CirrhosisNCT02389127
Relationship Between HbA1c and Chronic Glycemia in Patients With Cirrhosis
An observational study of Cirrhosis and Diabetes Mellitus, Type 2, run by University of Arkansas at 1 site in United States.
Trial summary
Cirrhosis and advanced liver disease have been associated with an increased risk for hyperglycemia and type 2 diabetes mellitus (T2DM). The diagnostic yield of common tests used to define diabetes and insulin resistance in the general population differs significantly from the one observed in patients with liver… Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Cirrhosis, Diabetes Mellitus, Type 2
- What is being tested?
- Continuous glucose monitor (Dexcom, San Diego, CA)
- Type of treatment
- Medical device
- How many people
- 50 participants
- Where
- 1 siteUnited States
- Study dates
- Jul 2015to 1 Jun 2017
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Study population: Patients with cirrhosis with and without T2DM
Who may be able to join
- Group A
- Cirrhosis, either clinically- or biopsy-proven
- Child-Pugh-Turcotte (CTP) A, B, and C (only biopsy-proven in the case of CTP-A)
- Random glucose <200 mg/dL on at least 3 occasions
- No use of insulin or any hypoglycemic agent
- Group B
Show all 15Show fewer
- Cirrhosis, either clinically- or biopsy-proven
- Child-Pugh-Turcotte (CTP) A, B, and C (only biopsy-proven in the case of CTP-A)
- Prior diagnosis of T2DM as based on any of ADA criteria
- Use of insulin or any hypoglycemic agent
- Control Group
- Age 18 to 75
- No known chronic liver disease
- Prior diagnosis of T2DM as based on any of ADA criteria
- Use of insulin or any hypoglycemic agent
Who cannot join
- Hemoglobin <10 mg/dL
- Any transfusional requirement within 3 months before inclusion.
- High-dose vitamin C
- Cr ≥1.3
- Hepatocellular carcinoma (any stage)
- Any splanchnic thrombosis (portal, mesenteric, or splenic)
Show all 10Show fewer
- Persistent or difficult-to-treat hepatic encephalopathy
- Refractory ascites
- Status post-TIPS
- Status post-liver transplant
Trial locations and contacts
1 site in 1 country.
United States1 site
University of Arkansas for Medical Sciences
Little Rock, Arkansas, 72205
About this study
Official title: Relationship Between HbA1c and Chronic Glycemia in Patients With Cirrhosis: a Pilot Study to Better Characterize and Standardize the Test
Cirrhosis and advanced liver disease have been associated with an increased risk for hyperglycemia and type 2 diabetes mellitus (T2DM). The diagnostic yield of common tests used to define diabetes and insulin resistance in the general population differs significantly from the one observed in patients with liver disease. Glycosylated hemoglobin A1c (HbA1c), a reliable test to assess chronic glycemia and recommended both for the diagnosis and monitoring of T2DM, is neither accurate nor reliable in patients with cirrhosis. A validation study has not been performed to define its true usefulness in the setting of cirrhosis. The study aims to determine the level of HbA1c that better corresponds to the diagnosis of T2DM - as determined by an oral glucose tolerance test (OGTT) - and to correlate the levels of HbA1c with the average glucose over a 12-week period in patients with cirrhosis and known T2DM, in cirrhotic patients with different degrees of liver impairment as compared to patients with T2DM and no liver disease.
Read the detailed description
Glycosylated hemoglobin A1c (HbA1c), a reliable test to assess chronic glycemia and recommended both for the diagnosis and monitoring of T2DM, is neither accurate nor reliable in patients with cirrhosis. A validation study has not been performed to define its true usefulness in the setting of cirrhosis. The study aims to determine the level of HbA1c that better corresponds to the diagnosis of T2DM - as determined by an oral glucose tolerance test (OGTT) - and to correlate the levels of HbA1c with the average glucose over a 12-week period in patients with cirrhosis and known T2DM, in cirrhotic patients with different degrees of liver impairment. This study is designed as a pilot, observational, cross-sectional (Group A - cirrhotics with no T2DM) and longitudinal study (Group B - cirrhotics with known diabetes). For our first aim (Group A) the diagnostic yield of HbA1c for T2DM will be compared to that of an OGTT. Regarding the second aim (Group B) HbA1c will be compared to glucose reading from a continuous glucose monitor. In both groups, the following study labs will be performed: fructosamine, Complete Blood Count (CBC), liver function tests, chemistry, International Normalized Ratio (INR), and pre albumin. A total of 26 patients per group will be included.
