Muscle WeaknessNCT02261428
Nasotracheal Suction With Tiemann Catheter Compared to the Classic Technique With the Suction Catheter
A study testing Catheter Tiemann and Suction catheter in people with Muscle Weakness, run by Grigoriadis Konstantinos.
Trial summary
The study compares the effectiveness of Tiemann and Suction catheters, with regard to attempts to enter the trachea and the time required for the procedure. Read more about this study
- Who is it for?
- Ages 45 to 85 years
- Conditions the study is for
- Muscle Weakness
- What is being tested?
- Catheter Tiemann and Suction catheter
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 20 participants
- Where
- No sites listed yet
- Study dates
- May 2014to Sep 2014
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 45 to 85 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- ICU patients with nasogastric tube and spontaneous breathing without artificial airway
- Inability to mobilize and handle secretions
- Glasgow Coma Scale (GCS) >12/15
- PaO2/FiO2 ratio >100
Who cannot join
- Active nasal bleeding
- international normalized ratio (INR)>3
- Glasgow Coma Scale (GCS) <11/15
- Facial or basal cranial fractures
- Tumor in trachea
- Pregnancy
- ICU patients with endotracheal tube or tracheostomy tube
About this study
Official title: Randomized Controlled Study of Nasotracheal Suction With Tiemann Catheter Compared to the Classic Technique With the Standard One.
The study compares the effectiveness of Tiemann and Suction catheters, with regard to attempts to enter the trachea and the time required for the procedure.
Read the detailed description
The population of the study was twenty (20) patients, hospitalized in General and Cardiothoracic ICU, mostly with respiratory failure of various etiologies, the majority of which has complicated with Unit Myoneuropathy. This state confirmed by medical research council (MRC) Sum score which gave a result less than 48/6011 which corresponds to thirteen (13) patients in the total population of the study.
The randomization of the study achieved using the sealed envelopes method and associated with the catheter to be first used in the suction9,10 (Tiemann or suction catheter).
Twenty (20) sealed envelopes were prepared from a team not related to the study. The sealed envelopes had an inside paper with the sign "T" for the first ten (10) envelopes and "N" for the rest ten (10) of them.
When a new patient met the criteria for this study, one sealed envelope was randomly selected to determine the technique would come first: "T" for Tiemann technique or "N" for Suction catheter technique.
Furthermore the following parameters tabulated for each patient:
- Sex
- Unit
- Cause input
- First catheter used
- Second catheter used
- Hospitalization day
- Age
- Possible causes weakness
- Percentage oxygen mixture fraction of inspired oxygen (FiO2) and
- Oxygen partial pressure (PaO2) before any action
In addition to the above, all the parameters needed for calculating the Sequential Organ Failure Assessment score (SOFA) were tabulated, such as:
- Bilirubin
- The Glasgow Coma Score
- Platelets
- Mean arterial pressure
- Creatinine and urine 24 hours
Finally, it was recorded for each patient before and after the two catheterizations as indicators of disturbance and physiological burden attached to the intervention:
- The systolic and diastolic blood pressure
- The respiratory rate
- The heart rate
- The saturation of hemoglobin
- The blood gases, which recorded the partial pressure of oxygen (PaO2), carbon dioxide carbon dioxide partial pressure (PaCO2), the Ph and bicarbonates (HCO3).
A first check took place to identify each patient who met the admission criteria for the study.
The procedure required two people skilled in the nasotracheal suction (NTS), the first one to perform the NTS and the other one to record the time and the attempts needed, and it was beginning by correcting the posture of each patient on the bed, when the Great Trochanter was more than 20 centimeters away from the hinge of the bed.
The pillow beneath the patient's head was removed to have an extended position, the first blood gas analysis was done and the parameters mentioned above were recorded in the relevant tables.
To determine the access of the trachea, it was used a stethoscope to hear turbulent flow on the anterior surface of the chest.
The whole procedure comprises two "steps":
- Achieving of the entrance into the nasopharynx b) Achieving of the entrance into the trachea
- To achieve the entrance into the nasopharynx:
- It was selected the opposite nostril that Levine was placed.
- The insertion of the catheter was always opposite to the medial canthus of the eye.
