Cardiac Diagnostic ProcedurePhase 4NCT02438475
The Safety and Efficacy of an Extravascular, Water-Soluble Sealant for Venous Access-Site Closure
A Phase 4 study testing Mynx Vascular Closure System and Manual Compression in people with Cardiac Diagnostic Procedure and Cardiac Interventional Procedure, run by Medstar Health Research Institute at 2 sites in United States.
Trial summary
Evaluate the safety of the MynxGrip™ extravascular sealant for common femoral vein closure following both diagnostic and interventional procedures as assessed by clinical and imaging criteria. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Cardiac Diagnostic Procedure, Cardiac Interventional Procedure, Femoral Access Site Closure
- What is being tested?
- Mynx Vascular Closure System and Manual Compression
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 208 participants
- Where
- 2 sitesUnited States
- Study dates
- Jun 2015to Aug 2017
- Phase
- Phase 4
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Patients > 18 years of age scheduled for a percutaneous diagnostic or interventional procedure that have either a 5, 6, or 7F sheath placed in the common femoral vein.
Who cannot join
- Patient has a history of a bleeding disorder
- Previous history of venous thrombosis or thromboembolism
- Patient is pregnant or lactating
- Patient has a known severe allergy to contrast medium
- Patient has a known allergy to PEG
- 7. Patient is known to require an extended hospitalization or re-hospitalization (e.g. patient is undergoing coronary artery bypass graft (CABG) surgery) or patient is scheduled to have a CABG surgery <30 days following the procedure) 9. Multiple (>1) attempts at venous access were attempted in the target vein 10. Patient has intra-procedural bleeding around the access site prior to sheath removal 11. Critically ill patients requiring intravenous vasopressors for blood pressure stabilization 12. Ipsilateral femoral artery puncture or sheath insertion 13. Glycoprotein IIb/IIIIa use 14. Any bleeding or vascular access-site complication evident pre-venous closure
Trial locations and contacts
2 sites in 1 country.
United States2 sites
MedStar Southern Maryland Hospital
Clinton, Maryland, 20735
MedStar Washington Hospital Center
Washington D.C., District of Columbia, 20010
About this study
Evaluate the safety of the MynxGrip™ extravascular sealant for common femoral vein closure following both diagnostic and interventional procedures as assessed by clinical and imaging criteria.
Read the detailed description
The objective of this study is to evaluate the safety of the MynxGrip™ extravascular sealant for common femoral vein closure following both diagnostic and interventional procedures as assessed by clinical and imaging criteria for venous thrombosis at the site of closure device deployment.
This is a single-center prospective study of patients who are undergoing either diagnostic or interventional procedures. A total of 208 patients will be enrolled in this study and will be followed through hospital discharge for safety purposes.
The primary safety endpoint will include both deep venous thrombotic and bleeding/vascular injury related complications prior to discharge. Outcomes will be assessed via clinical evaluation and imaging with clinically indicated as follow:
Assessment of venous thrombosis i. Clinical: Physical exam findings consistent with venous thrombotic/thromboembolic related complication:
- Redness or swelling at the venous puncture site
- Increased lower extremity edema
- Calf pain
- New onset or worsening shortness of breath
- New onset of pleuritic chest pain ii. and if clinically indicated, imaging: venous Doppler ultrasound assessment of obstructive or non-obstructive deep vein thrombosis (DVT)
- Bleeding or vascular related complications i. Damage to the vessel requiring surgical repair ii. Access site bleeding requiring the need for transfusion iii. Nerve injury at access site iv. Generalized infection (septicemia with typical signs, symptoms and positive blood cultures shortly after the index procedure, and requiring treatment with intravenous (IV) antibiotics)Pseudo-aneurysms requiring invasive treatment
- Device/procedure failure Device failure is defined as either the inability to deploy the device or device deployment with inadequate hemostasis requiring conversion to immediate manual pressure, or the eventual need for alternative methods to obtain hemostasis.
Efficacy will be assessed by time to hemostasis; Time to hemostasis is defined as the time from advancer tube removal (i.e., device removal) to the time when hemostasis was first observed.