STUDY AIMS
The study will look into three primary aims:
- To determine the level of HbA1c that better corresponds to the diagnosis of T2DM - as determined by an OGTT - in cirrhotic patients with different degrees of liver impairment.
- Will test the hypothesis of lower levels of HbA1c being found in T2DM in patients with decompensated cirrhosis when compared to those with compensated disease.
- To correlate the levels of HbA1c with the average glucose (AG) over a 12-week period in patients with cirrhosis and known T2DM, according to different degrees of liver impairment.
- Will test the hypothesis of progressively lower levels of HbA1c being associated with hyperglycemia in diabetic patients with decompensated cirrhosis when compared to those with compensated disease.
- To compare the performance of continuous glucose monitoring, particularly the level of agreement between the AG over a 12-week period and HbA1c, in patients with cirrhosis and known T2DM with that of controls with T2DM but no known chronic liver disease (including cirrhosis).
As secondary aims will:
- Determine the prevalence of T2DM in cirrhotics with different degrees of liver disease according to use of fasting glucose, HbA1c, or OGTT.
- Determine the level of HbA1c that better defines well-controlled diabetes in patients with cirrhosis and known T2DM, according to different degrees of liver impairment.
- Glucose variability in patients with cirrhosis and T2DM with that of patients with T2DM but no chronic liver disease (including cirrhosis).
Study Procedures
All patients will be identified and recruited from any of the Liver or GI clinics in the Outpatient Center, UAMS. To test the first aim (Group A) - the cross-sectional part of the study - patients with cirrhosis and varying degrees of liver dysfunction but no prior diagnosis of T2DM will have an OGTT performed after overnight fasting (8-12 hours). The OGTT consists of taking a baseline glucose determination, followed by a second one 2 hours after swallowing a 75-g glucose load. HbA1c will be obtained before OGTT (with baseline glucose) along with the following tests: HbA1c, fructosamine, insulin, CBC, HFP, GGT, OP Chem 7, INR, and prealbumin. Anthropometrics (height, weight, and waist circumference) will be obtained as well (Research Visit 1, see calendar).
All patients will be identified and recruited from any of the Liver or GI clinics in the Outpatient Center, UAMS. For the second aim (Group B) - the longitudinal part of the study - patients with known diabetes and cirrhosis with varying degrees of liver dysfunction will wear a continuous glucose monitor (Dexcom, San Diego, CA) for ≥3 continuous days during week days and week ends, every 4 weeks for 12 consecutive weeks, according to the manufacturer's recommendations. The continuous glucose monitor will record patient's glucose from the odd to the even research visit (i.e. from 1 to 2, 3 to 4, 5 to 6, and 7 to 8). On the last day the continuous glucose monitor is retrieved by the investigators, patients will have the following blood tests performed after overnight fasting (8-12 hours): HbA1c, fructosamine, CBC, HFP, GGT, BMP, INR, and prealbumin. Anthropometrics (height, weight, and waist circumference) will be obtained as well (Research Visit 8, see calendar). In order not to affect glucose control during the study period glucose reads from the continuous glucose monitor will not be disclosed to the patient until the end of the study.
All controls will be identified from the Endocrinology or Internal Medicine clinics in the Outpatient Center, UAMS. Controls will wear a continuous glucose monitor (Dexcom, San Diego, CA) for ≥3 continuous days during week days and week ends, every 4 weeks for 12 consecutive weeks, according to the manufacturer's recommendations. The continuous glucose monitor will record patient's glucose from the odd to the even research visit (i.e. from 1 to 2, 3 to 4, 5 to 6, and 7 to 8). On the last day the continuous glucose monitor is retrieved by the investigators, patients will have the following blood tests performed after overnight fasting (8-12 hours): HbA1c, CBC, and a metabolic profile; as per standard of care recommendations. Anthropometrics (height, weight, and waist circumference) will be obtained as well (Research Visit 8, see calendar - this research visit will occur on the same day of a diabetes follow up outpatient visit). In order not to affect glucose control during the study period glucose reads from the continuous glucose monitor will not be disclosed to the patient until the end of the study.
