Mechanical VentilationNCT02791425
Brain Computer Interface for Communication in Ventilated Patients
A study testing Brain Computer Interface (BCI) device and Communication picture board in people with Mechanical Ventilation and Nonverbal Communication, run by University of Michigan at 1 site in United States.
Trial summary
Objectives: Specific Aim 1: To demonstrate the feasibility of using a Steady State Visual Evoked Potential (SSVEP) based Brain Computer Interface (BCI) device to facilitate communication of common patient needs in alert mechanically ventilated patients in the Intensive Care Unit (ICU). Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Mechanical Ventilation, Nonverbal Communication, Intratracheal Intubation
- What is being tested?
- Brain Computer Interface (BCI) device and Communication picture board
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 1 participants
- Where
- 1 siteUnited States
- Study dates
- 1 Mar 2017to 25 Aug 2017
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Admitted to an Intensive Care Unit and on mechanical ventilation for at least 24 hours
- Age 18 years or older
- Able to briskly follow commands
- Unimpaired use of at least one upper limb
Who cannot join
- Ongoing respiratory distress, severe pain or other source of obvious discomfort requiring immediate medical or nursing attention
- Severe hemodynamic instability with ongoing need for vasopressor titration or resuscitation
- Known impairment of vision, other than error of refraction with corrective lenses present
- Inability to tolerate interruption of sedation
- Inability to communicate fluently in English
- Need for ongoing EEG monitoring
Trial locations and contacts
1 site in 1 country.
United States1 site
University of Michigan Health System
Ann Arbor, Michigan, 48109
About this study
Official title: Wearable Brain Computer Interface (BCI) to Assist Communication in Mechanically Ventilated Patients the Intensive Care Unit (ICU)
Objectives:
Specific Aim 1: To demonstrate the feasibility of using a Steady State Visual Evoked Potential (SSVEP) based Brain Computer Interface (BCI) device to facilitate communication of common patient needs in alert mechanically ventilated patients in the Intensive Care Unit (ICU).
Read more
Specific Aim 2: To determine patient, family and bedside nurse satisfaction with communication using the BCI device and elicit open-ended feedback to guide future device improvements
Design:
Translational pilot study of a Steady State Visual Evoked Potential (SSVEP) based BCI system to facilitate communication in intubated patients, with sequential use of the BCI device and a picture board.
Selection of the primary self-identified primary patient need on the BCI device will be compared to the icon selected on the picture board (reference standard). A patient satisfaction survey will then be provided to the patient or a family member following use for 2 hours a day for 3 consecutive days.
Primary outcome: Accurate selection of the illustrative icon on the brain computer interface representing the physical or emotional need self-identified by the patient as being the most common trigger for communication with the bedside nurse during their admission.
Secondary outcome: Selection by patients or family of "agree" or "strongly agree" with the statement "The Brain computer interface device allowed me to communicate my needs to the bedside nurse adequately".
Intervention: Use of the brain computer device in the ICU for communication for 2 hours a day for 3 consecutive days
Control/ Comparator: Sequential use of a communication picture board for 2 hours a day for 3 consecutive days, on the same days that the BCI device is used Sample Size: 30 mechanically ventilated but alert patients in the Intensive Care Unit
Read the detailed description
BACKGROUND
An inability to consistently and effectively communicate their most fundamental physical needs is a major problem for mechanically ventilated ICU patients. Patients rate about 40% of communication sessions as difficult and more than a third of communications about pain as unsuccessful. Nurses initiate about 86% of all communication exchanges as it is typically very difficult for a voiceless ICU patient to initiate communication. Patients in the ICU therefore commonly suffer unrecognized pain and discomfort, feelings of loss of control and insecurity, depersonalization, anxiety, sleep disturbances, fear and frustration. Caregivers also frequently report feeling anxious and frustrated in not being able to adequately assess the needs of their patients. This inability to communicate effectively can lead to the inappropriate use of sedatives and prolongation of time spent on the ventilator, which may then lead to increased ICU length of stay and costs. Furthermore, the inability to communicate with caregivers hampers the ability of critically ill patients to be active participants in their treatment and in decision-making, including decisions to withdraw or withhold life-sustaining treatment.
