AzTrials
AzTrials

Respiratory DepressionNCT02760927

Assessment of a Oral Endotracheal Tube Fastener on Patients Intubated With Oral Endotracheal Tubes

A study testing Endotracheal Tube Fastener in people with Respiratory Depression and Respiratory Failure, run by Hollister Incorporated at 3 sites in United States.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Assessment of AnchorFast Guard Oral Endotracheal Tube Fastener on Patients Intubated with Oral Endotracheal Tubes with Subglottic Suction Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Endotracheal Tube Fastener
Could I receive a placebo?
No, everyone receives an active treatment
How many people
4 participants
Where
3 sitesUnited States
Study dates
Mar 2016to May 2016
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Is 18 years of age or older and requires oral tracheal intubation
  • Has intact skin on application site
  • Is qualified to participate in the opinion of the Investigator including the requirement for endotracheal tube with subglottic suction

Who cannot join

  • Has an existing neck injury
  • Has protruding upper teeth, is without teeth or is unable to wear upper dentures
  • Has facial hair
  • Has clinically significant skin damage, condition or disease on the application site which may contraindicate participation
  • Has a known or stated allergy to adhesive bandages, or any of the product types being tested
  • Uses of topical drugs, lotions, creams or oils on the application site
  • Is participating in any clinical testing which may affect performance of this device
  • AnchorFast Guard Oral Endotracheal Tube Fastener does not fit subject's face

Trial locations and contacts

3 sites in 1 country.

United States3 sites
  • Legacy Mt Hood

    Gresham, Oregon, 97030

  • Legacy Good Samaritan

    Portland, Oregon, 97210

  • Legacy Salmon Creek Medical Center

    Vancouver, Washington, 98686

Other trials in United States

About this study

Official title: Assessment of AnchorFast Guard Oral Endotracheal Tube Fastener on Patients Intubated With Oral Endotracheal Tubes With Subglottic Suction

Assessment of AnchorFast Guard Oral Endotracheal Tube Fastener on Patients Intubated with Oral Endotracheal Tubes with Subglottic Suction

Read the detailed description

Endotracheal intubation is the trans laryngeal placement of a tube into the trachea via the nose or mouth. Subglottic suctioning, during endotracheal tube securement, is important for mechanically-ventilated patients to allow for the clearance of secretions that may accumulate during intubation. This protocol examines an enhancement to the current AnchorFast Guard device in order for the device to hold a subglottic suctioning lumen in addition to the intubation tube.

Being tested
Endotracheal Tube Fastener
Medical subject headings
Respiratory Insufficiency

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Endotracheal Tube FastenerDevice

    Also called AnchorFast Guard Oral Endotracheal Tube Fastener

    The AnchorFast Guard oral endotracheal tube fastener provides a convenient means to hold an oral endotracheal tube securely in place without the use of adhesive tape. The oral endotracheal tube fastener allows repositioning of the tube in either direction along the track without removal of the device.

Study groups in NCT02760927
Study groupRoleWhat they receive
Endotracheal Tube FastenerExperimentalThe intervention administered is a revised commercially available endotracheal tube holder with a tract to accommodate a subglottic suction lumen of an oral endotracheal tube.
Receives: Device: Endotracheal Tube Fastener

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Proportion of Participants on Which Test Product Allowed for Proper Placement of the Subglottic Suction Lumen

    Assessed by the proportion of yes/no researcher responses

    Measured: Typical wear time of endotracheal tube fastener up to one week

  2. Proportion of Participants on Which the Subglottic Suction Lumen Was Easy to Place Into the Tract With the Tube Protection Sleeve

    Assessed by the proportion of researcher responses that equal agree (4) plus strongly agree (5) on a five point scale that includes strongly disagree (1) disagree (2) and no opinion (3)

    Measured: Typical wear time of endotracheal tube fastener up to one week

  3. Proportion of Participants on Which the Test Product Allowed the Subglottic Suction Lumen to Remain Within the Subglottic Suction Lumen Tract

    Assessed by the proportion of yes/no researcher responses

    Measured: Typical wear time of endotracheal tube fastener up to one week

  4. Proportion of Participants on Which the Test Product Protected the Subglottic Suction Lumen

    Assessed by the proportion of yes/no researcher responses

    Measured: Typical wear time of endotracheal tube fastener up to one week

  5. Proportion of Participants on Which the Test Product Allowed for Effective Subglottic Suctioning

    Assessed by the proportion of yes/no researcher responses

    Measured: Typical wear time of endotracheal tube fastener up to one week

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 May 2016 (estimated)
  2. Study startMar 2016
  3. Primary completionApr 2016
  4. Study completionMay 2016

Why it stopped: Study product will not be commercialized.

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
4 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02760927
Sponsor's protocol ID
5799-I
Status last verified
Aug 2018
First submitted
18 Apr 2016
Last updated
6 Sep 2018
Data monitoring committee
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Endotracheal Tube Fastener in people with Respiratory Depression and Respiratory Failure, run by Hollister Incorporated at 3 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 6 Sep 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 6 Sep 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Proportion of Participants on Which Test Product Allowed for Proper Placement of the Subglottic Suction Lumen (time frame: Typical wear time of endotracheal tube fastener up to one week). The study lists 5 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Sep 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in