Given that the study only attempts to investigate the accuracy of HbA1c by comparing it to glucose and other biomarkers, no specific therapeutic interventions or recommendations concerning treatment of diabetes will be required during the study.
Sample Size
Since there is no precedent in the literature showing preliminary data to allow for sample calculation, will include 30 patients for each of the CTP stages A, B, and C, for both groups. This number should allow more than the minimum needed to perform correlation analyses (between and within groups) with confidence.
Sample Size
Since there is no precedent in the literature showing preliminary data to allow for sample calculation, will aim to have complete data on 26 patients per group (10 CTP A, 8 CTP B, and 8 CTP C in each group). However, given that the estimated attrition rate in Group B is 30%, will aim to recruit up to 34 patients for this group. We are planning on recruiting one control for each subject in control B, so that the number of controls would not exceed 34. Thus, the total number of subjects in study will be no more than 94. This number should allow more than the minimum needed to perform correlation analyses (between and within groups) with confidence.
Data Analysis
All glucose determinations from the continuous glucose monitoring will be summarized as an arithmetic mean. Shapiro-Wilk will be used to determine normal distribution of data. Receiver operation characteristic (ROC) curves will be constructed to determine the best cut-off to diagnose T2DM, using OGTT results as the gold standard. Spearman's or Pearson's correlation coefficient will be used to compare HbA1c to average glucose (eAG). Bland-Altman will be used to determine agreement. The estimated average glucose from HbA1c will be derived from a linear regression model, as previously described. Linear regression models will be performed to identify factors affecting HbA1c for both Groups A and B, such as hemoglobin, CTP, MELD, total protein, and prealbumin. CTP will be transformed to dummy variables for this analysis.
Data collection and handling Apart from the data generated by the study, demographics and clinical information to properly classify the hepatic functional and diabetes of each participant will be retrieved from the electronic medical record (EMR). Such information will include results from standard of care laboratories, imaging, and other special studies (EGD), to calculate Child-Turcotte-Pugh (CTP) and MELD scores.
A database will be created to accumulate all of the clinical information generated during this study. No identifiers, apart from name and Date of Birth(DOB), will be collected. All data will be stored in databases kept in a study folder created at PI's computer (password-protected). Main database will include identification (ID) assigned, and once an analytic table is created, all PHI will be removed from the table (after approval by the PI). Only this de-identified dataset with unique study ID's will be used for statistical analyses. Therefore, the risk to the privacy of the individuals will be minimized.
The access to the research folder and its contents will be restricted to the research staffs listed in this submission form. The PHI will be kept in the main database for no more than 10 years. The main database containing PHI will be kept in the study folder and will be never transferred out without de-identification of the data. No hard copy research data will be generated in this project.
Risks and Benefits
The risks associated with venipuncture and repeated blood collection from a vein are minor bleeding, bruising, infection (a small risk any time the skin is broken), or needing more than one attempt to locate veins.
There are no risks to the OGTT, although subjects may not like the taste of the highly concentrated glucose beverage. Occasionally someone may have low blood sugar or high blood sugar after the test. Blood glucose will be monitored before and during the test.
Some risks associated with the Dexcom G4 System Device have been reported: placing the devices in your skin may cause some anxiety, pain, irritation, redness, and swelling. There is also the risk of infection, excessive bleeding, or hematoma (swelling filled with blood caused by a broken blood vessel) - these risks are rare. Removing the sensor may also cause some discomfort or irritation because of the tape used. This reaction usually goes away within a few hours, but may last up to a week. There may be some itching in the area, which is a normal healing response.