The use of picture boards with icons representing common patient needs and complaints (pain, fear, hot/ cold, thirst, bedpan etc) has been shown to improve nurse-patient communication for patients in the postoperative period on the ventilator. These picture boards are widely available in most ICUs and are the closest thing to a current standard for communication with voiceless mechanically ventilated patient, for the purposes of addressing fundamental physical and emotional needs. Recent pilot studies have described the use of computer-assisted communication using touch sensitive screens, eye blink detectors and gaze trackers to enable communication in the ICU patient. The majority of patients and hospital staff surveyed in these studies indicated that the use of a computer-assisted communication device improved the ability to respond to patient needs and address patient comfort. Gaze and eye blink tracker systems are expensive, however, while touch sensitive screens may not be suitable for the many ICU patients with weakness and restriction in motor ability. Patients in the ICU, particularly those with neurological illness, frequently suffer from significant weakness and loss of co-ordination, however, limiting their ability to use their arms and hands to indicate the appropriate item on the board. While patients in the neuroICU are frequently weak because of focal brain injury, about a quarter of patients requiring mechanical ventilation in other ICUs may have significant weakness from critical illness neuropathy and myopathy, limiting their ability to use their hands to select the appropriate icon on a picture board. There are several patient populations, however, for whom the use of a picture board or touch screen is impossible, including patients with high spinal cord injury, advanced ALS and brainstem stroke, who are voiceless, but also typically have no useful motor function of their limbs. These patients are "locked-in", to varying degrees, awake and alert but with no control of bodily function or ability to articulate and communicate using standard forms of communication.
The use of Brain Computer Interface (BCI) devices to facilitate communication in "voiceless" patients has recently generated interest. A BCI translates deliberate, voluntary modulation of cerebral electrical activity, typically recorded by electroencephalography (EEG) into computer commands. A variety of BCI devices have been used to permit patients with advanced Amyotrophic Lateral Sclerosis (ALS), high spinal cord injury and brainstem stroke with the locked-in-syndrome, who have no voluntary use of their limbs, to communicate to varying degrees. These devices have typically been evaluated in the rehabilitation setting, following the period of acute medical illness, or at home. No study has evaluated the use of a BCI device to assist with communication of the typical physical and emotional needs/ complaints of the critically ill. This is significant, not only for patients with spinal cord injury and stroke, most of who are initially admitted to an ICU, but to the potentially large number of ICU patients who cannot use a picture board or other finger contact system because of critical illness neuropathy/ myopathy or acute brain injury causing weakness. Our focus is on creating a steady state visual evoked potential (SSVEP) based, wireless BCI system to facilitate communication with intubated ICU patients., The wearable BCI device of interest in this study functions through visual attention to illustrative icons displayed on an electronic screen. The icon, which may depict a common ICU patient need, such the need for repositioning or common patient complaint, such as pain, can be displayed as a symbol. The patient can, thereby, communicate by looking at a specific item depicting their need or complaint. This wearable device is entirely noninvasive and without significant risk to patients, functioning only to record and translate EEG signals. The device will communicate wirelessly with the user interface (UI) that can be either a tablet or the flat screen TV monitor that is present in every ICU patient room. The proposed prototype provides a user interface that includes basic functions that are typically used in communication between nurses and patients in the ICU.
STUDY DESIGN
This is a translational pilot study of a Steady State Visual Evoked Potential (SSVEP) based BCI system to facilitate communication in intubated patients. After obtaining informed consent from the patient or their legally authorized representative, 30 patients will be recruited from the medical, surgical, cardiac, cardiothoracic and neurological intensive care units at the University of Michigan, Ann Arbor over a period of 12 months. Approval has been obtained from the Institutional Review Board of the University of Michigan (HUM00095052).
Screening for delirium and ability to participate in the study:
Potential subjects will be identified by members of the primary ICU team, who will then contact a study investigator. Subjects will need to be off all sedating medicines with return to full wakefulness prior to further evaluation. Patients meeting the above eligibility criteria who consent to participate in the study will then undergo further testing by an investigator to confirm that the patient is sufficiently alert and attentive to communicate AND is capable of consistently selecting items through volitional finger contact. The patient will then undergo a screening evaluation with the BCI device to confirm that their individual EEG signal can be detected and interpreted by the device.
Patient complaints/ needs: The investigators will evaluate the ability of subjects to accurately select a specific need or complaint from 10 common needs/ complaints.
- "I am in pain"
- "I have difficulty breathing"
- "I need to be suctioned"
- "I need to have a bowel movement"
- "I need to pee/ pass urine"
- "I am thirsty"
- "I am hungry"
- "I need to have my position in bed changed"
- "Raise the head of my bed"
- "I need my family at my bedside"
Picture board: Feasibility of communication using the BCI device will be evaluated using a picture board with illustrative icons representing the 10 needs/ complaints above as the standard for comparison and to determine the accuracy of selection of the appropriate icon. The icons and phrases on the picture board will be identical to the icons and phrases on the BCI device
SPECIFIC AIM 1:
To demonstrate the feasibility of using a Steady State Visual Evoked Potential (SSVEP) based Brain Computer Interface (BCI) device to facilitate communication of common patient needs in alert mechanically ventilated patients in the Intensive Care Unit (ICU).
Hypothesis 1: At least 80% of alert mechanically ventilated patients will be able to accurately select the illustrative icon on the brain computer interface representing the physical or emotional need self-identified by the patient as being the most common trigger for communication with the bedside nurse during their admission.