The study will be conducted following either diagnostic or interventional procedures where venous access was required (via the common femoral vein with insertion of 5, 6, or 7F sheath). Femoral vein hemostasis will be achieved with either manual compression or the MynxGrip VCD system. To assess the primary safety outcome of venous patency and lack of occurrence of DVT, clinical assessment will be performed by the study team vascular access assessment group and when clinically indicated a duplex ultrasound will be performed on patients prior to discharge to evaluation the presence of venous thrombosis.
After enrollment, subjects will be randomized 1:1 to:
- Treatment Group A: Subjects will have venous hemostasis achieved using the MynxGrip vascular closure system in the common femoral vein.
- Treatment Group B: Subjects will have venous hemostasis achieved using manual compression over the common femoral vein.
Subjects who meet all inclusion criteria and none of the exclusion criteria, who agree to participate in this clinical study, and who sign an informed consent will be enrolled.
The patient will undergo the clinically indicated procedure(s) as per standard of care. The type of procedure(s) performed will be collected within the CRF. Once all the clinically indicated procedures have been completed the following assessment will be made with respect to the inclusion criteria:
- Target vein had a maximal sheath size inserted larger that 7Fr
- Multiple (>1) attempts at venous access were attempted in the target vein
- Patient has intra-procedural bleeding around the access site prior to sheath removal
- Critically ill patients requiring intravenous vasopressors for blood pressure stabilization
- Ipsilateral femoral artery puncture or sheath insertion
- Glycoprotein IIb/IIIIa use
- Any bleeding or vascular access-site complication evident pre-venous closure If any of the above are met, then the patient will be considered a screen failure. If one femoral vein was attempted with one or more access attempts with or without sheath insertion and then the contralateral femoral vein is used to gain venous access, the target vein for closure would become the vein with one attempt to achieve access that also fits the inclusion/ exclusion criteria above.
Randomization and Enrollment Once the patient meets all the inclusion criteria and none of the exclusion criteria he/she will be considered enrolled in the study.
Randomization will be performed in a block size of 4 within site to maintain the 1:1 randomization throughout the trial within two patients. Randomization will be assigned in consecutive order for the patient enrollment ID starting with 001 through 208. The randomization assignment will be stored within an opaque envelope and assigned/opened in numerical order.
Study Devices/ Procedures
For the randomization assignments both commercial product will be uses. Please follow the commercial IFU for deployment and/or positioning of the Mynx Vascular Closure. For manual compression please follow the local institutions standard of care for the procedure.
Follow-up Patients will be followed up though hospital discharge to assess the primary safety outcome of deep vein thrombotic and/or bleeding/vascular injury related complications related to the target venous closure site.
To assess this primary safety outcome of venous patency and lack of occurrence of DVT, a clinical assessment this includes the following by systematic physician assessment of the target groin.
Once the patient is placed in the recovery room following the completion of the procedure, a member of the Mynx Grip study team will be called to assess the groin, which includes the information below;
Assessment of Venous Thrombosis:
- Comparing mid calf and mid thigh measurement prior to and post procedure.
- Redness or selling at the venous puncture site
- Physical exam findings consistent with venous thrombotic/thromboembolic related complications (i.e. vein engorgement, presence of chord, syenosis)
- Increased lower extremity edema
- New onset or worsening shortness of breath
- New onset of pleuritic chest pain
Bleeding or Vascular Related complications:
- Damage to the vessel requiring surgical repair
- Access site bleeding requiring the need for transfusion
- Nerve injury at the access site
- Generalized infection
- Pseudo-aneurysms requiring invasive treatment In the event that the Mynx Grip study team believes that further assessment for venous thrombosis of the target femoral vein is necessary, a duplex ultrasound of the target femoral vein will be ordered.
Presence of a venous thrombosis of the target vein will be assessed based on a combination of clinical symptoms and/or result of the duplex ultrasounds. Duplex ultrasounds will be submitted to and assessed by the Duplex Ultrasound Core Lab for a systematic and objective review of the presence of venous thrombosis
- Conditions
- Cardiac Diagnostic Procedure, Cardiac Interventional Procedure, Femoral Access Site Closure
- Being tested
- Mynx Vascular Closure System, Manual Compression
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Mynx Vascular Closure SystemDevice
Also called MynxGrip Vascular Closure Device
MynxGrip is being used to seal femoral vein access sites while reducing times to hemostasis and ambulation in patients who have undergone diagnostic or interventional endovascular procedures utilizing a 5F, 6F or 7F procedural sheath.