- If it was found resistance and the catheter was not inserted to the nasopharynx, it was pulled slightly outwardly and then inwardly. Each kind of micromanipulation recorded as attempt. The maximum number of attempts were agreed in Protocol Design (beyond which the attempts would stop) was five (5). In fact, in no cases was exceeded the limit of five attempts. The time recorded corresponds to the time needed for the successful advancement of the catheter in the nasopharynx through the nostril (T1).
- Achieving of the entrance into the trachea:
The successful insertion of the catheter into the trachea was confirmed by another member of the team using stethoscope and was determined by:
- Hearing of turbulent flow when closing the "fingertip" ii. Insertion without resistance iii. Tickly cough during the insertion.
The insertion to trachea was considered to be unsuccessful as the catheter insert into the esophagus and thus:
- There was no production of turbulent airflow when the hole of "fingertip"was closed ii. It was found resistance during the insertion of the catheter iii. There was a grimace of disgust on the patient's face. As the insertion was considered to be unsuccessful according to the above conditions, catheter was drawn slightly outward (less than one centimeter) and redirected to the trachea.
Each kind of micromanipulation recorded as attempt. The maximum number of attempts were agreed in Protocol Design was ten (10). Beyond the above limit the insertion was considered to be unsuccessful and repeated after half an hour15 with the other catheter (half an hour is the sufficient time for the patient to return to his initial condition).
The time of the second "step" recorded, corresponds to the time needed for the successful promotion of the catheter from the nasopharynx to the trachea (T2).
Finally it was recorded the time needed for each suction which was tabulated below as (T3).
The summation of (T1), (T2) and (T3) was reflected the total time needed for the whole procedure which was followed by a new blood gas analysis.
All parameters were recorded by the team involved to the study. The catheters used for this study were 14 French dia. of the same industry and from the same material (medical PVC).
As it was mentioned above, the whole idea based on the J-shape of the Tiemann catheter which is useful for the orientation of the catheter during the insertion to the nasopharynx first and then into the trachea and placed always downwards.
The oxygen face mask was maintained during the insertion of the catheter in order to continue the patient's oxygenation and avoid hypoxemia. This was achieved by leaving outside the oxygen face mask only the opposite nostril of the nasogastric tube.
No extra oxygen was given to patients before the procedure as pre-oxygenation.
The size of the sample was calculated based on a pilot study and was determined to twenty (20) patients were not included in the main study. Thus ten (10) patients underwent an equal number of nasotracheal suctioning with Tiemann catheter and ten (10) with Suction catheter.
For standard deviation σ1=3.9, and an error α=0,05 and power 80, the sample size must be bigger than twelve (12).
From all the above the investigators summarize that the sample size of twenty (20) patients was adequate.
For the statistical analysis was used the SPSS 20 Inc., Chicago, IL, and for paired values the Paired T-Test and Wilcoxon Signed Rank Test.
For paired nominal parameters was used the McNemar Χ2 test. To determine normal distributions, was used the Kolmogorov-Smirnov test. In the majority of cases data are presented as Median (Range) in abnormal distributions and Mean (SD) in normal.
Odds ratio was used to quantify how strongly Tiemann associated with Suction catheter in total attempts.
Significance was taken as P < 0.05. To determine the difference in time needed by using the two catheters was used Kaplan-Mayer analysis and long-rank test.
- Conditions
- Muscle Weakness
- Being tested
- Catheter Tiemann, Suction catheter
- Keywords
- Nasotracheal suction, tracheal access
- Medical subject headings
- Muscle Weakness
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Catheter TiemannDevice
We tested the ability of Tiemann catheter to access trachea in order to aspirate bronchial secretions in ICU patients
Suction catheterDevice
We tested the ability of Suction catheter to access trachea in order to aspirate bronchial secretions in ICU patients
| Study group | Role | What they receive |
|---|---|---|
| Catheter Tiemann | Experimental | We tested the ability of Tiemman catheter to access trachea and aspirate bronchial secretions, measuring number of attempts and time required for the intervention Receives: Device: Catheter Tiemann |
| Suction catheter | Active comparator | We tested the ability of suction catheter to access trachea and aspirate bronchial secretions, measuring number of attempts and time required for the intervention Receives: Device: Suction catheter |
What is being measured
The primary outcome is the main question the study is designed to answer.
Number of Attempts Before Entering Trachea
We count the required attempts to insert catheter into trachea (number of attempts)
Measured: An average of 15 seconds
Secondary outcomes (6)
Time to Entering Trachea
We count the required time needed to insert catheter into trachea (seconds).