In rare cases, the sensor may break while inserted. If this happens, the study team and will examine the area. Sometimes the study team may decide to leave the sensor fragment in place. If there is redness, pain, or infection, the study team will decide how to treat it. You should not try to remove the sensor yourself if it is broken unless the study team tells you to.
the University of Arkansas (UAMS) firewall and only used for specific research purposes in this project. Aggregated data will be analyzed and published, but specific data elements will not be made available. Further, subjects will not forfeit any rights by participating - their health care and eligibility for health benefits will not be affected in any way. Although a breach in confidentiality is always a risk when collecting personal information from patients, we believe this is small given the system that has been developed to obtain and handle data.
Ethics This study will be conducted according to US and international standards of Good Clinical Practice (FDA regulations) for all studies. Applicable government regulations, University of Arkansas for Medical Sciences research policies and procedures will also be followed. This protocol and any amendments will be submitted and approved by the University of Arkansas for Medical Sciences Institutional Review Board (IRB) to conduct the study. All subjects for this study will be provided a consent form describing this study and providing sufficient information in language suitable for subjects to make an informed decision about their participation in this study. The formal consent of a subject, using the IRB-approved consent form, will be obtained before that subject is submitted to any study procedure. This consent form must be signed by the subject or legally acceptable surrogate, and the investigator-designated research professional obtaining the consent.
- Conditions
- Cirrhosis, Diabetes Mellitus, Type 2
- Being tested
- Continuous glucose monitor (Dexcom, San Diego, CA)
- Keywords
- Cirrhosis, Diabetes Mellitus, Type 2, Glycosylated hemoglobin A1c, Glucose
- Medical subject headings
- Fibrosis, Diabetes Mellitus, Type 2
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Continuous glucose monitor (Dexcom, San Diego, CA)Device
(Group B) patients with known diabetes and cirrhosis with varying degrees of liver dysfunction will wear a continuous glucose monitor (Dexcom, San Diego, CA) for 2 continuous days during week days and week ends, every 4 weeks for 12 consecutive weeks.
| Study group | Role | What they receive |
|---|---|---|
| Group A | * Cirrhosis, either clinically- or biopsy-proven * Child-Pugh-Turcotte (CTP) A, B, and C (only biopsy-proven in the case of CTP-A) * Random glucose <200 mg/dL on at least 3 occasions * No use of insulin or any hypoglycemic agent (Group A) patients with cirrhosis and varying degrees of liver dysfunction but no prior diagnosis of T2DM will have an OGTT performed after overnight fasting (8-12-hours). HbA1c will be obtained before OGTT along with the following tests: HbA1c, fructosamine, insulin, CBC, HFP, GGT, OP Chem 7, INR, and prealbumin. | |
| Group B | * Cirrhosis, either clinically- or biopsy-proven
* Child-Pugh-Turcotte (CTP) A, B, and C (only biopsy-proven in the case of CTP-A)
* Prior diagnosis of T2DM as based on any of ADA criteria
* Use of insulin or any hypoglycemic agent
(Group B) patients with known diabetes and cirrhosis with varying degrees of liver dysfunction will wear a continuous glucose monitor (?Dexcom, ?Medtronic) for 2 continuous days during week days and week ends, every 4 weeks for 12 consecutive weeks. On the day the continuous monitor is retrieved by the investigators, patients will have the following blood tests performed after overnight fasting (8-12-hours): HbA1c, fructosamine, CBC, HFP, GGT, BMP, INR, and prealbumin. Receives: Device: Continuous glucose monitor (Dexcom, San Diego, CA) | |
| Control | * Age 18 to 75
* No known chronic liver disease
* Prior diagnosis of T2DM as based on any of ADA criteria
* Use of insulin or any hypoglycemic agent Receives: Device: Continuous glucose monitor (Dexcom, San Diego, CA) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Level of HbA1c in T2DM and cirrhosis
Patients with cirrhosis and varying degrees of liver dysfunction but no prior diagnosis of T2DM will have an OGTT performed after overnight fasting (8-12-hours).
Measured: 12 weeks
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted17 Mar 2015 (estimated)
- Study startJul 2015
- Primary completion1 Jun 2017
- Study completion1 Jun 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for CirrhosisStudies of the same condition, open and under way.
