AzTrials
AzTrials

Quality of LifeNCT02866617

Randomized Controlled Clinical Trial Of Oral Health-Related Quality Of Life In Patients Wearing Vacuum Formed Thermoplastic Retainers Constructed On Conventional Stone Models And On 3D Reconstructed Orthodontic Study Model

A study testing Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model in people with Quality of Life, run by University of Malaya at 1 site in Malaysia.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

In dentistry, 3D printing technology is gaining interest. One of the potential application is to construct appliances on 3D reconstructed study models. The purpose of this study is to compare vacuum formed thermoplastic orthodontic retainers (VFR) constructed on conventional orthodontic study models and reconstructed… Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
Conditions the study is for
Quality of Life
What is being tested?
Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteMalaysia
Study dates
Oct 2015to 30 Mar 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult
  1. Inclusion criteria
  2. fixed appliance treatment following both arches;
  3. indicated for vacuum formed thermoplastic retainers as retention phase in treatment plan;
  4. Exclusion criteria:
  5. single-arch or sectional fixed appliance treatment,
  6. hypodontia requiring tooth replacement on the retainer as a temporary measure,
  7. undergone rapid maxillary expansion,
  8. indicated for double retention regime (bonded retainers),
  9. early debonding patients.
  10. patients intending to relocate within the study period
  11. patient with learning difficulties and can't read written instructions/questionnaire in English or Malay
  12. patient with cleft lip or palate
  13. has undergone surgical treatment

Trial locations and contacts

1 site in 1 country.

Malaysia1 site
  • Faculty of Dentistry, University of Malaya

    Kuala Lumpur, 50603

Other trials in Malaysia

About this study

In dentistry, 3D printing technology is gaining interest. One of the potential application is to construct appliances on 3D reconstructed study models.

The purpose of this study is to compare vacuum formed thermoplastic orthodontic retainers (VFR) constructed on conventional orthodontic study models and reconstructed 3D study models by assessing the oral health-related quality of life (OHRQoL) instrument, Little's Irregularity Index (LII) and compliance.

Read the detailed description

Aim:

To compare the impact of 2 types of vacuum formed thermoplastic retainers on patients.

Objectives:

  1. To compare oral health-related quality of life in patients wearing vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.
  2. To compare compliance between vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.
  3. To compare stability in patients wearing vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.

Research Methadology

Ethical Consideration:

Application for ethical approval from Medical Ethics Committee, Faculty of Dentistry, University of Malaya.

Study population

This randomized controlled clinical trial will include existing patients who visited the Faculty of Dentistry, University of Malaya, for fixed orthodontic treatment and are due to have their fixed appliances removed.

5.2 Sample Size Estimation

Sample size estimation is based on previous study done by Jäderberg et al (2012) and calculated using PS Software (Power and Sample Size Calculation).

A sample size calculation was performed based on an alpha significance level of 0.05 and a beta of 0.1 to achieve 90 per cent power to detect a clinically meaningful difference of 1.0 mm [standard deviation (SD) 1.0] between the groups. The sample size calculation revealed that 22 pairs of sample were sufficient. This number of sample size will also achieve a moderate Pearson Product Moment correlation between the two groups. However, to compensate for possible dropouts, 30 pairs were enrolled in this clinical trials.