Orientation to BCI and picture board: The patient will initially be familiarized with both the picture board and the BCI device. Instruction on use of the BCI device will include demonstration of the UI, explanation of the icons on the UI and the mechanism of selection of an icon, through focused visual attention.
Selection of need/ complaint: Immediately following orientation, testing for accuracy of the BCI device will be performed. Testing for accuracy will be performed a single time for each patient, using the most important need/ complaint for that patient. The patient will be asked to identify on the BCI UI the specific need or complaint as being the most common reason to request the assistance of the bedside nurse during their admission, among the 10 patient need/ complaint options provided. Selection of "None of the above/ Other" will be permitted, however, the patient will be specifically instructed in advance to select the need/ complaint most applicable to their situation among the 10 choices provided. The patient will then be asked to select the SAME need/ complaint on the picture board using finger contact.
SPECIFIC AIM 2:
Specific Aim 2: To determine patient, family and bedside nurse satisfaction with communication using the BCI device and elicit open-ended feedback to guide future device improvements.
Hypothesis 2: At least 70% of patients will "agree" or "strongly agree" with the statement "The Brain computer interface device allowed me to communicate my needs to the bedside nurse adequately".
Immediately following evaluation of accuracy described under Specific Aim 1, the investigators will evaluate patient, family and bedside nurse satisfaction following bedside use of the device as the primary communication tool for 2 hours a day for 3 consecutive days. A delirium screen using CAM-ICU and a brief neurological examination to confirm the patient's ability to effectively use the BCI device and picture board will be performed prior to use of the device or picture board on subsequent days (days 2 and 3).
At the end of the 3 days, the patient, any family members present and each nurse who participated in testing will be provided the short questionnaires. The patient questionnaire with options will be read out to the patient.
Statistical Analysis:
The proportion of patients who pass Step 2 of screening who then also pass Step 3 will be calculated with exact binomial 95% confidence intervals. A proportion of at least 70% passing Step 3 of screening will be the initial threshold for feasibility, based on clinical estimates of value. The median time, with interquartile range, required for orientation to the BCI device and to the picture board will be calculated, and comparison performed using the Mann Whitney U-test. The proportion of patients who select the same icon on the BCI UI and the picture board will be calculated, with exact binomial 95% confidence intervals. In determining the accuracy of using the BCI device, a binomial analysis including multiple studies of BCI estimated the chance level at 63% (α = 0.05, 60 trials). Based also on a clinical estimate of what would be a minimum useful level of accuracy for a communication device, the threshold for accuracy in our study will be at least 80% of patients demonstrating concordance between selection of their most important need/ complaint on the BCI device and the picture board. Descriptive statistics will be used to for proportions of patients selecting responses to each of the satisfaction questions.
- Conditions
- Mechanical Ventilation, Nonverbal Communication, Intratracheal Intubation, Critical Illness
- Being tested
- Brain Computer Interface (BCI) device, Communication picture board
- Keywords
- Brain-Computer Interface, Intratracheal intubation, Mechanical ventilation, Nonverbal communication, Critical illness, Electroencephalography, Visual Evoked Potential
- Medical subject headings
- Nonverbal Communication, Critical Illness
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Brain Computer Interface (BCI) deviceDevice
A BCI system to facilitate communication in intubated patients. Patients use the device in the ICU for communication for 2 hours a day for 3 consecutive days.
Communication picture boardOther
The patient then uses a communication picture board for 2 hours a day for 3 consecutive days on the same days that the BCI device is used for comparison.
| Study group | Role | What they receive |
|---|---|---|
| Brain Computer Interface (BCI) device | Experimental | The patient uses the Brain Computer Interface (BCI) device in the ICU for communication for 2 hours a day for 3 consecutive days. The patient then uses a communication picture board for 2 hours a day for 3 consecutive days on the same days that the BCI device is used for comparison. Receives: Device: Brain Computer Interface (BCI) device; Other: Communication picture board |
What is being measured
The primary outcome is the main question the study is designed to answer.
BCI device accuracy
Accurate selection of the illustrative icon on the brain computer interface representing the physical or emotional need self-identified by the patient as being the most common trigger for communication with the bedside nurse during their admission.
Measured: Immediately following enrollment
Secondary outcomes (1)
Satisfaction survey
Selection by patients or family of "agree" or "strongly agree" with the statement "The Brain computer interface device allowed me to communicate my needs to the bedside nurse adequately".
Measured: At the end of 3 days of using BCI device
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted6 Jun 2016 (estimated)
- Study start1 Mar 2017
- Primary completion25 Aug 2017
- Study completion25 Aug 2017
Why it stopped: The developer of the BCI left the institution so the study could not continue
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (19)Papers the sponsor has linked to this study.
- Other trials for Mechanical VentilationStudies of the same condition, open and under way.
