Coronary Heart DiseaseNCT02688868
Evaluation of New Specifications (2.25mm) of FirehawkTM in the Treatment of Coronary Heart Disease ( Firehawk_2.25 )
A study testing FirehawkTM 2.25mm in people with Coronary Heart Disease, run by Shanghai MicroPort Medical (Group) Co., Ltd. at 1 site in China.
Trial summary
The purpose of this study is to evalute the clinical safety and effectiveness of released specification (2.25mm) of FirehawkTM Sirolimus target-eluting coronary stent system. Read more about this study
- Who is it for?
- Ages 18 to 80 years
- Conditions the study is for
- Coronary Heart Disease
- What is being tested?
- FirehawkTM 2.25mm
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 38 participants
- Where
- 1 siteChina
- Study dates
- May 2014to Dec 2020
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- 18-80 years of age, males or non-pregnant women;
- Evidence of silent ischemia, stability or in patients with old myocardial infarction or unstable angina;
- Primary target lesion, in situ coronary artery disease;
- Target lesion length ≤ 60mm, target lesion diameter 2.25mm (Visual method);
- The target lesion diameter stenosis ≥ 70% (Visual method);
- Each target lesion implantation the same stent (Firehawk stent);
- With indications for coronary artery bypass surgery;
- To understand the purpose of testing, voluntary and informed consent, patients agreed to achieve invasive imaging and clinical follow-up.
Who cannot join
- Within 72h of any acute myocardial infarction;
- Unprotected left main coronary artery disease, triple vessel lesions which need treated all; bifurcation lesions and vascular lesions of the bridge;
- Severe calcified lesions that cannot be successfully expanded and distorting lesions not suitable for stent delivery;
- Artery and/or vein bypass graft lesions;
- Intracoronary implantation of any branding stents within 1 year;
- Severe congestive heart failure (NYHA class III and above), or left ventricular ejection fraction <35% (ultrasound or left ventricular angiography);
Show all 13Show fewer
- Preoperative renal function serum creatinine >2.0mg/DL;
- Bleeding, active gastrointestinal ulcers, brain hemorrhage or subarachnoid hemorrhage and half year history of ischemic stroke, antiplatelet agents and would not allow an anticoagulant therapy contraindications patients undergoing antithrombotic therapy;
- Aspirin, clopidogrel, heparin, contrast agent, poly lactic acid polymer and rapamycin allergies;
- The patient's life expectancy is less than 12 months;
- Top participated in other drug or medical device and does not meet the primary study endpoint in clinical trials time frame;
- Researchers determine patient compliance is poor, unable to complete the study in accordance with the requirements;
- Heart transplantation patients.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: The Safety and Effectiveness Evaluation of New Specifications (2.25mm) of FirehawkTM Sirolimus Target-eluting Coronary Stent System in the Treatment of Coronary Heart Disease: a Prospective, Multicenter, Single-group Study.
The purpose of this study is to evalute the clinical safety and effectiveness of released specification (2.25mm) of FirehawkTM Sirolimus target-eluting coronary stent system.
- Conditions
- Coronary Heart Disease
- Being tested
- FirehawkTM 2.25mm
- Medical subject headings
- Coronary Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
FirehawkTM 2.25mmDevice
Implantation of the released specification (2.25mm) of FirehawkTM rapamycin target-eluting coronary stent systems
| Study group | Role | What they receive |
|---|---|---|
| new specifications (Diameter 2.25mm)of Firehawk stent | Experimental | Evaluation of new specifications (Diameter 2.25mm) of FirehawkTM in the treatment of coronary heart disease Receives: Device: FirehawkTM 2.25mm |
What is being measured
The primary outcome is the main question the study is designed to answer.
In-stent Late Loss
the difference between the minimal lumen diameter immediately after stent implantation and the minimal lumen diameter by angiography review 9 months after the procedure.