5.4 Materials and methods

  1. Enrollment \& Randomization Potential subjects will be recruited from the patients receiving orthodontic treatment at the Faculty of Dentistry, University of Malaya. Patients were screened based on when they were scheduled for debonding and the inclusion and exclusion criteria listed above. An online random number generator was used to create a randomization list of study numbers matched to either Group A or Group B. The day of debonding potential subjects were given consent and officially enrolled in the study.
  2. Study Groups As the flow chart below illustrates, two study groups existed for this randomized cross-over observational study. Each study group received 3 sets of vacuum formed thermoplastic retainers. Group A will wear vacuum formed thermoplastic retainers constructed by laboratory technician according to their standard protocol for 1 week from the day of debond, then vacuum formed thermoplastic retainers constructed on stone study model by one dentist after 1 week of debond for 3 months and later vacuum formed thermoplastic retainers constructed on 3D reconstructed study model for another 3 months. Group B will wear vacuum formed thermoplastic retainers constructed by laboratory technician according to their standard protocol for 1 week from the day of debond, then vacuum formed thermoplastic retainers constructed on 3D reconstructed study model by one dentist after 1 week of debond for 3 months and later vacuum formed thermoplastic retainers constructed on stone study model for another 3 months.
  3. Study Visit #1- Debonding Appointment All subjects were debonded by resident doctor, all residual composite removed, and teeth appropriately polished. Final photos were taken per University Clinic protocol. After debond, maxillary and mandibular alginate impressions (Hydrogum 5, Zhermack, Italy) will be obtained from each sample; two for working model and one for study model). One set of impression will be sent to University's Orthodontic Laboratory for construction of vacuum formed thermoplastic retainer by the laboratory technician for 1st appliance (to be issued on the same day of debond). The vacuum formed thermoplastic retainerss were made in the lab using thermoplastic material and clinic's Biostar machine available at the lab using the standard instructions provided by the manufacturer. vacuum formed thermoplastic retainerss were cooled and trimmed accordingly. Clinically vacuum formed thermoplastic retainerss were evaluated by resident doctor intra orally and were adjusted for patient comfort. All subjects were instructed to wear their retainers full time, only remove to eat, brush, and clean. For the remaining two sets of impression, the impression is poured in dental stone within 24hours.
  4. Acquisition of stone study model. Impressions obtained will be disinfect before casting. The white stone (Elite Ortho, Zhermack, Italy) is mixed and tapped into the impression a little at a time to ensure no air is trapped within the stone mix and some stone is used to form the base. Once the stone has set sufficiently, the impression is inverted on the base. When casting the lower impression, stone in the lingual section is removed before setting fully to ensure that the impression can easily be removed from the model.

Once the base has fully set the impression will be carefully removed from the stone and gradually lifted from the model using a plaster knife. The resulting stone model is then trimmed using a model trimmer. The base of the model parallel to the occlusal plane is trimmed to ensure even adaption of the thermoforming material. The back edge of the model should be trimmed so that it is at 90° to the sagittal plane. The labial and buccal sides of the model should be trimmed round so that the final model is a 'D' shape.

5 : Acquisition of digital model. Conventional study model will be scanned using structured light scanner (Maestro 3D, Age Solutions, Inc, Italy) via EasyDentalScan software (Age Solutions, Inc) to produce 3D digital model. The scanned data for both upper and lower conventional study models will be saved and exported as binary stereolithographic (.stl) files.

6 : Acquisition of reconstructed model. A Fused Deposition Modelling (FDM) machine (UP! 2 Plus 3D Printer) containing acrylonitrile butadiene styrene (ABS) plastic will be used to construct replica (RP) model from digital file according to manufacturing instructions. This process will be done by CBMTI SDN BHD ( a subsidiary of UM CAPITAL BERHAD), Institute of Postgraduate Studies, University of Malaya.

The prototyping process begins with unwinding the feedstock filament from a reel and feeding it through the liquefier located inside the system working envelop, as shown in figure below, where it gets gradually heated by temperature gradient provided by a number of coils wrapped helically about the axis of the liquefier .

