Trial summary

X-ray beam produced during endoscopic retrograde cholangiopancreatography (ERCP) affect not only the patient, but the personnel of ERCP team may have the effect from the scattered ray. According to the automatic beam adjustment function, the thicker object (eg. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Occupational Radiation Exposure
What is being tested?
Automatic beam adjustment function
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
55 participants
Where
No sites listed yet
Study dates
Jul 2016to Nov 2016
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Indicated for ERCP

Who cannot join

  • pregnancy
  • American Society of Anesthesiologists (ASA) physical status class III - IV
  • unstable vital signs
  • patients' position needed to be changed during the procedure
  • patients who need fixed position for ERCP (such as biliary hilar lesion)
  • enteroscope-assisted ERCP
  • the consent form can not be obtained

About this study

Official title: Radiation Exposure of ERCP Personnel at Different Standing Locations and Different Patient Positions (Prone and Left Lateral Decubitus)

X-ray beam produced during endoscopic retrograde cholangiopancreatography (ERCP) affect not only the patient, but the personnel of ERCP team may have the effect from the scattered ray. According to the automatic beam adjustment function, the thicker object (eg. lying left lateral) might produce higher scatter ray than thinner object (eg. lying prone). The investigators evaluate the radiation exposure among ERCP personnel compare between patient's 2 different positions.

Read the detailed description

Personal solid-state dosimeters were used to measure the radiation dose on personnel during ERCP procedure. The real-time effective doses were displayed at a monitoring screen. A dosimeter was attached outside thyroid collar of each ERCP team member included of 1st endoscopist, 2nd endoscopist, and nurse anesthetist.

Patients' age, gender, BMI, body thickness, and indications for ERCP were recorded. The patients were randomized into 2 groups by block-of-four. The patients' position was assigned to prone or left lateral decubitus. Each ERCP personnel wore a lead apron and the dosimeter was attached outside the thyroid collar. The ERCP procedure was performed according to the indication in a standard technique. After ERCP procedure, the total fluoroscopic time (minute), fluoroscopy tube voltage (kV), fluoroscopy tube current (mA), patient entrance skin dose (mGy) and personnel effective dose (Sv) from each dosimeter were recorded.

Continuous variables were compared by Student's t-test or Man Whitney U-test, where appropriate. Categorical variables were compared by Chi-square or the Fisher exact test. Statistical analysis was calculated by using SPSS statistical software (version17 for Window, Chicago, USA) and two sided p-value < 0.05 was considered to be statistical significant.

Being tested
Automatic beam adjustment function
Keywords
radiation exposure, ERCP, prone, left lateral decubitus

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Automatic beam adjustment functionRadiation

    The fluoroscopy system has an automatic beam adjustment function to maintain a good quality of image output.

Study groups in NCT02791659
Study groupRoleWhat they receive
Left lateral decubitusActive comparatorIn this group, the position will be assigned to Left lateral decubitus during ERCP. The radiation from fluoroscopy will be adjusted by automatic beam adjustment function to obtain the image quality.
Receives: Radiation: Automatic beam adjustment function
ProneExperimentalIn this group, the position will be assigned to Prone during ERCP. The radiation from fluoroscopy will be adjusted by automatic beam adjustment function to obtain the image quality.
Receives: Radiation: Automatic beam adjustment function

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Effective Radiation Dose

    The effective radiation which represents equivalent dose to eye lens of each personnel were compared between 2 groups.

    Measured: Immediate after procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Jun 2016 (estimated)
  2. Study startJul 2016
  3. Primary completionOct 2016
  4. Study completionNov 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
55 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02791659
Sponsor's protocol ID
PA-E-RAD002
Status last verified
Apr 2017
First submitted
1 Jun 2016
Last updated
30 May 2017
Data monitoring committee
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Automatic beam adjustment function in people with Occupational Radiation Exposure, run by Chulalongkorn University.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 30 May 2017. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 22 Mar 2017). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Effective Radiation Dose (time frame: Immediate after procedure). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 May 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in