Measured: 9 month after stent implantation
Secondary outcomes (8)
Number of Participants With Target Lesion Failure
including cardiac death, target vessel myocardial infarction and clinical symptom-driven target lesion revascularization
Measured: 12 months
Number of Participants With Target Lesion Failure
including cardiac death, target vessel myocardial infarction and clinical symptom-driven target lesion revascularization
Measured: 2 years
Number of Participants With Target Lesion Failure
including cardiac death, target vessel myocardial infarction and clinical symptom-driven target lesion revascularization
Measured: 3 years
Number of Participants With Target Lesion Failure
including cardiac death, target vessel myocardial infarction and clinical symptom-driven target lesion revascularization
Measured: 4 years
Number of Participants With MACE
a composite endpoint of all cause death, any myocardial infarction and any revascularization
Measured: 12 months
Number of Participants With MACE
a composite endpoint of all cause death, any myocardial infarction and any revascularization
Measured: 2 years
Number of Participants With MACE
a composite endpoint of all cause death, any myocardial infarction and any revascularization
Measured: 3 years
Number of Participants With MACE
a composite endpoint of all cause death, any myocardial infarction and any revascularization
Measured: 4 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted23 Feb 2016 (estimated)
- Study startMay 2014
- Primary completionDec 2015
- Study completionDec 2020
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for Coronary Heart DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 38 participants (actual)
Sponsor and investigators
- Lead sponsor
- Shanghai MicroPort Medical (Group) Co., Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Runlin Gao, MD, Principal investigator, Fu Wai Hospital & National Center for Cardiovascular Diseases in China
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02688868
- Sponsor's protocol ID
- Firehawk_SS
- Status last verified
- May 2020
- First submitted
- 18 Feb 2016
- Last updated
- 23 Oct 2023
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 23 Oct 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The Safety and Effectiveness Evaluation of New Specifications (2.25mm) of FirehawkTM Sirolimus Target-eluting Coronary Stent System in the Treatment of Coronary Heart Disease: a Prospective, Multicenter, Single-group Study.
- ClinicalTrials.gov ID
- NCT02688868
- Acronym / sponsor ID
- Firehawk_SS
- Conditions
- Coronary Heart Disease
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 38 participants (actual)
- Lead sponsor
- Shanghai MicroPort Medical (Group) Co., Ltd.Industry (pharma, biotech, devices)
- Study start
- May 2014 (actual)
- Primary completion
- Dec 2015 (actual)
- Study completion
- Dec 2020 (actual)
- First posted
- 23 Feb 2016 (estimated)
- Results
- Posted 20 Feb 2020
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to evalute the clinical safety and effectiveness of released specification (2.25mm) of FirehawkTM Sirolimus target-eluting coronary stent system.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| new specifications (Diameter 2.25mm)of Firehawk stent | Experimental | Device: FirehawkTM 2.25mmEvaluation of new specifications (Diameter 2.25mm) of FirehawkTM in the treatment of coronary heart disease |
Who may qualify
- Ages
- 18 to 80 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (8 listed)
- 18-80 years of age, males or non-pregnant women;
- Evidence of silent ischemia, stability or in patients with old myocardial infarction or unstable angina;
- Primary target lesion, in situ coronary artery disease;
- Target lesion length ≤ 60mm, target lesion diameter 2.25mm (Visual method);
- The target lesion diameter stenosis ≥ 70% (Visual method);
Key exclusion criteria (13 listed)
- Within 72h of any acute myocardial infarction;
- Unprotected left main coronary artery disease, triple vessel lesions which need treated all; bifurcation lesions and vascular lesions of the bridge;
- Severe calcified lesions that cannot be successfully expanded and distorting lesions not suitable for stent delivery;
- Artery and/or vein bypass graft lesions;
- Intracoronary implantation of any branding stents within 1 year;
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| FirehawkTM 2.25mmImplantation of the released specification (2.25mm) of FirehawkTM rapamycin target-eluting coronary stent systems | Device | new specifications (Diameter 2.25mm)of Firehawk stent |
Primary outcome
In-stent Late Loss
Time frame: 9 month after stent implantation
the difference between the minimal lumen diameter immediately after stent implantation and the minimal lumen diameter by angiography review 9 months after the procedure.
8 secondary outcomes
Number of Participants With Target Lesion Failure
Time frame: 12 months
Number of Participants With Target Lesion Failure
Time frame: 2 years
Number of Participants With Target Lesion Failure
Time frame: 3 years
Number of Participants With Target Lesion Failure
Time frame: 4 years
Number of Participants With MACE
Time frame: 12 months
Number of Participants With MACE
Time frame: 2 years
Number of Participants With MACE
Time frame: 3 years
Number of Participants With MACE
Time frame: 4 years
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 23 Oct 2023.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: No
Related trials for Coronary Heart Disease
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
RecruitingObservational study
AI-powered ECG Analysis Using Willem™ Software in High-risk Cardiac Patients (WILLEM)
Cardiomyopathies, Cardiac Arrest
RecruitingPhase 4
The Effects of Ferric Derisomaltose in Patients With Acute Heart Failure and Iron Deficiency on Exercise Capacity and Quality of Life(COREVIVE-HFrEF)
Heart Failure With Reduced Ejection Fraction, Iron Deficiency
Recruiting
Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR
Aortic Stenosis Treated With TAVI, Aortic Diseases
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Runlin Gao, MD principal investigator
Fu Wai Hospital & National Center for Cardiovascular Diseases in China
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing FirehawkTM 2.25mm in people with Coronary Heart Disease, run by Shanghai MicroPort Medical (Group) Co., Ltd. at 1 site in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 8 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 23 Oct 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 20 Feb 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
In-stent Late Loss (time frame: 9 month after stent implantation). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Oct 2023.