Trial summary

The purpose of this study is to evalute the clinical safety and effectiveness of released specification (38mm) of FirehawkTM Sirolimus target-eluting coronary stent system. Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Coronary Heart Disease
What is being tested?
Rapamycin target-eluting coronary stent systems (38mm)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
38 participants
Where
1 siteChina
Study dates
May 2014to Jan 2021
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • 18-80 years of age, males or non-pregnant women;
  • Evidence of silent ischemia, stability or in patients with old myocardial infarction or unstable angina;
  • Primary target lesion, in situ coronary artery disease;
  • Target lesion length ≤ 60mm, target lesion diameter 2.75mm or 4.0mm (Visual method);
  • The target lesion diameter stenosis ≥ 70% (Visual method);
  • Each target lesion implantation the same stent (Firehawk stand);
  • With indications for coronary artery bypass surgery;
  • To understand the purpose of testing, voluntary and informed consent, patients undergoing invasive imaging follow-up.

Who cannot join

  • Within 72h of any acute myocardial infarction;
  • Unprotected left main coronary artery disease, triple vessel lesions which need treated all;
  • Severe calcified lesions that cannot be successfully expanded and distorting lesions not suitable for stent delivery;
  • Artery and/or vein bypass graft lesions;
  • Intracoronary implantation of any branding stents within 1 year;
  • Severe congestive heart failure (NYHA class III and above), or left ventricular ejection fraction <35% (ultrasound or left ventricular angiography);
Show all 13Show fewer
  • Preoperative renal function serum creatinine >2.0mg/DL;
  • Bleeding, active gastrointestinal ulcers, brain hemorrhage or subarachnoid hemorrhage and half year history of ischemic stroke, antiplatelet agents and would not allow an anticoagulant therapy contraindications patients undergoing antithrombotic therapy;
  • Aspirin, clopidogrel, heparin, contrast agent, poly lactic acid polymer and rapamycin allergies;
  • The patient's life expectancy is less than 12 months;
  • Top participated in other drug or medical device and does not meet the primary study endpoint in clinical trials time frame;
  • Researchers determine patient compliance is poor, unable to complete the study in accordance with the requirements;
  • Heart transplantation patients.

Trial locations and contacts

1 site in 1 country.

China1 site
  • Fu Wai Hospital

    Beijing, Beijing Municipality, 100037

Other trials in China

About this study

Official title: The Safety and Effectiveness Evaluation of New Specifications (38mm) of FirehawkTM Sirolimus Target-eluting Coronary Stent System in the Treatment of Coronary Heart Disease: a Prospective, Multicenter, Single-group Study.

The purpose of this study is to evalute the clinical safety and effectiveness of released specification (38mm) of FirehawkTM Sirolimus target-eluting coronary stent system.

Being tested
Rapamycin target-eluting coronary stent systems (38mm)
Medical subject headings
Coronary Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Rapamycin target-eluting coronary stent systems (38mm)Device

    Also called Firehawk-38

Study groups in NCT02688842
Study groupRoleWhat they receive
treatment groupExperimentalImplantation of the released specification (38mm) of FirehawkTM rapamycin target-eluting coronary stent systems
Receives: Device: Rapamycin target-eluting coronary stent systems (38mm)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. In-stent Late Lumen Loss

    Measured: 9 month after stent implantation

Secondary outcomes (12)
  1. Participants With Target Lesion Failure

    a composite endpoint of cardiac death, myocardial infarction related to target vessel (TVMI) and clinically-indicated revascularization related to target lesion (CI-TLR)

    Measured: 30 days after stent implantation

  2. Participants With Target Lesion Failure

    a composite endpoint of cardiac death, myocardial infarction related to target vessel (TVMI) and clinically-indicated revascularization related to target lesion (CI-TLR)

    Measured: 6months after stent implantation

  3. Participants With Target Lesion Failure

    a composite endpoint of cardiac death, myocardial infarction related to target vessel (TVMI) and clinically-indicated revascularization related to target lesion (CI-TLR)

    Measured: 12 months after stent implantation

  4. Participants With Target Lesion Failure

    a composite endpoint of cardiac death, myocardial infarction related to target vessel (TVMI) and clinically-indicated revascularization related to target lesion (CI-TLR)

    Measured: 2 years after stent implantation

  5. Participants With Target Lesion Failure

    a composite endpoint of cardiac death, myocardial infarction related to target vessel (TVMI) and clinically-indicated revascularization related to target lesion (CI-TLR)

    Measured: 3 years after stent implantation

  6. Participants With Target Lesion Failure

    a composite endpoint of cardiac death, myocardial infarction related to target vessel (TVMI) and clinically-indicated revascularization related to target lesion (CI-TLR)

    Measured: 4 years after stent implantation

  7. Major Adverse Cardiac Events

    composite endpoint of all cause death, any myocardial infarction and any revascularization

    Measured: 30 days after stent implantation

  8. Major Adverse Cardiac Events

    composite endpoint of all cause death, any myocardial infarction and any revascularization

    Measured: 6 months after stent implantation

  9. Major Adverse Cardiac Events

    composite endpoint of all cause death, any myocardial infarction and any revascularization

    Measured: 12 months after stent implantation

  10. Major Adverse Cardiac Events

    composite endpoint of all cause death, any myocardial infarction and any revascularization

    Measured: 2 years after stent implantation

  11. Major Adverse Cardiac Events

    composite endpoint of all cause death, any myocardial infarction and any revascularization

    Measured: 3 years after stent implantation

  12. Major Adverse Cardiac Events

    composite endpoint of all cause death, any myocardial infarction and any revascularization

    Measured: 4 years after stent implantation

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted23 Feb 2016 (estimated)
  2. Study startMay 2014
  3. Primary completionJan 2016
  4. Study completionJan 2021

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
all patients implanted Firehawk stent of new specification (38mm long)
Masking
None (open label)
Enrolment
38 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02688842
Sponsor's protocol ID
Firehawk_LS
Acronym
Firehawk_38
Status last verified
May 2021
First submitted
18 Feb 2016
Last updated
23 Oct 2023
Data monitoring committee
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Rapamycin target-eluting coronary stent systems (38mm) in people with Coronary Heart Disease, run by Shanghai MicroPort Medical (Group) Co., Ltd. at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 8 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 23 Oct 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 20 Feb 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

In-stent Late Lumen Loss (time frame: 9 month after stent implantation). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Oct 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in