Measured: An average of 15 seconds
Respiratory Rate Immediately After Intervention
Recorded the respiratory rate (breaths per minute), immediately after intervention
Measured: Within 2 seconds after catheter withdrawal.
Heart Rate Immediately After Intervention
Immediately after each intervention recorded the heart rate (beats per minute).
Measured: Within 2 seconds after catheter withdrawal.
Systolic Blood Pressure Immediately After Each Intervention
Immediately after each intervention recorded the systolic blood pressure (mmHg).
Measured: Within 2 seconds after catheter withdrawal.
Diastolic Blood Pressure Immediately After Each Intervention
Immediately after each intervention recorded the diastolic blood pressure (mmHg).
Measured: Within 2 seconds after catheter withdrawal.
Presence of Blood on Catheter Immediately After Each Intervention
Immediately after each intervention recorded the presence or absence of blood on the catheter (Yes or No).
Measured: Within 2 seconds after catheter withdrawal.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted10 Oct 2014 (estimated)
- Study startMay 2014
- Primary completionSep 2014
- Study completionSep 2014
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (8)Papers the sponsor has linked to this study.
- Other trials for Muscle WeaknessStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Supportive care
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 20 participants (actual)
Sponsor and investigators
- Lead sponsor
- Grigoriadis Konstantinos
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor-investigator, Grigoriadis Konstantinos, Attikon Hospital
- Investigators
- Dimitrios Angouras, MD, Study director, Athens University School of Medicine, Department of Cardiothoracic SurgeryTheodoros Xanthos, MD, Study director, Athens University School of Medicine, Postgraduate program in CPR (moderator)Konstantinos Grigoriadis, PT, Principal investigator, Attikon HospitalKaterina Flevari, MD, Study chair, Attikon Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02261428
- Sponsor's protocol ID
- AttikonH
- Status last verified
- Mar 2015
- First submitted
- 30 Sep 2014
- Last updated
- 17 Mar 2015
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
Publications
Pode D, Manny J. A simplified method for repeated nasotracheal suction. Surg Gynecol Obstet. 1984 Aug;159(2):173-4.
PubMed 6463830Brucia J, Rudy E. The effect of suction catheter insertion and tracheal stimulation in adults with severe brain injury. Heart Lung. 1996 Jul-Aug;25(4):295-303. doi: 10.1016/s0147-9563(96)80065-3.
PubMed 8836745Gemma M, Tommasino C, Cerri M, Giannotti A, Piazzi B, Borghi T. Intracranial effects of endotracheal suctioning in the acute phase of head injury. J Neurosurg Anesthesiol. 2002 Jan;14(1):50-4. doi: 10.1097/00008506-200201000-00010.
PubMed 11773824Marlow TJ, Goltra DD Jr, Schabel SI. Intracranial placement of a nasotracheal tube after facial fracture: a rare complication. J Emerg Med. 1997 Mar-Apr;15(2):187-91. doi: 10.1016/s0736-4679(96)00356-3.
PubMed 9144060Sloan EP, VanRooyen MJ. Suction catheter-assisted nasotracheal intubation. Acad Emerg Med. 1994 Jul-Aug;1(4):388-90. doi: 10.1111/j.1553-2712.1994.tb02651.x.
PubMed 7614287Roppolo LP, Vilke GM, Chan TC, Krishel S, Hayden SR, Rosen P, Trione M. Nasotracheal intubation in the emergency department, revisited. J Emerg Med. 1999 Sep-Oct;17(5):791-9. doi: 10.1016/s0736-4679(99)00085-2.
PubMed 10499691Saissy JM, Boussignac G, Cheptel E, Rouvin B, Fontaine D, Bargues L, Levecque JP, Michel A, Brochard L. Efficacy of continuous insufflation of oxygen combined with active cardiac compression-decompression during out-of-hospital cardiorespiratory arrest. Anesthesiology. 2000 Jun;92(6):1523-30. doi: 10.1097/00000542-200006000-00007.
PubMed 10839900Grigoriadis KEpsilon, Angouras DC, Flevari A, Xathos T. Comparison of the Feasibility and Safety of Nasotracheal Suctioning With Curved Edge Catheter Versus Conventional Suction Catheter in Critically Ill Subjects: A Prospective Randomized Crossover Trial. Respir Care. 2015 Dec;60(12):1826-33. doi: 10.4187/respcare.03875. Epub 2015 Oct 20.
