Brain ImagingNCT02927327
Clinical Evaluation Of MP26 Features in Adults
A study testing Zero Echo Time (ZTE) scan for head attenuation and Q.Static (Q. MRAC) for respiratory motion correction in people with Brain Imaging and Whole Body Imaging, run by GE Healthcare at 1 site in United States.
Trial summary
The purpose of the study is to collect representative clinical images (head and whole-body scans) of demonstrated diagnostic quality using the next-generation SIGNA PET/MR device equipped with investigational software components in adult population. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Brain Imaging, Whole Body Imaging
- What is being tested?
- Zero Echo Time (ZTE) scan for head attenuation and Q.Static (Q. MRAC) for respiratory motion correction
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 61 participants
- Where
- 1 siteUnited States
- Study dates
- Nov 2016to 20 Sep 2017
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Are adults (aged 18 or older);
- Have preexisting clinical indication for PET/CT or PET/MR with radiotracer injection (for subjects that will undergo ZTE procedures, a preexisting clinical indication for PET/CT is required);
- Are able to undergo PET/MR within the tracer validity time frame after radiotracer injection;
- Can hear without assistive devices and have necessary mental capacity to follow study instructions;
- Are willing and able to provide written informed consent;
- Are considered eligible for MRI and PET exams, according to site institutional safety policies.
Who cannot join
- Were previously enrolled in the study;
- If female, are pregnant or of undetermined pregnancy status;
- Cannot fit safely in the device (>55 cm axial diameter or >227 kgs body weight);
- Have implants or attached medical devices that could be unsafe for MRI;
- Have medical conditions or require urgent care that could make it unsafe to participate
Trial locations and contacts
1 site in 1 country.
About this study
The purpose of the study is to collect representative clinical images (head and whole-body scans) of demonstrated diagnostic quality using the next-generation SIGNA PET/MR device equipped with investigational software components in adult population. The images and summary data from this study are intended for use in regulatory submission.
Read the detailed description
Primary Objective: To demonstrate diagnostic image quality of image sets with ZTE MRAC and Q Static (Q. MRAC) for SIGNA PET/MR in representative clinical cases of the general imaging population.
Secondary Objective(s): To verify diagnostic acceptability, ease of use, and functionality of ZTE MRAC and Q Static (Q. MRAC) for SIGNA PET/MR at clinical sites.
Safety Objective(s): To collect information about safety events and device issues.
- Conditions
- Brain Imaging, Whole Body Imaging
- Being tested
- Zero Echo Time (ZTE) scan for head attenuation, Q.Static (Q. MRAC) for respiratory motion correction
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Zero Echo Time (ZTE) scan for head attenuationDevice
The GE SIGNA PET/MR MP26 software platform includes the zero echo time (ZTE) scan for head attenuation and Q.Static. The ZTE MR software feature has the potential to enable better visualization of bones, including those in the head, by employing optimal head attenuation correction in PET/MR.
PET/MR ZTE MRAC
Q.Static (Q. MRAC) for respiratory motion correctionDevice
An improved Q.Static feature with Q. MRAC, where phase matching the MRAC with the quiescent phase is employed to get more accurate attenuation correction for our Q.Static PET images.
PET/MR Q Static (Q. MRAC)
| Study group | Role | What they receive |
|---|---|---|
| PET/MR ZTE MRAC | Experimental | PET/MR zero echo time (ZTE) scan for head attenuation and Q.Static . PET/MR ZTE MRAC images to be acquired for post-processing and reader assessment.
Zero Echo Time (ZTE) scan for head attenuation Receives: Device: Zero Echo Time (ZTE) scan for head attenuation |
| PET/MR Q Static (Q. MRAC) | Experimental | Q.Static (Q. MRAC) for respiratory motion correction. PET/MR Q Static (Q. MRAC) images to be acquired for post-processing and reader assessment.
PET/MR Q Static (Q. MRAC) Receives: Device: Q.Static (Q. MRAC) for respiratory motion correction |
What is being measured
The primary outcome is the main question the study is designed to answer.
Diagnostic Image Quality
scored on a 5-pt Likert scale:
- Unacceptable
- Poor
- Acceptable
- Good
- Excellent
Measured: through study completion, an average of 2 months
Secondary outcomes (3)
Determination of Diagnostic Acceptability
Site level determination of diagnostic acceptability (Y/N) based on consensus between radiologist(s) and nuclear medicine physician(s) at the site. Diagnostic acceptability in the form of binary responses (Y/N) were collected from 61 subjects who completed the study.
Measured: through study completion, an average of 2 months
Ease of Use Per Procedure Rated on a 5-pt Likert Scale Score
Ease of use ratings, based on a 5-point Likert scale (e.g. 1=unacceptable, 2=poor, 3=acceptable, 4=good, 5=excellent), were collected from the population of subjects who completed the study.
Measured: through study completion, an average of 2 months
Number of Participants Reporting "Yes" On All Binary Performance Scale Questions
The number of participants reporting "yes" on a binary performance scale (Y/N) were collected.
Measured: through study completion, an average of 2 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted7 Oct 2016 (estimated)
- Study startNov 2016
- Primary completion20 Sep 2017
- Study completion20 Sep 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for Brain ImagingStudies of the same condition, open and under way.
