AzTrials
AzTrials

Displacement of Other Bone Devices, Implants and GraftsNCT02891499

Influence of Low-level Laser Therapy on Stability and Displacement of Orthodontic Miniscrew Implants

A study testing Low-level laser therapy and Mediate force application in people with Displacement of Other Bone Devices, Implants and Grafts and Mechanical Complication of Other Bone Devices, Implants and Grafts, run by University of Sao Paulo.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to evaluate the effect of Low level laser therapy on stability and displacement of orthodontic miniscrew implants using two different force application protocols. Read more about this study

Who is it for?
Ages 11 years and olderHealthy volunteers can take part
What is being tested?
Low-level laser therapy and Mediate force application
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
29 participants
Where
No sites listed yet
Study dates
Mar 2016to Aug 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 11 years and older
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • Patient with permanent teeth.
  • Use of miniscrews in orthodontic planning.
  • Miniscrews placed in the labial upper and lower posterior regions.
  • Patient who agree to participate (Informed consent)

Who cannot join

  • Patient with systemic disease.
  • Patient with periodontal disease and/or inadequate oral hygiene.
  • Use of drugs chronically.
  • Patients that consume alcohol or tobacco.
  • Use of fixed palatal or lingual orthodontic devices.

About this study

Official title: Effect of Low-level Laser Therapy on Stability and Displacement of Orthodontic Miniscrew Implants With Mediate and Immediate Force Application

The purpose of this study is to evaluate the effect of Low level laser therapy on stability and displacement of orthodontic miniscrew implants using two different force application protocols.

Read the detailed description

The aim of this study is to evaluate the effect of Low level laser therapy (LLLT) on stability and displacement of orthodontic miniscrew implants with mediate and immediate force application. They will be assessed 48 miniscrew implants placed in patients in orthodontic treatment at the postgraduate clinical in Orthodontics, at School of Dentistry of Ribeirão Preto, University of São Paulo. They will be randomly divided into 4 groups: 1- LLLT and immediate force application; 2- LLLT and force application 4 weeks after implantation; 3- immediate force application without LLLT and 4- force application 4 weeks after implantation without LLLT. Orthodontic force of 150 gF will be applied for 3 months. A low power laser device Therapy XT with a wavelength of 660 nm and output of 100 mW immediately after implantation (energy density: 4J/cm2), and 808 nm with 100 mW (energy density: 8J/cm2), every 48 hours for two weeks in the following applications will be used. The stability will be assessed using Resonance Frequency Analysis (RFA) at three times: the implantation day (T1), one month (T2) and after 3 months of force application (T3). Stability measures will be evaluated in Implant Stability Quotient (ISQ). To assess the amount of miniscrew implant displacement, it will be used Cone Beam Computed Tomography (CBCT) at the beginning (CT1) and final of the application of orthodontic force (CT2). Three-dimensional models will be created in specific programs and superimpositions of CT1 and CT2 will be used to measure the distance in millimeters between inicial and final position. The evaluation will be carried out in three points: head of miniscrew implant (point C), thread (point R) and apex of miniscrew implant (point A). The results will be statistically analyzed according to nature of the data and the significance level to be adopted will be 5%.

Being tested
Low-level laser therapy, Mediate force application
Keywords
Miniscrews, Mini-implants, Temporal anchorage devices, Bone screws, Stability, Displacement, Low-level laser therapy, Cone-beam computed tomography, Resonance frequency analysis, Orthodontic, Orthodontic miniscrew implant

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Low-level laser therapyProcedure or surgery

    1. Immediate post-operative period (implantation day) Red emission (660 nm) Energy density: 4 J/cm2 Power: 0.1W Irradiation area: 0,5 cm2 One application, 10 seconds of non-contact irradiation (01 point at the area surrounding the miniscrew) at a distance of 15,5 mm.
    2. Mediate post-operative period (after implantation day) Infrared emission (808 nm) Energy density: 8 J/cm2 Power: 0.1W Irradiation area: 0,5 cm2 6 applications every 48 hours after the day of implantation, 20 seconds of non-contact irradiation (01 point on the area surrounding the miniscrew) at a distance of 15,5 mm.
  • Mediate force applicationProcedure or surgery

    Mediate force application protocol: orthodontic force application (150 gF) 4 weeks after the day of the implantation.

Study groups in NCT02891499
Study groupRoleWhat they receive
LLLT + immediate forceExperimentalUse of Low-level laser therapy and not mediate orthodontic force application (150 gF the day of the implantation).
Receives: Procedure: Low-level laser therapy
LLLT + mediate forceExperimentalUse of Low-level laser therapy and mediate orthodontic force application (150 gF 4 weeks after the day of the implantation).
Receives: Procedure: Low-level laser therapy; Procedure: Mediate force application
Immediate force applicationNo interventionNot mediate orthodontic force application (150 gF the day of the implantation), without use of Low-level laser therapy.
Mediate force applicationExperimentalMediate orthodontic force application (150 gF 4 weeks after the day of the implantation), without use of Low-level laser therapy.
Receives: Procedure: Mediate force application

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change from baseline miniscrew implant stability at 1 and 3 months of force application.

    It will be used a Resonance frequency analysis (RFA) equipment. Stability measures will be evaluated using a unique unit of measure: Implant stability quotient (ISQ). All groups will be evaluated the day of the implantation (T1) and after 1 month (T2).The last stability measure (T3) will be done 3 months after the implantation day in the groups without mediate force application, and 4 months after the implantation day in the groups with mediate force application.

    Measured: T1: Implantation day; T2: after 1 month; and, T3: after 3 months of force application.

  2. Change from baseline miniscrew implant position at 3 months of force application.

    It will be used Cone Beam Computed tomography (CBCT). Three-dimensional models will be created in specific programs and superimpositions of CT1 and CT2 will be used to measure the distance in millimeters between initial and final position.

    Measured: CT1: Implantation day; and, CT2: 3 months of orthodontic force application.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Sep 2016 (estimated)
  2. Study startMar 2016
  3. Primary completionFeb 2017
  4. Study completionAug 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
29 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02891499
Sponsor's protocol ID
USaoPaulo-1
Status last verified
Jan 2018
First submitted
23 Aug 2016
Last updated
18 Jan 2018
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Low-level laser therapy and Mediate force application in people with Displacement of Other Bone Devices, Implants and Grafts and Mechanical Complication of Other Bone Devices, Implants and Grafts, run by University of Sao Paulo.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 Jan 2018. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change from baseline miniscrew implant stability at 1 and 3 months of force application. (time frame: T1: Implantation day; T2: after 1 month; and, T3: after 3 months of force application.). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Jan 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in