PubMed 26487746
Study at a glance
From the registry record, last updated by the sponsor on 17 Mar 2015. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Randomized Controlled Study of Nasotracheal Suction With Tiemann Catheter Compared to the Classic Technique With the Standard One.
- ClinicalTrials.gov ID
- NCT02261428
- Acronym / sponsor ID
- AttikonH
- Conditions
- Muscle Weakness
- Keywords
- Nasotracheal suction, tracheal access
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 20 participants (actual)
- Lead sponsor
- Grigoriadis KonstantinosUniversity, hospital or other
- Study start
- May 2014
- Primary completion
- Sep 2014 (actual)
- Study completion
- Sep 2014 (actual)
- First posted
- 10 Oct 2014 (estimated)
- Results
- Posted 17 Mar 2015
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The study compares the effectiveness of Tiemann and Suction catheters, with regard to attempts to enter the trachea and the time required for the procedure.
Detailed description
The population of the study was twenty (20) patients, hospitalized in General and Cardiothoracic ICU, mostly with respiratory failure of various etiologies, the majority of which has complicated with Unit Myoneuropathy. This state confirmed by medical research council (MRC) Sum score which gave a result less than 48/6011 which corresponds to thirteen (13) patients in the total population of the study.
The randomization of the study achieved using the sealed envelopes method and associated with the catheter to be first used in the suction9,10 (Tiemann or suction catheter).
Twenty (20) sealed envelopes were prepared from a team not related to the study. The sealed envelopes had an inside paper with the sign "T" for the first ten (10) envelopes and "N" for the rest ten (10) of them.
When a new patient met the criteria for this study, one sealed envelope was randomly selected to determine the technique would come first: "T" for Tiemann technique or "N" for Suction catheter technique.
Furthermore the following parameters tabulated for each patient:
- Sex
- Unit
- Cause input
- First catheter used
- Second catheter used
- Hospitalization day
- Age
- Possible causes weakness
- Percentage oxygen mixture fraction of inspired oxygen (FiO2) and
- Oxygen partial pressure (PaO2) before any action
In addition to the above, all the parameters needed for calculating the Sequential Organ Failure Assessment score (SOFA) were tabulated, such as:
- Bilirubin
- The Glasgow Coma Score
- Platelets
- Mean arterial pressure
- Creatinine and urine 24 hours
Finally, it was recorded for each patient before and after the two catheterizations as indicators of disturbance and physiological burden attached to the intervention:
- The systolic and diastolic blood pressure
- The respiratory rate
- The heart rate
- The saturation of hemoglobin
- The blood gases, which recorded the partial pressure of oxygen (PaO2), carbon dioxide carbon dioxide partial pressure (PaCO2), the Ph and bicarbonates (HCO3).
A first check took place to identify each patient who met the admission criteria for the study.
The procedure required two people skilled in the nasotracheal suction (NTS), the first one to perform the NTS and the other one to record the time and the attempts needed, and it was beginning by correcting the posture of each patient on the bed, when the Great Trochanter was more than 20 centimeters away from the hinge of the bed.
The pillow beneath the patient's head was removed to have an extended position, the first blood gas analysis was done and the parameters mentioned above were recorded in the relevant tables.
To determine the access of the trachea, it was used a stethoscope to hear turbulent flow on the anterior surface of the chest.
The whole procedure comprises two "steps":
- Achieving of the entrance into the nasopharynx b) Achieving of the entrance into the trachea
- To achieve the entrance into the nasopharynx:
- It was selected the opposite nostril that Levine was placed.
- The insertion of the catheter was always opposite to the medial canthus of the eye.
- If it was found resistance and the catheter was not inserted to the nasopharynx, it was pulled slightly outwardly and then inwardly. Each kind of micromanipulation recorded as attempt. The maximum number of attempts were agreed in Protocol Design (beyond which the attempts would stop) was five (5). In fact, in no cases was exceeded the limit of five attempts. The time recorded corresponds to the time needed for the successful advancement of the catheter in the nasopharynx through the nostril (T1).
- Achieving of the entrance into the trachea:
The successful insertion of the catheter into the trachea was confirmed by another member of the team using stethoscope and was determined by:
- Hearing of turbulent flow when closing the "fingertip" ii. Insertion without resistance iii. Tickly cough during the insertion.