- More trials run by University of MichiganThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 1 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Michigan
- Sponsor type
- University, hospital or other
- Collaborators
- Michigan Institute for Clinical and Health Research (MICHR)
- Responsible party
- Principal investigator, Venkatakrishna Rajajee, University of Michigan
- Investigators
- Omid Dehzanghi, PhD, Principal investigator, University of Michigan
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02791425
- Sponsor's protocol ID
- HUM00100788
- Status last verified
- Apr 2019
- First submitted
- 1 Jun 2016
- Last updated
- 17 Apr 2019
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Happ MB, Garrett K, Thomas DD, Tate J, George E, Houze M, Radtke J, Sereika S. Nurse-patient communication interactions in the intensive care unit. Am J Crit Care. 2011 Mar;20(2):e28-40. doi: 10.4037/ajcc2011433.
PubMed 21362711Johnson MM, Sexton DL. Distress during mechanical ventilation: patients' perceptions. Crit Care Nurse. 1990 Jul-Aug;10(7):48-57. No abstract available.
PubMed 2403412Carroll SM. Nonvocal ventilated patients perceptions of being understood. West J Nurs Res. 2004 Feb;26(1):85-103; discussion 104-12. doi: 10.1177/0193945903259462.
PubMed 14984652Baker C, Melby V. An investigation into the attitudes and practices of intensive care nurses towards verbal communication with unconscious patients. J Clin Nurs. 1996 May;5(3):185-92. doi: 10.1111/j.1365-2702.1996.tb00248.x.
PubMed 8705084Thomason JW, Shintani A, Peterson JF, Pun BT, Jackson JC, Ely EW. Intensive care unit delirium is an independent predictor of longer hospital stay: a prospective analysis of 261 non-ventilated patients. Crit Care. 2005 Aug;9(4):R375-81. doi: 10.1186/cc3729. Epub 2005 Jun 1.
PubMed 16137350Miglietta MA, Bochicchio G, Scalea TM. Computer-assisted communication for critically ill patients: a pilot study. J Trauma. 2004 Sep;57(3):488-93. doi: 10.1097/01.ta.0000141025.67192.d9.
PubMed 15454792Maringelli F, Brienza N, Scorrano F, Grasso F, Gregoretti C. Gaze-controlled, computer-assisted communication in Intensive Care Unit: "speaking through the eyes". Minerva Anestesiol. 2013 Feb;79(2):165-75. Epub 2012 Nov 22.
PubMed 23174919Smith E, Delargy M. Locked-in syndrome. BMJ. 2005 Feb 19;330(7488):406-9. doi: 10.1136/bmj.330.7488.406. No abstract available.
PubMed 15718541Daly JJ, Huggins JE. Brain-computer interface: current and emerging rehabilitation applications. Arch Phys Med Rehabil. 2015 Mar;96(3 Suppl):S1-7. doi: 10.1016/j.apmr.2015.01.007.
PubMed 25721542Chaudhary U, Birbaumer N, Curado MR. Brain-machine interface (BMI) in paralysis. Ann Phys Rehabil Med. 2015 Feb;58(1):9-13. doi: 10.1016/j.rehab.2014.11.002. Epub 2015 Jan 8.
PubMed 25623294Nijboer F, Sellers EW, Mellinger J, Jordan MA, Matuz T, Furdea A, Halder S, Mochty U, Krusienski DJ, Vaughan TM, Wolpaw JR, Birbaumer N, Kubler A. A P300-based brain-computer interface for people with amyotrophic lateral sclerosis. Clin Neurophysiol. 2008 Aug;119(8):1909-1916. doi: 10.1016/j.clinph.2008.03.034. Epub 2008 Jun 20.
PubMed 18571984Sellers EW, Ryan DB, Hauser CK. Noninvasive brain-computer interface enables communication after brainstem stroke. Sci Transl Med. 2014 Oct 8;6(257):257re7. doi: 10.1126/scitranslmed.3007801.
PubMed 25298323Marchetti M, Priftis K. Brain-computer interfaces in amyotrophic lateral sclerosis: A metanalysis. Clin Neurophysiol. 2015 Jun;126(6):1255-1263. doi: 10.1016/j.clinph.2014.09.017. Epub 2014 Oct 2.
PubMed 25449558Lesenfants D, Habbal D, Lugo Z, Lebeau M, Horki P, Amico E, Pokorny C, Gomez F, Soddu A, Muller-Putz G, Laureys S, Noirhomme Q. An independent SSVEP-based brain-computer interface in locked-in syndrome. J Neural Eng. 2014 Jun;11(3):035002. doi: 10.1088/1741-2560/11/3/035002. Epub 2014 May 19.
PubMed 24838215Muller-Putz GR, Scherer R, Brauneis C, Pfurtscheller G. Steady-state visual evoked potential (SSVEP)-based communication: impact of harmonic frequency components. J Neural Eng. 2005 Dec;2(4):123-30. doi: 10.1088/1741-2560/2/4/008. Epub 2005 Oct 25.
