A study testing Radiation: 15 FPS Cine 15 PPS, Radiation: 7.5 low Frame rate and Low Cine in people with Stable Angina and Unstable Angina, run by University Health Network, Toronto at 1 site in Canada.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The investigators sought to investigate the efficacy of low frame rate (fluoroscopy at 7.5 frames per second (FPS) and Cine at 10 pulse per second (PPS) vs. conventional (15 FPS and 15 PPS) on radiation dose to the patient and the operator during coronary angiography and intervention. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Radiation: 15 FPS Cine 15 PPS, Radiation: 7.5 low Frame rate and Low Cine
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
600 participants
Where
1 siteCanada
Study dates
Jul 2015to Jul 2016
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients undergoing elective or urgent cardiac catheterisation with or without ad-hoc PCI or planned PCI in the pre-specified catheterisation laboratories.

Who cannot join

  • Patients who undergo procedures other than diagnostic coronary angiography or intervention (e.g. electrophysiological procedures).
  • Patients participating in other research study requiring higher cine angiography.
  • ST-elevation Myocardial Infarction

Trial locations and contacts

1 site in 1 country.

Divyesh Sharma, MSc,MRCP contact

001-647-961-9336

divyeshsharma11@gmail.com

Ashish H Shah, MD, MD(Res) contact

001-416-835-2822

ashish.shah@uhn.ca

Canada1 site
  • University Health Network - Peter Munk Cardiac Centre

    Toronto, Ontario

Other trials in Canada

About this study

Official title: Impact of Low Frame Rate Fluoroscopy and Cine-angiography on Reducing Operator and Patient Radiation Dose and Impact on Image Quality During Cardiac Catheterization

The investigators sought to investigate the efficacy of low frame rate (fluoroscopy at 7.5 frames per second (FPS) and Cine at 10 pulse per second (PPS) vs. conventional (15 FPS and 15 PPS) on radiation dose to the patient and the operator during coronary angiography and intervention. In addition, investigators sought to qualitatively assess the effect, if any, of the low frame rate on angiographic image quality.

Read the detailed description

Minimizing radiation exposure to patient and the operator is considered one of the primary safety concerns in the catheterization laboratory. Patients undergoing diagnostic angiography +/- ad hoc PCI or planned PCI, will be randomised to conventional settings (15 FPS and 15 PPS) or low frame rate settings (7.5 FPS and 15 PPS) or low Cine settings (7.5 FPS and 10 PPS). The patient radiation dose, patient radiation dose area product (DAP), and fluoroscopy time will be measured.

Statistical Analysis:

Demographic and procedural variables will be presented as percentage (categorical variable) or mean ± SD (continuous variable). Patients will be randomized into three arms - a control arm and two intervention arms. The angiographic radiation protocol will adhere to standard practice in both fluoroscopy and cine images at 15 frames/second. The intervention arm will consist of two groups. Group 1 with fluoroscopy images set at 7.5 frames/second and cine images set at 15 frames/second and group 2 with fluoroscopy set at 7.5 frames/second and cine set at 10 frames/second.

Sample size calculations are based on assuming a reduction in radiation dose in group 1 of 10% and in group 2 of 20%. At 5% significance and 80% power, a sample size of 200 patients will be required in each intervention arm. Allowing for a 10% attrition rate, a sample size of 220 patients will be required in each intervention arm with 100 patients in the control arm.

Being tested
Radiation: 15 FPS Cine 15 PPS, Radiation: 7.5 low Frame rate, Low Cine
Keywords
radiation, fluoroscopy, diagnostic
Medical subject headings
Angina, Stable, Angina, Unstable, Acute Coronary Syndrome, Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Radiation: 15 FPS Cine 15 PPSRadiation

    Also called Conventional

    Radiation 15 FPS Cine 15 PPS

  • Radiation: 7.5 low Frame rateRadiation

    Also called Low rate fluoroscopy

    Radiation: Frame rate 7.5 FPS, Cine 15 PPS

  • Low CineRadiation

    Also called Low pulse rate Cine

    Radiation: Frame rate 7.5 FPS, Cine 10 PPS

Study groups in NCT02574949
Study groupRoleWhat they receive
Conventional rate fluoroscopyActive comparatorRadiation: 15 FPS Cine 15 PPS
Receives: Radiation: Radiation: 15 FPS Cine 15 PPS
Intermediate frame rate 7.5 fpsExperimentalRadiation: 7.5 low Frame rate
Receives: Radiation: Radiation: 7.5 low Frame rate
Low frame rateExperimentalLow Cine 10 PPS
Receives: Radiation: Low Cine

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Radiation Exposure to patient

    Radiation exposure to patient will be measured by Dose-Area product (DAP) collected during the procedure.

    Measured: During Cardiac catheterization procedure

Secondary outcomes (1)
  1. Image quality assessment of the coronary angiogram

    Coronary angiograms will be assessed by blinded operators for quality of image using a pre-specified tool

    Measured: 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Oct 2015 (estimated)
  2. Study startJul 2015
  3. Primary completionJul 2016 (estimated)
  4. Study completionJul 2016 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Health services research
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
600 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02574949
Sponsor's protocol ID
15-8832-AE
Status last verified
Oct 2015
First submitted
26 May 2015
Last updated
14 Oct 2015
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Radiation: 15 FPS Cine 15 PPS, Radiation: 7.5 low Frame rate and Low Cine in people with Stable Angina and Unstable Angina, run by University Health Network, Toronto at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 14 Oct 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Divyesh Sharma, MSc,MRCP (001-647-961-9336, divyeshsharma11@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Radiation Exposure to patient (time frame: During Cardiac catheterization procedure). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Oct 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in