The insertion to trachea was considered to be unsuccessful as the catheter insert into the esophagus and thus:
- There was no production of turbulent airflow when the hole of "fingertip"was closed ii. It was found resistance during the insertion of the catheter iii. There was a grimace of disgust on the patient's face. As the insertion was considered to be unsuccessful according to the above conditions, catheter was drawn slightly outward (less than one centimeter) and redirected to the trachea.
Each kind of micromanipulation recorded as attempt. The maximum number of attempts were agreed in Protocol Design was ten (10). Beyond the above limit the insertion was considered to be unsuccessful and repeated after half an hour15 with the other catheter (half an hour is the sufficient time for the patient to return to his initial condition).
The time of the second "step" recorded, corresponds to the time needed for the successful promotion of the catheter from the nasopharynx to the trachea (T2).
Finally it was recorded the time needed for each suction which was tabulated below as (T3).
The summation of (T1), (T2) and (T3) was reflected the total time needed for the whole procedure which was followed by a new blood gas analysis.
All parameters were recorded by the team involved to the study. The catheters used for this study were 14 French dia. of the same industry and from the same material (medical PVC).
As it was mentioned above, the whole idea based on the J-shape of the Tiemann catheter which is useful for the orientation of the catheter during the insertion to the nasopharynx first and then into the trachea and placed always downwards.
The oxygen face mask was maintained during the insertion of the catheter in order to continue the patient's oxygenation and avoid hypoxemia. This was achieved by leaving outside the oxygen face mask only the opposite nostril of the nasogastric tube.
No extra oxygen was given to patients before the procedure as pre-oxygenation.
The size of the sample was calculated based on a pilot study and was determined to twenty (20) patients were not included in the main study. Thus ten (10) patients underwent an equal number of nasotracheal suctioning with Tiemann catheter and ten (10) with Suction catheter.
For standard deviation σ1=3.9, and an error α=0,05 and power 80, the sample size must be bigger than twelve (12).
From all the above the investigators summarize that the sample size of twenty (20) patients was adequate.
For the statistical analysis was used the SPSS 20 Inc., Chicago, IL, and for paired values the Paired T-Test and Wilcoxon Signed Rank Test.
For paired nominal parameters was used the McNemar Χ2 test. To determine normal distributions, was used the Kolmogorov-Smirnov test. In the majority of cases data are presented as Median (Range) in abnormal distributions and Mean (SD) in normal.
Odds ratio was used to quantify how strongly Tiemann associated with Suction catheter in total attempts.
Significance was taken as P < 0.05. To determine the difference in time needed by using the two catheters was used Kaplan-Mayer analysis and long-rank test.
Study design
- Primary purpose
- Supportive care
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Catheter Tiemann | Experimental | Device: Catheter TiemannWe tested the ability of Tiemman catheter to access trachea and aspirate bronchial secretions, measuring number of attempts and time required for the intervention |
| Suction catheter | Active comparator | Device: Suction catheterWe tested the ability of suction catheter to access trachea and aspirate bronchial secretions, measuring number of attempts and time required for the intervention |
Who may qualify
- Ages
- 45 to 85 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- ICU patients with nasogastric tube and spontaneous breathing without artificial airway
- Inability to mobilize and handle secretions
- Glasgow Coma Scale (GCS) >12/15
- PaO2/FiO2 ratio >100
Key exclusion criteria (7 listed)
- Active nasal bleeding
- international normalized ratio (INR)>3
- Glasgow Coma Scale (GCS) <11/15
- Facial or basal cranial fractures
- Tumor in trachea
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Catheter TiemannWe tested the ability of Tiemann catheter to access trachea in order to aspirate bronchial secretions in ICU patients | Device | Catheter Tiemann |
| Suction catheterWe tested the ability of Suction catheter to access trachea in order to aspirate bronchial secretions in ICU patients | Device | Suction catheter |
Primary outcome
Number of Attempts Before Entering Trachea
Time frame: An average of 15 seconds
We count the required attempts to insert catheter into trachea (number of attempts)
6 secondary outcomes
Time to Entering Trachea
Time frame: An average of 15 seconds
Respiratory Rate Immediately After Intervention
Time frame: Within 2 seconds after catheter withdrawal.
Heart Rate Immediately After Intervention
Time frame: Within 2 seconds after catheter withdrawal.
Systolic Blood Pressure Immediately After Each Intervention
Time frame: Within 2 seconds after catheter withdrawal.