Manual CompressionOther
manual pressure applied to your groin for approximately 5-10 minutes
| Study group | Role | What they receive |
|---|---|---|
| Mynx Vascular Closure System | Active comparator | Where subjects will have venous hemostasis attempted to be achieved using the Mynx Vascular Closure system alone Receives: Device: Mynx Vascular Closure System |
| Manual Compression | Other | Where patients will have venous hemostasis attempted to be achieved using manual compression alone Receives: Other: Manual Compression |
What is being measured
The primary outcome is the main question the study is designed to answer.
Assessment of Venous Thrombosis
- Clinical: Physical exam findings consistent with venous thrombotic/thromboembolic related complication:
- Redness or swelling at the venous puncture site
- Increased lower extremity edema
- Calf pain
- New onset or worsening shortness of breath
- New onset of pleuritic chest pain ii. and if clinically indicated, imaging: venous Doppler ultrasound assessment of obstructive or non-obstructive deep vein thrombosis (DVT)
Measured: Subjects will be followed up until their discharge from the hospital, and expected average of 24 hours
Bleeding or Vascular Related Complications
- Damage to the vessel requiring surgical repair ii. Access site bleeding requiring the need for transfusion iii. Nerve injury at access site iv. Generalized infection (septicemia with typical signs, symptoms and positive blood cultures shortly after the index procedure, and requiring treatment with intravenous (IV) antibiotics)Pseudo-aneurysms requiring invasive treatment
Measured: Subjects will be followed up until their discharge from the hospital, and expected average of 24 hours
Device/Procedure Failure
Device failure is defined as either the inability to deploy the device or device deployment with inadequate hemostasis requiring conversion to immediate manual pressure, or the eventual need for alternative methods to obtain hemostasis.
Measured: intraoperative
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted8 May 2015 (estimated)
- Study startJun 2015
- Primary completionAug 2017
- Study completionAug 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (5)Papers the sponsor has linked to this study.
- Other trials for Cardiac Diagnostic ProcedureStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 4
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 208 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medstar Health Research Institute
- Sponsor type
- University, hospital or other
- Collaborators
- Cardinal Health
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02438475
- Sponsor's protocol ID
- Vascular Closure Venous Mynx
- Status last verified
- Oct 2020
- First submitted
- 30 Apr 2015
- Last updated
- 18 Nov 2020
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
Publications
McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med. 2003 Mar 20;348(12):1123-33. doi: 10.1056/NEJMra011883. No abstract available.
PubMed 12646670Tavris DR, Dey S, Albrecht-Gallauresi B, Brindis RG, Shaw R, Weintraub W, Mitchel K. Risk of local adverse events following cardiac catheterization by hemostasis device use - phase II. J Invasive Cardiol. 2005 Dec;17(12):644-50.
PubMed 16327045Marso SP, Amin AP, House JA, Kennedy KF, Spertus JA, Rao SV, Cohen DJ, Messenger JC, Rumsfeld JS; National Cardiovascular Data Registry. Association between use of bleeding avoidance strategies and risk of periprocedural bleeding among patients undergoing percutaneous coronary intervention. JAMA. 2010 Jun 2;303(21):2156-64. doi: 10.1001/jama.2010.708.
PubMed 20516416Scheinert D, Sievert H, Turco MA, Schmidt A, Hauptmann KE, Mueller R, Dadourian D, Krankenberg H, Grube E. The safety and efficacy of an extravascular, water-soluble sealant for vascular closure: initial clinical results for Mynx. Catheter Cardiovasc Interv. 2007 Nov 1;70(5):627-33. doi: 10.1002/ccd.21353.
PubMed 17960627Zahn R, Fromm E, Thoma S, Lotter R, Zander M, Wagner S, Seidl K, Senges J. Local venous thrombosis after cardiac catheterization. Angiology. 1997 Jan;48(1):1-7. doi: 10.1177/000331979704800101.