- More trials run by GE HealthcareThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Non-randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 61 participants (actual)
Sponsor and investigators
- Lead sponsor
- GE Healthcare
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Tibor Duliskovich, M.D., Study director, GE Healthcare, Medical Monitor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02927327
- Sponsor's protocol ID
- 114.03-2016-GES-0001
- Status last verified
- Dec 2018
- First submitted
- 4 Oct 2016
- Last updated
- 6 Dec 2018
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 6 Dec 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Evaluation Of MP26 Features in Adults
- ClinicalTrials.gov ID
- NCT02927327
- Acronym / sponsor ID
- 114.03-2016-GES-0001
- Conditions
- Brain Imaging, Whole Body Imaging
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 61 participants (actual)
- Lead sponsor
- GE HealthcareIndustry (pharma, biotech, devices)
- Study start
- Nov 2016
- Primary completion
- 20 Sep 2017 (actual)
- Study completion
- 20 Sep 2017 (actual)
- First posted
- 7 Oct 2016 (estimated)
- Results
- Posted 6 Dec 2018
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of the study is to collect representative clinical images (head and whole-body scans) of demonstrated diagnostic quality using the next-generation SIGNA PET/MR device equipped with investigational software components in adult population. The images and summary data from this study are intended for use in regulatory submission.
Detailed description
Primary Objective: To demonstrate diagnostic image quality of image sets with ZTE MRAC and Q Static (Q. MRAC) for SIGNA PET/MR in representative clinical cases of the general imaging population.
Secondary Objective(s): To verify diagnostic acceptability, ease of use, and functionality of ZTE MRAC and Q Static (Q. MRAC) for SIGNA PET/MR at clinical sites.
Safety Objective(s): To collect information about safety events and device issues.
Study design
- Primary purpose
- Other
- Allocation
- Non-randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| PET/MR ZTE MRAC | Experimental | Device: Zero Echo Time (ZTE) scan for head attenuationPET/MR zero echo time (ZTE) scan for head attenuation and Q.Static . PET/MR ZTE MRAC images to be acquired for post-processing and reader assessment. Zero Echo Time (ZTE) scan for head attenuation |
| PET/MR Q Static (Q. MRAC) | Experimental | Device: Q.Static (Q. MRAC) for respiratory motion correctionQ.Static (Q. MRAC) for respiratory motion correction. PET/MR Q Static (Q. MRAC) images to be acquired for post-processing and reader assessment. PET/MR Q Static (Q. MRAC) |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (6 listed)
- Are adults (aged 18 or older);
- Have preexisting clinical indication for PET/CT or PET/MR with radiotracer injection (for subjects that will undergo ZTE procedures, a preexisting clinical indication for PET/CT is required);
- Are able to undergo PET/MR within the tracer validity time frame after radiotracer injection;
- Can hear without assistive devices and have necessary mental capacity to follow study instructions;
- Are willing and able to provide written informed consent;
Key exclusion criteria (5 listed)
- Were previously enrolled in the study;
- If female, are pregnant or of undetermined pregnancy status;
- Cannot fit safely in the device (>55 cm axial diameter or >227 kgs body weight);
- Have implants or attached medical devices that could be unsafe for MRI;
- Have medical conditions or require urgent care that could make it unsafe to participate
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Zero Echo Time (ZTE) scan for head attenuationThe GE SIGNA PET/MR MP26 software platform includes the zero echo time (ZTE) scan for head attenuation and Q.Static. The ZTE MR software feature has the potential to enable better visualization of bones, including those in the head, by employing optimal head attenuation correction in PET/MR. PET/MR ZTE MRAC | Device | PET/MR ZTE MRAC |
| Q.Static (Q. MRAC) for respiratory motion correctionAn improved Q.Static feature with Q. MRAC, where phase matching the MRAC with the quiescent phase is employed to get more accurate attenuation correction for our Q.Static PET images. PET/MR Q Static (Q. MRAC) | Device | PET/MR Q Static (Q. MRAC) |
Primary outcome
Diagnostic Image Quality
Time frame: through study completion, an average of 2 months
scored on a 5-pt Likert scale: 1. Unacceptable 2. Poor 3. Acceptable 4. Good 5. Excellent
3 secondary outcomes
Determination of Diagnostic Acceptability
Time frame: through study completion, an average of 2 months
Ease of Use Per Procedure Rated on a 5-pt Likert Scale Score
Time frame: through study completion, an average of 2 months
Number of Participants Reporting "Yes" On All Binary Performance Scale Questions
Time frame: through study completion, an average of 2 months
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Dec 2018.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: No
Related trials for Brain Imaging
Active, not recruitingPhase 4
Effects of Sequential Therapy With Mexidol® (Intravenous) and Mexidol® FORTE 250 (Oral) on Functional Brain Activity Assessed by Functional Magnetic Resonance Imaging and Biochemical Parameters in Patients With Chronic Cerebral Ischemia: A Comparison of Patients With and Without Metabolic Disorders
Metabolic Abnormalities, Obesity & Overweight
Not yet recruiting
Effects of Ad Libitum Ultra-Processed Diet on Brain Dopamine in Humans
Healthy Volunteers
RecruitingObservational study
PET Imaging in the Baltimore Longitudinal Study of Aging (BLSA)
Aging
RecruitingPhase 1
First-in-Human Evaluation of [11C]JMJ-129-d2 for PDE4D Imaging in Healthy Volunteers
Healthy
Not yet recruiting
Medico-Economic Evaluation of MRI Versus CT as Diagnostic Imaging Strategies in Patients With Suspected Ischemic Stroke: the MAGRITTE Study.
Stroke
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Tibor Duliskovich, M.D. study director
GE Healthcare, Medical Monitor
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Zero Echo Time (ZTE) scan for head attenuation and Q.Static (Q. MRAC) for respiratory motion correction in people with Brain Imaging and Whole Body Imaging, run by GE Healthcare at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 6 Dec 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 6 Dec 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Diagnostic Image Quality (time frame: through study completion, an average of 2 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Dec 2018.