PubMed 16317236
Study at a glance
From the registry record, last updated by the sponsor on 17 Apr 2019. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Wearable Brain Computer Interface (BCI) to Assist Communication in Mechanically Ventilated Patients the Intensive Care Unit (ICU)
- ClinicalTrials.gov ID
- NCT02791425
- Acronym / sponsor ID
- HUM00100788
- Conditions
- Mechanical Ventilation, Nonverbal Communication, Intratracheal Intubation, Critical Illness
- Keywords
- Brain-Computer Interface, Intratracheal intubation, Mechanical ventilation, Nonverbal communication, Critical illness, Electroencephalography, Visual Evoked Potential
- Study type
- Interventional
- Recruitment status
- TerminatedReason stopped: The developer of the BCI left the institution so the study could not continue
- Enrolment
- 1 participants (actual)
- Lead sponsor
- University of MichiganUniversity, hospital or other
- Collaborators
- Michigan Institute for Clinical and Health Research (MICHR)
- Study start
- 1 Mar 2017 (actual)
- Primary completion
- 25 Aug 2017 (actual)
- Study completion
- 25 Aug 2017 (actual)
- First posted
- 6 Jun 2016 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Objectives:
Specific Aim 1: To demonstrate the feasibility of using a Steady State Visual Evoked Potential (SSVEP) based Brain Computer Interface (BCI) device to facilitate communication of common patient needs in alert mechanically ventilated patients in the Intensive Care Unit (ICU).
Specific Aim 2: To determine patient, family and bedside nurse satisfaction with communication using the BCI device and elicit open-ended feedback to guide future device improvements
Design:
Translational pilot study of a Steady State Visual Evoked Potential (SSVEP) based BCI system to facilitate communication in intubated patients, with sequential use of the BCI device and a picture board.
Selection of the primary self-identified primary patient need on the BCI device will be compared to the icon selected on the picture board (reference standard). A patient satisfaction survey will then be provided to the patient or a family member following use for 2 hours a day for 3 consecutive days.
Primary outcome: Accurate selection of the illustrative icon on the brain computer interface representing the physical or emotional need self-identified by the patient as being the most common trigger for communication with the bedside nurse during their admission.
Secondary outcome: Selection by patients or family of "agree" or "strongly agree" with the statement "The Brain computer interface device allowed me to communicate my needs to the bedside nurse adequately".
Intervention: Use of the brain computer device in the ICU for communication for 2 hours a day for 3 consecutive days
Control/ Comparator: Sequential use of a communication picture board for 2 hours a day for 3 consecutive days, on the same days that the BCI device is used Sample Size: 30 mechanically ventilated but alert patients in the Intensive Care Unit
Detailed description
BACKGROUND
An inability to consistently and effectively communicate their most fundamental physical needs is a major problem for mechanically ventilated ICU patients. Patients rate about 40% of communication sessions as difficult and more than a third of communications about pain as unsuccessful. Nurses initiate about 86% of all communication exchanges as it is typically very difficult for a voiceless ICU patient to initiate communication. Patients in the ICU therefore commonly suffer unrecognized pain and discomfort, feelings of loss of control and insecurity, depersonalization, anxiety, sleep disturbances, fear and frustration. Caregivers also frequently report feeling anxious and frustrated in not being able to adequately assess the needs of their patients. This inability to communicate effectively can lead to the inappropriate use of sedatives and prolongation of time spent on the ventilator, which may then lead to increased ICU length of stay and costs. Furthermore, the inability to communicate with caregivers hampers the ability of critically ill patients to be active participants in their treatment and in decision-making, including decisions to withdraw or withhold life-sustaining treatment.
The use of picture boards with icons representing common patient needs and complaints (pain, fear, hot/ cold, thirst, bedpan etc) has been shown to improve nurse-patient communication for patients in the postoperative period on the ventilator. These picture boards are widely available in most ICUs and are the closest thing to a current standard for communication with voiceless mechanically ventilated patient, for the purposes of addressing fundamental physical and emotional needs. Recent pilot studies have described the use of computer-assisted communication using touch sensitive screens, eye blink detectors and gaze trackers to enable communication in the ICU patient. The majority of patients and hospital staff surveyed in these studies indicated that the use of a computer-assisted communication device improved the ability to respond to patient needs and address patient comfort. Gaze and eye blink tracker systems are expensive, however, while touch sensitive screens may not be suitable for the many ICU patients with weakness and restriction in motor ability. Patients in the ICU, particularly those with neurological illness, frequently suffer from significant weakness and loss of co-ordination, however, limiting their ability to use their arms and hands to indicate the appropriate item on the board. While patients in the neuroICU are frequently weak because of focal brain injury, about a quarter of patients requiring mechanical ventilation in other ICUs may have significant weakness from critical illness neuropathy and myopathy, limiting their ability to use their hands to select the appropriate icon on a picture board. There are several patient populations, however, for whom the use of a picture board or touch screen is impossible, including patients with high spinal cord injury, advanced ALS and brainstem stroke, who are voiceless, but also typically have no useful motor function of their limbs. These patients are "locked-in", to varying degrees, awake and alert but with no control of bodily function or ability to articulate and communicate using standard forms of communication.
