (QFR) is a novel method for evaluating the functional significance of coronary stenosis. QFR is assessed by calculation of the pressure in the vessel based on two angiographic projections. The purpose of the FAVOR II study is to evaluate the diagnostic accuracy of on-line QFR compared to 2D Quantitative Coronary Angiography (QCA) with FFR as gold standard.

Read the detailed description

Background:

Patients at high risk of having one or more coronary stenosis are evaluated routinely by invasive coronary angiography (CAG). Lesions are often quantified by QCA, but fractional flow reserve is increasingly used to assess functional significance of identified stenosis. FFR is assessed during CAG by advancing a wire with a pressure transducer towards the stenosis and measure the ratio in pressure between the two sides of the stenosis during medical induced maximum blood flow (hyperaemia).

The solid evidence for FFR evaluation of coronary stenosis and the relative simplicity in performing the measurements have supported adoption of an FFR based strategy in many centers but the need for interrogating the stenosis by a pressure wire, the cost of the wire, and the drug inducing hyperaemia limits more widespread adoption.

Quantitative Flow Ratio is a novel method for evaluating the functional significance of coronary stenosis by calculation of the pressure drop in the vessel based on two angiographic projections.

The FAVOR I study (Tu et al.), showed promising results for core laboratory QFR analysis in selected patients.

The purpose of the FAVOR II study is to evaluate the feasibility and diagnostic precision of in-procedure QFR during CAG in comparison to QCA with FFR as gold standard for physiological lesion evaluation.

Hypothesis: QFR has superior sensitivity and specificity for detection of functional significant lesions in comparison to QCA with FFR as gold standard

Methods: Prospective, observational, multicenter study with inclusion of 310 patients.

Patients with indication for FFR are enrolled. At least two angiographic projections are acquired during resting conditions. QFR is calculated in-procedure using the Medis Suite application and simultaneously to the operator performing the FFR measurement. The QFR observer is blinded to the FFR measurement.

QFR is reassessed off-line by the Interventional Coronary Imaging Core Laboratory, Aarhus University, Denmark, blinded to FFR and in-procedure QFR results.

FFR is assessed by core laboratory reading, blinded to QFR results. All data are entered and stored in a protected and logged trial management system (TrialPartner, Aarhus University, Denmark).

Being tested
QFR (observational)
Keywords
Fractional Flow Reserve, Quantitative Coronary Analysis, Stable coronary artery disease, Angina pectoris
Medical subject headings
Coronary Artery Disease, Angina Pectoris

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • QFR (observational)Other

    QFR assessment by Medis Suite, Medis medical imaging B.V., The Netherlands

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Sensitivity: Proportion of Patients With Positive QFR of FFR Positive Patients (True Positives) Compared to Proportion of Patients With Positive Percentual Diameter Stenosis (DS%) Assessed by 2D QCA of FFR Positive Patients (True Positives)

    Positive FFR is defined as FFR≤0.80. Positive QFR is defined as QFR≤0.80. Positive DS% is defined as DS% > 50%

    Measured: 1 hour

  2. Specificity: Proportion of Patients With Negative QFR of FFR Negative Patients (True Negatives) Compared to Proportion of Patients With Negative DS% Assessed by 2D QCA of FFR Negative Patients (True Negatives)

    Negative FFR is defined as FFR>0.80. Negative QFR is defined as QFR>0.80. Negative DS% is defined as DS% ≤ 50%.

    Measured: 1 hour

Secondary outcomes (14)
  1. Percentage of Patients With Successful QFR in Patients With Successful FFR (Feasibility)

    Measured: 1 hour

  2. Proportion of Patients With Positive QFR of FFR Positive Patients (True Positives) (Sensitivity)

    Positive FFR is defined as FFR≤0.80. Positive QFR is defined as QFR≤0.80

    Measured: 1 hour

  3. Proportion of Patients With Negative QFR of FFR Negative Patients (True Negatives) (Specificity)

    Negative FFR is defined as FFR>0.80. Negative QFR is defined as QFR>0.80

    Measured: 1 hour

  4. Proportion of Patients With Positive FFR (True Positives) of Patients With Positive QFR (Positive Predictive Value)

    Positive FFR is defined as FFR≤0.80. Positive QFR is defined as QFR≤0.80

    Measured: 1 hour

  5. Proportion of Patients With Negative FFR (True Negatives) of Patients With Negative QFR (Negative Predictive Value)

    Negative FFR is defined as FFR>0.80. Negative QFR is defined as QFR>0.80

    Measured: 1 hour

  6. Diagnostic Performance of QFR in Comparison to FFR Reported as Positive and Negative Likelihood Ratio

    Positive likelihood ratio is defined as sensitivity/(1-specificity). Negative likelihood ratio is defined as (1-sensitivty)/specificity

    Measured: 1 hour

  7. Diagnostic Grey Zone Calculation. QFR Limits for Achieving 95% Sensitivity and Specificity in Comparison to FFR

    QFR limits to yield 95% sensitivity and specificity. The QFR limits are identified by Area under the receiver operating curve analysis.

