Staff AnaesthesiologistsNCT02640196

Videolaryngoscopes for Double Lumen Tube Intubations in Simulated Easy and Difficult Airway

A study testing Macintosh, GlideScope and Airtraq in people with Staff Anaesthesiologists and Limited Experience in Using Videolaryngoscopes, run by Imam Abdulrahman Bin Faisal University at 1 site in Saudi Arabia.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The investigators hypothesized that the use of the King Vision™ and the Airtraq® VL would reduce the time to DLT intubation compared with the GlideScope® and Macintosh in simulated easy and difficult airways. Read more about this study

Who is it for?
Ages 23 to 65 yearsHealthy volunteers can take part
What is being tested?
Macintosh, GlideScope and Airtraq
Type of treatment
Medical device
Could I receive a placebo?
Yes, some participants may receive a placebo
How many people
21 participants
Where
1 siteSaudi Arabia
Study dates
Mar 2015to Jun 2015
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 23 to 65 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Staff anesthesiologists
  • Signed consent
  • Limited experience in using videolaryngoscopes for inserting double lumen tubes

Who cannot join

  • Decline to sign the consent
  • Non receiving the prior training demonstration
  • Non practicing once with each device tested on each simulator scenario

Trial locations and contacts

1 site in 1 country.

Saudi Arabia1 site
  • Dammam University KFHU

    Khobar, EP, 31952

Other trials in Saudi Arabia

About this study

Official title: A Comparison of Three Videolaryngoscopes for Double-lumen Tubes Intubation in Simulated Easy and Difficult Airways

The investigators hypothesized that the use of the King Vision™ and the Airtraq® VL would reduce the time to DLT intubation compared with the GlideScope® and Macintosh in simulated easy and difficult airways. The investigators have considered to assess the efficacy of each device in manikins before considering to evaluate them in patients undergoing thoracic procedures.

Twenty-one staff anaesthesiologists who had limited prior experience in using the VLs for DLT intubation participated in this randomised crossover study. Following a brief demonstration and two practice attempts, participants were volunteered to insert a DLT using the Macintosh, GlideScope®, Airtraq®, and King Vision™ on two high-fidelity easy and difficult airway simulators in a computer-generated randomized sequence. The primary endpoint, time to DLT intubation, as well as, the views obtained at laryngoscopy, ease of intubation, numbers of laryngoscopy attempts and optimisation manoeuvers, and failure to intubation; defined as an attempt took longer than 150 seconds, were recorded.

Read the detailed description

Several regional surveys demonstrated that most thoracic anesthesiologists are using the double-lumen endobronchial tubes (DLT) as the first-choice lung separation technique. DLT, when compared with single lumen tracheal tube, can be more difficult to insert in patients with difficult airways. The videolaryngoscopes (VL) have the potential to facilitate the placement of the DLTs for lung separation in patients with predicted or unanticipated difficult airway.

The use of GlideScope® (Verathon Inc., Bothell, WA, USA), a VL with an angulated blade, has been associated with variable times to DLT intubation according to the prior experience of the operators, despite superior visualization of the glottis The channeled Airtraq® (Prodol Meditec S.A., Vizcaya, Spain) and standard non-channeled blade of the King Vision™ (Ambu, Ballerup, Copenhagen, Denmark), may offer additional benefits for DLT intubation in patients with limited mouth opening or restricted neck movement, in whom the use of traditional VL like as the Glidescope® could be difficult. This is because of the larger outer diameter, the distal curvature and the increased rigidity of the DLT. Of note, the longer times to DLT intubation with the use of different VL could be shortened with building up the operator's experience.

To the best of the investigators knowledge, the comparison of the effects of the Macintosh, GlideScope®, Airtraq®, and King Vision™ VL on the time to DLT intubation in simulated easy and difficult airways has not yet been studied.