PubMed 8995337
Study at a glance
From the registry record, last updated by the sponsor on 18 Nov 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The Safety and Efficacy of an Extravascular, Water-Soluble Sealant for Venous Access-Site Closure
- ClinicalTrials.gov ID
- NCT02438475
- Acronym / sponsor ID
- Vascular Closure Venous Mynx
- Conditions
- Cardiac Diagnostic Procedure, Cardiac Interventional Procedure, Femoral Access Site Closure
- Phase
- Phase 4
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 208 participants (actual)
- Lead sponsor
- Medstar Health Research InstituteUniversity, hospital or other
- Collaborators
- Cardinal Health
- Study start
- Jun 2015
- Primary completion
- Aug 2017 (actual)
- Study completion
- Aug 2017 (actual)
- First posted
- 8 May 2015 (estimated)
- Results
- Posted 18 Nov 2020
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Evaluate the safety of the MynxGrip™ extravascular sealant for common femoral vein closure following both diagnostic and interventional procedures as assessed by clinical and imaging criteria.
Detailed description
The objective of this study is to evaluate the safety of the MynxGrip™ extravascular sealant for common femoral vein closure following both diagnostic and interventional procedures as assessed by clinical and imaging criteria for venous thrombosis at the site of closure device deployment.
This is a single-center prospective study of patients who are undergoing either diagnostic or interventional procedures. A total of 208 patients will be enrolled in this study and will be followed through hospital discharge for safety purposes.
The primary safety endpoint will include both deep venous thrombotic and bleeding/vascular injury related complications prior to discharge. Outcomes will be assessed via clinical evaluation and imaging with clinically indicated as follow:
Assessment of venous thrombosis i. Clinical: Physical exam findings consistent with venous thrombotic/thromboembolic related complication:
- Redness or swelling at the venous puncture site
- Increased lower extremity edema
- Calf pain
- New onset or worsening shortness of breath
- New onset of pleuritic chest pain ii. and if clinically indicated, imaging: venous Doppler ultrasound assessment of obstructive or non-obstructive deep vein thrombosis (DVT)
- Bleeding or vascular related complications i. Damage to the vessel requiring surgical repair ii. Access site bleeding requiring the need for transfusion iii. Nerve injury at access site iv. Generalized infection (septicemia with typical signs, symptoms and positive blood cultures shortly after the index procedure, and requiring treatment with intravenous (IV) antibiotics)Pseudo-aneurysms requiring invasive treatment
- Device/procedure failure Device failure is defined as either the inability to deploy the device or device deployment with inadequate hemostasis requiring conversion to immediate manual pressure, or the eventual need for alternative methods to obtain hemostasis.
Efficacy will be assessed by time to hemostasis; Time to hemostasis is defined as the time from advancer tube removal (i.e., device removal) to the time when hemostasis was first observed.
The study will be conducted following either diagnostic or interventional procedures where venous access was required (via the common femoral vein with insertion of 5, 6, or 7F sheath). Femoral vein hemostasis will be achieved with either manual compression or the MynxGrip VCD system. To assess the primary safety outcome of venous patency and lack of occurrence of DVT, clinical assessment will be performed by the study team vascular access assessment group and when clinically indicated a duplex ultrasound will be performed on patients prior to discharge to evaluation the presence of venous thrombosis.
After enrollment, subjects will be randomized 1:1 to:
- Treatment Group A: Subjects will have venous hemostasis achieved using the MynxGrip vascular closure system in the common femoral vein.
- Treatment Group B: Subjects will have venous hemostasis achieved using manual compression over the common femoral vein.
Subjects who meet all inclusion criteria and none of the exclusion criteria, who agree to participate in this clinical study, and who sign an informed consent will be enrolled.