The heated liquefier melts the plastic filament and deposits the melt through a nozzle attached at the exit controlling the diameter of final extrudate. Two step motors at the entrance of liquefier make sure a continuous supply of material during the model build-up. The nozzle and liquefier assembly is mounted onto a mechanical stage numerically controlled in X-Y plane. Upon receipt of precise tool paths prepared by the Insight software, the nozzle moves over the foam substrate depositing a thin bead of thermoplastic model material along with any necessary support structure. Deposition of fine extruded filaments onto the substrate produces a layer corresponding to a slice of the CAD model of the object. Once a layer is built the substrate moves down in z direction in order to prepare the stage for the deposition of next layer. The deposited filaments cool down immediately below the glass transition temperature of the polymer and get hardened. The entire build system is contained within a temperature- controlled environment with temperatures just below the glass-transition temperature of the polymer to provide an efficient intra-layer bonding.

7 : Acquisition of vacuum formed thermoplastic retainer

Each VFR was constructed from an Erkodur blank (Erkodent, Erich Kopp, GmbH, Pfalzgrafenweiler, Germany) 1.5 mm in thickness using the standard instructions provided by the laboratory's Biostar machine.

Retainer Designs:

vacuum formed thermoplastic retainerss Designs- Extraction and Non-extraction Cases

  • Upper- Trimmed for 1-2mm of facial gingival coverage, palatal coverage, and 2nd Molar occlusal coverage
  • Lower- Trimmed for 1-2mm of facial and lingual gingival coverage, 2nd Molar occlusal coverage. 8 : T2 and T3 visit: Issuing the vacuum formed thermoplastic retainer. The 2nd retainers will be fitted within 1 week after debond (T1) and the 3rd retainers is fitted 3 months (T2) after debond. The duration of retainer wear was standardized based on the standard protocol for retainer wear in the practice. The patients were instructed to wear the vacuum formed thermoplastic retainers 24 hours a day for the first week and remove them only for eating and brushing their teeth. After the first week, wear time was reduced to 10 hours a day (Thickett and Power, 2009). All patients will be provided with standardized oral and written instructions on how to use the retainers by one dentist.

The subjects were reviewed by a member of the research team at 2 intervals, 3 months (T2) and 6 months (T3) after debond. At the 3 month (T2) review appointment, the subjects will be given the Questionnaire Q2 to be filled up. Later, the 3rd retainer will be given to the subjects and again to be reviewed after 3 months (T3) of 3rd retainer issued ( 6 months after debond) and questionnaire Q3 will be administered.

Conditions
Quality of Life
Being tested
Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model
Keywords
Quality of Life, Vacuum formed thermoplastic retainer, Orthodontic study model, 3D reconstructed study model

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study ModelDevice

Study groups in NCT02866617
Study groupRoleWhat they receive
ConventionalExperimentalT1-T2 : VFR constructed on conventional study model T2-T3 : VFR constructed on 3D reconstructed study model
Receives: Device: Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model
3DExperimentalT1-T2 : VFR constructed on 3D reconstructed study model T2-T3 :VFR constructed on conventional study model
Receives: Device: Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Oral Health-Related Quality Of Life

    Measured: 6 month

Secondary outcomes (1)
  1. Little's Irregularity Index

    Measured: 6 month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Aug 2016 (estimated)
  2. Study startOct 2015
  3. Primary completion30 Jan 2017
  4. Study completion30 Mar 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Crossover
Masking
Double blind
Who is masked
Participant, Investigator
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02866617
Sponsor's protocol ID
PPPC/C1-2015/DGD/12
Status last verified
Apr 2018
First submitted
8 May 2016
Last updated
9 Apr 2018
Results posted
No

Publications

  • Mohd Tahir N, Wan Hassan WN, Saub R. Comparing retainers constructed on conventional stone models and on 3D printed models: a randomized crossover clinical study. Eur J Orthod. 2019 Aug 8;41(4):370-380. doi: 10.1093/ejo/cjy063.

    PubMed 30321319

Questions about this trial

What is this clinical trial studying?

A study testing Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model in people with Quality of Life, run by University of Malaya at 1 site in Malaysia.

The full registered description is in the About this study section and the official record.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 9 Apr 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Malaysia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Oral Health-Related Quality Of Life (time frame: 6 month). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02866617, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Apr 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in