Two high-fidelity simulators (Airway Management Trainer, model AA-3100, Laerdal, Kent, UK) were prepared to simulate easy and difficult airway situations, as described by Marshall et al. and Wang et al. The "easy" airway was established with the manikin in a neutral position. The "difficult" airway setting was obtained by placing an Oasis Elite™ Prone Head Rest, Adult (140 mm in height) (Covidien, Mansfield, MA) under the occiput and securing the head position with adhesive tape, object to replicate cervical-collar use. Positioning was confirmed after each attempt to ensure consistency.

Being tested
Macintosh, GlideScope, Airtraq, King Vision
Keywords
Laryngoscope, Macintosh, Glidescope, King Vision, Airtraq, Double Lumen Tube

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • MacintoshDevice

    The participants intubated the easy airway simulator with a double lumen tube using the Macintosh laryngoscope followed with intubating the difficult airway simulator

  • GlideScopeDevice

    The participants intubated the easy airway simulator with a double lumen tube using the GlideScope followed with intubating the difficult airway simulator

  • AirtraqDevice

    The participants intubated the easy airway simulator with a double lumen tube using the Airtraq followed with intubating the difficult airway simulator

  • King VisionDevice

    The participants intubated the easy airway simulator with a double lumen tube using the King Vision followed with intubating the difficult airway simulator

Study groups in NCT02640196
Study groupRoleWhat they receive
MacintoshPlacebo comparatorThe participants intubated the easy airway simulator with a double lumen tube using the Macintosh laryngoscope followed with intubating the difficult airway simulator
Receives: Device: Macintosh
GlideScopePlacebo comparatorThe participants intubated the easy airway simulator with a double lumen tube using the GlideScope laryngoscope followed with intubating the difficult airway simulator
Receives: Device: GlideScope
AirtraqActive comparatorThe participants intubated the easy airway simulator with a double lumen tube using the Airtraq laryngoscope followed with intubating the difficult airway simulator
Receives: Device: Airtraq
King VisionActive comparatorThe participants intubated the easy airway simulator with a double lumen tube using the King Vision followed with intubating the difficult airway simulator
Receives: Device: King Vision

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time to achieve successful double lumen tube intubation

    defined as the time when the investigated laryngoscope passed the central incisors to when the tip of the bronchial lumen passed through the glottis, as confirmed visually by the operator (in the Macintosh group) or by the investigator, thanks to remote screens (in the VLs groups).

    Measured: for 6 min after using each device

Secondary outcomes (4)
  1. Best view during laryngoscopy using the classification described by Cormack and Lehane

    using the classification described by Cormack and Lehane

    Measured: for 1 min after laryngoscopy

  2. Difficulty of intubation using a Visual Analog Scale (VAS)

    The difficulty of intubation was evaluated using a visual analog scale (VAS) (ranging from 0: extremely easy, to 100: extremely difficult) expressed by the anesthesiologists after the DLT intubation

    Measured: for 6 min after using each device

  3. Number of first-pass success

    first-pass success calculated as number of first-attempt successes/number of patients with an intubation attempt

    Measured: for 3 min after using each device

  4. Number of the required optimisation manoeuvers

    When the anaesthesiologists encountered difficulty in visualising vocal cords or placing the tube, they were allowed to use any manoeuver they would normally use to navigate the tube into the trachea including readjustment of the blade or tube or to ask the supervising investigator to help solve the problem, and gave suggestions or instructions

    Measured: for 6 min after using each device

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Dec 2015 (estimated)
  2. Study startMar 2015
  3. Primary completionMay 2015
  4. Study completionJun 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
21 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02640196
Sponsor's protocol ID
ANESTH-03-15
Status last verified
Dec 2015
First submitted
22 Dec 2015
Last updated
28 Dec 2015
Results posted
No
Data monitoring committee
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Macintosh, GlideScope and Airtraq in people with Staff Anaesthesiologists and Limited Experience in Using Videolaryngoscopes, run by Imam Abdulrahman Bin Faisal University at 1 site in Saudi Arabia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 28 Dec 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Saudi Arabia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Time to achieve successful double lumen tube intubation (time frame: for 6 min after using each device). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Dec 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in