    QFR limits are defined as the numerical QFR ratios (0-1.00).

    Measured: 1 hour

  8. Diagnostic Accuracy of TIMI-flow Based QFR in Comparison to 2D QCA (>50% Diameter Stenosis)

    Comparison of proportion of participants correctly classified by QFR and 2D QCA using FFR as reference standard.

    Diagnostic accuracy is defined as (true positives + false negatives) / (true positives+false positives+true negatives+false negatives).

    Positive FFR is defined as FFR≤0.80. Positive QFR is defined as QFR≤0.80. Negative FFR is defines as FFR>0.80. Negative QFR is defines as QFR>0.80. Positive 2D QCA is defined as 2D-QCA % percent diameter stenosis >50. Negative 2D QCA is defined as 2D-QCA % diameter stenosis≤50.

    Measured: 1 hour

  9. Participants With Myocardial Infarction (Number of Patients)

    Peri-procedural myocardial infarction

    Measured: 1 day

  10. All-cause Mortality (Number of Patients)

    Peri-procedural mortality

    Measured: 1 day

  11. Time to FFR

    Time from starting preparations to do FFR (e.g. ordering assistants to prepare pressure wire, adenosine infusion etc.) to FFR value is obtained and drift has been verified to be within the prespecified limits

    Measured: 1 hour

  12. Time to QFR After Receiving Angiographic Images

    Time from first image evaluation on QFR computer until TIMI frame count based QFR value is obtained

    Measured: 1 hour

  13. Contrast Use

    Volume of contrast for total procedure

    Measured: 1 hour

  14. Fluoroscopy Time

    Fluoroscopy time for total procedure

    Measured: 1 hour

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Nov 2016 (estimated)
  2. Study start22 Feb 2017
  3. Primary completion17 Oct 2017
  4. Study completion1 Jun 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
329 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02959814
Sponsor's protocol ID
1-10-72-219-16
Acronym
FAVOR II EJ
Status last verified
Dec 2019
First submitted
7 Nov 2016
Last updated
13 Jan 2020
Data monitoring committee
Yes
Individual data sharing
Undecided

Publications

  • Tu S, Westra J, Yang J, von Birgelen C, Ferrara A, Pellicano M, Nef H, Tebaldi M, Murasato Y, Lansky A, Barbato E, van der Heijden LC, Reiber JHC, Holm NR, Wijns W; FAVOR Pilot Trial Study Group. Diagnostic Accuracy of Fast Computational Approaches to Derive Fractional Flow Reserve From Diagnostic Coronary Angiography: The International Multicenter FAVOR Pilot Study. JACC Cardiovasc Interv. 2016 Oct 10;9(19):2024-2035. doi: 10.1016/j.jcin.2016.07.013.

    PubMed 27712739
  • Westra J, Andersen BK, Campo G, Matsuo H, Koltowski L, Eftekhari A, Liu T, Di Serafino L, Di Girolamo D, Escaned J, Nef H, Naber C, Barbierato M, Tu S, Neghabat O, Madsen M, Tebaldi M, Tanigaki T, Kochman J, Somi S, Esposito G, Mercone G, Mejia-Renteria H, Ronco F, Botker HE, Wijns W, Christiansen EH, Holm NR. Diagnostic Performance of In-Procedure Angiography-Derived Quantitative Flow Reserve Compared to Pressure-Derived Fractional Flow Reserve: The FAVOR II Europe-Japan Study. J Am Heart Assoc. 2018 Jul 6;7(14):e009603. doi: 10.1161/JAHA.118.009603.

    PubMed 29980523

Questions about this trial

What is this clinical trial studying?

An observational study of Coronary Artery Disease, run by Aarhus University Hospital Skejby at 10 sites in 7 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 18 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 13 Jan 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 10 sites in Italy, Germany, Denmark, France, Japan and 2 more countries. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 13 Jan 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Sensitivity: Proportion of Patients With Positive QFR of FFR Positive Patients (True Positives) Compared to Proportion of Patients With Positive Percentual Diameter Stenosis (DS%) Assessed by 2D QCA of FFR Positive Patients (True Positives) (time frame: 1 hour). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02959814, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Jan 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in