AzTrials
AzTrials

Haemodynamic PhysiologyMuscle PumpNCT02532556

Electrical Stimulation of the Muscle Pumps of the Leg

A study testing Electrical stimulation (Digitimer) in people with Haemodynamic Physiology, run by Imperial College London.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The most efficient way of electrically stimulating the calf muscles has not been identified. The investigators aim to investigate this using a matrix of electrical parameters, and measuring the outcome with vascular ultrasound of the leg. Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Haemodynamic Physiology
What is being tested?
Electrical stimulation (Digitimer)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
12 participants
Where
No sites listed yet
Study dates
May 2015to Aug 2015
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • 18 years or older
  • Current good health

Who cannot join

  • History of cardiovascular disease
  • Ankle Brachial Pressure Index <0.9
  • Venous reflux>0.5s
  • Pregnancy

About this study

The most efficient way of electrically stimulating the calf muscles has not been identified. The investigators aim to investigate this using a matrix of electrical parameters, and measuring the outcome with vascular ultrasound of the leg.

Read the detailed description

Blood is aided on its journey to the heart by the action of the muscles of the legs. Muscle contraction squeezes the deep veins of the leg and pushes blood upwards, back towards the heart. In immobilised patients, or those with blood vessel problems, the pumping process can be helped by machines that either squeeze or shock the muscles of the calf (e.g. intermittent pneumatic compression, electrical stimulating devices). Many are licensed for medical use, and some are common place in hospitals and outpatient departments.

Being tested
Electrical stimulation (Digitimer)
Keywords
Haemodynamic physiology

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Electrical stimulation (Digitimer)Device

    Stimulation with Digitimer (DS7A HV, Digitimer Ltd, UK) over motor point of muscle in protocol. 1Hz, pulse duration 1ms, maximum compliance voltage 200V. Current set to twice motor threshold

Study groups in NCT02532556
Study groupRoleWhat they receive
1ExperimentalStimulation of muscle in this order: vastus medials, rectus femoris, vastus lateralis, tibialis anterior, peroneus longus, medial head gastrocnemius, lateral head gastrocnemius
Receives: Device: Electrical stimulation (Digitimer)
2ExperimentalStimulation of muscle in this order: rectus femoris, vastus lateralis, tibialis anterior, peroneus longus, medial head gastrocnemius, lateral head gastrocnemius, vastus medials
Receives: Device: Electrical stimulation (Digitimer)
3ExperimentalStimulation of muscle in this order: vastus lateralis, tibialis anterior, peroneus longus, medial head gastrocnemius, lateral head gastrocnemius, vastus medials, rectus femoris
Receives: Device: Electrical stimulation (Digitimer)
4ExperimentalStimulation of muscle in this order: tibialis anterior, peroneus longus, and the medial head gastrocnemius, lateral head gastrocnemius, vastus medials, rectus femoris, vastus lateralis
Receives: Device: Electrical stimulation (Digitimer)
5ExperimentalStimulation of muscle in this order: peroneus longus, medial head gastrocnemius, lateral head gastrocnemius, vastus medials, rectus femoris, vastus lateralis, tibialis anterior
Receives: Device: Electrical stimulation (Digitimer)
6ExperimentalStimulation of muscle in this order: medial head gastrocnemius, lateral head gastrocnemius, vastus medials, rectus femoris, vastus lateralis, tibialis anterior, peroneus longus
Receives: Device: Electrical stimulation (Digitimer)
7ExperimentalStimulation of muscle in this order: lateral head gastrocnemius, vastus medials, rectus femoris, vastus lateralis, tibialis anterior, peroneus longus, medial head gastrocnemius,
Receives: Device: Electrical stimulation (Digitimer)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Venous Haemodynamic Measurements (Volume Flow Rate)

    Measurement by ultrasound, in right femoral vein. Flow rate (ml/min).

    Measured: Baseline compared to that after 10-mins stimulation (2-mins to take measurements)

  2. Venous Haemodynamic Measurements (Time Averaged Maximum Velocity)

    Measurement by ultrasound, in right femoral vein. Time averaged maximum velocity (cm/s).

    Measured: Baseline compared to that after 10-mins stimulation (2-mins to take measurements)

Secondary outcomes (1)
  1. Pain Grading on Stimulation

    Visual analogue scale (0-minimum pain, to 100-maximum pain)

    Measured: During stimulation (10-mins each muscle)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Aug 2015 (estimated)
  2. Study startMay 2015
  3. Primary completionAug 2015
  4. Study completionAug 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Basic science
Allocation
Non-randomised
Intervention model
Single group
Masking
Triple blind
Who is masked
Participant, Investigator, Outcomes assessor
Enrolment
12 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02532556
Sponsor's protocol ID
15IC2528
Acronym
Muscle Pump
Status last verified
Nov 2020
First submitted
10 Aug 2015
Last updated
27 Nov 2020
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Evans DR, Williams KJ, Strutton PH, Davies AH. The comparative hemodynamic efficacy of lower limb muscles using transcutaneous electrical stimulation. J Vasc Surg Venous Lymphat Disord. 2016 Apr;4(2):206-14. doi: 10.1016/j.jvsv.2015.10.009. Epub 2016 Jan 12.

    PubMed 26993869

Questions about this trial

What is this clinical trial studying?

A study testing Electrical stimulation (Digitimer) in people with Haemodynamic Physiology, run by Imperial College London.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 27 Nov 2020. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 27 Nov 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Venous Haemodynamic Measurements (Volume Flow Rate) (time frame: Baseline compared to that after 10-mins stimulation (2-mins to take measurements)). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02532556, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Nov 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in