- More trials run by University of ArkansasThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case-control
- Time perspective
- Prospective
- Enrolment
- 50 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Arkansas
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Andres Duarte-Rojo, MD, PhD, Principal investigator, University of Arkansas
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02389127
- Sponsor's protocol ID
- 203867
- Status last verified
- Nov 2017
- First submitted
- 26 Feb 2015
- Last updated
- 7 Nov 2017
- Results posted
- No
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 7 Nov 2017. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Relationship Between HbA1c and Chronic Glycemia in Patients With Cirrhosis: a Pilot Study to Better Characterize and Standardize the Test
- ClinicalTrials.gov ID
- NCT02389127
- Acronym / sponsor ID
- 203867
- Conditions
- Cirrhosis, Diabetes Mellitus, Type 2
- Keywords
- Cirrhosis, Diabetes Mellitus, Type 2, Glycosylated hemoglobin A1c, Glucose
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 50 participants (actual)
- Lead sponsor
- University of ArkansasUniversity, hospital or other
- Study start
- Jul 2015
- Primary completion
- 1 Jun 2017 (actual)
- Study completion
- 1 Jun 2017 (actual)
- First posted
- 17 Mar 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Cirrhosis and advanced liver disease have been associated with an increased risk for hyperglycemia and type 2 diabetes mellitus (T2DM). The diagnostic yield of common tests used to define diabetes and insulin resistance in the general population differs significantly from the one observed in patients with liver disease. Glycosylated hemoglobin A1c (HbA1c), a reliable test to assess chronic glycemia and recommended both for the diagnosis and monitoring of T2DM, is neither accurate nor reliable in patients with cirrhosis. A validation study has not been performed to define its true usefulness in the setting of cirrhosis. The study aims to determine the level of HbA1c that better corresponds to the diagnosis of T2DM - as determined by an oral glucose tolerance test (OGTT) - and to correlate the levels of HbA1c with the average glucose over a 12-week period in patients with cirrhosis and known T2DM, in cirrhotic patients with different degrees of liver impairment as compared to patients with T2DM and no liver disease.
Detailed description
Glycosylated hemoglobin A1c (HbA1c), a reliable test to assess chronic glycemia and recommended both for the diagnosis and monitoring of T2DM, is neither accurate nor reliable in patients with cirrhosis. A validation study has not been performed to define its true usefulness in the setting of cirrhosis. The study aims to determine the level of HbA1c that better corresponds to the diagnosis of T2DM - as determined by an oral glucose tolerance test (OGTT) - and to correlate the levels of HbA1c with the average glucose over a 12-week period in patients with cirrhosis and known T2DM, in cirrhotic patients with different degrees of liver impairment. This study is designed as a pilot, observational, cross-sectional (Group A - cirrhotics with no T2DM) and longitudinal study (Group B - cirrhotics with known diabetes). For our first aim (Group A) the diagnostic yield of HbA1c for T2DM will be compared to that of an OGTT. Regarding the second aim (Group B) HbA1c will be compared to glucose reading from a continuous glucose monitor. In both groups, the following study labs will be performed: fructosamine, Complete Blood Count (CBC), liver function tests, chemistry, International Normalized Ratio (INR), and pre albumin. A total of 26 patients per group will be included.
STUDY AIMS
The study will look into three primary aims:
- To determine the level of HbA1c that better corresponds to the diagnosis of T2DM - as determined by an OGTT - in cirrhotic patients with different degrees of liver impairment.
- Will test the hypothesis of lower levels of HbA1c being found in T2DM in patients with decompensated cirrhosis when compared to those with compensated disease.
- To correlate the levels of HbA1c with the average glucose (AG) over a 12-week period in patients with cirrhosis and known T2DM, according to different degrees of liver impairment.
- Will test the hypothesis of progressively lower levels of HbA1c being associated with hyperglycemia in diabetic patients with decompensated cirrhosis when compared to those with compensated disease.
- To compare the performance of continuous glucose monitoring, particularly the level of agreement between the AG over a 12-week period and HbA1c, in patients with cirrhosis and known T2DM with that of controls with T2DM but no known chronic liver disease (including cirrhosis).