The use of Brain Computer Interface (BCI) devices to facilitate communication in "voiceless" patients has recently generated interest. A BCI translates deliberate, voluntary modulation of cerebral electrical activity, typically recorded by electroencephalography (EEG) into computer commands. A variety of BCI devices have been used to permit patients with advanced Amyotrophic Lateral Sclerosis (ALS), high spinal cord injury and brainstem stroke with the locked-in-syndrome, who have no voluntary use of their limbs, to communicate to varying degrees. These devices have typically been evaluated in the rehabilitation setting, following the period of acute medical illness, or at home. No study has evaluated the use of a BCI device to assist with communication of the typical physical and emotional needs/ complaints of the critically ill. This is significant, not only for patients with spinal cord injury and stroke, most of who are initially admitted to an ICU, but to the potentially large number of ICU patients who cannot use a picture board or other finger contact system because of critical illness neuropathy/ myopathy or acute brain injury causing weakness. Our focus is on creating a steady state visual evoked potential (SSVEP) based, wireless BCI system to facilitate communication with intubated ICU patients., The wearable BCI device of interest in this study functions through visual attention to illustrative icons displayed on an electronic screen. The icon, which may depict a common ICU patient need, such the need for repositioning or common patient complaint, such as pain, can be displayed as a symbol. The patient can, thereby, communicate by looking at a specific item depicting their need or complaint. This wearable device is entirely noninvasive and without significant risk to patients, functioning only to record and translate EEG signals. The device will communicate wirelessly with the user interface (UI) that can be either a tablet or the flat screen TV monitor that is present in every ICU patient room. The proposed prototype provides a user interface that includes basic functions that are typically used in communication between nurses and patients in the ICU.
STUDY DESIGN
This is a translational pilot study of a Steady State Visual Evoked Potential (SSVEP) based BCI system to facilitate communication in intubated patients. After obtaining informed consent from the patient or their legally authorized representative, 30 patients will be recruited from the medical, surgical, cardiac, cardiothoracic and neurological intensive care units at the University of Michigan, Ann Arbor over a period of 12 months. Approval has been obtained from the Institutional Review Board of the University of Michigan (HUM00095052).
Screening for delirium and ability to participate in the study:
Potential subjects will be identified by members of the primary ICU team, who will then contact a study investigator. Subjects will need to be off all sedating medicines with return to full wakefulness prior to further evaluation. Patients meeting the above eligibility criteria who consent to participate in the study will then undergo further testing by an investigator to confirm that the patient is sufficiently alert and attentive to communicate AND is capable of consistently selecting items through volitional finger contact. The patient will then undergo a screening evaluation with the BCI device to confirm that their individual EEG signal can be detected and interpreted by the device.
Patient complaints/ needs: The investigators will evaluate the ability of subjects to accurately select a specific need or complaint from 10 common needs/ complaints.
- "I am in pain"
- "I have difficulty breathing"
- "I need to be suctioned"
- "I need to have a bowel movement"
- "I need to pee/ pass urine"
- "I am thirsty"
- "I am hungry"
- "I need to have my position in bed changed"
- "Raise the head of my bed"
- "I need my family at my bedside"
Picture board: Feasibility of communication using the BCI device will be evaluated using a picture board with illustrative icons representing the 10 needs/ complaints above as the standard for comparison and to determine the accuracy of selection of the appropriate icon. The icons and phrases on the picture board will be identical to the icons and phrases on the BCI device
SPECIFIC AIM 1:
To demonstrate the feasibility of using a Steady State Visual Evoked Potential (SSVEP) based Brain Computer Interface (BCI) device to facilitate communication of common patient needs in alert mechanically ventilated patients in the Intensive Care Unit (ICU).
Hypothesis 1: At least 80% of alert mechanically ventilated patients will be able to accurately select the illustrative icon on the brain computer interface representing the physical or emotional need self-identified by the patient as being the most common trigger for communication with the bedside nurse during their admission.
Orientation to BCI and picture board: The patient will initially be familiarized with both the picture board and the BCI device. Instruction on use of the BCI device will include demonstration of the UI, explanation of the icons on the UI and the mechanism of selection of an icon, through focused visual attention.