The patient will undergo the clinically indicated procedure(s) as per standard of care. The type of procedure(s) performed will be collected within the CRF. Once all the clinically indicated procedures have been completed the following assessment will be made with respect to the inclusion criteria:
- Target vein had a maximal sheath size inserted larger that 7Fr
- Multiple (>1) attempts at venous access were attempted in the target vein
- Patient has intra-procedural bleeding around the access site prior to sheath removal
- Critically ill patients requiring intravenous vasopressors for blood pressure stabilization
- Ipsilateral femoral artery puncture or sheath insertion
- Glycoprotein IIb/IIIIa use
- Any bleeding or vascular access-site complication evident pre-venous closure If any of the above are met, then the patient will be considered a screen failure. If one femoral vein was attempted with one or more access attempts with or without sheath insertion and then the contralateral femoral vein is used to gain venous access, the target vein for closure would become the vein with one attempt to achieve access that also fits the inclusion/ exclusion criteria above.
Randomization and Enrollment Once the patient meets all the inclusion criteria and none of the exclusion criteria he/she will be considered enrolled in the study.
Randomization will be performed in a block size of 4 within site to maintain the 1:1 randomization throughout the trial within two patients. Randomization will be assigned in consecutive order for the patient enrollment ID starting with 001 through 208. The randomization assignment will be stored within an opaque envelope and assigned/opened in numerical order.
Study Devices/ Procedures
For the randomization assignments both commercial product will be uses. Please follow the commercial IFU for deployment and/or positioning of the Mynx Vascular Closure. For manual compression please follow the local institutions standard of care for the procedure.
Follow-up Patients will be followed up though hospital discharge to assess the primary safety outcome of deep vein thrombotic and/or bleeding/vascular injury related complications related to the target venous closure site.
To assess this primary safety outcome of venous patency and lack of occurrence of DVT, a clinical assessment this includes the following by systematic physician assessment of the target groin.
Once the patient is placed in the recovery room following the completion of the procedure, a member of the Mynx Grip study team will be called to assess the groin, which includes the information below;
Assessment of Venous Thrombosis:
- Comparing mid calf and mid thigh measurement prior to and post procedure.
- Redness or selling at the venous puncture site
- Physical exam findings consistent with venous thrombotic/thromboembolic related complications (i.e. vein engorgement, presence of chord, syenosis)
- Increased lower extremity edema
- New onset or worsening shortness of breath
- New onset of pleuritic chest pain
Bleeding or Vascular Related complications:
- Damage to the vessel requiring surgical repair
- Access site bleeding requiring the need for transfusion
- Nerve injury at the access site
- Generalized infection
- Pseudo-aneurysms requiring invasive treatment In the event that the Mynx Grip study team believes that further assessment for venous thrombosis of the target femoral vein is necessary, a duplex ultrasound of the target femoral vein will be ordered.
Presence of a venous thrombosis of the target vein will be assessed based on a combination of clinical symptoms and/or result of the duplex ultrasounds. Duplex ultrasounds will be submitted to and assessed by the Duplex Ultrasound Core Lab for a systematic and objective review of the presence of venous thrombosis
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Mynx Vascular Closure System | Active comparator | Device: Mynx Vascular Closure SystemWhere subjects will have venous hemostasis attempted to be achieved using the Mynx Vascular Closure system alone |
| Manual Compression | Other | Other: Manual CompressionWhere patients will have venous hemostasis attempted to be achieved using manual compression alone |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- Patients > 18 years of age scheduled for a percutaneous diagnostic or interventional procedure that have either a 5, 6, or 7F sheath placed in the common femoral vein.
Key exclusion criteria (6 listed)
- Patient has a history of a bleeding disorder
- Previous history of venous thrombosis or thromboembolism
- Patient is pregnant or lactating
- Patient has a known severe allergy to contrast medium
- Patient has a known allergy to PEG
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Mynx Vascular Closure SystemAlso: MynxGrip Vascular Closure DeviceMynxGrip is being used to seal femoral vein access sites while reducing times to hemostasis and ambulation in patients who have undergone diagnostic or interventional endovascular procedures utilizing a 5F, 6F or 7F procedural sheath. | Device | Mynx Vascular Closure System |
| Manual Compressionmanual pressure applied to your groin for approximately 5-10 minutes | Other | Manual Compression |
Primary outcome
Assessment of Venous Thrombosis
Time frame: Subjects will be followed up until their discharge from the hospital, and expected average of 24 hours
i. Clinical: Physical exam findings consistent with venous thrombotic/thromboembolic related complication: * Redness or swelling at the venous puncture site * Increased lower extremity edema * Calf pain * New onset or worsening shortness of breath * New onset of pleuritic chest pain ii. and if clinically indicated, imaging: venous Doppler ultrasound assessment of obstructive or non-obstructive deep vein thrombosis (DVT)
Bleeding or Vascular Related Complications
Time frame: Subjects will be followed up until their discharge from the hospital, and expected average of 24 hours
i. Damage to the vessel requiring surgical repair ii. Access site bleeding requiring the need for transfusion iii. Nerve injury at access site iv. Generalized infection (septicemia with typical signs, symptoms and positive blood cultures shortly after the index procedure, and requiring treatment with intravenous (IV) antibiotics)Pseudo-aneurysms requiring invasive treatment
Device/Procedure Failure
Time frame: intraoperative
Device failure is defined as either the inability to deploy the device or device deployment with inadequate hemostasis requiring conversion to immediate manual pressure, or the eventual need for alternative methods to obtain hemostasis.