As secondary aims will:
- Determine the prevalence of T2DM in cirrhotics with different degrees of liver disease according to use of fasting glucose, HbA1c, or OGTT.
- Determine the level of HbA1c that better defines well-controlled diabetes in patients with cirrhosis and known T2DM, according to different degrees of liver impairment.
- Glucose variability in patients with cirrhosis and T2DM with that of patients with T2DM but no chronic liver disease (including cirrhosis).
Study Procedures
All patients will be identified and recruited from any of the Liver or GI clinics in the Outpatient Center, UAMS. To test the first aim (Group A) - the cross-sectional part of the study - patients with cirrhosis and varying degrees of liver dysfunction but no prior diagnosis of T2DM will have an OGTT performed after overnight fasting (8-12 hours). The OGTT consists of taking a baseline glucose determination, followed by a second one 2 hours after swallowing a 75-g glucose load. HbA1c will be obtained before OGTT (with baseline glucose) along with the following tests: HbA1c, fructosamine, insulin, CBC, HFP, GGT, OP Chem 7, INR, and prealbumin. Anthropometrics (height, weight, and waist circumference) will be obtained as well (Research Visit 1, see calendar).
All patients will be identified and recruited from any of the Liver or GI clinics in the Outpatient Center, UAMS. For the second aim (Group B) - the longitudinal part of the study - patients with known diabetes and cirrhosis with varying degrees of liver dysfunction will wear a continuous glucose monitor (Dexcom, San Diego, CA) for ≥3 continuous days during week days and week ends, every 4 weeks for 12 consecutive weeks, according to the manufacturer's recommendations. The continuous glucose monitor will record patient's glucose from the odd to the even research visit (i.e. from 1 to 2, 3 to 4, 5 to 6, and 7 to 8). On the last day the continuous glucose monitor is retrieved by the investigators, patients will have the following blood tests performed after overnight fasting (8-12 hours): HbA1c, fructosamine, CBC, HFP, GGT, BMP, INR, and prealbumin. Anthropometrics (height, weight, and waist circumference) will be obtained as well (Research Visit 8, see calendar). In order not to affect glucose control during the study period glucose reads from the continuous glucose monitor will not be disclosed to the patient until the end of the study.
All controls will be identified from the Endocrinology or Internal Medicine clinics in the Outpatient Center, UAMS. Controls will wear a continuous glucose monitor (Dexcom, San Diego, CA) for ≥3 continuous days during week days and week ends, every 4 weeks for 12 consecutive weeks, according to the manufacturer's recommendations. The continuous glucose monitor will record patient's glucose from the odd to the even research visit (i.e. from 1 to 2, 3 to 4, 5 to 6, and 7 to 8). On the last day the continuous glucose monitor is retrieved by the investigators, patients will have the following blood tests performed after overnight fasting (8-12 hours): HbA1c, CBC, and a metabolic profile; as per standard of care recommendations. Anthropometrics (height, weight, and waist circumference) will be obtained as well (Research Visit 8, see calendar - this research visit will occur on the same day of a diabetes follow up outpatient visit). In order not to affect glucose control during the study period glucose reads from the continuous glucose monitor will not be disclosed to the patient until the end of the study.
Given that the study only attempts to investigate the accuracy of HbA1c by comparing it to glucose and other biomarkers, no specific therapeutic interventions or recommendations concerning treatment of diabetes will be required during the study.
Sample Size
Since there is no precedent in the literature showing preliminary data to allow for sample calculation, will include 30 patients for each of the CTP stages A, B, and C, for both groups. This number should allow more than the minimum needed to perform correlation analyses (between and within groups) with confidence.
Sample Size
Since there is no precedent in the literature showing preliminary data to allow for sample calculation, will aim to have complete data on 26 patients per group (10 CTP A, 8 CTP B, and 8 CTP C in each group). However, given that the estimated attrition rate in Group B is 30%, will aim to recruit up to 34 patients for this group. We are planning on recruiting one control for each subject in control B, so that the number of controls would not exceed 34. Thus, the total number of subjects in study will be no more than 94. This number should allow more than the minimum needed to perform correlation analyses (between and within groups) with confidence.