Selection of need/ complaint: Immediately following orientation, testing for accuracy of the BCI device will be performed. Testing for accuracy will be performed a single time for each patient, using the most important need/ complaint for that patient. The patient will be asked to identify on the BCI UI the specific need or complaint as being the most common reason to request the assistance of the bedside nurse during their admission, among the 10 patient need/ complaint options provided. Selection of "None of the above/ Other" will be permitted, however, the patient will be specifically instructed in advance to select the need/ complaint most applicable to their situation among the 10 choices provided. The patient will then be asked to select the SAME need/ complaint on the picture board using finger contact.
SPECIFIC AIM 2:
Specific Aim 2: To determine patient, family and bedside nurse satisfaction with communication using the BCI device and elicit open-ended feedback to guide future device improvements.
Hypothesis 2: At least 70% of patients will "agree" or "strongly agree" with the statement "The Brain computer interface device allowed me to communicate my needs to the bedside nurse adequately".
Immediately following evaluation of accuracy described under Specific Aim 1, the investigators will evaluate patient, family and bedside nurse satisfaction following bedside use of the device as the primary communication tool for 2 hours a day for 3 consecutive days. A delirium screen using CAM-ICU and a brief neurological examination to confirm the patient's ability to effectively use the BCI device and picture board will be performed prior to use of the device or picture board on subsequent days (days 2 and 3).
At the end of the 3 days, the patient, any family members present and each nurse who participated in testing will be provided the short questionnaires. The patient questionnaire with options will be read out to the patient.
Statistical Analysis:
The proportion of patients who pass Step 2 of screening who then also pass Step 3 will be calculated with exact binomial 95% confidence intervals. A proportion of at least 70% passing Step 3 of screening will be the initial threshold for feasibility, based on clinical estimates of value. The median time, with interquartile range, required for orientation to the BCI device and to the picture board will be calculated, and comparison performed using the Mann Whitney U-test. The proportion of patients who select the same icon on the BCI UI and the picture board will be calculated, with exact binomial 95% confidence intervals. In determining the accuracy of using the BCI device, a binomial analysis including multiple studies of BCI estimated the chance level at 63% (α = 0.05, 60 trials). Based also on a clinical estimate of what would be a minimum useful level of accuracy for a communication device, the threshold for accuracy in our study will be at least 80% of patients demonstrating concordance between selection of their most important need/ complaint on the BCI device and the picture board. Descriptive statistics will be used to for proportions of patients selecting responses to each of the satisfaction questions.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Brain Computer Interface (BCI) device | Experimental | Device: Brain Computer Interface (BCI) device, Other: Communication picture boardThe patient uses the Brain Computer Interface (BCI) device in the ICU for communication for 2 hours a day for 3 consecutive days. The patient then uses a communication picture board for 2 hours a day for 3 consecutive days on the same days that the BCI device is used for comparison. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Admitted to an Intensive Care Unit and on mechanical ventilation for at least 24 hours
- Age 18 years or older
- Able to briskly follow commands
- Unimpaired use of at least one upper limb
Key exclusion criteria (6 listed)
- Ongoing respiratory distress, severe pain or other source of obvious discomfort requiring immediate medical or nursing attention
- Severe hemodynamic instability with ongoing need for vasopressor titration or resuscitation
- Known impairment of vision, other than error of refraction with corrective lenses present
- Inability to tolerate interruption of sedation
- Inability to communicate fluently in English
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Brain Computer Interface (BCI) deviceA BCI system to facilitate communication in intubated patients. Patients use the device in the ICU for communication for 2 hours a day for 3 consecutive days. | Device | Brain Computer Interface (BCI) device |
| Communication picture boardThe patient then uses a communication picture board for 2 hours a day for 3 consecutive days on the same days that the BCI device is used for comparison. | Other | Brain Computer Interface (BCI) device |
Primary outcome
BCI device accuracy
Time frame: Immediately following enrollment
Accurate selection of the illustrative icon on the brain computer interface representing the physical or emotional need self-identified by the patient as being the most common trigger for communication with the bedside nurse during their admission.
1 secondary outcome
Satisfaction survey
Time frame: At the end of 3 days of using BCI device
Results and safety
The study was stopped early (reason given: The developer of the BCI left the institution so the study could not continue). Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 Apr 2019.
- Background: PubMed 21362711Happ MB, Garrett K, Thomas DD, Tate J, George E, Houze M, Radtke J, Sereika S. Nurse-patient communication interactions in the intensive care unit. Am J Crit Care. 2011 Mar;20(2):e28-40. doi: 10.4037/ajcc2011433.
- Background: PubMed 2403412Johnson MM, Sexton DL. Distress during mechanical ventilation: patients' perceptions. Crit Care Nurse. 1990 Jul-Aug;10(7):48-57. No abstract available.
- Background: PubMed 14984652Carroll SM. Nonvocal ventilated patients perceptions of being understood. West J Nurs Res. 2004 Feb;26(1):85-103; discussion 104-12. doi: 10.1177/0193945903259462.