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 18 Nov 2020.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Results publication: PubMed 12646670McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med. 2003 Mar 20;348(12):1123-33. doi: 10.1056/NEJMra011883. No abstract available.
- Results publication: PubMed 16327045Tavris DR, Dey S, Albrecht-Gallauresi B, Brindis RG, Shaw R, Weintraub W, Mitchel K. Risk of local adverse events following cardiac catheterization by hemostasis device use - phase II. J Invasive Cardiol. 2005 Dec;17(12):644-50.
- Results publication: PubMed 20516416Marso SP, Amin AP, House JA, Kennedy KF, Spertus JA, Rao SV, Cohen DJ, Messenger JC, Rumsfeld JS; National Cardiovascular Data Registry. Association between use of bleeding avoidance strategies and risk of periprocedural bleeding among patients undergoing percutaneous coronary intervention. JAMA. 2010 Jun 2;303(21):2156-64. doi: 10.1001/jama.2010.708.
- Results publication: PubMed 17960627Scheinert D, Sievert H, Turco MA, Schmidt A, Hauptmann KE, Mueller R, Dadourian D, Krankenberg H, Grube E. The safety and efficacy of an extravascular, water-soluble sealant for vascular closure: initial clinical results for Mynx. Catheter Cardiovasc Interv. 2007 Nov 1;70(5):627-33. doi: 10.1002/ccd.21353.
- Results publication: PubMed 8995337Zahn R, Fromm E, Thoma S, Lotter R, Zander M, Wagner S, Seidl K, Senges J. Local venous thrombosis after cardiac catheterization. Angiology. 1997 Jan;48(1):1-7. doi: 10.1177/000331979704800101.
Related trials for Cardiac Diagnostic Procedure
RecruitingObservational study
Product Surveillance Registry
Cardiac Rhythm Disorders, Urological Disorders
Enrolling by invitation
Deep Learning Enhanced Detection of Aortic Stenosis - The DETECT-AS-Diagnostic Study
Aortic Stenosis
RecruitingPhase 2
High Cardiovascular Risk Intervention With Cardio-Oncology Consultation for Prostate Cancer Following Androgen Receptor Pathway Inhibitor (ARPI) Therapy (Heart-Safe)
Prostate Cancer (Diagnosis), Prostate Cancer Stage IV
Not yet recruiting
OPTIMized Diagnosis and Treatment System Based on AI and Multimodal Imaging Fusion for PCI (OPTIMAI-PCI)
Coronary Artery Disease
Recruiting
A Prospective Diagnostic Trial of Al[¹⁸F]F-NOTA-folate PET in Patients With Suspected Cardiac Sarcoidosis and Infective Endocarditis
Cardiac Sarcoidosis, Infective Endocarditis
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
2 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 4 study testing Mynx Vascular Closure System and Manual Compression in people with Cardiac Diagnostic Procedure and Cardiac Interventional Procedure, run by Medstar Health Research Institute at 2 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 18 Nov 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
Yes. Results are posted in the registry (first posted 18 Nov 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Assessment of Venous Thrombosis (time frame: Subjects will be followed up until their discharge from the hospital, and expected average of 24 hours). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02438475, which also lists 5 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Nov 2020.