AzTrials
AzTrials

Multiple SclerosisNCT02772666

Novel Portable Diagnostic Device for Automatic Detection of Relative Afferent Pupillary Defect

A study testing O-Glass and Swinging Flashlight Test in people with Multiple Sclerosis and Glaucoma, run by Mashhad University of Medical Sciences.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study is to evaluate the ability of a newly designed device, Optic Nerve Glass (O-Glass) to detect relative afferent pupillary defect (RAPD). In this prospective study, 44 patients (diagnosed RAPD- positive) enrolled the study. Read more about this study

Who is it for?
Ages 20 to 55 years
Conditions the study is for
Multiple Sclerosis, Glaucoma
What is being tested?
O-Glass and Swinging Flashlight Test
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
44 participants
Where
No sites listed yet
Study dates
Dec 2015to Jun 2016
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 55 years
  • All sexes
  • No healthy volunteers
  • Adult

Who may be able to join

  • positive relative afferent pupillary defect

Who cannot join

  • -

About this study

Official title: New Automatic Portable Ophthalmology Device

This study is to evaluate the ability of a newly designed device, Optic Nerve Glass (O-Glass) to detect relative afferent pupillary defect (RAPD). In this prospective study, 44 patients (diagnosed RAPD- positive) enrolled the study. They were examined for an RAPD by O-Glass and also manual swinging flashlight method (SFM) . This newly designed instrument captures and records eye pictures. The images will be processed and analyzed using computerized software to calculate pupillary measurements.

Read the detailed description

Pupil response to light stimulation is a basic clinical approach to the assessment of a patient with visual loss. Asymmetric response may indicate a relative afferent pupillary defect (RAPD). The rapid detection device for relative afferent pupillary defect (present device) is a newly designed portable facility with computerized software on a mobile device. This allows for field ophthalmic examination and identification of RAPDs quickly and accurately and also record pupillary movements for further processing and analysis or send the information and images via Wi-Fi. We aimed at comparing and evaluating this device with available methods to develop a test which is practically easy and quick with objective results and no need for specialist interpretation, so that any technician can perform the test automatically. Distinctive software allows simple use of the device by field personnel with minimal training. Each patient was investigated by swinging flashlight method and the newly constructed automated O-glass. The swinging flashlight test procedure, also called as Marcus Gunn Test, is well known in ophthalmology science.The hardware for this device includes 4 different parts: Camera and optics, light control system, power control system, and the microcontroller.The two main components of the software are the ability to communicate with the hardware wirelessly, and the pattern recognition system.

Being tested
O-Glass, Swinging Flashlight Test
Keywords
Relative afferent pupillary defect (RAPD), Multiple sclerosis, Glaucoma
Medical subject headings
Multiple Sclerosis, Glaucoma, Pupil Disorders

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • O-GlassDevice

    The new diagnostic device to distinguish relative afferent pupillary defect(RAPD).

  • Swinging Flashlight TestOther

    Also called Other diagnostic method

    The swinging-flashlight test is used to help a practitioner identify a relative afferent pupillary defect.For an adequate test, vision must not be entirely lost. In dim room light, the examiner notes the size of the pupils. The patient is asked to gaze into the distance, and the examiner swings the beam of a penlight back and forth from one pupil to the other, and observes the size of pupils and reaction in the eye that is lit.

Study groups in NCT02772666
Study groupRoleWhat they receive
O-GlassExperimentalAll study participants who were diagnosed Relative Afferent Pupillary defect(RAPD) positive according to expert specialist investigations, were enrolled in this study. They were all examined with new device named O-Glass.
Receives: Device: O-Glass
Swinging Flash light TestActive comparatorAll study participants who were diagnosed Relative Afferent Pupillary defect(RAPD) positive according to expert specialist investigations were also examined with manual diagnostic method, Swinging Flash light Test(SFT). The standard and most common method for Marcus-Gunn test is Swinging Flashlight Test (SFT), which needs a dark room, and the patient will be asked to look toward a distant object, so the pupils are not focused. The patient is asked to gaze into the distance, and the examiner swings the beam of a penlight back and forth from one pupil to the other, and observes the size of pupils and reaction in the eye that is lit.
Receives: Other: Swinging Flashlight Test

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of Participants With Detected Relative Afferent Pupillary Defect (RAPD)

    The instrument illuminated the eyes alternatively and took images and recorded pupillary reflex to this light stimulation.

    All of 44 patients were examined with two methods, SFT and O Glass. SFT method: The well known manual method to diagnose RAPD. O glass method:The device consists of camera and light sources.The red light was on and off for a 5 second interval. Then the white light was on for right eye and 3 seconds later the system captured an image. After 0.5 second the right light was off and the left light turned on, 3 seconds later the image was captured. The images were processed and analyzed using computerized software.

    Measured: up to 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 May 2016 (estimated)
  2. Study startDec 2015
  3. Primary completionMay 2016
  4. Study completionJun 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Non-randomised
Intervention model
Single group
Masking
Double blind
Who is masked
Investigator, Outcomes assessor
Enrolment
44 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02772666
Sponsor's protocol ID
IR.MUMS.REC.1395.15
Status last verified
Nov 2016
First submitted
10 May 2016
Last updated
29 Dec 2016
Data monitoring committee
Yes
Individual data sharing
Undecided: I have not decided about it.

Questions about this trial

What is this clinical trial studying?

A study testing O-Glass and Swinging Flashlight Test in people with Multiple Sclerosis and Glaucoma, run by Mashhad University of Medical Sciences.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 29 Dec 2016. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 1 Nov 2016). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of Participants With Detected Relative Afferent Pupillary Defect (RAPD) (time frame: up to 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Dec 2016.