- Background: PubMed 8705084Baker C, Melby V. An investigation into the attitudes and practices of intensive care nurses towards verbal communication with unconscious patients. J Clin Nurs. 1996 May;5(3):185-92. doi: 10.1111/j.1365-2702.1996.tb00248.x.
- Background: PubMed 16137350Thomason JW, Shintani A, Peterson JF, Pun BT, Jackson JC, Ely EW. Intensive care unit delirium is an independent predictor of longer hospital stay: a prospective analysis of 261 non-ventilated patients. Crit Care. 2005 Aug;9(4):R375-81. doi: 10.1186/cc3729. Epub 2005 Jun 1.
- Background: PubMed 15454792Miglietta MA, Bochicchio G, Scalea TM. Computer-assisted communication for critically ill patients: a pilot study. J Trauma. 2004 Sep;57(3):488-93. doi: 10.1097/01.ta.0000141025.67192.d9.
- Background: PubMed 23174919Maringelli F, Brienza N, Scorrano F, Grasso F, Gregoretti C. Gaze-controlled, computer-assisted communication in Intensive Care Unit: "speaking through the eyes". Minerva Anestesiol. 2013 Feb;79(2):165-75. Epub 2012 Nov 22.
- Background: PubMed 15718541Smith E, Delargy M. Locked-in syndrome. BMJ. 2005 Feb 19;330(7488):406-9. doi: 10.1136/bmj.330.7488.406. No abstract available.
- Background: PubMed 25721542Daly JJ, Huggins JE. Brain-computer interface: current and emerging rehabilitation applications. Arch Phys Med Rehabil. 2015 Mar;96(3 Suppl):S1-7. doi: 10.1016/j.apmr.2015.01.007.
- Background: PubMed 25623294Chaudhary U, Birbaumer N, Curado MR. Brain-machine interface (BMI) in paralysis. Ann Phys Rehabil Med. 2015 Feb;58(1):9-13. doi: 10.1016/j.rehab.2014.11.002. Epub 2015 Jan 8.
- Background: PubMed 18571984Nijboer F, Sellers EW, Mellinger J, Jordan MA, Matuz T, Furdea A, Halder S, Mochty U, Krusienski DJ, Vaughan TM, Wolpaw JR, Birbaumer N, Kubler A. A P300-based brain-computer interface for people with amyotrophic lateral sclerosis. Clin Neurophysiol. 2008 Aug;119(8):1909-1916. doi: 10.1016/j.clinph.2008.03.034. Epub 2008 Jun 20.
- Background: PubMed 25298323Sellers EW, Ryan DB, Hauser CK. Noninvasive brain-computer interface enables communication after brainstem stroke. Sci Transl Med. 2014 Oct 8;6(257):257re7. doi: 10.1126/scitranslmed.3007801.
- A practical VEP-based brain-computer interfaceLink provided by the sponsor.
- BCIBench: A Benchmarking Suite for EEG-based Brain Computer Interface, ODES-11 2014 Workshop on Optimizations for DSP and Embedded Systems, February 15, 2014, Orlando, FLLink provided by the sponsor.
- A Novel Stimulation for Multi-Class SSVEP-Based Brain-Computer Interface Using Patterns of Time-Varying Frequencies, International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), August 26-30, 2014, Chicago, ILLink provided by the sponsor.
- Frequency recognition based on canonical correlation analysis for SSVEP-based BCIsLink provided by the sponsor.
- Individual participant dataSharing planned: No
Related trials for Mechanical Ventilation
Not yet recruiting
The Hemodynamic Impact of High-frequency Oscillatory Ventilation and Periodic Sighs in Preterm Infants
Preterm, Respiratory Distress Syndrome in Premature Infant
Not yet recruitingObservational study
Development and Prospective Validation of the AutoEIT Foundation Model for ARDS
ARDS (Acute Respiratory Distress Syndrome), Respiratory Failure
Not yet recruitingObservational study
Predicting the Need for Invasive Mechanical Ventilation Using Different Risk Scores
High Flow Oxygen Therapy, Non Invasive Ventilation (NIV)
Not yet recruitingObservational study
Early Identification of Pathogens in Children With Respiratory Tract Infection by Mechanical Ventilation Using mNGS
VAP - Ventilator Associated Pneumonia
Not yet recruitingObservational study
Detecting Early Weaning-induced Pulmonary Oedema Using Lung Impedance Negative Trend During Spontaneous Breathing Trials
Weaning-induced Pulmonary Edema, Mechanical Ventilation Weaning
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Omid Dehzanghi, PhD principal investigator
University of Michigan
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Brain Computer Interface (BCI) device and Communication picture board in people with Mechanical Ventilation and Nonverbal Communication, run by University of Michigan at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: stopped early, as of the sponsor's last update on 17 Apr 2019. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was stopped early (reason given: The developer of the BCI left the institution so the study could not continue). Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
BCI device accuracy (time frame: Immediately following enrollment). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02791425, which also lists 19 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Apr 2019.