Diastolic Blood Pressure Immediately After Each Intervention
Time frame: Within 2 seconds after catheter withdrawal.
Presence of Blood on Catheter Immediately After Each Intervention
Time frame: Within 2 seconds after catheter withdrawal.
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 Mar 2015.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Background: PubMed 6463830Pode D, Manny J. A simplified method for repeated nasotracheal suction. Surg Gynecol Obstet. 1984 Aug;159(2):173-4.
- Background: PubMed 8836745Brucia J, Rudy E. The effect of suction catheter insertion and tracheal stimulation in adults with severe brain injury. Heart Lung. 1996 Jul-Aug;25(4):295-303. doi: 10.1016/s0147-9563(96)80065-3.
- Background: PubMed 11773824Gemma M, Tommasino C, Cerri M, Giannotti A, Piazzi B, Borghi T. Intracranial effects of endotracheal suctioning in the acute phase of head injury. J Neurosurg Anesthesiol. 2002 Jan;14(1):50-4. doi: 10.1097/00008506-200201000-00010.
- Background: PubMed 9144060Marlow TJ, Goltra DD Jr, Schabel SI. Intracranial placement of a nasotracheal tube after facial fracture: a rare complication. J Emerg Med. 1997 Mar-Apr;15(2):187-91. doi: 10.1016/s0736-4679(96)00356-3.
- Background: PubMed 7614287Sloan EP, VanRooyen MJ. Suction catheter-assisted nasotracheal intubation. Acad Emerg Med. 1994 Jul-Aug;1(4):388-90. doi: 10.1111/j.1553-2712.1994.tb02651.x.
- Background: PubMed 10499691Roppolo LP, Vilke GM, Chan TC, Krishel S, Hayden SR, Rosen P, Trione M. Nasotracheal intubation in the emergency department, revisited. J Emerg Med. 1999 Sep-Oct;17(5):791-9. doi: 10.1016/s0736-4679(99)00085-2.
- Background: PubMed 10839900Saissy JM, Boussignac G, Cheptel E, Rouvin B, Fontaine D, Bargues L, Levecque JP, Michel A, Brochard L. Efficacy of continuous insufflation of oxygen combined with active cardiac compression-decompression during out-of-hospital cardiorespiratory arrest. Anesthesiology. 2000 Jun;92(6):1523-30. doi: 10.1097/00000542-200006000-00007.
- Derived from this study: PubMed 26487746Grigoriadis KEpsilon, Angouras DC, Flevari A, Xathos T. Comparison of the Feasibility and Safety of Nasotracheal Suctioning With Curved Edge Catheter Versus Conventional Suction Catheter in Critically Ill Subjects: A Prospective Randomized Crossover Trial. Respir Care. 2015 Dec;60(12):1826-33. doi: 10.4187/respcare.03875. Epub 2015 Oct 20.
Related trials for Muscle Weakness
Enrolling by invitation
Online Exercise Program for Transplant Patients: A Pilot Study
Kidney Transplantation, Physical Function
Recruiting
Web-Based Tele-Rehabilitation Using Action Observation and Mirror Therapy for Subacute Stroke: A Randomized Controlled Trial
Stroke, Upper Extremity Paresis
Active, not recruitingPhase 1
E-CEL UVEC Cells as an Adjunct Cell Therapy for the Arthroscopic Rotator Cuff Repair in Adults
Rotator Cuff Tears, Muscle Atrophy or Weakness
Recruiting
Assisted Ambulation to Improve Health Outcomes for Older Medical Inpatients
Mobility Limitation, Frailty
Not yet recruiting
Virtual Reality Training Dose for Arm Recovery After Stroke: Clinical and Blood Biomarker Responses
Stroke, Upper Extremity Paresis
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Dimitrios Angouras, MD study director
Athens University School of Medicine, Department of Cardiothoracic Surgery
Theodoros Xanthos, MD study director
Athens University School of Medicine, Postgraduate program in CPR (moderator)
Konstantinos Grigoriadis, PT principal investigator
Attikon Hospital
Questions about this trial
What is this clinical trial studying?
A study testing Catheter Tiemann and Suction catheter in people with Muscle Weakness, run by Grigoriadis Konstantinos.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 17 Mar 2015. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 17 Mar 2015). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Number of Attempts Before Entering Trachea (time frame: An average of 15 seconds). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02261428, which also lists 8 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Mar 2015.