Data Analysis
All glucose determinations from the continuous glucose monitoring will be summarized as an arithmetic mean. Shapiro-Wilk will be used to determine normal distribution of data. Receiver operation characteristic (ROC) curves will be constructed to determine the best cut-off to diagnose T2DM, using OGTT results as the gold standard. Spearman's or Pearson's correlation coefficient will be used to compare HbA1c to average glucose (eAG). Bland-Altman will be used to determine agreement. The estimated average glucose from HbA1c will be derived from a linear regression model, as previously described. Linear regression models will be performed to identify factors affecting HbA1c for both Groups A and B, such as hemoglobin, CTP, MELD, total protein, and prealbumin. CTP will be transformed to dummy variables for this analysis.
Data collection and handling Apart from the data generated by the study, demographics and clinical information to properly classify the hepatic functional and diabetes of each participant will be retrieved from the electronic medical record (EMR). Such information will include results from standard of care laboratories, imaging, and other special studies (EGD), to calculate Child-Turcotte-Pugh (CTP) and MELD scores.
A database will be created to accumulate all of the clinical information generated during this study. No identifiers, apart from name and Date of Birth(DOB), will be collected. All data will be stored in databases kept in a study folder created at PI's computer (password-protected). Main database will include identification (ID) assigned, and once an analytic table is created, all PHI will be removed from the table (after approval by the PI). Only this de-identified dataset with unique study ID's will be used for statistical analyses. Therefore, the risk to the privacy of the individuals will be minimized.
The access to the research folder and its contents will be restricted to the research staffs listed in this submission form. The PHI will be kept in the main database for no more than 10 years. The main database containing PHI will be kept in the study folder and will be never transferred out without de-identification of the data. No hard copy research data will be generated in this project.
Risks and Benefits
The risks associated with venipuncture and repeated blood collection from a vein are minor bleeding, bruising, infection (a small risk any time the skin is broken), or needing more than one attempt to locate veins.
There are no risks to the OGTT, although subjects may not like the taste of the highly concentrated glucose beverage. Occasionally someone may have low blood sugar or high blood sugar after the test. Blood glucose will be monitored before and during the test.
Some risks associated with the Dexcom G4 System Device have been reported: placing the devices in your skin may cause some anxiety, pain, irritation, redness, and swelling. There is also the risk of infection, excessive bleeding, or hematoma (swelling filled with blood caused by a broken blood vessel) - these risks are rare. Removing the sensor may also cause some discomfort or irritation because of the tape used. This reaction usually goes away within a few hours, but may last up to a week. There may be some itching in the area, which is a normal healing response.
In rare cases, the sensor may break while inserted. If this happens, the study team and will examine the area. Sometimes the study team may decide to leave the sensor fragment in place. If there is redness, pain, or infection, the study team will decide how to treat it. You should not try to remove the sensor yourself if it is broken unless the study team tells you to.
the University of Arkansas (UAMS) firewall and only used for specific research purposes in this project. Aggregated data will be analyzed and published, but specific data elements will not be made available. Further, subjects will not forfeit any rights by participating - their health care and eligibility for health benefits will not be affected in any way. Although a breach in confidentiality is always a risk when collecting personal information from patients, we believe this is small given the system that has been developed to obtain and handle data.
Ethics This study will be conducted according to US and international standards of Good Clinical Practice (FDA regulations) for all studies. Applicable government regulations, University of Arkansas for Medical Sciences research policies and procedures will also be followed. This protocol and any amendments will be submitted and approved by the University of Arkansas for Medical Sciences Institutional Review Board (IRB) to conduct the study. All subjects for this study will be provided a consent form describing this study and providing sufficient information in language suitable for subjects to make an informed decision about their participation in this study. The formal consent of a subject, using the IRB-approved consent form, will be obtained before that subject is submitted to any study procedure. This consent form must be signed by the subject or legally acceptable surrogate, and the investigator-designated research professional obtaining the consent.
Study design
- Observational model
- Case-control
- Time perspective
- Prospective
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Group A | – | –* Cirrhosis, either clinically- or biopsy-proven * Child-Pugh-Turcotte (CTP) A, B, and C (only biopsy-proven in the case of CTP-A) * Random glucose <200 mg/dL on at least 3 occasions * No use of insulin or any hypoglycemic agent (Group A) patients with cirrhosis and varying degrees of liver dysfunction but no prior diagnosis of T2DM will have an OGTT performed after overnight fasting (8-12-hours). HbA1c will be obtained before OGTT along with the following tests: HbA1c, fructosamine, insulin, CBC, HFP, GGT, OP Chem 7, INR, and prealbumin. |
| Group B | – | Device: Continuous glucose monitor (Dexcom, San Diego, CA)* Cirrhosis, either clinically- or biopsy-proven * Child-Pugh-Turcotte (CTP) A, B, and C (only biopsy-proven in the case of CTP-A) * Prior diagnosis of T2DM as based on any of ADA criteria * Use of insulin or any hypoglycemic agent (Group B) patients with known diabetes and cirrhosis with varying degrees of liver dysfunction will wear a continuous glucose monitor (?Dexcom, ?Medtronic) for 2 continuous days during week days and week ends, every 4 weeks for 12 consecutive weeks. On the day the continuous monitor is retrieved by the investigators, patients will have the following blood tests performed after overnight fasting (8-12-hours): HbA1c, fructosamine, CBC, HFP, GGT, BMP, INR, and prealbumin. |
| Control | – | Device: Continuous glucose monitor (Dexcom, San Diego, CA)* Age 18 to 75 * No known chronic liver disease * Prior diagnosis of T2DM as based on any of ADA criteria * Use of insulin or any hypoglycemic agent |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
- Study population
- Patients with cirrhosis with and without T2DM
Key inclusion criteria (15 listed)
- Group A
- Cirrhosis, either clinically- or biopsy-proven
- Child-Pugh-Turcotte (CTP) A, B, and C (only biopsy-proven in the case of CTP-A)
- Random glucose <200 mg/dL on at least 3 occasions
- No use of insulin or any hypoglycemic agent
Key exclusion criteria (10 listed)
- Hemoglobin <10 mg/dL
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Continuous glucose monitor (Dexcom, San Diego, CA)(Group B) patients with known diabetes and cirrhosis with varying degrees of liver dysfunction will wear a continuous glucose monitor (Dexcom, San Diego, CA) for 2 continuous days during week days and week ends, every 4 weeks for 12 consecutive weeks. | Device | Control, Group B |
Primary outcome
Level of HbA1c in T2DM and cirrhosis
Time frame: 12 weeks
Patients with cirrhosis and varying degrees of liver dysfunction but no prior diagnosis of T2DM will have an OGTT performed after overnight fasting (8-12-hours).
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 7 Nov 2017.
Related trials for Cirrhosis
RecruitingObservational study
Effectiveness and Clinical Outcomes of Long-term Bulevirtide Monotherapy in Patients With HDV-related Compensated Cirrhosis
Hepatitis D
Recruiting
Optimal Treatment Strategy for Spontaneous Bacterial Peritonitis
Spontaneous Bacterial Peritonitis, Paracentesis
RecruitingObservational study
The Value of Spleen Thickness and Spleen Diameter for Gastroesophageal Varices Diagnosis in Compensated Cirrhosis
Liver Cirrhosis, Gastroesophageal Varices
Recruiting
CirrhosisRx CDS System
Cirrhosis, Decision Support Systems, Clinical
RecruitingPhase 3
Trial to Evaluate ALN-CIDEB in Adults With Metabolic Dysfunction-Associated Steatotic Liver Disease (MASLD)
Metabolic Dysfunction-Associated Steatotic Liver Disease, MASLD
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Andres Duarte-Rojo, MD, PhD principal investigator
University of Arkansas
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Cirrhosis and Diabetes Mellitus, Type 2, run by University of Arkansas at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 15 inclusion and 10 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 7 Nov 2017. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Level of HbA1c in T2DM and cirrhosis (time frame: 12 weeks). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Nov 2017.